Search NASA⌕ Search

SEARCH · Search NASA

Results for “multipass cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nonlinear post-compression to sub-20 fs using a single-stage multipass cell filled with ambient air

Noble gas-filled multipass cells have proven to be very effective in compressing high-energy, hundreds-of-femtoseconds pulses down to tens of femtoseconds. Molecular gases can be an attractive alternative to noble gases since they provide additional Raman nonlinearities that can be much stronger than the electronic Kerr nonlinearity and can therefore enable more spectral broadening and shorter compressed pulses. Air at atmospheric pressure offers molecular gases in their simplest format, with both easy access and no costs for implementing a gas chamber. Here we demonstrate a single-stage, air-filled multipass cell that spectrally broadens 145- μ J, 185-fs pulses with >90% throughput, with a small fraction of the output compressed to sub-20 fs using a prism-pair compressor. The multipass cell uses standard broadband mirrors without dispersion engineering and ambient air as the nonlinear medium, making it the simplest and most cost-effective solution for generating few-cycle femtosecond pulses.

47 OTHER INSTRUMENTATION↗

Efficient nonlinear post-compression to sub-20 fs using an air-filled multipass cell

We demonstrate nonlinear post-compression of 1-kHz, 185-fs pulses at a 1038-nm center wavelength to sub-20 fs, using a single-stage multipass cell filled with ambient air. The pulse energy out of the multipass cell is >130 μJ, with a corresponding throughput over 90%. Here, the multipass cell uses standard broadband mirrors without dispersion engineering and ambient air as the nonlinear medium, making it the simplest and most cost-effective solution for generating few-cycle femtosecond pulses.

multipass cell↗

Numerical investigation of gas-filled multipass cells in the enhanced dispersion regime for clean spectral broadening and pulse compression

We show via numerical simulations that the regime of enhanced frequency chirp can be achieved in gas-filled multipass cells. Our results demonstrate that there exists a region of pulse and cell parameters for which a broad and flat spectrum with a smooth parabolic-like phase can be generated. This spectrum is compatible with clean ultrashort pulses, whose secondary structures are always below the 0.5% of its peak intensity such that the energy ratio (the energy contained within the main peak of the pulse) is above 98%. This regime makes multipass cell post-compression one of the most versatile schemes to sculpt a clean intense ultrashort optical pulse.

Segundo Staels, V. W. (ORCID:0000000200056157)↗

Novel focal point multipass cell for absorption spectroscopy on small sized atmospheric pressure plasmas

A novel focal point multipass cell (FPMPC) was developed, in which all laser beams propagate through a common focal point. It is exclusively constructed from standard optical elements. Main functional elements are two 90{sup ∘} off-axis parabolic mirrors and two retroreflectors. Up to 17 laser passes are demonstrated with a near-infrared laser beam. The number of laser passes is precisely adjustable by changing the retroreflector distance. At the focal point beams are constricted to fit through an aperture of 0.8 mm. This is shown for 11 beam passes. Moreover, the fast temporal response of the cell permits investigation of transient processes with frequencies up to 10 MHz. In order to demonstrate the applicability of the FPMPC for atmospheric pressure plasma jets, laser absorption spectroscopy on the lowest excited argon state (1s{sub 5}) was performed on a 1 MHz argon atmospheric pressure plasma jet. From the obtained optical depth profiles, the signal-to-noise ratio was deduced. It is shown that an elevation of the laser pass number results in an proportional increase of the signal-to-noise ratio making the FPMPC an appropriate tool for absorption spectroscopy on plasmas of small dimensions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical rotation in excess of 100 rad generated by Rb vapor in a multipass cell

Paramagnetic Faraday rotation is a powerful technique for atom sensing widely used in quantum nondemolition measurements, fundamental symmetry tests, and other precision measurements. We demonstrate the use of a multipass optical cell for Faraday rotation spectroscopy and observe polarization rotation in excess of 100 rad from spin-polarized Rb vapor. Unlike optical cavities, multipass cells have a deterministic number of light passes and can be used to measure large optical rotations. We also observe a tenfold suppression of transverse spin relaxation when Rb atoms are placed in a coherent superposition state immune to spin-exchange collisions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Near re-entrant dense pattern optical multipass cell

A multiple pass optical cell and method comprising providing a pair of opposed mirrors, one cylindrical and one spherical, introducing light into the cell via an entrance mechanism, and extracting light from the cell via an exit mechanism, wherein the entrance mechanism and exit mechanism are coextensive or non-coextensive.

Silver, Joel A.↗

Dense pattern optical multipass cell

A multiple pass optical cell and method comprising providing a pair of opposed cylindrical mirrors having curved axes with substantially equal focal lengths, positioning an entrance hole for introducing light into the cell and an exit hole for extracting light from the cell, wherein the entrance hole and exit hole are coextensive or non-coextensive, introducing light into the cell through the entrance hole, and extracting light from the cell through the exit hole.

47 OTHER INSTRUMENTATION↗

Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass gas cell

A ppb-level formaldehyde (H 2 CO) sensor was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) room temperature interband cascade laser (ICL) emitting at 3.59 μm and a miniature dense pattern multipass gas cell with >50 m optical path length. Performance of the sensor was investigated with two measurement schemes: direct absorption (DAS) and wavelength modulation spectroscopy (WMS). With an integration time of less than 1.5 second, a detection limit of ~3 ppbv for H 2 CO measurement with precision of 1.25 ppbv for DAS and 0.58 ppbv for WMS, respectively, was achieved without zero air based background subtraction. An Allan-Werle variance analysis indicated that the precisions can be further improved to 0.26 ppbv @ 300s for DAS and 69 pptv @ 90 s for WMS, respectively. Finally, a side-by-side comparison between two measurement schemes is also discussed in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear spin dependence of the reaction of H{sub 3}{sup +} with H{sub 2}. II. Experimental measurements

The nuclear spin dependence of the chemical reaction H{sub 3}{sup +}+ H{sub 2}{yields} H{sub 2} +H{sub 3}{sup +} has been studied in a hollow cathode plasma cell. Multipass infrared direct absorption spectroscopy has been employed to monitor the populations of several low-energy rotational levels of ortho- and para-H{sub 3}{sup +} (o-H{sub 3}{sup +} and p-H{sub 3}{sup +}) in hydrogenic plasmas of varying para-H{sub 2} (p-H{sub 2}) enrichment. The ratio of the rates of the proton hop (k{sup H}) and hydrogen exchange (k{sup E}) reactions {alpha}{identical_to}k{sup H}/k{sup E} is inferred from the observed p-H{sub 3}{sup +} fraction as a function of p-H{sub 2} fraction using steady-state chemical models. Measurements have been performed both in uncooled (T{sub kin}{approx} 350 K) and in liquid-nitrogen-cooled (T{sub kin}{approx} 135 K) plasmas, marking the first time this reaction has been studied at low temperature. The value of {alpha} has been found to decrease from 1.6 {+-} 0.1 at 350 K to 0.5 {+-} 0.1 at 135 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of several high-resolution infrared bands of perdeutero-spiropentane, C5D8

Perdeutero-spiropentane (C5D8) has been synthesized and infrared spectra were taken from 400 to 4000 cm-1 at low sample pressures in a 22 meter multipass cell. The spectral resolution (0.0015 cm-1) reveals thousands of individual rovibrational transitions for several fundamental bands occurring in the spectral region of 500 to 1100 cm-1. C5D8 ground state constants reported in a previous study of a ?15 parallel band at 1054 cm-1 [1] were improved significantly in the present work by adding combination-differences derived from ?16 parallel and ?24 perpendicular band analyses. The larger data set at higher J values also allowed determination of the ground state K? = 2 splitting constant (?2? = 0.76(2) ×10-9 cm-1). For ?16, the band origin is 847.16933(5) cm-1 and changes in upper state rotational constants are ?A = –0.0013411(5) and ?B = –0.0002021(1) (in units of cm-1). Overlapping, and in Fermi resonance with ?16, is a second parallel band which, from Gaussian calculations at the anharmonic level, is assigned as the b2 combination ?8+?12, with band origin of 840.5434(1) and ?A = –0.0003500(7) and ?B = –0.0003502(1) cm-1. For ?24 analogous values are 556.41453(2) and ?A = –0.00032295(9) and ?B = –0.00016782(4) cm-1. The analyses also yields accurate values for the changes in both quartic and sextic centrifugal distortion constants and, for ?24, values for the l-doubling constants q+ and q-. Theoretical calculations of the rovibrational parameters aided in the analysis and the numerical values are in good agreement with experimental results.

Nibler, Joseph W.↗

Sensitive detection of formaldehyde using an interband cascade laser near 3.6 μm

Here, we report the development of a formaldehyde (H 2 CO) trace gas sensor using a continuous wave (CW), thermoelectrically-cooled (TEC), distributed-feedback interband cascade laser (DFB-ICL) at 3.6 μm. Wavelength modulation spectroscopy was used to detect the second harmonic spectra of a strong H 2 CO absorption feature centered at 2778.5 cm -1 (3599 nm) in its ν 1 fundamental vibrational band. A compact and novel multipass cell (7.6-cm physical length and 32-ml sampling volume) was implemented to achieve an effective optical path length of 3.75 m. A minimum detection limit of 6 parts per billion (ppb) at an optimum gas pressure of 200 Torr was achieved with a 1-s data acquisition time. An Allan-Werle deviation analysis was performed to investigate the long-term stability of the sensor system and a 1.5 ppb minimum detectable concentration could be achieved by averaging up to 140 s. Absorption interference eeffects from atmospheric H 2 O (2%) and CH 4 (5 ppm) were also analyzed in this work and proved to be insignificant for the current sensor configuration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CH{sub 3} + O{sub 2} {r_arrow} H{sub 2} CO + OH revisited.

New reflected shock tube kinetics experiments have been performed on the reaction CH{sub 3} + O{sub 2} -> H{sub 2}CO + OH over the temperature range 1244-1502 K. This study was carried out using a White cell multipass (path length = 7 m) optical system observing OH-radical absorption at 308 nm. Within experimental error, the new results are in excellent agreement with an earlier study from this laboratory and have therefore been combined with the earlier data, yielding an updated Arrhenius description for the rate constant, k = (1.06 {+-} 0.32) x 10{sup -12} exp(-6801 {+-} 439K/T) cm{sup 3} molecule{sup -1} s{sup -1}. This result is compared to earlier determinations, evaluations, and theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Short-lived species detection of nitrous acid by external-cavity quantum cascade laser based quartz-enhanced photoacoustic absorption spectroscopy

Spectroscopic detection of short-lived gaseous nitrous acid (HONO) at 1254.85 cm{sup −1} was realized by off-beam coupled quartz-enhanced photoacoustic spectroscopy (QEPAS) in conjunction with an external cavity quantum cascade lasers (EC-QCL). High sensitivity monitoring of HONO was performed within a very small gas-sample volume (of ∼40 mm{sup 3}) allowing a significant reduction (of about 4 orders of magnitude) of air sampling residence time which is highly desired for accurate quantification of chemically reactive short-lived species. Calibration of the developed QEPAS-based HONO sensor was carried out by means of lab-generated HONO samples whose concentrations were determined by direct absorption spectroscopy involving a ∼109.5 m multipass cell and a distributed feedback QCL. A minimum detection limit (MDL) of 66 ppbv (1 σ) HONO was achieved at 70 mbar using a laser output power of 50 mW and 1 s integration time, which corresponded to a normalized noise equivalent absorption coefficient of 3.6 × 10{sup −8 }cm{sup −1} W/Hz{sup 1/2}. This MDL was down to 7 ppbv at the optimal integration time of 150 s. The corresponding 1σ minimum detected absorption coefficient is ∼1.1 × 10{sup −7 }cm{sup −1} (MDL ∼ 3 ppbv) in 1 s and ∼1.1 × 10{sup −8 }cm{sup −1} (MDL ∼ 330 pptv) in 150 s, respectively, with 1 W laser power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the concentration ratio for {sup 13}N and {sup 12}N isotopes at atmospheric pressure by carbon dioxide absorption of diode laser radiation at {approx}2 {mu}m

The ratio of {sup 12}NO{sub 2} and {sup 13}CO{sub 2} concentrations in the human exhaled air is measured by the method of diode laser spectroscopy using a three-channel optical scheme and multipass cell. Unlike the previous measurements in the spectral range of {approx}4.3 {mu}m with a resolved rotational structure at low pressure of selected samples, the present measurements are performed in the range of {approx}2 {mu}m, in which weaker absorption bands of CO{sub 2} reside. In this case, it is possible to employ lasers and photodetectors operating at room temperature. The thorough simulation of the spectrum with collisional broadening of lines and employment of regression analysis allow one to take measurements at atmospheric pressure with the accuracy of {approx}0.04%, which satisfies the requirements to medical diagnostics of ulcers. (laser spectroscopy)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanosecond cryogenic Yb:YAG disk laser

A cryogenic Yb:YAG disk laser is modernised to increase its average and peak power. The master oscillator unit of the laser is considerably modified so that the pulse duration decreases to several nanoseconds with the same pulse energy. A cryogenic disk laser head with a flow-through cooling system is developed. Based on two such laser heads, a new main amplifier is assembled according to an active multipass cell scheme. The total small-signal gain of cryogenic cascades is ∼10{sup 8}. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum cascade laser-based analyzer for hydrogen sulfide detection at sub-parts-per-million levels

Due to its high toxicity, monitoring of hydrogen sulfide (H 2 S) concentration is essential in many industrial sites (such as natural gas extraction sites, petroleum refineries, geothermal power plants, or waste water treatment facilities), which require sub-parts-per-million sensitivities. We report on a quantum cascade laserbased spectroscopic system for detection of H 2 S in the midinfrared at ~7.2 μm. We present a sensor design utilizing Herriott multipass cell and a wavelength modulation spectroscopy to achieve a detection limit of 140 parts per billion for 1-s integration time.

47 OTHER INSTRUMENTATION↗

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗