Search NASA⌕ Search

SEARCH · Search NASA

Results for “on-board storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of Materials-Based Options for On-Board Hydrogen Storage for Rail Applications

The objective of this project was to evaluate material- and chemical-based solutions for hydrogen storage in rail applications as an alternative to high-pressure hydrogen gas and liquid hydrogen. Three use cases were assessed: yard switchers, long-haul locomotives, and tenders. Four storage options were considered: metal hydrides, nanoporous sorbents, liquid organic hydrogen carriers, and ammonia, using 700 bar compressed hydrogen as a benchmark. The results suggest that metal hydrides, currently the most mature of these options, have the highest potential. Storage in tenders is the most likely use case to be successful, with long-haul locomotives the least likely due to the required storage capacities and weight and volume constraints. Overall, the results are relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of fuel cell electric locomotives. The results obtained here will contribute to the development of technical storage targets for rail applications that can guide future research. Moreover, the knowledge generated by this project will assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Porous materials for hydrogen storage

Hydrogen is a clean energy carrier and a promising candidate to realize carbon-neutral systems for a sustainable future because the combustion of hydrogen produces only water. The large-scale implementation of hydrogen, particularly in zero-emission hydrogen-powered fuel-cell automobiles, requires efficient hydrogen storage systems; however, the current on-board hydrogen storage technologies mainly rely on costly and potentially unsafe high-pressure compression strategies that reach pressures of up to 700 bar. Recently, solid-state porous materials, such as metal-organic frameworks, have emerged as sorbents that can conceivably store comparable amounts of hydrogen in a safer and more efficient manner relative to the current high-pressure storage technologies. Here this review summarizes the current progress on the development of state-of-the-art porous materials and their composites for hydrogen storage. We hope this work will inspire efforts toward creating next-generation hydrogen storage materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing Fuel Cell Electric Powertrain Architectures for Commercial Vehicles

Here, this article addresses the architecture development for a commercial vehicle fuel cell electric powertrain by establishing a clear multi-step formalized workflow that employs a unique technoeconomic solution for architecture selection. The power capability of the fuel cell, the energy capacity and chemistry of the electrical energy storage (battery), the DC-DC converter (including the input current rating and isolation resistance requirements), the traction drive solution, the on-board hydrogen storage solution, and the real-time power-split management of the fuel cell and the battery are all considered and developed in this effort. The methods were used to select architecture for Class 8 urban, regional, and line haul applications. When compared to traditional load-following power-split controllers, an energy management power-split controller can increase system energy efficiency by up to 19.5%. The energy-efficient power-split controller may increase the required battery capacity for an equivalent life by up to 2.6 times. The impact on the total cost of ownership (TCO) for a variety of financial cases demonstrates that high C-rate capable batteries have the potential to provide better TCO solutions over a six-year vehicle life than low C-rate capable batteries. To achieve TCO parity with the 600 A non-isolated DC-DC converter case, the specific choice of the fuel cell DC-DC converter to achieve a target power output based on current levels (from 500 A to 2400 A) shows that efficiency decreases and cost increases due to the higher current, requiring fuel cell prices to decrease by $50–$100/kW, $60–$110/kW, and $100–$220/kW for urban, regional, and line haul applications, respectively. Key recommendations for powertrain system architectures are provided, with specifics based on vehicle dynamics, mission and application characteristics, end customer use-case profile, critical powertrain component costs, and architecture selection cost function. This study rigorously demonstrates the interplay of the above parameters, with a focus on TCO, and provides application decision-makers with a mechanism and well-defined set of impact factors to consider as part of their architecture selection process.

25 ENERGY STORAGE↗

Methods for Estimating Hydrogen Fuel Tank Characteristics

The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.

42 ENGINEERING↗

Economic feasibility of in-motion wireless power transfer in a high-density traffic corridor

Electricity is expected to become a dominant power source in the transportation sector, but under a stationary recharging model, electric powered vehicles still suffer some disadvantages relative to conventional vehicles. Recent developments in wireless power transfer (WPT) technology can enable an alternative vehicle recharging model wherein power is supplied to vehicles while they are moving, mitigating the need for charging stops and high-capacity on-board energy storage. One of the greatest concerns associated with dynamic WPT is that the required infrastructure costs would be prohibitively high; however, the life-cycle costs and benefits of such a system have been under-researched. Here in this work, we apply a systems-level assessment to a case study of a WPT charging system located on the densely trafficked I-710 corridor in Los Angeles, California. Detailed cost estimates for electronics and implementation, high-fidelity energy consumption modeling, and survey-derived adoption projections are applied to evaluate scenarios of economic feasibility and environmental impact. Results show that a “1st-of-a-kind” system can achieve a payback in 20 years while maintaining operating cost advantages relative to petroleum fueling. System economics are shown to improve substantially with “nth-of-a-kind” capital costs. Discussion focuses on the effect of uptake trajectory on economic viability and detailed economics outcomes for light duty and heavy duty vehicles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamic Capacitive Wireless Power Transfer System for Electric Vehicles (CRADA Final Report)

Road transportation accounts for 23% of our nation's total energy consumption, 59% of our petroleum consumption and 22% of our total emissions. Electric vehicles (EVs) have much higher well-to-wheel efficiency compared to gasoline vehicles and can reduce our dependence on oil, minimize emissions, improve local air quality and provide a platform for technological innovation and economic growth. While major progress has been made in the development of electric vehicles, their penetration remains under 1 The main hurdles in their widespread adoption are high cost, limited range and long charging times, due to limitations in battery technology. An approach to overcome these hurdles is to substantially reduce the on-board energy storage and instead deliver power wirelessly to the vehicle while it is in motion dynamic wireless power transfer (WPT). For EV charging applications, researchers have traditionally focused on inductive WPT. An issue with inductive WPT systems is that for magnetic flux guidance and shielding, they require ferrite cores, making them expensive, bulky and difficult to embed in the roadway. Under an ARPA-E IDEAS grant, the CU Boulder team has recently developed an alternative approach to WPT based on capacitive coupling that is much smaller, lighter, less expensive, and easier to embed in the roadway than inductive WPT; and have demonstrated a 1.2-kW 6.78-MHz version of this capacitive WPT system on a stationary platform. Under this seed grant program, preliminary work will be carried out on a dynamic capacitive WPT system to prepare a strong proposal for the ARPA-E OPEN 2018 FOA.

33 ADVANCED PROPULSION SYSTEMS↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

HD ADOPT: Heavy-Duty Vehicle Choice Model Documentation

HD ADOPT is a logit consumer vehicle choice and stock model that analyzes the Class 8 tractor market. The model projects future technology shares, fuel consumption, and greenhouse gas (GHG) emissions under input assumptions of technology progress, energy prices, and policies. ADOPT is distinguished from other vehicle choice models through inclusion of non-linear and heterogenous consumer preferences and characterization of the full range of market options rather than use of composite vehicles. In addition, ADOPT has integrated vehicle simulation capabilities that enable performance assessment and optimization of endogenous technology evolution. Optionally, the model is able to adjust this evolution to enforce compliance with fuel economy and GHG emissions regulations. Primary results include projection of technology shares and future in-use fleet energy demand, petroleum consumption, and GHG emissions. This enables analysis and comparison of future scenarios of technology improvements, economic conditions, and national policies. Recent new features for the HD modeling also enable examination of different on-board hydrogen fuel storage technologies from the lens of consumer preferences for vehicle cost and range. This report documents current ADOPT capabilities and methodologies.

33 ADVANCED PROPULSION SYSTEMS↗

System and method for measuring sun-induced chlorophyll fluorescence

A chlorophyll fluorescence measuring system having at least one spectrometer coupled to a data logger. The data logger provides direct control of the spectrometer and includes on-board memory for storage of target and reference spectrum data obtained by the spectrometer. The data logger may be coupled to an external computer that receives and analyzes target and reference spectrum data to determine SIF using a spectral fitting algorithm. The system may include a spectrometer aiming system coupled to and controlled by the data logger. The system may also include one or more environmental sensors configured to measure environment variables. The environmental sensors may be coupled to the data logger for control and data storage. The environmental data may be communicated to the external computer for use in the spectral fitting algorithm. The data logger may be connected to a network for remote monitoring and control.

Gu, Lianhong↗

Enabling Ultra-Compact, Lightweight, Efficient, and Reliable 6.6 kW On-Board Bi-Directional Electric Vehicle Charger with Advanced Topology and Control

The research explored new topologies, control methods, mechanical integration, and thermal management methods for electric vehicle (EV) on-board chargers. The team investigated capacitor-based power conversion, leveraging the high energy densities inherent to capacitive energy storage compared to inductive methods. The proposed topologies simultaneously enabled high power density and high efficiency of the design. The proposed architecture was demonstrated in a 6.6 kW bi-directional charger prototype. The research pursued several directions to improve system performance. Innovative topologies were studied for both the main power conversion stage as well as the single-phase twice-line-frequency energy buffer. To ensure robust and efficient operation, new control methods were developed to integrate these two subsystems. To achieve high power density in the full system solution, the mechanical structure of the charger is highly optimized to maximally fill the converter box volume. In parallel with the mechanical design effort, the converter was packaged with high-performance cooling methods which removed heat from key areas of power dissipation in the converter. The thermal management system was optimized to minimize its weight and volume, ultimately motivating the design of a custom additively manufactured cold-plate. The full system achieves a peak power of 7 kW with less than 0.3% total harmonic distortion (THD) and greater than 0.994 power factor in power factor correction (PFC) operation, corresponding to a total box-volume power density of 47.9 kW/L and gravimetric power density of 24.6 W/g. The system achieves a peak efficiency of 98.9%, with 97.9% efficiency at maximum power.

33 ADVANCED PROPULSION SYSTEMS↗

Designing Dynamic Wireless Power Transfer Corridors for Heavy Duty Battery Electric Commercial Freight Vehicles

The use of wireless power transfer systems, consisting of inductive electrical coils on the vehicle and the power source may be designed for dynamic operations where the vehicle will absorb energy at highway speeds from transmitting coils in the road. This has the potential to reduce the onboard energy storage requirements for vehicles while enabling significantly longer missions. This paper presents an approach to architecting a dynamic wireless power transfer corridor for heavy duty battery electric commercial freight vehicles. By considering the interplay of roadway power capacity, roadway and vehicle coil coverage, seasonal road traffic loading, freight vehicle class and weight, vehicle mobility energy requirements, on-board battery chemistry, non-electrified roadway vehicle range requirements, grid capacity, substation locations, and variations in electricity costs, we minimize the vehicle TCO by architecting the electrified roadway and the vehicle battery simultaneously. The idea optimizes battery size and chemistry so that the depth of discharge between recharge events and expected life are balanced, thus fully utilizing the energy available throughout the course of the battery system's life. The approach is illustrated by applying it to the I-75 freight corridor, where the framework developed may be expanded and applied to a larger interstate system, expanded regional corridor, or other transportation network.

Sujan, Vivek↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated charging infrastructure planning and charging scheduling for battery electric bus systems

We report studies on the electric bus system planning problem have typically focused exclusively on either the deployment of charging infrastructure or the scheduling of charging events; few have examined the impact of charging facility deployment on charging activities. Considering the interdependence of system design and operational strategies, this study proposes a two-phase optimization framework for charging infrastructure planning and charging scheduling for battery electric bus systems. An integrated optimization model is first developed to simultaneously optimize charger deployment, on-board battery capacity, and charging schedules. A charging scheduling model is further proposed and a rolling horizon approach is utilized in the second phase to optimize the real-time charging scheduling of electric buses. Compared to existing electric bus system planning methods, the proposed integrated model can reduce the total system cost by 19.5%. In addition, compared to uncontrolled charging, the proposed rolling horizon-based charging strategy can reduce the total charging cost by 68.3%.

25 ENERGY STORAGE↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of precooling unit design options in hydrogen refueling station for heavy-duty fuel-cell electric vehicles

Precooling gaseous hydrogen fuel to a cold temperature before refueling a heavy-duty (HD) hydrogen fuel cell electric vehicle (HFCEV) is essential to avoid overheating the vehicle tank, as well as achieving a high state of charge (SOC). Because a large volume of hydrogen is dispensed during each fill, the need for a shorter fill time amplifies the need to precool each load for refueling a HFCEV. Thus, the design and operation of a precooling unit (PCU), as well as the associated capital and operating costs, plays a pivotal role in any plans for heavy-duty hydrogen refueling stations. Here, in this paper, we present a thermodynamic and technoeconomic analysis of a PCU in a gaseous hydrogen refueling station (HRS) for HD HFCEVs. By employing Argonne National Laboratory's hydrogen station cost optimization and performance evaluation (H2SCOPE) model, the refueling of 50 kg of hydrogen on-board type IV tank at ambient temperatures of 15–45 °C and varying fill rates is simulated. The required degree of precooling temperature to obtain either 100% or the maximum possible SOC is obtained from the simulation. Additionally, the simulation results demonstrate that the average flow rate of hydrogen is approximately 40% lower than the maximum flow rate during a typical fill; which motivates further evaluation of the instantaneous hydrogen mass flow rate profile and suggests the scope of improving precooling unit design. Accordingly, a hybrid strategy of precooling hydrogen has been proposed to address the cooling load by sizing the refrigeration unit for the average flow rate of hydrogen, while supplementing the above average peak hydrogen flow cooling load through thermal buffering. The combined technique enables the downsizing of the original PCU capacity by 25–40% and demonstrates a potential cost reduction of the PCU by approximately 30%, which translates to an installed cost reduction of ∼$125,000 per dispenser.

25 ENERGY STORAGE↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗