Effect of magnetic field on the performance of millimeter-wave detectors using bulk InSb.
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Infrared polarimetry pictures of star forming regions were obtained. The magnetic field structure of the disk is examined. The design of the infrared telescope is described.
The present invention relates to sub-millimeter wave frequency heterodyne imaging systems. More specifically, the present invention relates to a sub-millimeter wave frequency heterodyne detector system for imaging the magnitude and phase of transmitted power through or reflected power off of mechanically scanned samples at sub-millimeter wave frequencies.
The present invention relates to sub-millimeter wave frequency heterodyne imaging systems. More specifically, the present invention relates to a sub-millimeter wave frequency heterodyne detector system for imaging the magnitude and phase of transmitted power through or reflected power off of mechanically scanned samples at sub-millimeter wave frequencies.
Thermal Kinetic-Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of millimeter-wave instruments. In this paper, we first discuss the expected noise sources in TKIDs and derive the limits where the phonon noise contribution dominates over the other detector noise terms: generation–recombination, amplifier, and two-level system noise. Second, we characterize aluminum TKIDs in a dark environment. We present measurements of TKID resonators with quality factors of about 10 5 at 80 mK. We also discuss the bolometer thermal conductance, heat capacity, and time constants. These were measured by the use of a resistor on the thermal island to excite the bolometers. These dark aluminum TKIDs demonstrate a noise equivalent power, NEP = 2 × 10 − 17 W / Hz , with a 1 / f knee at 0.1 Hz, which provides background noise limited performance for ground-based telescopes observing at 150 GHz.
Equivalent circuit evaluation of theoretical potential and limitations of millimeter wave semiconductor diode detectors, mixers and frequency multipliers
Receiver techniques and detectors for use at millimeter and submillimeter wavelengths
Self-similar antennas offer extremely broadband functionality and easily scalable designs. Self-similar designs with a four-arm layout are also suited for dual polarization through excitations of opposing arms, although there has only been limited use of them for millimeter-wave detectors. These antennas have been used for measurements of the cosmic microwave background (CMB), which encompass a wide frequency range and are now actively focusing more on polarization anisotropies. Here, we analyze multiple planar self-similar antenna designs with simulations in high-frequency structure simulator and ongoing physical testing. They all exhibit broadband operation between 130 and 230 GHz and can couple to both linear polarizations through the previously mentioned four-arm symmetry. Furthermore, simulations include each antenna design coupled to an extended hemispherical, AR-coated lenslet. From these, a basic bowtie-like arm design produced minimal polarization wobble with moderate beam efficiency, while a hybrid trapezoidal design provided high beam efficiency with small polarization wobble. Current fabrication versions of each are being tested, coupled to multichroic microwave kinetic inductance detectors. These planar self-similar antennas, when implemented in CMB and other detectors, could improve observations while simultaneously simplifying fabrication and detector layout.
Description of a high-purity n-type indium antimonide sample mounted in a reentrant cavity, cooled to 4.2 K, and operated as a millimeter-wave detector. The scheme utilizes a down-conversion process, and free-carrier absorption is the mechanism responsible for the detection process. Power applied at the millimeter-wave frequency causes a change in the material conductivity, which in turn causes a change in the X-band power absorption. Cavity perturbation techniques are used to analyze the scheme. The detector was operated successfully at frequencies between 35 and 150 GHz with no long-wavelength or short-wavelength cutoff observed. The scheme offers a fast, highly sensitive, and rugged detector with low conversion loss.
We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.
Explore the source record for details and available documents.
Millimeter and submillimeter wave receiver techniques and detectors
Receivers and detectors for submillimeter wavelengths
Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.
Receiver techniques and detectors for use at millimeter and submillimeter wavelengths, and excitation cross sections for argon II, krypton II, and neon II gas lasers
The 31 and 92 GHz measurements of the superconductor-Schottky diode extended to millimeter wavelengths by a redesign of the semiconductor interface are reported. Diodes were fabricated by pulse electroplating Pb on 2 x 10 to the 19th/cu cm p-Ga-As etched with HCl; a thin Au overplate is deposited to protect the Pb film from degradation and to improve its lifetime. The noise performance was almost ideal at 31 and 92 GHz; it was concluded that this diode is a quantum-limited-detector at 31 GHz, with excessive parasitic losses at 92 GHz.
Explore the source record for details and available documents.
Receiver techniques and detectors for use at millimeter and submillimeter wavelengths in radio astronomy