Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol

Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10 10 Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of 241 Am.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lithium indium diselenide — An advanced material for neutron detection

Here, this paper describes the synthesis, crystal growth, detector fabrication, radiation hardening studies, MCNP modeling, and characterization of lithium indium diselenide or LiInSe 2 . This newly-developed room temperature thermal neutron detector has semiconducting and scintillating properties and it is suitable for neutron detection application. LiInSe 2 was synthesized starting from elemental Li, In, Se in two steps due to high reactivity of Li. A single crystal of LiInSe 2 was grown using the Vertical Bridgman method. The room temperature band gap was found to be 2.8 eV using optical absorption measurements. Bulk resistivity was measured at ∼5 × 10 11 Ωcm. Photoconductivity measurements of LiInSe 2 wafers identified a peak in the photocurrent around 445 nm. Nuclear radiation detectors were fabricated from single crystal wafer and the responses to alpha particles at various biases were measured. The mobility-lifetime product was estimated. Gamma irradiation studies were performed with calculated absorbed doses ranging from 0.2126 to 21,262 Gy. The characterization of the two wafers for their scintillator performance was conducted after each irradiation. The gamma irradiation produced a reduction of the light yield that translated to a lower channel number for the centroid of alpha detection spectra. It also showed a considerable reduction of the decay time after the first irradiation. These are the first studies on gamma radiation hardening with this material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Selenium Doping in Zinc Telluride from First Principles

We report point defects and compensation in zinc telluride have been subjects of study for several decades due to the compound’s scientific/technological applications. Despite this, there remains some disagreement in the literature as to the fine details of its defect chemistry. Recently, it has also come under renewed interest due to the emerging Cd( 1–x )Zn x Te( 1–y )Se y material family, used in nuclear radiation detector applications. In this article, we use state-of-the-art computational tools to re-examine the native defect chemistry of ZnTe and explore how it changes upon addition of selenium using density functional theory with screened hybrid exchange–correlation functionals, thermochemical models of the equilibration environment, and statistical mechanics models of the point defect ensemble.

II-VI semiconductors↗

Growth of Cd 0.9 Zn 0.1 Te 1-y Se y Single Crystals for Room Temperature Gamma-Ray Detection

Quaternary Cd 0.9 Zn 0.1 Te 1-y Sey (CZTS) single crystals, a novel room-temperature nuclear radiation detector semiconductor material, have been grown using a modified vertical Bridgman method (VBM) and a travelling heater method (THM). The percentage concentration of selenium in the VBM-grown crystal was 3% and that in the THM-grown crystal was 2%. While the THM Frisch collar detector (4.4 × 4.4 × 10.7 mm 3 ) produced a highly resolved pulse height spectra (PHS) with a resolution of ~1.06% for 662-keV gamma rays without any correction, the VBM-grown detector (10 × 10 × 2 mm 3 ) offered a high energy resolution of ~2% after application of a digital biparametric correction. The high-resolution performance of these detectors has been attributed to the addition of Se in the Cd 0.9 Zn 0.1 Te (CZT) matrix. Ab-initio calculations based on density functional theory (DFT) also confirmed that the addition of Se in the CZT matrix helps to reduce the formation of TeCd and the TeZn anti-sites. The VBM-grown crystals were characterized using powder x-ray diffraction (XRD) and energy dispersive x-ray spectroscopy (EDS). While XRD results revealed sharp diffraction peaks confirming the crystalline nature of the grown crystal, the EDS results confirmed the targeted stoichiometry of the elemental composition. The bulk resistivity of the grown crystal was calculated to be ~3 × 10 10 Ω-cm from current-voltage characteristics recorded at room temperature in a planar configuration, ensuring that the grown CZTS crystals have low dark current as required for detector-grade crystals.

42 ENGINEERING↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation-Induced Dark Counts for Silicon Single-Photon Detectors in Space

Single-photon detectors operating on satellites for use in a quantum communications network can incur large dark-count-rate increases from the natural radiation environment of space. Displacement damage to the material lattice of a detector from the ionizing radiation can result in a permanent dark-count increase in the detector. In this work, we analyze the radiation-induced dark-count rate of a silicon single-photon avalanche diode onboard a satellite at different orbiting altitudes, as well as, the additional radiation from a nuclear-disturbed environment caused by a high-altitude nuclear explosion. For detectors on low Earth orbit satellites, protons are the biggest source of radiation damage and are best mitigated by choosing an orbit that minimizes exposure when passing through the South Atlantic Anomaly and Polar Cusps. Detectors on medium Earth orbit and geostationary orbit satellites, if shielded by more than 10 mm of aluminum, provide the best platform in terms of the least amount of radiation damage to the detectors. In the event of a high-altitude nuclear explosion, the artificial radiation belts produced by the explosion will cause too much damage to silicon single-photon detectors on low Earth orbit satellites and render them unfit for quantum communications in less than a day. Higher orbit satellites will only suffer minor dark-count-rate increases from the artificial radiation belts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for triaxial shape coexistence in 74 Ge

The deformation properties of the low-lying states in 74 Ge have been investigated using multistep Coulomb excitation. The measurements were carried out with the advanced 𝛾-ray tracking array, GRETINA, and the CHICO2 particle detector. A comprehensive set of 𝐸⁢2 transition and diagonal matrix elements was deduced following an analysis with the semiclassical coupled-channels code GOSIA. The data were compared with results of calculations carried out within the framework of the generalized triaxial rotor model as well as with the configuration interaction shell model and the symmetric rotor model. Results from calculations with covariant density functional theory were used to construct a five-dimensional collective Hamiltonian for further comparisons with the data. Collectively, the calculations provide an accurate reproduction of the experimental matrix elements and further support an understanding in terms of the coexistence of two axially asymmetric shapes. In conclusion, this leads to an overall interpretation of the underlying structure of 74 Ge requiring triaxiality, as is also the case in the neighboring even-mass Ge isotopes.

59 ≤ A ≤ 89↗

Dual modality endocavity biopsy imaging system and method

A dual modality endocavity imaging and treatment system for detection of cancer and targeted biopsy and treatment procedures, comprising: a housing; a nuclear detector system housed within the housing and configured for detecting nuclear radiation imaging data; an ultrasound detector system housed within the housing for detecting ultrasound imaging data; a needle associated with the housing and adjustably positionable relative thereto; and a data processing module configured to receive the nuclear radiation imaging data and the ultrasound imaging data and to generate and output an image showing the relative position of the needle and an endocavity object of interest. The needle may include a distinct radiation signature to facilitate imaging thereof.

Lall, Terrence↗

Constraints on the Decay of 180⁢𝑚 Ta

180m Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known β and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the Majorana Demonstrator, an experimental search for the neutrinoless double-beta decay of 76 Ge using an array of high-purity germanium detectors, to search for the decay of 180m Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background Majorana Demonstrator detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the 180m Ta half-life on the different decay channels. With new limits up to 1.5 × 10 19 years, we improved existing limits by one to two orders of magnitude. Furthermore, this result is the most sensitive search for a single β and electron capture decay ever achieved.

150 ≤ A ≤ 189↗

First Observation of Cyclotron Radiation from MeV-Scale e ± following Nuclear β Decay

We present an apparatus for detection of cyclotron radiation yielding a frequency-based β ± kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear β decays. The cyclotron frequency of the radiating β particles in a magnetic field is used to determine the β energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of β – ’s from 6 He and β + ’s from 19 Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for β spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic β’s in a waveguide. Furthermore, this work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision β-decay measurements.

43 PARTICLE ACCELERATORS↗

First study of the $^{139}\text{Ba}(n,y)^{140}\text{Ba}$ reaction to constrain the conditions for the astrophysical $\mathcal{i}$ process

New astronomical observations point to a nucleosynthesis picture that goes beyond what was accepted until recently. The intermediate “i” process was proposed as a plausible scenario to explain some of the unusual abundance patterns observed in metal-poor stars. The most important nuclear physics properties entering i-process calculations are the neutron-capture cross sections and they are almost exclusively not known experimentally. In this report we provide the first experimental constraints on the 139 Ba(n,γ) 140 Ba reaction rate, which is the dominant source of uncertainty for the production of lanthanum, a key indicator of i-process conditions. This is an important step towards identifying the exact astrophysical site of stars carrying the i-process signature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗