Search NASA⌕ Search

SEARCH · Search NASA

Results for “monochromator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A high transmission tender X-ray monochromator employing a matched pair of multilayer grating and mirror

It is now well established that multilayer coated gratings may offer high diffraction efficiencies over the tender X-ray range, from about 1 keV to 5 keV, covering the gap between single layer coated grating monochromators and crystal monochromators. Nevertheless, few beamlines in the world are using such gratings in their monochromator. The successful implementation of a multilayer grating monochromator requires producing a matched pair of a multilayer grating and a multilayer mirror, and this matching is not straightforward as it must account for different incidence angles and refraction effects on each element. Here we review the realization of the multilayer grating monochromator of the SIRIUS beamline which has been successfully in service for several years. We show how, by alternating computer simulation with our diffraction code and measurements, we could optimize the monochromator transmission on a very wide energy range. After the grating was coated, it was found that the angle of optimal efficiency versus photon energy was significantly different from what was predicted by a simple conformal model of binary layers. Layer interdiffusion and profile smoothing during the deposition process must be added to the multilayer model to reproduce the measured data. The critical adjustment of the mirror multilayer period is achieved by the lateral translation of the mirror, which was given a small transverse period gradient. The monochromator is thus providing high transmission efficiency in the 1 to 5 keV energy range, more than 30% over 2.5 keV and up to 46% at 4.6 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Towards a wavefront-preservation X-ray crystal monochromator for high-repetition-rate FELs

The wavefront preservation of coherent X-ray free-electron laser beams is pushing the requirement on the quality and performance of X-ray optics to an unprecedented level. The Strehl ratio can be used to quantify this requirement. In this paper, the criteria for thermal deformation of the X-ray optics are formulated, especially for crystal monochromators. To preserve the X-ray wavefront, the standard deviation of the height error should be sub-nm for mirrors and less than 25 pm for crystal monochromators. Cryocooled silicon crystals combined with two techniques can be used to achieve this level of performance for monochromator crystals: (1) using a focusing element to compensate the second-order component of the thermal deformation; (2) introducing a cooling pad between the cooling block and silicon crystal and optimizing the effective cooling temperature. Each of these techniques allows the thermal deformation in standard deviation of the height error to be reduced by an order of magnitude. As an example, for the LCLS-II-HE Dynamic X-ray Scattering instrument, the criteria on thermal deformation of a high-heat-load monochromator crystal can be achieved for a 100 W SASE FEL beam. Wavefront propagation simulations confirm that the reflected beam intensity profile is satisfactory on both the peak power density and focused beam size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Tunable Resolution Grating Monochromator and the Quest for Transform Limited Pulses

A variable resolution, transform limited monochromator is designed for the Free Electron Laser (FEL) source of LCLS. It provides monochromatic beam in the 250–1500 eV range, delivering the beam on the second floor of the LCLS experimental Hall. One major requirement for this monochromator is to provide, as close as possible, monochromatic transform limited pulses for time-resolved experiments. The theory and the limit of using classical diffraction scheme to monochromatize Soft X-ray beam, while preserving the pulse length, will be presented, together with the optical scheme of this versatile monochromator design.

47 OTHER INSTRUMENTATION↗

Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57 Fe or 45 Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal loading on self-seeding monochromators in x-ray free electron lasers

One approach to achieve longitudinally coherent hard X-ray free electron laser (XFEL) radiation is to introduce a single-crystal monochromator in the beam path to generate a co-propagating, time-synchronized self-seeding radiation pulse. For modern high-repetition rate XFELs, however, thermal loading on the crystal can degrade the quality of the seed pulse. To assess limitations on the maximum XFEL pulse repetition rate imposed by the seeding crystal, a comprehensive study of thermomechanical, and X-ray diffraction effects within the crystal is presented in this paper for two consecutive self-amplified spontaneous emission pulses incident on both reflective and transmissive crystal monochromators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Isotope-Resolved Electron Energy Loss Spectroscopy in a Monochromated Scanning Transmission Electron Microscope

The development and implementation of high-stability monochromators in state-of-the-art aberration-corrected scanning transmission electron microscopes has enabled materials characterization with an energy resolution as good as 3 meV. This allows the vibrational modes, which would otherwise be obscured by the energy spread of the electron beam, to be probed with very high precision in molecular materials. Since the vibrational energies depend on the weight of the atomic nuclei, vibrational spectroscopy can distinguish isotopes whose only difference lies in their neutron content. This opens up isotopic analysis and mapping in transmission electron microscopy as two important new research areas. In this paper, we review the monochromated electron energy loss spectroscopy (EELS) instrumentation, discuss optimal methods for probing beam-sensitive materials without destroying them, and review key nanoscale isotope-resolved results.

47 OTHER INSTRUMENTATION↗

Tunable side-bounce x-ray monochromator

Monochromators selectively transmit a narrow band of wavelengths of radiation from a broader band of wavelengths for use in a variety of applications and industries. Disclosed is a method and system for fixed-exit angle tunable monochromator. The system includes a first diffraction element configured to reflect an input beam incident on a surface of the first diffraction element. The input beam has an input beam vector and the first diffraction element is rotatable about the input beam vector. The system further includes a second diffraction element configured to reflect the beam as an output beam having a fixed beam exit angle. The beam is incident on a surface of the second diffraction element and the reflected beam has a reflected beam vector. The second diffraction element is rotatable about both the input beam vector and the reflected beam vector.

Hong, Hawoong↗

A simple method for mitigating error in the fixed-offset of a double-crystal monochromator

In order to maintain a constant monochromatic synchrotron X-ray beam height for all energies, the separation between the crystals of a double-crystal monochromator is typically adjusted, via translation of the second crystal, while X-ray energy is varied, via rotation of the crystal pair. The ability to accurately translate the second crystal requires precise knowledge of the separation between the two crystals and, when present, crystal miscuts. Here, a simple method for calibrating the crystal gap from measured variation in the X-ray beam height that eliminates error in the fixed beam offset is provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator↗

Twist-Angle-Dependent Excitons in Moiré MoTe 2 Visualized by Cryogenic STEM and Monochromated EELS

van der Waals twisted bilayers of transition-metal dichalcogenides exhibit diverse excitonic phenomena arising from moiré superlattices and lattice reconstruction. While interlayer strain and relaxation reshape their electronic bands, their nanoscale influence on the excitonic fine structure remains poorly understood. Here, we study the interplay between spin–orbit coupling (SOC) and the moiré lattice by probing excitons in H-type twisted (∼8-layer × 8-layer) MoTe 2 using atomic-resolution scanning transmission electron microscopy (STEM) combined with monochromated electron energy loss spectroscopy (EELS) at cryogenic temperature. Spatially resolved spectra reveal moiré-site-dependent variations in excitonic absorption, including modulation of the X B exciton across the moiré unit cell. We find that SOC in MoTe 2 increases with the twist angle within the studied range (2–4.5°), with the largest value observed at 4°. Furthermore, these findings establish the twist angle as a tunable parameter for SOC via moiré engineering and link local structural relaxation to excitonic fine structure in twisted MoTe 2 .

cryogenic STEM/EELS↗

Probing molecular vibrations by monochromated electron microscopy

Chemical bonds fundamentally determine molecular properties and are prevalently characterized by various spectroscopic means such as infrared and Raman spectroscopies. However, the spatial resolution of these conventional approaches is insufficient to reveal nanoscale features. Recently, monochromated electron energy-loss spectroscopy (EELS) in the transmission electron microscope achieved a groundbreaking energy resolution of a few millielectronvolts and enabled direct observation of molecular vibrational spectrum with unmatched spatial resolution. Vibrational EELS is widely applicable to both organic and inorganic matter in the solid state or liquid phase. In this study, we introduce recent advancements and key concepts of this method, compare with other spectroscopic techniques, and discuss future developments for potential applications in research fields centered on catalysts, polymers, and live cells.

Vibrational Spectroscopy↗

Harmonic suppression gratings for soft X-ray monochromators

We describe an approach to harmonic suppression in soft X-ray monochromators by engineering the reflection grating’s diffraction pattern to approximate a sinusoidal amplitude. At synchrotron and free-electron laser sources, X-ray beamlines powered by insertion devices produce a spectrum containing harmonic photon energies that can couple unwanted light into experiments. Beamlines in the soft X-ray energy range (100 eV to 2 keV) commonly employ energy-filtering elements to suppress these harmonics. Available approaches tend to be inefficient, significantly reducing the transmitted power. We show that with pseudo-grayscale binary halftone patterns, gratings can approximate a sinusoidal amplitude and suppress higher diffraction orders. Prototype demonstrations of lithographically fabricated gratings were conducted on a soft X-ray beamline with photon energies of 110 eV and 330 eV. Relative to a square-wave amplitude grating, the third-harmonic intensity was reduced by a factor of 9.0 with a first-order efficiency reduction of 38%.

Goldberg, Kenneth A. [Lawrence Berkeley National L↗

Monochromation of pulsed electron beams with terahertz radiation at a planar mirror

Exquisite control of electron beam energy is required for many electron spectroscopy and imaging applications. For both continuous and pulsed beams, the beam energy spread is fundamentally limited by the electron source, and is typically a sizable fraction of an electron-volt. In this paper, we present a means to reduce electron beam energy spread after emission to the level of a few 10s of meV rms using femtosecond photoemission and an interaction with laser-derived single- to few-cycle terahertz (THz) radiation. We show analytically and in particle tracking simulations that this interaction can remove energy spread stored in both the transverse and longitudinal degrees of freedom. We analytically formulate the limit of energy spread that this technique can achieve, and map the non-ideal affects arising at high frequencies. The interaction is mediated by the beam's passage through a mirror which is reflective to terahertz radiation but allows transmission of the majority of the electron beam (e.g. a wire mesh). This method then only requires beam current losses of a few tens of percent, far smaller than what is achieved in prism and slit-based electron monochromators.

Accelerator Physics (physics.acc-ph)↗