Search NASA⌕ Search

SEARCH · Search NASA

Results for “microplasmas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Particle-in-cell Monte Carlo-collision modeling of non-ideal effects in wave-heated dense microplasmas

A computational model for non-ideal plasma effects during the time evolution of a second-stage laser-heated discharge at high pressures is presented. The model extends a classical one-dimensional particle-in-cell Monte Carlo-collision (PIC-MCC) approach coupled with Maxwell's equations for the laser-heating process of a xenon plasma at 300 K temperature and 10–100 bar pressure. Plasma non-ideality resulting from Coulomb coupling at high plasma densities is manifested as a depression in the effective ionization potential of atoms and enhanced collision cross sections. These non-ideal effects are represented using the Ecker–Kröll model in the context of the PIC-MCC approach. We find that full ionization of the plasma is obtained on the picosecond timescale, starting from the skin layer and quickly expanding throughout the domain through an anomalous extension of the skin depth. More critically, we show that the inclusion of the non-ideal plasma effects results in more rapid ionization compared to an ideal plasma, especially at higher pressures. The ionization delay reduction is of the order of a fraction of a picosecond, corresponding to a 16% decrease at 100 bar. As the amplitude of the wave field is lowered, the ionization rate is lowered, making the plasma non-ideality effects more prominent.

Solmaz, Evrim (ORCID:0000000211830881)↗

Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides. Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm 3 ) capable of generating an electron density of greater than 10 13 cm –3 was constructed to produce reactive species (N 2 *, N 2 +, O, OH, and H α ) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. In conclusion, this compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling of a 43 GHz microplasma within a photonic crystal

The electron density (n e ) and argon metastable density (1 s 5 ) of a 43GHz microplasma are obtained using the zero-dimensional plasma kinetics solver (ZDPlasKin®) for an incident power of 160 and 1000mW and argon pressures of 10–600Torr (1.3 ×10 3 to 8.0 × 10 4 Pa). These simulations are compared with previously published experimental data. To determine the self-consistent electric field in the modeled plasma, the three-dimensional millimeter wave fields are computed as a function of electron density using ANSYS EM19.2, HFSS®. This electromagnetic field model is coupled to ZDPlasKin such that any increase in the simulated plasma density correctly attenuates the simulated electric field within the microplasma. The electron density is found to be sensitive to argon gas temperature, so a two-zone temperature model was needed to obtain agreement with experimental measurements. The temperature in the central core of the microplasma was determined by a previous experimental study. That temperature was used as an input to the model for the simulation of volume recombination losses. The outer regions of the microplasma are assumed to be in equilibrium with the walls (300K). This second temperature was used in the model to determine diffusion losses. The modeled electron and metastable densities are of the order 10 20 and 10 18 m –3 , respectively. This is in good agreement with those measured experimentally as long as the two-zone temperature model is used. In the absence of a hot gas core, the modeled three-body recombination rates are excessive and the simulation severely under-predicts the electron density and over-estimates the metastable density. We conclude that the millimeter wave microplasma has a hot core (2500K at 600 Torr) that rarifies the argon gas and effectively reduces three-body recombination. Furthermore, this allows one to achieve high electron density on the order of 10 20 m –3 with only 100mW of wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data for Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides . Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm3) capable of generating an electron density of greater than 1013 cm–3 was constructed to produce reactive species (N2*, N2+, O, OH, and Hα) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. This compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

Conversion↗

High frequency impedance characteristics of a tunable microplasma device

Computational studies on high frequency impedance characteristics of a microplasma device are reported. While microplasma is ignited using a primary excitation signal, frequency response of plasma impedance is determined by a secondary high frequency probe signal with significantly lower voltage amplitude such that it does not influence the plasma parameters. Here, the computational model utilizing the drift–diffusion approximation is first validated by comparing with experimental data for microplasmas ignited at pressures ranging from 1 to 5 Torr. In spite of quantitative discrepancies, good overall agreement is obtained between the measured frequency response of impedance of the discharge. Comparisons are also presented for various plasma parameters including mean electron number density, sheath thickness, mean electron temperature, and collision frequency that were inferred from the impedance measurements. The computational model is then used to perform simulations of near-atmospheric pressure microplasmas with the probe signal frequency ranging from 3 to 20 GHz. The simulations demonstrate the presence of a resonance frequency at which the impedance vanishes. More importantly, it is shown that this resonant frequency can be tuned effectively by suitably modifying the operating parameters (gap size, pressure, and excitation voltage). The simulated impedance characteristics are used to determine the effective plasma inductance and capacitance using a non-linear fitting approach, thereby showing the dependence of these electrical parameters on the plasma operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Argon metastable density and temperature of a 43 GHz microplasma

Argon (1s 5 ) metastable density and translational gas temperature are experimentally measured using laser diode absorption spectroscopy within a 43 GHz microplasma. The plasma is initiated and sustained within a photonic crystal constructed from a rectangular array of alumina rods, each 1 mm in diameter. This configuration generates stable microplasma from 10 to 600 Torr using millimeter wave power from 100 to 1200 mW. The metastable density is in the order of 10 18 m –3 at low pressure. However, Ar(1s 5 ) density decreases to undetectable levels with increasing pressure and wave power. The gas temperature is extracted from the Lorentzian line shape of the absorption profile at 811.53 nm. The gas temperature increases from approximately 400 K at low pressure to 2000 K at 320 Torr (427 mbar, 4.27 × 10 4 Pa). Furthermore, these data are compared with previous results and suggest that the microplasma has a dense core of electrons that depletes the metastable density at high gas pressure and wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

94 GHz microplasma sustained by a photonic crystal

A photonic crystal (PhC) with a single vacancy sustains an argon microplasma at 94 GHz. The PhC consists of a 7 × 13 array of small alumina rods, each 250 μm in radius. The PhC has a forbidden bandgap from 70–105 GHz. The vacancy creates an internal electromagnetic resonance at 94 GHz that intensifies the electric field of an incident wave to 5 × 10 5 V m –1 . Breakdown of low-pressure argon gas (80 mbar) occurs and forms a stable, ellipsoidal plasma inside the crystal. The central core of the microplasma is probed using a 200 μm optical fiber inserted into the PhC. The rotational temperature of the CH molecule is estimated from a numerical fit of the plasma emission and is found to increase from 450–650 K with both pressure (200–1000 mbar) and incident wave power (100 mW–1100 mW). Under these conditions, the electron density increases with both power and pressure from 0.5–1.5 × 10 20 m –3 . Furthermore, this plasma density range brackets the electron plasma frequency at 94 GHz. The results are compared with a similar microplasma operating at 44 GHz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CH 3 Radical Generation in Microplasmas for Up-Conversion of Methane

The conversion of methane, CH 4 , into higher value chemicals using low temperature plasmas is challenged by both improving efficiency and selectivity. One path towards selectivity is capturing plasma produced methyl radicals, CH 3 , in a solvent for aqueous processing. Due to the rapid reactions of methyl radicals in the gas phase, the transport distance from production of the CH 3 to its solvation should be short, which then motivates the use of microplasmas. The generation of CH 3 in Ar/CH 4 /H 2 O plasmas produced in nanosecond pulsed dielectric barrier discharge microplasmas is discussed using results from a computational investigation. The microplasma is sustained in the channel of a microfluidic chip in which the solvent flows along one wall or in droplets. CH 3 is primarily produced by electron-impact of and dissociative excitation transfer to CH 4 , as well as CH 2 reacting with CH 4 . CH 3 is rapidly consumed to form C 2 H 6 which, in spite of being subject to these same dissociative processes, accumulates over time, as do other stable products including C 3 H 8 and CH 3 OH. The gas mixture and electrical properties were varied to assess their effects on CH 3 production. CH 3 production is largest with 5% CH 4 in the Ar/CH 4 /H 2 O mixture due to an optimal balance of electron-impact dissociation, which increases with CH 4 percentage, and dissociative excitation transfer and CH 2 reacting with CH 4 , which decrease with CH 4 percentage. Design parameters of the microchannels were also investigated. Increasing the permittivity of the dielectrics in contact with the plasma increased the ionization wave intensity which increased CH 3 production. Increased energy deposition per pulse generally increased CH 3 production as does lengthening pulse length up to a certain point. The arrangement of the solvent flow in the microchannel can also affect the CH 3 density and fluence to the solvent. The fluence of CH 3 to the liquid solvent is increased if the liquid is immersed in the plasma as a droplet or is a layer on the wall where the ionization wave terminates. The solvation dynamics of CH 3 with varying numbers of droplets was also examined. Here, the maximum density of solvated methyl radicals CH 3aq occurs with a large number of droplets in the plasma. However, the solvated CH 3aq density can rapidly decrease due to desolvation, emphasizing the need to quickly react the solvated species in the solvent.

03 NATURAL GAS↗

Direct current microplasma formation around microstructure arrays

We demonstrate the formation and transition behaviors of a microplasma around microstructure arrays at different gas pressures via two-dimensional particle-in-cell/Monte Carlo collision simulations. It is found that the microdischarge occurs outside the cathode microcavities at the lowest pressure and starts penetrating the microcavities with a curved sheath edge as the pressure increases. At higher pressure, coupled periodic microhollow cathode discharges (MHCDs) are formed inside the microcavities. Further increasing the gas pressure results in the disappearance of the MHCDs, and the dominant discharge shifts outside of the microcavity, locating above the protrusion tips. The effect of the space charge shielding on the discharge and the conditions for MHCD formation are discussed. The macroscopic discharge parameter scalings with the gas pressure and the electron kinetics are also examined. The results are helpful for deeply understanding the microplasma formation with nonplanar electrodes, which inform the scaling, design, and optimization of microplasma array devices across a wide range of pressure regimes in practical applications.

42 ENGINEERING↗

Investigation of the significance of excited species in wave-heated dense non-ideal microplasmas using particle-in-cell Monte Carlo-collision modeling

A computational model for the interaction of a high-pressure microplasma with an electromagnetic wave is presented. A one-dimensional particle-in-cell Monte Carlo collision model is used to investigate the plasma non-ideality effects in a second-stage laser-heated xenon plasma with a comprehensive chemistry mechanism, including excited species. A xenon microplasma at a temperature of 300 K and pressure of 10 bar becomes non-ideal after the laser heating stage with lower ionization and electronic excitation barriers, which makes the presence of excited species important to the plasma generation process. For these conditions, two-step ionization via excited species becomes a major contributor to plasma ionization. We find that full ionization of the plasma is obtained in ~2 ps when excited species are included in the chemistry model, as opposed to ~2.5 ps for a chemistry mechanism that does not consider their effect. With excited species, the ionization mode transitions from direct ionization via electron-neutral collisions to direct and stepwise ionization as the plasma generation progresses.

36 MATERIALS SCIENCE↗

One-step atmospheric microplasma synthesis of an NMC-type lithium-ion battery cathode

The manufacture of battery cathode materials is the most energy-intensive step in the production of commercial lithium-ion batteries; specifically, the synthesis of the widely used transition metal oxide cathodes can require tens of hours at temperatures exceeding 700 °C. Attempts to limit the reaction time and energy required to form crystalline cathode materials often still include a heating or calcination step. This communication aims to highlight a nascent yet novel synthesis route: a one-step atmospheric microplasma process for synthesizing cathode particles in less than one second. The hollow-tube reactor employed produces crystalline particles measuring 0.1–3 μm in diameter, displays narrow XRD peaks corresponding to the 003, 104, and 101 planes, and exhibits anodic redox behavior at 3.75 V vs. lithium—characteristic of transition-metal oxide cathode materials—all without requiring an additional calcination step.

25 ENERGY STORAGE↗

Metastable argon dynamics in a pulsed microplasma at 43 GHz

Short pulses of millimeter wave (MMW) radiation at 43 GHz create microplasma within a photonic crystal for pressures from 40 to 600 Torr (1.3 × 10 3 –8.0 × 10 4 Pa). Gas breakdown occurs within a photonic crystal, which acts as an electromagnetic resonator to create a strong initial electric field. The time response of the argon metastable density is experimentally determined during the pulse and in the afterglow using laser absorption. The metastable density overshoots the steady-state condition at the beginning of the pulse and during the afterglow. Modeling is presented to understand these observations. The overproduction of argon 1s5 at the beginning of each pulse is due to a concurrent overshoot in the MMW electric field within the photonic crystal. This field overheats the plasma electrons and enhances the production of excited states. The burst of argon metastables observed in the afterglow is due to the pooled energy of the plasma stored in electrons, ions, and excited states of argon. As a result, understanding metastable production is an important intermediate step to ionization and is also critical in the study of diode-pumped rare gas lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Number Density Quantification Utilizing Pulsing Frequency in Negative Differential Resistance (NDR) Regime of Microplasma Operation

A mathematical model is presented for quantifying the ion number density over a range of discharge current in microplasma discharges. The ion number density is determined from measured discharge voltage, current, pulsing frequency, and trace impurity that is injected into the system deliberately. Experiments are conducted in pure helium with nitrogen being introduced as the trace species. The ion number density is estimated over a range of discharge current and is compared with multidimensional simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Argon metastable density and temperature of a 94 GHz microplasma

Laser diode absorption spectroscopy is used to experimentally measure Ar(1s 5 ) metastable density and translational gas temperature within a 94 GHz microplasma. A square two-dimensional photonic crystal (PhC) at this resonance frequency serves to ignite and sustain the plasma from 20 to 200 Torr (2.7 × 10 3 –2.7 × 10 4 Pa) by using millimeter wave power from 300 to 1000 mW. Metastable density within the plasma is estimated from the absorption line shape of the laser traversing the PhC. The metastable density reaches an order of 10 19 m –3 at lower pressure and decreases as pressure increases. From the Lorentzian line shape of the absorption profile at 811.53 nm, the gas temperature is extracted and found to increase from 500 K at 20 Torr to 1300 K at 200 Torr. Furthermore, these data are analyzed and compared with a zero-dimensional plasma model and with previous experimental plasma results at 43 GHz.

42 ENGINEERING↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗