Mechanical Behavior of UO 2 at Sub-grain Length Scales: Quantification of Elastic, Plastic and Creep Properties via Microscale Testing

Techniques were developed to measure properties at sub-grain scales using depleted Uranium Oxide (d-UO2) samples heat-treated to obtain different grain sizes and oxygen stoichiometries, through three main tasks: 1) sample processing and characterization, 2) microscale and conventional testing and 3) modeling. Grain size and crystallography were characterized using Scanning Electron Microscopy (SEM), in conjunction with Electron Backscattering Diffraction (EBSD) and Electron Channeling Contrast Imaging (ECCI). Grains were then carefully selected based on their crystallographic orientations to perform ex-situ micromechanical tests with samples machined via Focused Ion Beam (FIB), with emphasis on micro-cantilever bending. These experiments were performed under controlled atmospheres, to insure stoichiometry control, at temperatures up to 700 °C and allowed measurements involving elastic (effective Young’s modulus), plastic (critical resolved shear stresses) and creep (creep strain rates) behavior. Conventional compression experiments were performed simultaneously to compare with the ex-situ measurements and study potential size effects. Modeling was implemented using anisotropic elasticity and inelastic constitutive relations for plasticity and creep based on kinematics and kinetics of dislocation glide that account for the effects of crystal orientation, and stress. The models will be calibrated and validated using the experimental data. This project provided insight on correlations among stoichiometry, crystallography and mechanical behavior in advanced oxide fuels, provided valuable experimental data to validate and calibrate mesoscale fuel performance codes and also a framework to measure sub-grain scale mechanical properties that should be suitable for use with irradiated samples due to small volumes required. The goals and metrics of the ongoing study of thermo-mechanical behavior in depleted uranium dioxide (d-UO 2 ) outlined in this project have been concluded successfully, resulting in: 1) the successful fabrication, processing, and characterization of large-grained samples with various orientations (up to and including single crystals) having stoichiometric and hyper-stoichiometric O/U ratios; 2) formulation, calibration, and validation of a crystal plasticity constitutive model to describe the creep deformation of UO 2 at the sub-grain length scale (single crystal level) at intermediate temperatures; 3) the successful calibration of a crystal plasticity constitutive model to describe the elasto-plastic deformation of microcantilever beams, also at moderate temperatures. Samples were prepared from natural uranium oxide powder of production-quality provided by Areva. The powder was pressed in a die to a pressure of 100 MPa to produce green pellets with no sintering aids, lubricants, or any other additives. The green pellets were then heated up to 1700 °C under ultra-high purity argon atmosphere (~1 ppm O2). The atmosphere was then changed to 79% Argon, 21% O 2 and the temperature was held at 1700 °C for 2 hours to sinter the pellets under oxidative conditions [1] that are known to increase grain growth kinetics in UO 2 [2]. Samples were then cooled down under Ar-4%H2 atmosphere to reduce the samples back to stoichiometric UO 2 . For macro-scale procedures, testing of UO 2 samples with large grains was performed at 1200 °C using a modified load frame capable of applying dead-weight loads to ensure constant stress conditions, while displacement of the sample produced by the applied load was measured with high precision micrometers to obtain strains. Stress steps were used during testing and the strains were monitored to measured creep strain rates under steady state for each level of stress used, so that stress exponents could be obtained. The results of the mechanical testing, along with sample geometry and crystal orientation of the grains in the samples, as well as post-test sample characterization were used to formulate a viscoplastic model to account for steady state (stage II) creep behavior, along with basic assumptions from crystal plasticity and kinematic constraints due to testing fixtures. In the micro-scale, testing of microcantilever beams at temperatures ranging from 25 to 570 °C was performed in-situ with a scanning electron microscope with a special attachment to apply load and measure displacement while the samples were at temperature. The load-displacement curves obtained showed linear behavior before fracture for all temperatures attempted except 570 °C, where clear deviations from non-linearity were observed before fracture. These deviations were consistently observed for all samples tested for a given orientation. A viscoplastic model was used to account for the presence of inelastic strain, along with basic assumptions from crystal plasticity and beam theory. These models were kept as simple as possible, and results from tests performed in a set of samples with a given crystal orientation were used to calibrate the material constants for the model, while results from a different sample set were then used for validation, thus satisfying the conditions of all main tasks within the parameters of this project. Details of these efforts are outlined in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Toward Standardized Microscale Tensile Testing for Two‐Photon Polymerization‐Fabricated Materials in Liquid

Two-photon polymerization (TPP) enables the fabrication of intricate 3D microstructures with submicron precision, offering significant potential in biomedical applications like tissue engineering. In such applications, to print materials and structures with defined mechanics, it is crucial to understand how TPP printing parameters impact the material properties in a physiologically relevant liquid environment. Herein, an experimental approach utilizing microscale tensile testing (μTT) for the systematic measurement of TPP-fabricated microfibers submerged in liquid as a function of printing parameters is introduced. Using a diurethane dimethacrylate-based resin, the influence of printing parameters on microfiber geometry is first explored, demonstrating cross-sectional areas ranging from 1 to 36 μm 2 . Tensile testing reveals Young's moduli between 0.5 and 1.5 GPa and yield strengths from 10 to 60 MPa. The experimental data show an excellent fit with the Ogden hyperelastic polymer model, which enables a detailed analysis of how variations in writing speed, laser power, and printing path influence the mechanical properties of TPP microfibers. The μTT method is also showcased for evaluating multiple commercial resins and for performing cyclic loading experiments. Collectively, this study builds a foundation toward a standardized microscale tensile testing framework to characterize the mechanical properties of TPP printed structures.

mechanical characterization↗

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Laura Wilson↗

Microfluidic Fabrication Techniques for High-Pressure Testing of Microscale Supercritical CO 2 Foam Transport in Fractured Unconventional Reservoirs

Pressure limitations of many microfluidic platforms have been a significant challenge in microfluidic experimental studies of fractured media. As a result, these platforms have not been fully exploited for direct observation of high-pressure transport in fractures. This work introduces microfluidic platforms that enable direct observation of multiphase flow in devices featuring surrogate permeable media and fractured systems. Such platforms provide a pathway to address important and timely questions such as those related to CO 2 capture, utilization and storage. This work provides a detailed description of the fabrication techniques and an experimental setup that may serve to analyze the behavior of supercritical CO 2 (scCO 2 ) foam, its structure and stability. Such studies provide important insights regarding enhanced oil recovery processes and the role of hydraulic fractures in resource recovery from unconventional reservoirs. This work presents a comparative study of microfluidic devices developed using two different techniques: photolithography/wet-etching/ thermal-bonding versus Selective Laser-induced Etching. Both techniques result in devices that are chemically and physically resistant and tolerant of high pressure and temperature conditions that correspond to subsurface systems of interest. Both techniques provide pathways to high-precision etched microchannels and capable lab-on-chip devices. Photolithography/wet-etching, however, enables fabrication of complex channel networks with complex geometries, which would be a challenging task for laser etching techniques. This work summarizes a step-by-step photolithography, wet-etching and glass thermal-bonding protocol and, presents representative observations of foam transport with relevance to oil recovery from unconventional tight and shale formations. In conclusion, this work describes the use of a high resolution monochromatic sensor to observe scCO 2 foam behavior where the entirety of the permeable medium is observed simultaneously while preserving the resolution needed to resolve features as small as 10 μm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale Fracture Testing of HfO2-Si Environmental Barrier Coatings

Environmental barrier coatings (EBCs) play a vital role in protecting advanced turbine components constructed from ceramic matrix composites. EBC performance is evaluated based on many factors such as mechanical and thermal properties and chemical stability. This study focuses on the mechanical properties of individual phases within a HfO2-Si EBC through the combined use of chevron-notched microcantilevers and finite element modeling. The Si- and HfO2-rich phases were found to have fracture toughness K(sub IC) values of 1.36+/-0.07 MPa·m1/2 and 1.99+/-0.36 MPa·m1/2, respectively. Despite irregular notch geometry, calculated K(sub IC) values agreed reasonably with literature values of monolithic samples for the respective phases. The relatively large scatter in the HfO2-rich samples is attributed to heterogeneity in fracture feature size and distribution of the HfO2 and HfSiO4 phases. Comparisons with bulk single-edge V-notched beams suggest bulk behavior is dictated by the fracture behavior of the Sirich phase with no contribution from the HfO2-rich phase.

Robertson, Andrew L.↗

Microscale shear specimens for evaluating the shear deformation in single-crystal and nanocrystalline Cu and at Cu–Si interfaces

Microscale testing has enjoyed significant developments, with the majority of testing focused on tensile/compression type tests and little focus on shear testing. With the recent advances in macroscale shear testing, we developed a novel shear structure for evaluating shear properties of bulk materials and films at the microscale. The shear response in single-crystal copper oriented along the [111] direction was found to have a yield strength of ~180 MPa. Nanocrystalline copper specimens with different orientations showed sensitivity to the film texture with a shear yield strength nearly three times that of single-crystal copper. Shear specimens were fabricated with Cu film–Si substrate interface near the middle of the shear region and compressed to fracture. Here, the shear response showed a mixed behavior of the stiff Si substrate and softer nanocrystalline film and failed in a brittle manner, indicating a response unique to the interface.

36 MATERIALS SCIENCE↗

Microstructural Characterization and Simulation of High Temperature Inelastic Deformation and Fracture of Al-Li 2070

A combined experimental and simulation investigation is carried out to characterize the high temperature deformation behavior of a recently developed Al-Li alloy, AA2070, over a temperature range including typical forging temperatures. Focus is placed on providing explanations for the temperature-dependent plastic and fracture behavior observed for this material using macroscale tensile tests, microscale imaging and analysis, and physics-based micromechanical modeling. It is shown that AA2070 experiences non-monotonic elongation to failure with a rise in temperature. Detailed fractography and microstructural analysis, including dynamic recrystallization analysis, provide insight into this interesting and practically useful behavior. In addition, a validated crystal plasticity model is called upon to explain the unique texture observed in the necked region of the ductile tensile specimen. The insights provided by this investigation will allow improved design of high temperature forming operations for AA2070 and similar alloys which can extend the application of third generation Al-Li alloys.

36 MATERIALS SCIENCE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Microparticle Impact Testing at High Precision, Higher Temperatures, and with Lithographically Patterned Projectiles

Abstract In the first decade of high‐velocity microparticle impact research, hardly any modification of the original experimental setup has been necessary. However, future avenues for the field require advancements of the experimental method to expand both the impact variables that can be quantitatively assessed and the materials and phenomena that can be studied. This work explores new design concepts for the launch pad (the assembly that launches microparticles upon laser ablation) that can address the root causes of many experimental challenges that may limit the technique in the future. Among the design changes contemplated, the substitution of a stiff glass launch layer for the standard elastomeric polymer layer offers a number of improvements. First, it facilitates a reduction of the gap between launch pad and target from hundreds to tens of micrometers and thus unlocks a reproducibility in targeting a specific impact location better than the diameter of the test particle itself (±1.75 µm for SiO 2 particles 7.38 µm in diameter). Second, the inert glass surface enables experiments at higher temperatures than previously possible. Finally—as demonstrated by the launch of thin‐film Au disks—a launch pad made of materials standard in microfabrication paves the way to facile microfabrication of advanced impactors.

36 MATERIALS SCIENCE↗

Automated High‐Throughput Fatigue Testing of Freestanding Thin Films

Abstract Mechanical testing at small length scales has traditionally been resource‐intensive due to difficulties with meticulous sample preparation, exacting load alignments, and precision measurements. Microscale fatigue testing can be particularly challenging due to the time‐intensive, tedious repetition of single fatigue experiments. To mitigate these challenges, this work presents a new methodology for the high‐throughput fatigue testing of thin films at the microscale. This methodology features a microelectromechanical systems‐based Si carrier that can support the simultaneous and independent fatigue testing of an array of samples. To demonstrate this new technique, the microscale fatigue behavior of nanocrystalline Al is efficiently characterized via this Si carrier and automated fatigue testing with in situ scanning electron microscopy. This methodology reduces the total testing time by an order of magnitude, and the high‐throughput fatigue results highlight the stochastic nature of the microscale fatigue response. This manuscript also discusses how this initial capability can be adapted to accommodate more samples, different materials, new geometries, and other loading modes.

Barrios, Alejandro↗

Ultrastiff, Strong, and Highly Thermally Conductive Crystalline Graphitic Films with Mixed Stacking Order

A macroscopic film (2.5 cm × 2.5 cm) made by layer-by-layer assembly of 100 single-layer polycrystalline graphene films is reported. The graphene layers are transferred and stacked one by one using a wet process that leads to layer defects and interstitial contamination. Heat-treatment of the sample up to 2800 °C results in the removal of interstitial contaminants and the healing of graphene layer defects. The resulting stacked graphene sample is a freestanding film with near-perfect in-plane crystallinity but a mixed stacking order through the thickness, which separates it from all existing carbon materials. Macroscale tensile tests yields maximum values of 62 GPa for the Young's modulus and 0.70 GPa for the fracture strength, significantly higher than has been reported for any other macroscale carbon films; microscale tensile tests yield maximum values of 290 GPa for the Young's modulus and 5.8 GPa for the fracture strength. The measured in-plane thermal conductivity is exceptionally high, 2292 ± 159 W m -1 K -1 while in-plane electrical conductivity is 2.2 × 10 5 S m -1 . Finally, the high performance of these films is attributed to the combination of the high in-plane crystalline order and unique stacking configuration through the thickness.

36 MATERIALS SCIENCE↗

Development of Ultra Small Scale Mechanical Testing and Localized He Implantation for Nuclear Applications

Mechanical properties degradation of components deployed in nuclear applications has been a concern since the deployment of first generation nuclear power plants. Radiation damage along with environmental degradation, elevated temperatures, and long term deployment of nuclear structures pose a challenging environment for all materials in these applications. Traditionally, the mechanical properties are assessed by standardized macroscopic testing methods. While those are providing engineering relevant data these techniques do have limitations, especially on reactor irradiated materials, due to the large size of the samples. Limitations on the amount of radioactivity of large samples must be applied for research applications as they are conducted at universities. In addition it can be difficult to retrieve sufficiently large amounts of material from an operating reactor component. Therefore smaller sample sizes are desirable and reduce the amount of radioactive material which needs to be handled or material which needs to be retrieved. In addition, the number of tests which can be performed on materials irradiated in a test reactor program is limited due to limited space in specific dose and temperature positions. Downsizing of the mechanical test can overcome this issue and perform more tests on the same amount of irradiated materials, reducing the statistical uncertainties. In addition, smaller scale samples allow access to specific regions of interest in a material or component, be it the zone in front of a crack tip or the sampling of very small components like springs or welded areas. In addition ion beam irradiation has become an integral part of nuclear materials research to enhance the understanding of radiation damage in materials in a time and cost effective fashion. The drawback of ion beam irradiation is the small penetration depth of the ions into the material making localized microstructural characterization as well as small scale mechanical testing necessary. Another more fundamental motivation is the fact that since the beginning of electron microscopy, one has been concerned about imaging and quantifying defects in materials. Multiscale tools to image a large range of radiation induced defects have been established starting from atom probe tomography to transmission electron microscopy, up to scattering techniques. Mechanical testing, however, has always been performed on a large scale, and an attempt to match the same scale where a defect is observed with the materials' mechanical property response has not yet been realized. However, the question of separate effects testing on specific radiation induced defects remains and is an additional driving force for small scale mechanical testing. In this work we present an approach for small scale mechanical testing in irradiated materials and the variety of possible test methods developed today. We also present recent efforts of performing localized ion beam implantation to achieve a number of different doses in the same region of interest enhancing comparability and quantification of observed phenomena. It is the intention to give the reader an overview of the different microscale mechanical testing techniques possible today as well as an introduction of a novel ion beam irradiation method using a newly established capability. In this paper we can't discuss all aspects of all small scale mechanical testing of irradiated materials However, It does give an overview over the techniques enabled due to recent effort and enhanced instrument capability. While indentation or micro compression testing has been performed previously tensile testing and ion beam irradiation using the He ion beam microscope are novel approaches not attempted previously. (authors)

36 MATERIALS SCIENCE↗

Brittle-to-Ductile Transition Temperature Decreases at the Microscale in Muscovite Mica

Characterizing the structural and chemical transitions of muscovite mica across various scales and thermal profiles is essential for ensuring the reliability of high-voltage power insulation, aerospace thermal barriers, and nanoscale semiconductor substrates under extreme operational stress. Here, we investigate notch fracture toughness $K^{n}_{Ic}$ of muscovite mica as a function of feature size w and temperature T with microscale shear testing. $K^{n}_{Ic}$ decreased and then stayed constant as w increased, likely from fabrication-induced changes to the microstructure and roughness. Moreover, $K^{n}_{Ic}$ initially decreased and then increased as temperature T increased, with the reversal in trend indicative of a brittle-to-ductile transition. Complementary Raman spectroscopy and molecular dynamics showed that the observed trends were due to an increase in bond lengths and a decrease in critical stresses/strains. In comparing the microscale results to macroscale counterparts, it was surmised that the decrease in brittle-to-ductile transition temperature was due to an increase in the dehydroxylation rate.

DelRio, Frank W. [Sandia National Laboratories (SN↗