Search NASA⌕ Search

SEARCH · Search NASA

Results for “operations control center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

Deciphering Reaction Mechanisms of Molecular Proton Reduction Catalysts with Cyclic Voltammetry: Kinetic vs Thermodynamic Control

The kinetics and thermodynamics of elementary reaction steps involved in the catalytic reduction of protons to hydrogen define the reaction landscape for catalysis. The mechanisms can differ in the order of the elementary proton transfer, electron transfer, and bond-forming steps and can be further differentiated by the sites at which protons and electrons localize. Access to fully elucidated mechanistic, kinetic, and thermochemical details of molecular catalysts is crucial to facilitate the development of new catalysts that operate with optimal efficiency, selectivity, and durability. The mechanism by which a catalyst operates, as well as the kinetics and thermodynamics associated with the individual steps, can often be accessed through electroanalytical studies. Here, this Account details the application of cyclic voltammetry to interrogate reaction mechanisms and quantify the kinetics and thermodynamics of elementary reaction steps for a series of molecular catalysts that mediate electrochemical proton reduction. I distinguish the limiting scenarios wherein a catalyst operates under kinetic control vs thermodynamic control, with a focus on detecting how cyclic voltammetry features shift with proton source strength and concentration, as well as scan rate. For systems that operate under kinetic control, catalytic currents are observed at, or slightly positive toward, the formal potential for the redox process that triggers catalysis. Under thermodynamic control, catalytic responses shift as a function of the proton source pKa and effective pH of the solution. After drawing this distinction, we introduce the appropriate voltammetry experiments and accompanying analytical expressions for extracting key metrics from the data. To illustrate analytical strategies to quantify elementary reaction steps of catalysts operating under kinetic control, I describe our studies of proton reduction catalysts Co(dmgBF 2 ) 2 (CH 3 CN) 2 (dmgBF 2 = difluoroboryl-dimethylglyoxime) and [Ni(P 2 Ph N 2 Ph ) 2 ] 2+ (P 2 Ph N 2 Ph = 1,5-phenyl-3,7-phenyl-1,5-diaza-3,7-diphosphacyclooctane). Here, peak shift analysis, foot-of-the-wave analysis, and plateau current analysis are applied to data sets wherein voltammetric response are recorded as a function of catalyst concentration, proton source concentration, proton source strength, and scan rate to quantify rate constants for elementary proton transfer and bond-forming steps in a catalytic cycle. Further, the case study of [Ni(P 2 Ph N 2 Ph ) 2 ] 2+ illustrates how complementary spectroscopic methods can bolster the mechanistic assignment. Collectively, these two studies showcase how detailed mechanistic studies inform on rate-limiting elementary steps in catalysis and other key processes underpinning catalysis. Second, I present analytical strategies to interrogate catalysts operating under thermodynamic control, centered on the case study of [Ni II (P 2 Ph N 2 Bn ) 2 ] 2+ (P 2 Ph N 2 Bn = 1,5-dibenzyl-3,7-diphenyl-1,5-diaza-3,7-diphosphacyclooctane). Here, the application of nonaqueous Pourbaix theory to extract thermodynamic information is introduced, and the construction of a coupled Pourbaix diagram is detailed. This study identifies ligand-based protonation as the key process that places catalysis under thermodynamic control and influences the reaction mechanism. Together, the work detailed in this Account showcases the utility of electroanalytical methods to disentangle complex reaction mechanisms and extract key thermochemical and kinetic parameters for elementary steps of catalysis. Through detailed presentation of the key analytical expressions that underpin these analyses, this Account seeks to facilitate the adoption of cyclic voltammetry by the community to fully extract kinetic, thermochemical, and mechanistic information on electrochemical small-molecule activation.

catalysts↗

Bridging the Gap Between Modern UX Design and Particle Accelerator Control Room Interfaces

Accelerator control systems often represent relatively complex and safety-sensitive human-machine interfaces within process control industries. These systems are technically robust and reflect the cumulative integration of solutions built and adapted across decades. One of the regular, unfortunate casualties of provisional accelerator control system updates is their human-system interfaces (HSIs) which often lag behind modern usability and design standards. An additional challenge is that although there is a multitude of established human factors (HF), and user experience (UX) principles for everyday digital applications, there are very few (if any) established principles for complex and safety-critical applications for an accelerator. This paper argues for the importance of established HF and UX principles (herein referred to as human-centered design principles) into the development of accelerator HSIs, emphasizing the need for clarity, consistency, responsiveness, and cognitive accessibility. Drawing from HF/UX best practices and human-centered design, this paper discusses how these approaches can enhance operator performance, reduce human error, and improve accelerator personnel collaboration. Case studies from Accelerator Control Operations Research Network (ACORN) at Fermilab are explored to demonstrate how interfaces built with human-centered design principles can scale with system complexity while remaining intuitive and efficient for diverse user roles including operators, machine experts, and engineers. By bridging the gap between traditional control system design and modern human-centered design methods, this paper provides a roadmap for evolving accelerator HSIs into more usable, maintainable, and effective tools.

Hill, Rachael [Idaho Natl. Lab.]↗

Securing Grid Communications Infrastructure: Addressing Gaps Beyond NERC CIP Facility Perimeters

The North American electric grid relies on a complex communications infrastructure that extends beyond facility perimeters traditionally covered by NERC Critical Infrastructure Protection (CIP) standards. While CIP requirements have significantly strengthened cybersecurity within Electronic Security Perimeters, many operational communications—such as those between control centers, substations, and third-party networks—fall outside current regulatory scope. As grid modernization introduces new technologies and connectivity models, these external pathways present evolving security challenges. This brief explores the nature of these challenges, including emerging attack vectors and supply chain considerations, and highlights how ongoing grid transformation increases exposure to sophisticated threats. It outlines practical strategies and policy options to complement existing standards, such as expanding secure communications practices, enhancing supply chain transparency, and fostering collaboration among federal, state, and industry stakeholders. Near-term actions like encryption, authentication, and contractual safeguards can help reduce risk while longer-term frameworks are developed to ensure resilient and secure grid operations.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Online Detection of Power Grid Anomalies via Federated Learning

Data from sensors is critical for advanced applica- tions that support efficient, reliable, and resilient electric grid operations. Historically, data from phasor measurement units (PMU) has been utilized to develop a wide variety of wide area control and protection applications suitable for power grid control centers. However, until now, most of these could not be deployed for automated operations due to a set of data corruption challenges and uncertainty in the incoming data pipeline. In this paper, we address the problem of detecting different variety of anomalies that are evident in different high- speed power grid measurements. The paper discusses a workflow for handling problems with data acquisition and highlights some of the key findings suitable for anomaly detection in a centralized and distributed environment. The effectiveness of the proposed method was demonstrated with results utilizing realistic PMU datasets

Shinkle, Matthew W.↗

TRIZ-Based Design Improvement for Facilitating Transmission Control Unit Remanufacturing

Design for Remanufacturing (DfRem) centers on enhancing product design and operations to facilitate remanufacturing while increasing both economic and environmental sustainability. DfRem requires a comprehensive understanding of product characteristics, production conditions, and operational constraints. Thus, DfRem requires a systematic methodology to identify and implement alternative designs. Among many critical steps in remanufacturing, disassembly is essential because it directly supports remanufacturing by separation of product components for cleaning, inspection, and other subsequent process steps. This study proposes a TRIZ-based framework to improve product design for disassembly in support of remanufacturing. The framework is applied to a transmission control unit (TCU) case study. The current TCU design prevents remanufacturing due to the sealant-based component joinery, which complicates disassembly and risks damaging the printed circuit board (PCB). After defining technical contradictions for the TCU product design and reviewing the suggested TRIZ principles to solve the conflicts, a cantilever snap-fit design alternative is developed. The economic feasibility of the snap-fit design is assessed by comparing the current and snap-fit design costs for three life cycles. The cost analysis demonstrates that the cost of the snap-fit design remains the same as the current design. Additionally, the snap-fit design offers substantial cost savings for three life cycles compared to the current design. We demonstrate how snap-fit design supports both environmental and economic sustainability.

42 ENGINEERING↗

Risk-based System Upgrade Planning for AOT-IC [Capstone Project]

The Accelerator Operations and Technology Instrumentation and Controls Group (AOT IC) at the Los Alamos Neutron Science Center (LANSCE) has established a comprehensive risk-based system upgrade planning strategy which has been utilized as a tool to prioritize system upgrade projects for the past several years. A challenge with the current system is that the group often lacks the data to quantify the probability and impact of system failures, so the group often relies instead on qualitative risk assessments as well as evaluations of a potential upgrade project’s alignment with group strategy and vision to prioritize projects. A proposed framework to enable quantitative risk probability and impact assessments has been developed and tested on three pilot systems chosen to broadly represent the types and conditions of equipment used by the group. The proposed framework incorporates availability data gathered from the LANSCE control room logbooks and the LANSCE work control system, as well as a system health evaluation which is conducted from a variety of resources to assess the probability of equipment failure. The impact of system failure is viewed from the perspective of impact on mission and schedule, where spares status, system documentation status, and the functional distribution of deployed systems are used to quantify these impacts.

43 PARTICLE ACCELERATORS↗

Automated Vehicle Feasibility Study

This study collected automated vehicle (AV) performance data on public roadways in Athens, Ohio. The route for the study contained a combination of roads with different functional classifications, conditions, annual average daily traffic, and ownership responsibilities for maintenance and repair. Preparation for the public road deployment was done in a controlled environment at Transportation Research Center’s SMARTCenter, a dedicated AV test facility in East Liberty, Ohio. Researchers analyzed data and extracted insights relevant for both AV developers and infrastructure owners and operators. The study found that rural environments offer a unique set of roadway features such as hills and curves, which can challenge the driving behavior of an AV. Rural regions can also contain a large number of low-traffic gravel roads that lack pavement markings, which appear to be a crucial infrastructure element for operation of current generation AVs. Similarly, the presence of well-maintained lane lines along curves can influence the AV’s roadway departure tendencies. The study found that curvature-related behavior of an AV is also influenced by driving speed on the roadway segment. Such findings were consistent regardless of the time of day along the route or season of data collection. However, commentary about AV performance in active adverse weather cannot be made, as this is still an area of active research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Atomic-scale imaging and charge state manipulation of NV centers by scanning tunneling microscopy

Nitrogen-vacancy (NV) centers in diamond are among the most promising solid-state qubit candidates, owing to their exceptionally long spin coherence times, efficient spin-photon coupling, room-temperature operation, and steadily advancing fabrication and integration techniques. Despite significant progress in the field, atomic-scale characterization and control of individual NV centers have remained elusive. In this work, we utilize a conductive graphene capping layer to enable direct imaging and manipulation of NV - defects via scanning tunneling microscopy (STM). By investigating over 40 individual NV - centers, we identify their spectroscopic signatures and spatial configurations. Our dI/dV conductance spectra reveal the ground state resonance approximately 300 meV below the Fermi level and density-of-states maps uncover a two-lobed wavefunction aligned along the [111] crystallographic direction. Remarkably, we demonstrate the ability to manipulate the charge state of the NV centers from NV - to NV 0 through STM tip-induced gating. This work represents a significant advance in the atomic-scale imaging, spectroscopic characterization, and charge-state manipulation of NV centers, potentially paving the way for future quantum device development.

Raghavan, Arjun [Univ. of Illinois at Urbana-Champ↗

Energy Research Frontier Center: Photonics at Thermodynamic Limits

The Photonics at Thermodynamic Limits (PTL) EFRC strives to achieve photonic operations at thermodynamic limits by controlling the flow of photons, electrons, and phonons in atomically architected materials, enabling entirely new energy conversion systems. To achieve this mission, the EFRC united leading researchers in layered and nanostructured materials synthesis, electromagnetic theory, first‐principles quantum theory of materials, and advanced characterization of excited state phenomena. The two-year extension of the EFRC has finished several key efforts started in the EFRC in the previous funding period.

36 MATERIALS SCIENCE↗

Architectural Approaches for Integrating ADMS and DERMS: Challenges, Comparisons, and Real-World Use Cases

The electrical distribution landscape is rapidly transforming due to the proliferation of distributed energy resources (DERs) such as solar panels, wind turbines, battery storage systems, combined heat and power units, and electric vehicles, introducing variability and uncontrollability that traditional grid operators are ill-equipped to manage. This transformation is further accelerated by advancements in Information and Communication Technology infrastructure that connects control centers with end devices, demanding automation and a deeper understanding of new technologies by utility personnel. Advanced grid control techniques using system-level optimization, Artificial Intelligence, and Machine Learning at the enterprise level and distributed level are evolving to address these issues. There is also an opportunity to utilize the enormous data created by these new DER technologies in the grid. Advanced Distribution Management Systems (ADMS) and Distributed Energy Resource Management Systems (DERMS) are critical in addressing these challenges by automating grid operations and enhancing reliability. Given the relatively recent development of ADMS and DERMS, and the still relatively low level of ADMS and DERMS deployment in the industry, there is a notable deficiency in the comprehensive understanding of the challenges and benefits associated with these new technologies, especially with their complementary natures and integration architectures. This paper aims to bridge the knowledge gap in ADMS and DERMS integration, presenting three distinct integration architectures currently available, and discussing the challenges and benefits of each architecture to guide utilities, industry professionals, and researchers in optimizing grid management and decision-making processes for a resilient and efficient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

South Asia Group for Energy - Sri Lanka

Sri Lanka set a target of generating 70% of its electricity from renewable energy sources by 2030. This goal includes the addition of 5.8 GW of renewable power capacity, comprising hydropower, solar, wind, and biomass, between 2023 and 2030, with an interim target of adding 2.5 GW of renewable capacity by 2026. To accomplish this, Sri Lanka's power grid needs significant transformation and modernization to handle the integration of variable renewable energy sources effectively. The South Asia Group for Energy (SAGE) is helping Sri Lanka's grid operator, the Ceylon Electricity Board (CEB), understand the gaps for operating the grid with higher renewable share and identifying technology and research requirements to establish a variable renewable energy control center.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Digital Twin User Guide for Chelan County Public Utility District

This user manual offers a comprehensive guide for developing a Digital twin (DT) of a Kaplan turbine at Chelan County Public Utility District (Chelan PUD) using neural networks. As variable renewable generation expands, hydropower units must operate with optimal efficiency and stability. For Kaplan machines, this flexibility is achieved through coordinated control of guide vane (wicket gates) opening and runner blade pitch, which amplifies the plant’s inherent nonlinear behavior and challenges traditional physics-only modeling. The efficiency of the Kaplan turbine varies with different combinations of the guide vans (wicket gate) opening and the blade angle. Each guide van opening and blade angle has a corresponding highest efficiency point, forming a cam relationship that represents the optimal combination.The discharge of a hydraulic turbine is controlled by the opening angle of the guide vans. Therefore, for each value of head, there is a certain guide van opening and blade angle that corresponds to the highest efficiency. For a given head, different combinations of the guide van opening and blade angle have different efficiencies. Therefore, coordinate cam curves are used to describe the relationship between the wicket gate opening and blade angle with different water head. To address these challenges, the manual details a data-driven modeling and learning workflow centered on structured neural networks. The approach is designed to forecast critical operational variables—discharge flow, net head, penstock (or scroll-case) pressure, and generator electrical outputs—by leveraging real-time inputs such as the generator power control setpoint, exciter field current and field voltage, together with hydromechanical commands (e.g., gate position and, when available, runner blade-pitch angle). The neural models are trained and validated on operational data from a Kaplan unit operated by Chelan PUD, demonstrating that the structured NN architecture can learn the coupled gate–blade–electrical dynamics. The result is a robust DT that improves situational awareness and supports data-informed decision-making for Chelan PUD’s Kaplan turbine operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adapting Grid Criticality for Data Centers

This presentation explores the evolving definition of “critical load” in the electric grid, emphasizing the growing importance of digital infrastructure—particularly data centers—in grid resilience, restoration, and modernization. As utilities increasingly rely on AI-driven analytics and software-defined control systems, data centers have shifted from passive electricity consumers to essential computational hubs that enable National Critical Functions (NCFs) and support real-time grid operations. The deck examines the scale and impact of digital loads, the need for grid modernization to manage rapid load growth, and the diverse computing paradigms required for AI deployment. It introduces a tiered taxonomy for classifying critical loads, highlights operational dependencies between the grid and digital infrastructure, and discusses policy implications for integrating data centers into emergency planning and restoration protocols. Through case studies and practical frameworks, the presentation provides actionable insights for utilities, regulators, and planners navigating the digital transformation of the power sector.