Search NASA⌕ Search

SEARCH · Search NASA

Results for “minor isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ATONA TE-TIMS of minor uranium isotopes (FY25 Mid-Year Report)

Isotopic measurements of the minor isotopes of uranium ( 233 U, 234 U, 236 U) are indispensable measures for material accountability and processing history but can be particularly challenging to accurately measure due to the very low abundance of the minor isotopes relative to 238 U, or 235 U in the case of highly enriched uranium (HEU). The goal of this project is to quantify detection limits for minor uranium isotope species at environmental levels (e.g 236 U/ 238 U < 10 -7 ) utilizing an ATONA-outfitted instrument and the Total Evaporation Thermal Ionization Mass Spectrometry (TE-TIMS) method. In the first half of Fiscal Year 2025, we set out to identify a suitable experimental material (Task 1) and to optimize our TE-TIMS measurement routine (Task 2). We have successfully identified a material and are in the process of getting an aliquot shipped to LANL. Simultaneously, we began working on our measurement routine utilizing CRM 112A. The results of each task are discussed in detail below.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fitting $\overline{ν}$ for Minor Pu Isotopes

After successful fitting of prompt ν for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we have moved on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. Initially, we had planned to mitigate these challenges—and provide consistency within CGMF—by taking a stepped approach to the optimization. Continuing from the 239 Pu work, we would then fit 241Pu(n,f) $\overline{ν}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we could consistently optimize 240 Pu(n,f) $\overline{ν}$. Following that step, we would move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We were also able to develop systematics for the CGMF input parameters along the Pu isotopic chain. However, after studies in the beginning of FY23, where we found reasonable agreement between CGMF and experimental prompt neutron multiplicities for 238−242 Pu, using a compound mass dependent parametrization from, and from discussions with I. Stetcu and P. Talou, we instead performed the evaluation of all five isotopes simultaneously. For all parameters in CGMF, they are either the same for each compound nucleus, or have a dependence on the compound mass. The details of these updates are given in. This report builds upon those details. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will show in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points. The evaluation is detailed in Section 4, and the comparison between CGMF calculations using the evaluated parameters and other prompt observables besides average neutron multiplicity are discussed in Section 2.2. Finally, we present conclusions and future work in Section 5.

07 ISOTOPE AND RADIATION SOURCES↗

Fitting $\overline{\nu}$ for minor Pu isotopes

After successful fitting of prompt $\overline{\nu}$ for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we will move on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. To mitigate these challenges— and provide consistency within CGMF—we will take a stepped approach to the optimization. Continuing from the 239 Pu work, we will then fit 241 Pu(n,f) $\overline{\nu}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we can consistently optimize 240 Pu(n,f) $\overline{\nu}$. Following that step, we will move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We will possibly also be able to develop systematics for the CGMF input parameters along the Pu isotopic chain. This work can serve as a guide to broadening the reactions available in CGMF. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will shown in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points.

07 ISOTOPE AND RADIATION SOURCES↗

Consistent $\overline{ν}$ evaluation for minor U isotopes with $\tt{CGMF}$

Following several successful prompt $\overline{ν}$ evaluations using $\tt{CGMF}$, including consistent evaluations for minor Pu isotopes, we detail in this report our efforts to perform a consistent $\overline{ν}$ evaluation for minor U isotopes during FY25. Although we have not yet produced a finalized evaluation, we present the progress that we have made towards such an evaluation for 232,233,234,236,237,239 U prompt $\overline{ν}$. Our milestone explicitly calls out evaluations for 233 U, 234 U, and 236 U, however, to better constrain the model with reliable experimental $\overline{ν}$ data, we also include 235 U and 238 U in the evaluation procedure. Then, we additionally produce evaluations for 232 U, 237 U and 239 U $\overline{ν}$ as a byproduct. Elsewhere, we will report our efforts on a stand-alone 233 U $\overline{ν}$ evaluation. This report is organized in the following manner. In Sec. 2, we briefly outline the updates to CGMF that were needed to be able to calculate all of these minor U fission reactions. The experimental data overview is given in Sec. 3. The evaluation methodology and results are presented in Secs. 4 and 5, respectively. Finally, we conclude and outline work for FY26 in Sec. 6.

07 ISOTOPE AND RADIATION SOURCES↗

Consistent $\overline{ν}$ evaluation for minor Pu isotopes with CGMF

This report follows up on the evaluation work done in 2023 where we developed a procedure and performed the first consistent evaluation of the average prompt neutron multiplicity for minor Pu isotopes, including 238,240-242 Pu, using CGMF. Details on the necessary updates to the release version of CGMF, the experimental data and experimental uncertainty quantification that went into the evaluation, and this first evaluation effort are documented in and will not be repeated in this report. Instead, we discuss here the further investigations into the CGMF model space to improve the evaluation results from FY23. Additionally, we note that these evaluation results have been transformed into the ENDF format for mean values and covariances, and validation with critical assemblies has been performed; that work is documented elsewhere. In this short report, we discuss the updated evaluation efforts performed during FY24 in Sec. 2, show results from CGMF for other prompt fission observables in Sec. 3, and then briefly conclude in Sec. 4.

07 ISOTOPE AND RADIATION SOURCES↗

Calculations of enrichment cascade performance using enrichment probabilities – a new method

A new method for calculating the performance of uranium enrichment cascades is presented. The method assigns a unique “enrichment probability” for each isotope to move up or down from the basic enrichment unit, allowing independent material balance calculations for each isotope. The formulation is much simpler than previous methods, which rely on isotopic ratios, and this method can be used when previous methods fail. This method gives the same results as published cases for 235 U enrichment and also gives good agreement with published data on minor isotopes. Some comparisons with measured data and other calculations are given. One case shows that the maximum 235 U enrichment that can be obtained by enrichment of reprocessed uranium (0.02% 234 U initial) is 82%. Another example shows a large difference in the minor isotopic content of material enriched in batches compared to continuous enrichment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Integration of Online Cross-Section Generation Capability with Depletion and Transient Solvers in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE)-based reactor multiphysics analysis application jointly developed by Argonne and Idaho National Laboratories under the DOENE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In FY25, an online crosssection generation capability based on the Self-Shielding Application Programming Interface (SSAPI) was demonstrated for TRISO-fueled reactor problems under steady-state conditions. This fiscal year, that capability was extended to support depletion and transient multiphysics calculations, enabling high-fidelity analyses that generate self-shielded cross sections on the fly from the actual evolving composition and temperature states rather than from pre-tabulated libraries. For depletion, a two-way coupling was established in which SSAPI computes compact-averaged self-shielded cross sections that the depletion solver then uses to advance the Bateman equations, with the updated compositions returned to SSAPI at each step; the depletion module was refactored to support both library-based and SSAPI-based cross sections, and additional logic was added to track daughter isotopes and to exclude minor isotopes for efficiency. For transient analysis, the SSAPI multigroup library was extended with the kinetics data required for time-dependent calculations, the Improved Quasi-Static (IQS) scheme was coupled with SSAPI, and several supporting capabilities were implemented, including a self-shielding treatment that lets control rods and drums move within a self-shielded model, which had previously been impossible and had ruled out rod- and drum-movement transients with on-the-fly cross sections altogether, a new mixing scheme for delayed-neutron precursor decay constants, a checkpoint-based restart workflow, and performance improvements such as pointwise cross-section interpolation and the bypassing of unnecessary Dancoff factor calculations. The implemented capabilities were verified against Serpent Monte Carlo solutions. For depletion, a prismatic pin-cell problem based on a Next Generation Nuclear Plant (NGNP) Very High Temperature Reactor benchmark showed excellent agreement, with eigenvalue differences within 200 pcm over the entire burnup range (up to 140 MWD/kgU) and fission-product and actinide inventories agreeing to within 0.8% and 2.5%, respectively; a heat-pipe microreactor assembly problem with a much higher fuel loading confirmed the same behavior and quantified the bias introduced when the multigroup equivalence effect is neglected. For transient analysis, a pin-cell problem with a step reactivity insertion and temperature feedback reproduced the analytically expected asymptotic power and showed close agreement between the direct and IQS solutions, and a two-dimensional microreactor core problem with control-drum rotation exercised the new moving-drum self-shielding treatment and demonstrated successful coupling of the online crosssection generation with both the direct and IQS transient methods. The capability was further exercised on a full-core pebble-bed problem, in which Griffin was coupled with the System Analysis Module (SAM) to simulate load-following operation of the gPBR with the Doppler feedback resolved at the TRISO fuel kernel temperature. These developments in Griffin provide a convenient, high-fidelity approach to cross-section generation for advanced thermal reactors with geometrically complex and highly heterogeneous configurations, including TRISO-fueled prismatic and pebble-bed systems, and support steady-state, depletion, and transient multiphysics calculations. They also enable self-shielded cross sections to be evaluated directly at the actual coupled state of the system, thereby establishing a foundation for high-fidelity, fully coupled multiphysics analysis of advanced reactors

Park, H.↗

Status Report on Characterization of High Burnup Fuel with Advanced Nondestructive Pulsed Neutron PIE

Characterizing irradiated or spent nuclear fuels with pulsed neutron techniques provides microstructural data such as phase fractions as well as crystallographic data, e.g. lattice parameters, from diffraction analysis. Diffraction characterization is complemented by spatially resolved mapping of isotope densities from energy-resolved neutron imaging, in particular neutron absorption resonance imaging, and overall bulk isotope assay with better sensitivity for minority isotopes from neutron absorption resonance spectroscopy without spatial resolution. Furthermore, after characterization at ambient condition, heating of irradiated or spent fuel will allow to characterize differences of e.g. lattice thermal expansion or phase transition temperature and kinetics compared to fresh fuel as well as enable the study of disappearance of irradiation defects. This data enables benchmarking of predictions of properties of irradiated fuels for which otherwise experimental data is sparse. The effort described here strives to characterize a section cut from a high-burnup fuel. Volumes smaller than entire fuel pellets or rodlets as proposed here, e.g. sections cut from a fuel pellet, to pave the way to characterize entire pellets or rodlets in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status of the n+ 234 U evaluation in the resolved resonance region (*), (**)

In natural uranium, the 234 U isotope represents only 0.0055%, however, this minor isotope can affect highly enriched uranium metal benchmark calculations. In fact, enriched uranium contains more 234 U than natural uranium as the result of the uranium enrichment process. Therefore, the n+ 234 U nuclear data evaluation is one of the milestones of the APPENDIX B within the Nuclear Criticality Safety Program (NCSP).

AMPX↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

$\overline{TKE}$ Parameterization and $\bar{v}$ Uncertainty Analysis for CGMF

Previous work was performed on tuning CGMF parameters for 235 U, 238 U, and Plutonium isotopes. Now work is being done to tune minor uranium isotopes. However, uranium isotopes like 232 U and 236 U have almost no experimental data. We are applying cross-isotope models to extrapolate and tune CGMF on isotopes that lack experimental data. There exist several internal CGMF physics quantities that affect the output of CGMF—multi-chance fission probability, excitation energy sharing, spin-cutoff factor, spin scaling, and fragment total kinetic energy to name a few. The mean fragment total kinetic energy, $\overline{TKE}$, is particularly interesting because of its strong anti-correlation with $\bar{v}$. We are most interested in the mean fragment total kinetic energy before neutron emissions. $\overline{TKE}$ is assumed to be pre-neutron emission unless otherwise stated. Currently in CGMF, the $\overline{TKE}$ model for 233,234,235,238 U are tuned independently to reproduce ν for the associated isotopes. In this report, we will tune a cross-isotope $\overline{TKE}$ model to experimental $\overline{TKE}$ data for 232,233,234,235,236,238 U. Because of the unreliable and sparse nature of $\overline{TKE}$ experimental data, future work will use more reliable experimental $\bar{v}$ data to infer the $\overline{TKE}$ model (and likely other internal CGMF parameters) for uranium isotopes. Such work has been performed previously using a sensitivity analysis and Kalman filter methods.

07 ISOTOPE AND RADIATION SOURCES↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Formatting and V&V of Consistent 238,240−24 2Pu $\overline{v}_p$ Evaluated Mean Values and Covariances

This report is in answer to the Nuclear Criticality Safety Program FY24 quarter 4 milestone that requires: “Format and V&V nu-bar means and covariances” for 238,240-242 Pu average prompt fission neutron multiplicities, $\overline{ν}$ p , that were obtained by a consistent evaluation leveraging the fission-event generator CGMF and a detailed uncertainty quantification of experimental data. It is described how nuclear data mean values and covariances were formatted using ENDFtk. Implementing the new 238,240-242 Pu $\overline{ν}$ p into the ENDF/B-VIII.1β 4 library leads to only small overall changes in criticality values of the Jezebel, Dirty Jezebel, Jupiter-001, Jupiter-002, EUCLID 3x2 and EUCLID 8x1 critical assemblies. Simulated k eff uncertainties due to $\overline{ν}$ p covariances change only little if cross-isotope covariances are considered or not for those assemblies with low percentage content of minor Pu isotopes. However, for the Dirty Jezebel critical assembly, that has a sizeable 240 Pu and non-negligible 241 Pu content, the simulated k eff uncertainties due to considering or neglecting cross-isotope $\overline{ν}$ p covariances is 443 versus 374 pcm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of Uranium Isotope Impacts

This report examines the benefits and challenges associated with recycling recovered uranium (RU) from the used nuclear fuel (UNF) discharged from a once-through sodium-cooled fast reactor (SFR) with high-assay low-enriched uranium (HALEU) which has a higher residual U-235 content in the RU. However, there are three minor uranium isotopes that influence the value of the RU. There will be trace quantities of U-232 in RU, which can increase dose rates and, in turn, increase the cost of fuel fabrication. Additionally, the U-234 and U-236 isotopes are found in higher concentration in RU than in NU, and act as neutron poisons, requiring higher U-235 concentrations to compensate for the neutron poisoning effects of these isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes

Here, the microextraction sampling technique was integrated with triple quadrupole–inductively coupled plasma–mass spectrometry (TQ–ICP–MS) to directly sample and measure the isotopic compositions of uranium (U) and plutonium (Pu) from cotton swipes. Once extracted, the U/Pu were directed into the TQ–ICP–MS instrument for isotopic determination. Carbon dioxide (CO 2 ) and helium (He) gases were delivered to a collision reaction cell within the ICP–MS system for ion separation. The CO 2 reacts with the U + forming UO + which is ultimately separated from the Pu + ions of interest in the third quadrupole. This study demonstrates direct liquid extraction of U/Pu from a solid surface and subsequent measurement by TQ–ICP–MS in <60 s. Flow rates were optimized (0.3 mL min –1 CO 2 and 5 mL min –1 He) in the reaction cell of the ICP–MS system to maximize the Pu signal while minimizing U interferences (i.e., 238 U + tail and 238 UH + ) at m/z 239. Low levels of Pu (~2 pg) were deposited on a cotton swipe along with U at concentrations ranging from 20 to 200 ng. The 240 Pu/ 239 Pu ratio was measured with <7% relative difference from the certified value at all U concentrations. Major and minor U isotope ratios were also measured with <4% relative difference. This highlights that the microextraction–TQ–ICP–MS method can extract a mixed U/Pu sample directly from a cotton swipe and measure both isotopic systems without chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗