Search NASA⌕ Search

SEARCH · Search NASA

Results for “online process monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An integrated manifold learning approach for high-dimensional data feature extractions and its applications to online process monitoring of additive manufacturing

As an effective dimension reduction and feature extraction technique, manifold learning has been successfully applied to high-dimensional data analysis. With the rapid development of sensor technology, a large amount of high-dimensional data such as image streams can be easily available. Thus, a promising application of manifold learning is in the field of sensor signal analysis, particular for the applications of online process monitoring and control using high-dimensional data. The objective of this study is to develop a manifold learning-based feature extraction method for process monitoring of Additive Manufacturing (AM) using online sensor data. Due to the non-parametric nature of most existing manifold learning methods, their performance in terms of computational efficiency, as well as noise resistance has yet to be improved. To address this issue, this study proposes an integrated manifold learning approach termed multi-kernel metric learning embedded isometric feature mapping (MKML-ISOMAP) for dimension reduction and feature extraction of online high-dimensional sensor data such as images. Based on the extracted features with the utilization of supervised classification and regression methods, an online process monitoring methodology for AM is implemented to identify the actual process quality status. Finally, in the numerical simulation and real-world case studies, the proposed method demonstrates excellent performance in both prediction accuracy and computational efficiency.

36 MATERIALS SCIENCE↗

A Molten Salt Aerosol Spectroscopy Approach to Online Process Monitoring in Molten Salt Reactors

Recent research and development in molten salt reactors (MSRs) has led to many advanced reactor designs, many of which have demonstrations planned in the next decade. However, a significant challenge that must be overcome before liquid fueled MSRs become viable globally is nuclear material accountancy (NMA) and safeguards. Liquid-fueled MSRs are problematic to safeguards because the nuclear material is in the bulk phase, inventories are constantly changing, and there are potentially many outlet pathways that must be monitored, especially in designs with online chemical processing. At the Idaho National Laboratory, we have developed a process monitoring tool to circulate molten salt through a nebulizer and optical cell, where laser-induced breakdown spectroscopy (LIBS) and ultraviolet-visible (UV-VIS) are applied to track the elemental and oxidation states of the constituents in the salt aerosol. This approach has the potential to provide information on the actinides, fission products, and corrosion in the reactor or process. Preliminary testing in aqueous praseodymium chloride (PrCl3) and neodymium chloride (NdCl3) showed good sensitivity detection limits n developed calibration curves. Additional tests and analysis or ongoing in aqueous solutions while equipment is being scaled up for high temperature molten salt testing. Results for continued testing as well as a status of the molten salt design and anticipated commissioning will be presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

BETO 2021 Peer Review - Process Monitoring and Predictions of Biorefinery Performance

Online process monitoring coupled with rapid predictive tools will be essential to refineries of the future to provide real-time feedback and process control on new, renewable feeds and their accompanying processes and products. This project will provide refinery operators with tools to predict product component concentrations in minutes from online, slip stream mass spectra, allowing for rapid detection of off-specification product. We will arrive at a template for predictive tool generation through the development of a specific tool as a starting point -- co-processing of pyrolysis oils and vacuum gas oil over fluid catalytic cracking (FCC) catalysts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Online Monitoring of Radiochemical Processing Streams for the Plutonium-238 Supply Program

Online monitoring with spectrophotometry is being developed to improve the timeliness of analytical measurements for the Plutonium-238 Supply Program at Oak Ridge National Laboratory. A commercially available online monitoring software was used to calculate and view process data in real time to help identify process deviations and optimize system performance. Monitoring detailed process data will improve processing efficiency and help technicians make decisions during hot-cell operations.

Sadergaski, Luke↗

First principles optimization of plutonium electrorefining

Herein this work presents a means of controlling plutonium electrorefining at a maximum rate regardless of equipment setup through the derivation of power supply current and potential governing equations for normal and off-normal operations. The governing equations are demonstrated by electrorefining surrogate materials. A simple linear current sweeping method was used to determine the maximum electrorefining current for the surrogate system. This method can be used to develop autonomous process optimization, real-time online processing monitoring, and real-time process endpoint detection. Ultimately, this research provides the foundation to optimize the liquid metal electrorefining rate to decrease the time needed to the physical limit for the process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Scaled up Process Report – Apparatus and Model

Advanced voloxidation with NO 2 is a proposed process for used nuclear fuel head-end reprocessing scheme that converts UO 2 to higher oxides, and it also converts partitioning volatile fission products into the gas phase, thus facilitating fuel dissolution and actinide recovery. NO 2 voloxidation is being studied on small batches of UO 2 Simfuel, but the real test of process feasibility will be when it is scaled up to work with >100 g of irradiated material. This report discusses the aspects of scale-up that must be considered for NO 2 voloxidation, including development of a stirred reactor to promote agitation of the mixture during processing, online process monitoring, and automation controls. Brief details on parallel efforts are also provided in this report, including (a) demonstration of iodine release from Simfuel made by Spark Plasma Sintering, and (b) development of an order-of-magnitude scale-up to react 100 g of UO 2 Simfuel in a metal reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Illuminating Cell Biology

NASA's Ames Research Center awarded Ciencia, Inc., a Small Business Innovation Research contract to develop the Cell Fluorescence Analysis System (CFAS) to address the size, mass, and power constraints of using fluorescence spectroscopy in the International Space Station's Life Science Research Facility. The system will play an important role in studying biological specimen's long-term adaptation to microgravity. Commercial applications for the technology include diverse markets such as food safety, in situ environmental monitoring, online process analysis, genomics and DNA chips, and non-invasive diagnostics. Ciencia has already sold the system to the private sector for biosensor applications.

Source record↗

Quantifying Temperature Dependence of Pu(IV) Absorbance Spectra for Advanced Online Monitoring of Nuclear Processes

This article presents a systematic study of Pu(IV) absorbance spectral features as a function of temperature to develop an understanding of this parameter’s effect on chemometric models that can be used as online monitoring tools to support nuclear processing. The descriptive and predictive models that provide real-time feedback of these processes are usually constructed with data collected in conditions typical of a laboratory environment, which can differ drastically from a processing environment. To assess the impact of temperature on Pu(IV) absorbance spectra, 11 samples of Pu(IV) were synthesized with varying HNO 3 concentrations ranging from 0.6 to 9.5 M and heated between 15 and 45 °C. Ultraviolet (UV)–visible (vis)–near-infrared (NIR) absorption spectra collected at different HNO 3 concentrations and temperatures revealed that features associated with Pu(IV) are sensitive to temperature at all HNO 3 concentrations and that changes in features depend on HNO 3 concentration. The contributions of temperature and HNO 3 concentration to variation in Pu(IV) spectral features were evaluated using the principal component analysis of spectra that were baseline-corrected with an asymmetric least-squares method. Furthermore, predictive modeling for HNO 3 concentration with partial least-squares regression of UV–vis–NIR spectra highlighted the importance of accounting for temperature in the calibration set to optimize model performance. This methodology constitutes a new, systematic approach to account for the effect of temperature on the absorption spectra of metal ions and is useful for process monitoring applications in many industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online Monitoring of Catalytic Processes by Fiber-Enhanced Raman Spectroscopy

An innovative solution for real-time monitoring of reactions within confined spaces, optimized for Raman spectroscopy applications, is presented. This approach involves the utilization of a hollow-core waveguide configured as a compact flow cell, serving both as a conduit for Raman excitation and scattering and seamlessly integrating into the effluent stream of a cracking catalytic reactor. The analytical technique, encompassing device and optical design, ensures robustness, compactness, and cost-effectiveness for implementation into process facilities. Notably, the modularity of the approach empowers customization for diverse gas monitoring needs, as it readily adapts to the specific requirements of various sensing scenarios. As a proof of concept, the efficacy of a spectroscopic approach is shown by monitoring two catalytic processes: CO 2 methanation (CO 2 + 4H 2 → CH 4 + 2H 2 O) and ammonia cracking (2NH 3 → N 2 + 3H 2 ). Leveraging chemometric data processing techniques, spectral signatures of the individual components involved in these reactions are effectively disentangled and the results are compared to mass spectrometry data. This robust methodology underscores the versatility and reliability of this monitoring system in complex chemical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for control of polymer reactions and processing using automatic continuous online monitoring

Manual and automatic methods and devices using a ACOMP system for active control of polymerization reaction processes. An ideal desired trajectory of one or more reaction and polymer characteristics can be established to produce a desired final polymer product with specified characteristics from a polymerization reaction process. A current reaction trajectory of a polymerization reaction process can be driven to an ideal or desired reaction trajectory. In a manual embodiment an operator can use ACOMP data to adjust process variables in order to drive the current reaction trajectory toward the ideal or desired reaction trajectory. In an automated mode a control program can use ACOMP data to make adjustments to process variables to drive the polymerization reaction process toward the desired trajectory as closely as possible either empirically or by solving the governing equations for the polymerization reaction process.

Reed, Wayne Frederick↗

Liquid-Arc/Spark-Excitation Atomic-Emission Spectroscopy

Constituents of solutions identified in situ. Liquid-arc/spark-excitation atomic-emission spectroscopy (LAES) is experimental variant of atomic-emission spectroscopy in which electric arc or spark established in liquid and spectrum of light from arc or spark analyzed to identify chemical elements in liquid. Observations encourage development of LAES equipment for online monitoring of process streams in such industries as metal plating, electronics, and steel, and for online monitoring of streams affecting environment.

Schlagen, Kenneth J.↗

A Review of Online Monitoring within Used Nuclear Fuel Recycling Processes

The processing of used nuclear fuels and related materials is often complex and variable. The ability to quickly optimize conditions to the material being processed can aid in increasing efficiency and safety, but requires very quick determination of the conditions present in the feedstock, the process, and the product. Furthermore, accurate quantification of materials such as enriched uranium and plutonium aids in maintaining material accountancy and avoiding nuclear proliferation risks. Traditional analytical methods require process samples to be collected and analyzed in a laboratory, which often takes days to weeks. Online monitoring is suitable for collecting this information nearly instantaneously, enabling much faster optimization of the process or detection of material diversion. Online monitoring is also beneficial as it is typically based on robust and nondestructive analytical methods, so no material is removed as samples. This review examines online monitoring relevant to used nuclear fuel processing for the determination of both chemical and physical parameters. The chemical parameters include quantities such as concentration, isotopic composition, and speciation. These values are often well suited to spectroscopic or spectrometric measurements as they are fast, nondestructive, and easily implemented in an online manner. Physical quantities are often more varied and include temperature, pressure, tank fill levels, and others. Due to the specificity of these quantities, specialized instrumentation is often used. However, this instrumentation is often amendable to online monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

H-Canyon Dissolver Offgas Monitoring Using Raman Spectroscopy

This report describes the development and in facility demonstration of a Raman spectrometer to monitor known aluminum offgas components generated during the dissolution of Spent Nuclear Fuel at the Savannah River Site H-Canyon facility. The presence of these gases is an indicator that material is actively being dissolved. This process monitoring technique, which measures the offgas in real time, has the potential to improve the efficiency of facility operations. If the dissolution time is too short, time is wasted due to extended dissolution periods with additional probing of the dissolver pot to confirm that fragment levels are below the thresholds for continuing to the next charge or moving the dissolvent to a receiving tank. If the dissolution time is too long, time and energy are wasted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continued Evaluation of the Use of a Raman Spectrometer for H-Canyon Dissolver Monitoring

Remote monitoring of dissolver activities in H-Canyon can help operators avoid delays associated with excessive levels of fuel fragments remaining after a run. SRNL has proposed that effective monitoring can be achieved by using a Raman spectrometer to measure NO 2 concentrations in the offgas stream sampled from the facility stack. Prior work (SRNL-STI-2021-00451) measuring the offgas from one dissolution batch of High Flux Isotope Reactor (HFIR) fuel suggested a relationship between %NO 2 levels and fragment height. Herein, we report the results of monitoring and analysis of the dissolution of four batches of Material Test Reactor (MTR) fuel. A rigorous quantitative relationship between %NO 2 measurements and fragment heights could not be established, due to high uncertainties associated with both measurements. Uncertainties with gas measurements are associated with the %NO 2 levels in the offgas being close to the detection limit for the analyzer. Alternative gas measurement strategies are discussed which could improve sensitivity and reduce uncertainty. Limitations to the precision of the probe measurements are also discussed. It is also noted that the offgas is an average of the products from simultaneous dissolution of elements in multiple wells. Detection of a high fragment height level in an individual well may be hindered by low levels in other wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Operation of a Multi-Bed Catalytic Micro-Reactor for the Study of Co-Processing of Bio-Oils with VGO

An industry wide shift from fossil-based fuel to renewable fuel sources including biomass, municipal waste, and plastics will require new process monitoring methods to minimize transitional risks including off specification product formation and catalyst deactivation. This project aims to provide a machine learning based process monitoring tool composed of online, slipstream mass spectra for use in biomass refineries and co-processing in existing refineries allowing operators to monitor product qualities and adjust process conditions accordingly. In order to maximize the robustness of the tool, large volumes of data must be collected to fine tune model parameters which consists of both micro and pilot scale mass spectral data. Micro-scale data is collected with a multi-tube micro-reactor housing up to six catalysts in horizontal beds, coupled with a molecular beam mass spectrometer. A pyrolizer equipped with an auto-sampler streamlines the micro-scale data collection process. This type of pyrolizer/micro-reactor configuration does not exist on the market, and therefore had to be created for the purposes of this project. The design and commissioning of this reactor will be presented in detail. This reactor set-up is highly flexible and increases throughput of analysis. For catalyst testing, each bed can be individually selected simply by turning valves. For catalyst reduction and regeneration, simultaneous flow through all six beds is used. The reproducibility of the system was first assessed with whole biomass pyrolysis along with pyrolysis of calibration standards. Initial work on this system evaluated two FCC catalysts, equilibrium catalyst (E-cat), and a proprietary catalyst from Johnson Matthey specifically design for co-processing of bio-oil with vacuum gas oil (VGO). This work used model compounds and VGO which illuminated differences in products produced by the catalysts.

biomass↗

Insights into Tetravalent Np Speciation in HNO 3 through Spectroelectrochemistry and Multivariate Analysis

In situ optical spectroscopy, spectropotentiometry, and multivariate analysis were applied to the Np(IV) nitrate system to better understand speciation and quantify HNO 3 concentration. Thin-layer spectropotentiometry, or spectroelectrochemistry, was leveraged to isolate and stabilize Np(IV) without compromising the solution conditions and generate representative Vis-NIR absorption spectra from 0.5 to 10 M HNO 3 and benchmark the corresponding Np(IV) molar absorptivity coefficients. Spectra were described with principal component analysis (PCA) to identify the purest Np(IV) absorbance spectra among other oxidation states [e.g., Np(V/VI)] at each acid concentration and then to identify the primary sources of variance within each Np(IV) spectrum with respect to Np(IV) nitrate complexes. Then, partial least-squares regression (PLSR) and support vector regression (SVR) models were built to predict HNO 3 concentration from the Np(IV) spectral data. The nonlinear SVR model outperformed the linear PLSR model for the HNO 3 concentration predictions. Finally, the inclusion of spectra collected in edge and center point HNO 3 concentrations in the calibration set was determined to be crucial for producing models with strong predictive capabilities. The multivariate approach used in this study makes it possible to quantify HNO 3 concentration solely based on Np(IV) absorption spectra, which is essential to quantifying processing streams in various online monitoring applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluating Optical Techniques to Characterize Solid State Samples for the Pu-238 Supply Program

This report documents steps that have been taken to establish advanced characterization capabilities for solid-state samples to support the 238 Pu Supply Program. The program has already invested significantly in spectroscopy and online monitoring development for liquid processes. Many of the data, analytical methods, and equipment could also be leveraged for the analysis of Np/Pu oxides and Np pellets to help classify material properties and link them to operations. The techniques described in this work include diffuse reflectance spectroscopy (DRS), Raman spectroscopy, and laser-induced breakdown spectroscopy (LIBS). Each technique is sensitive to various chemical and/or elemental species and can provide complimentary information to more standard methods such as powder x-ray diffraction and scanning electron microscopy. These options are remotely deployable via fiber-optic cables. DRS and Raman spectroscopy are already approved for glove box and hot cell work, but LIBS requires US Department of Energy approval for incorporation. Raman spectroscopy does require laser shielding, which means that DRS is the easiest method to implement. However, each technique provides complimentary data, and the most robust sample characterization could be achieved when all three, among other methods, are harnessed together. This report documents some of the progress made testing these capabilities, some of the challenges, and next steps to optimize the technology and integration strategies.

07 ISOTOPE AND RADIATION SOURCES↗