Search NASA⌕ Search

SEARCH · Search NASA

Results for “mode transition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved understanding of the hot cathode current modes and mode transitions [Mechanism of the hot cathode current mode transitions]

Hot cathodes are crucial components in a variety of plasma sources and applications, but they induce mode transitions and oscillations that are not fully understood. It is often assumed that negatively biased hot cathodes have a space-charge limited (SCL) sheath whenever the current is limited. Here, we show on theoretical grounds that a SCL sheath cannot persist. First, charge-exchange ions born within the virtual cathode (VC) region get trapped and build up. After the ion density reaches the electron density at a point in the VC, a new neutral region is formed and begins growing in space. In planar geometry, this 'new plasma' containing cold trapped ions and cold thermoelectrons grows towards the anode and fills the gap, leaving behind an inverse cathode sheath. This explains how transitions from temperature-limited mode to anode glow mode occur in thermionic discharge experiments with magnetic fields. If the hot cathode is a small filament in an unmagnetized plasma, the trapped ion region is predicted to grow radially in both directions, get expelled if it reaches the cathode, and reform periodically. Filament-induced current oscillations consistent with this prediction have been reported in experiments. Here, we set up planar geometry simulations of thermionic discharges and demonstrate several mode transition phenomena for the first time. Lastly, our continuum kinetic code lacks the noise of particle simulations, enabling a closer study of the temporal dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Universal Passive Synchronization Method for Grid-Forming Inverters Without Mode Transition

Power systems are transforming with increasing levels of inverter-based resources (IBRs). This transformation requires critical roles of grid-forming (GFM) inverters replacing synchronous generators for bulk power system stabilization and ancillary services, also allowing flexible power system operation, such as microgrid that is operated by multiple GFM IBRs to achieve system resilience against contingencies. To realize the resilient power systems allowing flexible in-and-out operation of GFM IBRs potentially programmed with different primary controls, a synchronization method universally applicable, i.e., independent of control types, would be beneficial to ease the integration process, but it has not been actively studied. To fill the gap, this paper proposes a universal synchronization method that achieves a passive synchronization to enable a smooth transition in a grid with off-nominal system parameters, i.e., voltage and frequency. The logic proposed requires no modification on the primary control, thus applicable to any type of GFMs with a voltage reference input. To validate the concept, a simulation of an IEEE 13-bus benchmark system modified with 3 GFM inverters is presented. It simulates an inverter-driven black start scenario in which GFM inverters autonomously turn on and connect to the grid under heavy loading, using the synchronization logic. The case study demonstrates that GFM inverters can tune their voltage reference to smoothly synchronize without severe transients, and contribute to a seamless black start of the grid under unbalanced load conditions. Two GFM methods - Droop and dispatchable virtual oscillator control - are used for the demo to validate feasibility and interoperability of the passive synchronization.

black start↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Mode transitions and spoke structures in E × B Penning discharge

Two-dimensional particle-in-cell simulations in the (radial-azimuthal) plane perpendicular to the axial direction of a cylindrical $E$ x $B$ Penning discharge are presented. The low-pressure discharge is self-consistently supported by plasma ionization from the electron beam injected axially, along the direction of the external magnetic field. It is shown that with the increasing strength of the external magnetic field, the discharge undergoes a sequence of transitions between several azimuthal modes. Azimuthal m > 1 spiral arm structures are excited at low magnetic field values as plasma confinement improves and the radial density profile becomes peaked. With a larger field, spiral arms with m > 1 are replaced by the m = 1 spoke mode, most clearly seen in plasma density. A transition from spiral arms to the spoke regime occurs when the plasma potential in the center changes from weakly positive (or zero) to negative. Further increase in the magnetic field results in a well-developed m = 1 spoke mode with additional small-scale higher-frequency m > 1 structures inside and around the spoke. It is shown that while ionization and collisions affect some characteristics of the observed fluctuations, the basic features of the spoke and m > 1 spiral structure remained similar without ionization. The role of energy conservation in small-scale high-frequency modes and spoke dynamics is discussed. It is demonstrated that in regimes with the m = 1 spoke mode, additional m = 4 harmonics of the ion and electron fluxes to the wall appear due to the square boundary. The frequency of the m = 1 mode is weakly affected by the geometry of the boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of the Inter-Tube Flow Mode Transitions in the Evaporators of Multi-Effect Thermal Desalination Plants

Water is one of the most stressed resources on the planet. The limited availability of fresh water and the high cost of transportation have led to an increased interest in water desalination technologies. The two main categories of desalination techniques are membrane desalination and thermal desalination. Membrane technologies include pressure driven and electrical driven membranes. On the other hand, thermal desalination includes: multi-effect desalination (MED), multi-stage flash (MSF) desalination, and mechanical vapor compression desalination. Multi-effect desalination plants are usually made of a series of evaporators (also known as effects). In each effect, hot steam flows inside the tubes and evaporates the seawater that falls on the outside of the tubes. The vapor formed at each effect flows to the next effect and acts as the heating medium for the falling seawater. The prevailing flow mode of the falling seawater (i.e. droplet, jet, or sheet) influences heat and mass transfer as well as dry out in the evaporators of Multi-Effect Desalination (MED) plants. The objective of this paper is to predict and discuss the prevailing falling film flow modes in the evaporators of MED plants, under different operating conditions. The paper demonstrates the transitional Reynolds numbers between the main falling film modes for seawater. This closes a gap in the literature where there is a dearth of mode transition data for seawater. The effect of fluid properties and tube geometry on the transitions is discussed in details. As a result, the accuracy of the predicted transitional Reynolds numbers is evaluated via uncertainty quantification techniques.

availability↗

Grid-forming Control of Single- and Two-Stage Solar PV Systems with Mode Transition

Legacy power systems once dominated by con-ventional synchronous machines are transitioning into systems driven by fast-acting power-electronic converters that integrate renewable resources. The majority of integrated renewables such as PV and wind bring down system inertia and can cause stability issues due to their volatile nature. The state-of-the-art grid-forming (GFM) control is proven to enhance system inertia and stability in low-inertia systems. However, most of the existing GFM inverters are applied for battery systems, which are much more expensive than PV. Motivated by this, in this paper we propose a holistic grid-forming (GFM) control strategy for PV systems without the need of energy storage. The proposed strategy is developed on the secondary level of the grid-forming control that enables the PV inverter to operate smoothly among islanded, synchronization, GFM, and limited grid-forming (LGF) modes. The practical criteria for determining the operation modes are established and implemented based on the grid operation scenarios. Here, the proposed design is successfully validated by case studies with a laboratory prototype using Siemens Software Defined Inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical analysis of magnetic divertor configuration influence on H-mode transitions

DIII-D plasmas are compared for two upper divertor configurations: with the outer strike point on the small angle slot (SAS) divertor target and with the outer strike point on the horizontal divertor target (HT). Scanning the vertical distance between the magnetic null point and the divertor target over a range 0.10–0.16 m is shown to increase the threshold power, $P_\mathrm{th}$, and edge plasma power, $P_\mathrm{Loss},$ for the low-to-high confinement (L–H) and H–L transitions respectively, by up to a factor of 1.4. The X-point height scans were performed at three L-mode core plasma line average electron densities, $\bar{n}_\mathrm{e} = $ 1.2, 2.2 and 3.6 $\times 10^{19}\,\mathrm{m}^{-3}$, to investigate the density dependence of divertor magnetic configuration influence on $P_\mathrm{th}$. The X-point height, $Z_\textrm{x-pt}$, was further extended across the range 0.16–0.22 m with the more open HT divertor configuration, for which a clear decrease in $P_\mathrm{th}$ with increasing $Z_\textrm{x-pt}$ is observed. The dependence of $P_\textrm{th}$ on divertor magnetic geometry is further investigated using a time-dependent probability density function (PDF) model and information geometry to elucidate the roles played by pedestal plasma turbulence and perpendicular velocity flows. The degree of stochasticity of the plasma turbulence is observed to be sensitive to the plasma heating rate. The calculated square of the information rate shows changes in the relative density fluctuations and perpendicular velocity PDFs begin 2–5 ms prior to the L–H transition for three plasmas; providing a crucial measurement of the dynamic timescale of external transport barrier formation. Additionally, both information length and rate provide potential predictors of the L–H transition for these plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beyond DERMS: Demonstration of Automated Grid Services, Mode Transition, and Resilience

This report describes the results of more advanced use cases including Ancillary Services, Black-sky-day operation, and Mode Switching from Phase 3 of the “Beyond DERMS” project aiming to build, deploy, and demonstrate a holistic platform that supports the integrated operation and planning of future power distribution networks with bi-directional power flows, many diverse distributed energy resources (DERs), and inverter-based resources. These test results demonstrated how a Beyond DERMS platform can fuse together AMI, SCADA, and DER data to provide a utility with deep insights into distribution network operations and planning, extending the value of DERMS and BTM DER resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Four-Switch Buck-Boost Converter Based on Model Predictive Control with Smooth Mode Transition Capability

Four-switch buck-boost converter supports both voltage step-up and step-down functionalities, but it suffers from mode transfer challenge that would need reliable mode detection when designed to operate in multi different modes. In this paper, a novel control method based on model predictive current control is proposed for such converter with inherent smooth mode transfer capability without extra design on mode detection and transfer scheme. Modulator and mode detection are replaced by an optimization process through cost function. This largely simplifies the design and makes it easily implemented. Therefore, seamless transfer between buck and boost modes is achieved with many other system level benefits. Simulation and experimental results are provided to verify the effectiveness of proposed method for the four-switch buck-boost converter.

42 ENGINEERING↗

Recent progress towards a physics-­based understanding of the H-­mode transition

Results from recent experiment and numerical simulation point towards a picture of the L-H transition in which edge shear flows interacting with edge turbulence create the conditions needed to produce a non-zero turbulent Reynolds stress at and just inside the LCFS during L-mode discharges. This stress acts to reinforce the shear flow at this location and the flow drive gets stronger as heating is increased. The L-H transition ensues when the rate of work done by this stress is strong enough to drive the shear flow to large values, which then grows at the expense of the turbulence intensity. The drop in turbulence intensity momentarily reduces the heat flux across the magnetic flux surface, which then allows the edge plasma pressure gradient to build. A sufficiently strong ion pressure gradient then locks in the H-mode state. These results are in general agreement with previously published reduced 0D and 1D predator prey models. An extended predator–prey model including separate ion and electron heat channels yields a non-monotonic power threshold dependence on plasma density provided that the fraction of heat deposited on the ions increases with plasma density. Possible mechanisms to explain other macroscopic transition threshold criteria are identified. A number of open questions and unexplained observations are identified, and must be addressed and resolved in order to build a physics-based model that can yield predictions of the macroscopic conditions needed for accessing H-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Empirical Characterization and Modeling of Cohesive – to – Adhesive Shear Fracture Mode Transition due to Increased Adhesive Layer Thicknesses of Fiber Reinforced Composite Single – Lap Joints

Here, to ensure a strong adhesive bond, most standards and adhesive manufacturers specify a maximum adhesive gap of 1 mm when bonding fiber reinforced composite structures. In manufacturing large components, such as joining two halves of wind turbine blades, meeting this gap tolerance specification is impractical; gaps larger than 10 mm are common in large adhesively bonded composite structures using state-of-the-art manufacturing techniques. Currently, there is a lack of fundamental understanding of the failure mechanics of adhesive gaps larger than 3 mm. To create such understanding, glass fiber - acrylic thermoplastic composite panels bonded using different epoxy adhesives within single-lap joint samples with adhesive thicknesses of 0.1 mm, 0.3 mm, 1 mm, 3 mm, 5 mm, and 10 mm were sheared to failure. A transition from cohesive to adhesive failure was observed to occur about 1 mm to 3 mm joint thicknesses. Plotting the shear stress normalized by the ratio of the joint width to thickness as a function of the joint thickness normalized by the joint length is shown to result in the ability to fit simple empirically derived models of the cohesive-to-adhesive failure transition, regardless of the adhesive. Furthermore, using these normalized variables, all the observed cohesively failed specimens collapse to a single master curve, as do the adhesively failed specimens.

36 MATERIALS SCIENCE↗

Turbulence characteristics and flow dynamics impacts on the H-mode transition in favourable magnetic geometry with lower power threshold

We report the L-H transition power threshold (P LH ) in favourable magnetic geometry (ion ∇B drift pointing towards X-point) is much lower than in the unfavourable magnetic geometry (ion ∇B drift pointing away from X-point) on multiple tokamaks. In a systematic experiment on DIII-D, the ion ∇B drift direction was changed continuously from the unfavourable to favourable configuration during plasma discharges. During such process, the input neutral beam power was kept constant at a value that was above P LH for favourable configuration, but lower than P LH for unfavourable configuration. Toroidal field and plasma current were also kept constant and there was little change in the edge electron density ne and electron temperature T e profiles. The density fluctuation amplitude was reduced approaching the transition, while a large increase of turbulence Reynolds stress and flow shear were simultaneously observed. The turbulence decorrelation rate was found to increase as the ion ∇B drift direction was moving towards the favourable configuration, but the flow shear also increased and exceeded the turbulence decorrelation rate. These measurements demonstrate an important correlation between turbulence and turbulence-driven flow and a lowering of PLH, provide insights into the underlying physics behind the hidden parameters and inform a more complete physics-based model of the L-H transition power threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-dependent probability density function analysis of H-mode transitions

Abstract The first application of time-dependent probability density function (PDF) analysis to the L-H transition in fusion plasmas is presented. PDFs are constructed using Doppler Backscattering data of perpendicular fluctuation velocity, , and turbulence from the edge region of the DIII-D tokamak. These raw time-series data are sliced into millisecond-long sliding time-windows to create PDFs. During the transition, the PDFs develop strong right tails, indicative of turbulence-suppressing localised flows in the plasma edge; such features and other subtle behaviours are explored using novel information geometry techniques. This letter examines the applicability of these techniques to predict L-H transitions and investigate predator-prey self-regulation theories between turbulence and perpendicular velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗