Nonlinear post-compression to sub-20 fs using a single-stage multipass cell filled with ambient air

Noble gas-filled multipass cells have proven to be very effective in compressing high-energy, hundreds-of-femtoseconds pulses down to tens of femtoseconds. Molecular gases can be an attractive alternative to noble gases since they provide additional Raman nonlinearities that can be much stronger than the electronic Kerr nonlinearity and can therefore enable more spectral broadening and shorter compressed pulses. Air at atmospheric pressure offers molecular gases in their simplest format, with both easy access and no costs for implementing a gas chamber. Here we demonstrate a single-stage, air-filled multipass cell that spectrally broadens 145- μ J, 185-fs pulses with >90% throughput, with a small fraction of the output compressed to sub-20 fs using a prism-pair compressor. The multipass cell uses standard broadband mirrors without dispersion engineering and ambient air as the nonlinear medium, making it the simplest and most cost-effective solution for generating few-cycle femtosecond pulses.

47 OTHER INSTRUMENTATION↗

Efficient nonlinear post-compression to sub-20 fs using an air-filled multipass cell

We demonstrate nonlinear post-compression of 1-kHz, 185-fs pulses at a 1038-nm center wavelength to sub-20 fs, using a single-stage multipass cell filled with ambient air. The pulse energy out of the multipass cell is >130 μJ, with a corresponding throughput over 90%. Here, the multipass cell uses standard broadband mirrors without dispersion engineering and ambient air as the nonlinear medium, making it the simplest and most cost-effective solution for generating few-cycle femtosecond pulses.

multipass cell↗

Numerical investigation of gas-filled multipass cells in the enhanced dispersion regime for clean spectral broadening and pulse compression

We show via numerical simulations that the regime of enhanced frequency chirp can be achieved in gas-filled multipass cells. Our results demonstrate that there exists a region of pulse and cell parameters for which a broad and flat spectrum with a smooth parabolic-like phase can be generated. This spectrum is compatible with clean ultrashort pulses, whose secondary structures are always below the 0.5% of its peak intensity such that the energy ratio (the energy contained within the main peak of the pulse) is above 98%. This regime makes multipass cell post-compression one of the most versatile schemes to sculpt a clean intense ultrashort optical pulse.

Segundo Staels, V. W. (ORCID:0000000200056157)↗

Novel focal point multipass cell for absorption spectroscopy on small sized atmospheric pressure plasmas

A novel focal point multipass cell (FPMPC) was developed, in which all laser beams propagate through a common focal point. It is exclusively constructed from standard optical elements. Main functional elements are two 90{sup ∘} off-axis parabolic mirrors and two retroreflectors. Up to 17 laser passes are demonstrated with a near-infrared laser beam. The number of laser passes is precisely adjustable by changing the retroreflector distance. At the focal point beams are constricted to fit through an aperture of 0.8 mm. This is shown for 11 beam passes. Moreover, the fast temporal response of the cell permits investigation of transient processes with frequencies up to 10 MHz. In order to demonstrate the applicability of the FPMPC for atmospheric pressure plasma jets, laser absorption spectroscopy on the lowest excited argon state (1s{sub 5}) was performed on a 1 MHz argon atmospheric pressure plasma jet. From the obtained optical depth profiles, the signal-to-noise ratio was deduced. It is shown that an elevation of the laser pass number results in an proportional increase of the signal-to-noise ratio making the FPMPC an appropriate tool for absorption spectroscopy on plasmas of small dimensions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical rotation in excess of 100 rad generated by Rb vapor in a multipass cell

Paramagnetic Faraday rotation is a powerful technique for atom sensing widely used in quantum nondemolition measurements, fundamental symmetry tests, and other precision measurements. We demonstrate the use of a multipass optical cell for Faraday rotation spectroscopy and observe polarization rotation in excess of 100 rad from spin-polarized Rb vapor. Unlike optical cavities, multipass cells have a deterministic number of light passes and can be used to measure large optical rotations. We also observe a tenfold suppression of transverse spin relaxation when Rb atoms are placed in a coherent superposition state immune to spin-exchange collisions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Near re-entrant dense pattern optical multipass cell

A multiple pass optical cell and method comprising providing a pair of opposed mirrors, one cylindrical and one spherical, introducing light into the cell via an entrance mechanism, and extracting light from the cell via an exit mechanism, wherein the entrance mechanism and exit mechanism are coextensive or non-coextensive.

Silver, Joel A.↗

Dense Pattern Optical Multipass Cell

A multiple pass optical cell and method comprising providing a pair of opposed cylindrical mirrors having curved axes with substantially equal focal lengths, positioning an entrance hole for introducing light into the cell and an exit hole for extracting light from the cell, wherein the entrance hole and exit hole are coextensive or non-coextensive, introducing light into the cell through the entrance hole, and extracting light from the cell through the exit hole.

Silver, Joel A.↗

Near re-entrant dense pattern optical multipass cell

A multiple pass optical cell and method comprising providing a pair of opposed mirrors, one cylindrical and one spherical, introducing light into the cell via an entrance mechanism, and extracting light from the cell via an exit mechanism, wherein the entrance mechanism and exit mechanism are coextensive or non-coextensive.

Silver, Joel A.↗

Dense pattern optical multipass cell

A multiple pass optical cell and method comprising providing a pair of opposed cylindrical mirrors having curved axes with substantially equal focal lengths, positioning an entrance hole for introducing light into the cell and an exit hole for extracting light from the cell, wherein the entrance hole and exit hole are coextensive or non-coextensive, introducing light into the cell through the entrance hole, and extracting light from the cell through the exit hole.

47 OTHER INSTRUMENTATION↗

Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass gas cell

A ppb-level formaldehyde (H 2 CO) sensor was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) room temperature interband cascade laser (ICL) emitting at 3.59 μm and a miniature dense pattern multipass gas cell with >50 m optical path length. Performance of the sensor was investigated with two measurement schemes: direct absorption (DAS) and wavelength modulation spectroscopy (WMS). With an integration time of less than 1.5 second, a detection limit of ~3 ppbv for H 2 CO measurement with precision of 1.25 ppbv for DAS and 0.58 ppbv for WMS, respectively, was achieved without zero air based background subtraction. An Allan-Werle variance analysis indicated that the precisions can be further improved to 0.26 ppbv @ 300s for DAS and 69 pptv @ 90 s for WMS, respectively. Finally, a side-by-side comparison between two measurement schemes is also discussed in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self- and Air-Broadened Line Shapes in the 2v3 P and R Branches of 12CH4

In this paper we report line shape parameters of 12CH4 for several hundred 2V(sub 3) transitions in the spectral regions 5891-5996 cm( exp -1) (P branch) and 6015-6115 cm(exp -1) (R branch). Air- and self-broadening coefficients were measured as a function of temperature; line mixing via off-diagonal relaxation matrix element coefficients was also obtained for 47 transition pairs. In total, nearly 1517 positions and intensities were retrieved, but many transitions were too weak for the line shape study. For this analysis, we used 25 high-resolution (0.0056 and 0.0067 cm(ex[ -1) and high signal-to-noise (S/N) spectra of high-purity 12CH4 and the same high-purity 12CH4 broadened by dry air recorded at different sample temperatures between 130 K and 295 K with the Bruker IFS 125HR Fourier transform spectrometer at JPL. Three different absorption cells were used (1) a White cell set to a path length of 13.09 m for room temperature data, (2) a single-pass 0.2038 m long coolable cell (for self-broadening) and (3) a multipass cell with 20.941 m total path coolable Herriott cell (for air-broadening). In total there were 13 spectra with pure 12CH4 (0.27-599 Torr) and 12 air-broadened spectra with total sample pressures of 80-805 Torr and volume mixing ratios (VMR) of methane between 0.18 and 1.0. An interactive multispectrum nonlinear least-squares technique was employed to fit the individual P10-P1 and R0-R10 manifolds in all the spectra simultaneously. Results obtained from the present analysis are compared to other recent measurements.

Devi, V. Malathy↗

Miniaturized Gas Correlation Radiometer for the Detection of Trace Gases in the Martian Atmosphere

We present a miniaturized and simplified version of a gas correlation radiometer (GCR) capable of simultaneously mapping multiple trace gases and identifying active regions on the Mars surface. Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Reduction of the size and mass of the GCR was achieved by implementing compact, light-weight 1 mm inner diameter hollow-core optical fibers (hollow waveguides) as the gas correlation cells. In a comparison with an Earth orbiting CO2 GCR instrument, exchanging the 10 m multipass cells with hollow waveguide gas correlation cells of equivalent path length reduces the mass from approximately 150 kg to approximately 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately 1 meter in diameter by 0.05 m in height (mass and volume reductions of greater than 99%). A unique feature of this instrument is its stackable module design, with a single module for each trace gas. Each of the modules is self-contained, and fundamentally identical; differing by the bandpass filter wavelength range and gas mixtures inside the hollow-waveguide absorption cells. The current configuration contains four stacked modules for simultaneous measurements of methane (CH4), formaldehyde (H2CO), water vapor (H2O), and deuterated water vapor (HDO) but could easily be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance. Preliminary results indicate that a 1 ppb detection limit is possible for both formaldehyde and methane with one second of averaging. Using non-optimized components, we have demonstrated an instrument sensitivity equivalent to approximately 30 ppb for formaldehyde, and approximately 500 ppb for methane. We expect custom bandpass filters and 6 m long waveguides to significantly improve these promising results. Ongoing testing is being conducted on water vapor and deuterated water vapor.

Melroy, Hilary R.↗

Miniaturized Hollow-Waveguide Gas Correlation Radiometer (GCR) for Trace Gas Detection in the Martian Atmosphere

Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Here, we present a miniaturized and simplified version of this instrument capable of mapping multiple trace gases and identifying active regions on the Mars surface. Reduction of the size and mass of the GCR instrument has been achieved by implementing a lightweight, 1 mm inner diameter hollow-core optical fiber (hollow waveguide) for the gas correlation cell. Based on a comparison with an Earth orbiting CO2 gas correlation instrument, replacement of the 10 meter mUltipass cell with hollow waveguide of equivalent pathlength reduces the cell mass from approx 150 kg to approx 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately I meter in diameter by 0.05 m in height (mass and volume reductions of >99%). This modular instrument technique can be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance.

Wilson, Emily L.↗

Performance characteristics of narrow linewidth fiber laser pumped mid-IR difference frequency mixing light source for methane detection

A high-power, narrow-linewidth Yb fiber laser with a fiber Bragg grating (FBG) pumped difference frequency generation (DFG) in a periodically poled lithium niobate (PPLN) crystal was investigated in detail. A mid-IR power of approximately 2.3 microW at 3.3 micrometers with a slope efficiency of 0.85 mW/W2 was achieved. A Doppler-broadened absorption spectrum of CH4 at 3038.497 cm-1 (3.2911 micrometers) was obtained with a 0.1-m long-gas cell at a pressure of 133 Pa. The linewidth of the DFG source was evaluated to be less than 96 MHz from the observed spectral linewidth. Real-time monitoring of CH4 (approximately 1.78 ppm) in ambient air in a multipass cell which has an optical path length of 10 m was also demonstrated.

Non-NASA Center↗

Nuclear spin dependence of the reaction of H{sub 3}{sup +} with H{sub 2}. II. Experimental measurements

The nuclear spin dependence of the chemical reaction H{sub 3}{sup +}+ H{sub 2}{yields} H{sub 2} +H{sub 3}{sup +} has been studied in a hollow cathode plasma cell. Multipass infrared direct absorption spectroscopy has been employed to monitor the populations of several low-energy rotational levels of ortho- and para-H{sub 3}{sup +} (o-H{sub 3}{sup +} and p-H{sub 3}{sup +}) in hydrogenic plasmas of varying para-H{sub 2} (p-H{sub 2}) enrichment. The ratio of the rates of the proton hop (k{sup H}) and hydrogen exchange (k{sup E}) reactions {alpha}{identical_to}k{sup H}/k{sup E} is inferred from the observed p-H{sub 3}{sup +} fraction as a function of p-H{sub 2} fraction using steady-state chemical models. Measurements have been performed both in uncooled (T{sub kin}{approx} 350 K) and in liquid-nitrogen-cooled (T{sub kin}{approx} 135 K) plasmas, marking the first time this reaction has been studied at low temperature. The value of {alpha} has been found to decrease from 1.6 {+-} 0.1 at 350 K to 0.5 {+-} 0.1 at 135 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of several high-resolution infrared bands of perdeutero-spiropentane, C5D8

Perdeutero-spiropentane (C5D8) has been synthesized and infrared spectra were taken from 400 to 4000 cm-1 at low sample pressures in a 22 meter multipass cell. The spectral resolution (0.0015 cm-1) reveals thousands of individual rovibrational transitions for several fundamental bands occurring in the spectral region of 500 to 1100 cm-1. C5D8 ground state constants reported in a previous study of a ?15 parallel band at 1054 cm-1 [1] were improved significantly in the present work by adding combination-differences derived from ?16 parallel and ?24 perpendicular band analyses. The larger data set at higher J values also allowed determination of the ground state K? = 2 splitting constant (?2? = 0.76(2) ×10-9 cm-1). For ?16, the band origin is 847.16933(5) cm-1 and changes in upper state rotational constants are ?A = –0.0013411(5) and ?B = –0.0002021(1) (in units of cm-1). Overlapping, and in Fermi resonance with ?16, is a second parallel band which, from Gaussian calculations at the anharmonic level, is assigned as the b2 combination ?8+?12, with band origin of 840.5434(1) and ?A = –0.0003500(7) and ?B = –0.0003502(1) cm-1. For ?24 analogous values are 556.41453(2) and ?A = –0.00032295(9) and ?B = –0.00016782(4) cm-1. The analyses also yields accurate values for the changes in both quartic and sextic centrifugal distortion constants and, for ?24, values for the l-doubling constants q+ and q-. Theoretical calculations of the rovibrational parameters aided in the analysis and the numerical values are in good agreement with experimental results.

Nibler, Joseph W.↗

Sensitive detection of formaldehyde using an interband cascade laser near 3.6 μm

Here, we report the development of a formaldehyde (H 2 CO) trace gas sensor using a continuous wave (CW), thermoelectrically-cooled (TEC), distributed-feedback interband cascade laser (DFB-ICL) at 3.6 μm. Wavelength modulation spectroscopy was used to detect the second harmonic spectra of a strong H 2 CO absorption feature centered at 2778.5 cm -1 (3599 nm) in its ν 1 fundamental vibrational band. A compact and novel multipass cell (7.6-cm physical length and 32-ml sampling volume) was implemented to achieve an effective optical path length of 3.75 m. A minimum detection limit of 6 parts per billion (ppb) at an optimum gas pressure of 200 Torr was achieved with a 1-s data acquisition time. An Allan-Werle deviation analysis was performed to investigate the long-term stability of the sensor system and a 1.5 ppb minimum detectable concentration could be achieved by averaging up to 140 s. Absorption interference eeffects from atmospheric H 2 O (2%) and CH 4 (5 ppm) were also analyzed in this work and proved to be insignificant for the current sensor configuration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗