Search NASA⌕ Search

SEARCH · Search NASA

Results for “pH detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Aromatic Diimides - Potential Dyes for Use in Smart Films and Fibers

New aromatic diimide fluorescent dyes have been prepared with potential for use as chemical sensors and in chromogenic polymers. These dyes have been designed to utilize excited state electron transfer reactions as the means for sensing chemical species. For example, an aniline en-dcapped anthryl diimides functions effectively as an "on-off" sensor for pH and the detection of phosphoryl halide based chemical warfare agents, such as Sarin. In the absence of analytes, fluorescence from this dye is completely quenched by excited state electron transfer from the terminal amines. Reaction of these amines inhibits electron transfer and activates the fluorescence of the dye. Another substituted anthryl diimide is presented with the capability to detect pH and nitroaromatic compounds, such as TNT. Films prepared by doping small amounts (less than 0.1 weight percent) of several of these dyes in polymers such as linear low density polyethylene exhibit thermochromism. At room temperature, these films fluoresce reddish-orange. Upon heating, the fluorescence turns green. This process is reversible cooling the films to room temperature restores the orange emission.

Meador, Michael A.↗

Changes in root cap pH are required for the gravity response of the Arabidopsis root

Although the columella cells of the root cap have been identified as the site of gravity perception, the cellular events that mediate gravity signaling remain poorly understood. To determine if cytoplasmic and/or wall pH mediates the initial stages of root gravitropism, we combined a novel cell wall pH sensor (a cellulose binding domain peptide-Oregon green conjugate) and a cytoplasmic pH sensor (plants expressing pH-sensitive green fluorescent protein) to monitor pH dynamics throughout the graviresponding Arabidopsis root. The root cap apoplast acidified from pH 5.5 to 4.5 within 2 min of gravistimulation. Concomitantly, cytoplasmic pH increased in columella cells from 7.2 to 7.6 but was unchanged elsewhere in the root. These changes in cap pH preceded detectable tropic growth or growth-related pH changes in the elongation zone cell wall by 10 min. Altering the gravity-related columella cytoplasmic pH shift with caged protons delayed the gravitropic response. Together, these results suggest that alterations in root cap pH likely are involved in the initial events that mediate root gravity perception or signal transduction.

NASA Discipline Plant Biology↗

The potential role of salt abuse on the risk for kidney stone formation

The kidney stone-forming risk of a high sodium diet was evaluated by assessing the effect of such a diet on the crystallization of stone-forming salts in urine. Fourteen normal subjects participated in 2 phases of study of 10 days duration each, comprising a low sodium phase (basal metabolic diet containing 50 mmol. sodium per day) and a high sodium phase (basal diet plus 250 mmol. sodium chloride per day). The high sodium intake significantly increased urinary sodium (34 +/- 12 to 267 +/- 56 mmol. per day), calcium (2.73 +/- 1.03 to 3.93 +/- 1.51 mmol. per day) and pH (5.79 +/- 0.44 to 6.15 +/- 0.25), and significantly decreased urinary citrate (3.14 +/- 1.19 to 2.52 +/- 0.83 mmol. per day). Arterialized venous blood bicarbonate and total serum carbon dioxide concentrations decreased significantly during the high sodium diet, whereas serum chloride concentration increased. However, no change in arterialized venous pH was detected. Thus, a high sodium intake not only increased calcium excretion, but also increased urinary pH and decreased citrate excretion. The latter effects are probably due to sodium-induced bicarbonaturia and a significant decrease in serum bicarbonate concentration, respectively. Commensurate with these changes, the urinary saturation of calcium phosphate (brushite) and monosodium urate increased, and the inhibitor activity against calcium oxalate crystallization (formation product) decreased. The net effect of a high sodium diet was an increased propensity for the crystallization of calcium salts in urine.

Non-NASA Center↗

Visible Wavelength Spectroscopy of Ferric Minerals: A Key Tool for Identification of Ancient Martian Aqueous Environments

The mineralogic signatures of past aqueous alteration of a basaltic Martian crust may include iron oxides and oxyhydroxides, zeolites, carbonates, phyllosilicates, and silica. The identities, relative abundances, and crystallinities of the phases formed in a particular environment depend on physicochemical conditions. At one extreme, hot spring environments may be characterized by smectite-chlorite to talc-kaolinite silicate assemblages, plus crystalline ferric oxides dominated by hematite. However, most environments, including cold springs, pedogenic layers, and ponded surface water, are expected to deposit iron oxides and oxyhydroxides, carbonates, and smectite-dominated phyllosilicates. A substantial fraction of the ferric iron is expected to occur in nanophase form, with the exact mineralogy strongly influenced by Eh-pH conditions. Detection of these phases has been an objective of a large body of terrestrial telescopic, Mars orbital, and landed spectral investigations and in situ compositional measurements. However, clear identifications of many of these phases is lacking. Neither carbonate nor silica has been unequivocally detected by any method. Although phyllosilicates may occur near the limit of detection by remote sensing, in general they appear to occur in only poorly crystalline form. In contrast, compelling evidence for ferric iron minerals has been gathered by recent telescopic investigations, the Imager for Mars Pathfinder (IMP), and the Thermal Emission Spectrometer (TES) on the Mars Global Surveyor (MGS). These data yield two crucial findings: (1) In the global, high spatial resolution TES data set, highly crystalline ferric iron (as coarse-grained 'gray' hematite) has been recognized but with only very limited spatial occurrence and (2) Low-resolution telescopic reflectance spectroscopy, very limited orbital reflectance spectroscopy, and landed multispectral imaging provide strong indications that at least two broad classes of ferric iron minerals are commonplace in non-dust covered regions.

Murchie, Scott L.↗

Wall to membrane linkers, stretch activated channels, and the detection of tension, voltage, temperature, auxin, and pH

Introduction. The higher plant is a heterogeneous, mechanically prestressed structure continually subject to shifting forces. When a cell grows in a plant at gravitropic equilibrium, it must create localized maxima of shear in walls of neighboring cells. Such mechanical stress and strain are likely detected in a variety of ways. However, tension-sensitive ion channels are of particular interest because it appears that they are elaborately evolved for sensory function. We hypothesize that 1) the patchy patterns of high shear are focused via wall-to-membrane linkers onto the plasma membrane, where 2) they are translated by mechanosensory cation channels into corresponding patterns of high cytosolic Ca2+, which 3) initiate local enhancement of wall expansion. Further, we hypothesize that the local promotion of enhancement is achieved at least in part by local intensification of auxin transport across the plasma membrane. By implication, when an organ is asymmetrically pressed, rubbed, or bent or when it is displaced in the gravitational field, the net asymmetry of shear stress occurring across the organ would lead to asymmetric redistribution of auxin and corrective asymmetric growth. We shall describe a representative mechanosensitive Ca(2+) -selective cation channel (MCaC) with susceptibilities to xenobiotics implicating it as a force transducer in thigmo- and gravitropism. Then, we shall consider whether a putative wall-to-membrane linker (WML) could be a key feature of the molecular architecture permitting the stress distributed in the wall system to be focused on the channels.

NASA Discipline Number 40-50↗

Time-to-Fatigue and Intramuscular pH Measured via NIRS During Handgrip Exercise in Trained and Sedentary Individuals

In exercising muscles force production and muscular endurance are impaired by a decrease in intramuscular pH. The effects of aerobic training (AT) on preventing acidosis and prolonging exercise time in muscles not specifically targeted by the training are unknown. Purpose: To compare interstitial pH, measured non-invasively with near infrared spectroscopy (NIRS), in the flexor digitorum profundus (FDP) during rhythmic handgrip exercise in sedentary subjects and those who participate in AT activities that target the lower body. Methods: Maximal isometric force (MIF) was measured on three separate days in AT (n=5) and sedentary (n=8) subjects using a handgrip dynamometer (HGD). Isometric muscular endurance (IME) was measured during five trials, each separated by at least 48 hrs. For each IME trial subjects rhythmically squeezed (4 sec at 40% of MVC) and relaxed (2 sec) to fatigue or failure to reach the target force in three consecutive contractions or four non-consecutive contractions. Interstitial pH was derived from spectra collected using a NIRS sensor adhered to the skin over the FDP. The first four IME trials served to familiarize subjects with the protocol; the fifth trial was used for analysis. NIRS-derived pH was averaged in 30 sec increments. Between group differences in MIF and exercise time were tested using paired t-tests. A repeated measures ANOVA was used to analyze effects of AT and exercise time on pH. Results: MIF was not different between groups (mean SD; aerobic=415.6 95.4 N vs. sedentary =505.1 107.4 N). Time to fatigue was greater in the AT than in the sedentary group (mean SD: 611 173 sec vs. 377 162 sec, p<0.05). pH was not different between groups at any time point. Average pH decreased (p<0.05) in both groups from rest (pH=7.4) through 90 sec of exercise (pH=6.9), but did not decrease further throughout the remainder of exercise. Conclusion: Although between group differences in pH were not detected, differences during the onset of exercise may exist with a more frequent sampling. AT individuals appear to better tolerate decreased interstitial pH and are able to continue submaximal muscular work, possibly due to psychological familiarization to muscular fatigue and/or systemic physiological benefits.

Everett, M. E.↗

Water system virus detection

A monitoring system developed to test the capability of a water recovery system to reject the passage of viruses into the recovered water is described. A nonpathogenic marker virus, bacteriophage F2, is fed into the process stream before the recovery unit and the reclaimed water is assayed for its presence. Detection of the marker virus consists of two major components, concentration and isolation of the marker virus, and detection of the marker virus. The concentration system involves adsorption of virus to cellulose acetate filters in the presence of trivalent cations and low pH with subsequent desorption of the virus using volumes of high pH buffer. The detection of the virus is performed by a passive immune agglutination test utilizing specially prepared polystyrene particles. An engineering preliminary design was performed as a parallel effort to the laboratory development of the marker virus test system. Engineering schematics and drawings of a fully functional laboratory prototype capable of zero-G operation are presented. The instrument consists of reagent pump/metering system, reagent storage containers, a filter concentrator, an incubation/detector system, and an electronic readout and control system.

Fraser, A. S.↗

Equivalent Dipole Vector Analysis for Detecting Pulmonary Hypertension

Various 12-lead ECG criteria have been established to detect right ventricular hypertrophy as a marker of pulmonary hypertension (PH). While some criteria offer good specificity they lack sensitivity because of a low prevalence of positive findings in the PH population. We hypothesized that three-dimensional equivalent dipole (ED) model could serve as a better detection tool of PH. We enrolled: 1) 17 patients (12 female, 5 male, mean age 57 years, range 19-79 years) with echocardiographically detected PH (systolic pulmonary arterial pressure greater than 35 mmHg) and no significant left ventricular disease; and 2) 19 healthy controls (7 female, 12 male, mean age 44, range 31-53 years) with no known heart disease. In each subject we recorded a 5-minute high-resolution 12-lead conventional ECG and constructed principal signals using singular value decomposition. Assuming a standard thorax dimension of an adult person with homogenous and isotropic distribution of thorax conductance, we determined moving equivalent dipoles (ED), characterized by the 3D location in the thorax, dipolar strength and the spatial orientation, in time intervals of 5 ms. We used the sum of all ED vectors in the second half of the QRS complex to derive the amplitude of the right-sided ED vector (RV), if the orientation of ED was to the right side of the thorax, and in the first half the QRS to derive the amplitude of the left-sided vector (LV), if the orientation was leftward. Finally, the parameter RV/LV ratio was determined over an average of 256 complexes. The groups differed in age and gender to some extent. There was a non-significant trend toward higher RV in patients with PH (438 units 284) than in controls (280 plus or minus 140) (p = 0.066) but the overlap was such that RV alone was not a good predictor of PH. On the other hand, the RV/LV ratio was a better predictor of PH, with 11/17 (64.7%) of PH patients but only in 1/19 (5.3%) control subjects having RV/LV ratio greater than or equal to 0.70 (p less than 0.001). The use of ED for evaluating PH shows good specificity at a reasonable sensitivity. The results are limited due to the small study groups and differences in age and gender, but further investigations are warranted, including of ED's diagnostic accuracy for PH versus that of other proposed ECG and VCG criteria.

Harlander, Matevz↗

Electrochemical detection device

A standard pH reference electrode and a platinum cathodic electrode are positioned in a container with suitable nutrient medium for microbial growth plus the sample to be tested. The two electrodes are connected to electronic circuitry including an up/down counter whicn counts up for the first 80 minutes after a test has initiated. Then the potential between the two electrodes is tracked by the electronic circuitry and after there is a change of 10 mv a signal is sent to the up/down counter to cause it to reverse its count. When there is a additional 20 mv change in the potential between the two electrodes another signal is sent to the up/down counter, signalling it to stop. The resulting count on the counter is equal to the length of time for the inoculum to begin the production of measurable amounts of H2 after inoculation.

Young, R. N.↗

Determination of the Corrosive Conditions Present within Aircraft Lap-Splice Joints

The complexity of airframe structure lends itself to damage resulting from crevice corrosion. Fuselage lap-splice joints are a particularly important structural detail in this regard because of the difficulty associated with detection and measurement of corrosion in these occluded regions. The objective of this work is to develop a laboratory corrosion test protocol to identify the chemistry to which lap joints are exposed and to develop a model of the corrosion within the joints. A protocol for collecting and identifying the chemistry of airframe crevice corrosion has been developed. Capillary electrophoresis (CE) is used to identify the ionic species contained in corrosion product samples removed from fuselage lap splice joints. CE analysis has been performed on over sixty corrosion product samples removed from both civilian and military aircraft. Over twenty different ions have been detected. Measurements of pH of wetted corroded surfaces indicated an alkaline occluded solution. After determining the species present and their relative concentrations, the resultant solution was reproduced in bulk and electrochemical tests were performed to determine the corrosion rate. Electrochemical analyses of the behavior of AA2024-T3 in these solutions gave corrosion rates of up to 250 microns per year (10 mpy). Additional tests have determined the relative importance of each of the detected ions in model solutions used for future predictive tests. The statistically significant ions have been used to create a second generation solution. Laboratory studies have also included exposure tests involving artificial lap joints exposed to various simulated bulk and crevice environments. The extent and morphology of the attack in artificial lap joints has been compared to studies of corroded samples from actual aircraft. Other effects, such as temperature and potential, as well as the impact of the environment on fatigue crack growth have also been studied.

Lewis, Karen S.↗

Phosphocreatine kinetics at the onset of contractions in skeletal muscle of MM creatine kinase knockout mice

Phosphocreatine (PCr) depletion during isometric twitch stimulation at 5 Hz was measured by (31)P-NMR spectroscopy in gastrocnemius muscles of pentobarbital-anesthetized MM creatine kinase knockout (MMKO) vs. wild-type C57B (WT) mice. PCr depletion after 2 s of stimulation, estimated from the difference between spectra gated to times 200 ms and 140 s after 2-s bursts of contractions, was 2.2 +/- 0.6% of initial PCr in MMKO muscle vs. 9.7 +/- 1.6% in WT muscles (mean +/- SE, n = 7, P < 0.001). Initial PCr/ATP ratio and intracellular pH were not significantly different between groups, and there was no detectable change in intracellular pH or ATP in either group after 2 s. The initial difference in net PCr depletion was maintained during the first minute of continuous 5-Hz stimulation. However, there was no significant difference in the quasi-steady-state PCr level approached after 80 s (MMKO 36.1 +/- 3.5 vs. WT 35.5 +/- 4.4% of initial PCr; n = 5-6). A kinetic model of ATPase, creatine kinase, and adenylate kinase fluxes during stimulation was consistent with the observed PCr depletion in MMKO muscle after 2 s only if ADP-stimulated oxidative phosphorylation was included in the model. Taken together, the results suggest that cytoplasmic ADP more rapidly increases and oxidative phosphorylation is more rapidly activated at the onset of contractions in MMKO compared with WT muscles.

NASA Discipline Cell Biology↗

Isoelectric focusing analysis of antibody clonotype changes occurring during immune responses using immobilized pH gradients

Serum was collected from rabbits at 2-day intervals following a single injection with tetanus toxoid or at weekly intervals following multiple injections with Micrococcus lysodeikticus cell walls. These sera were analyzed for the presence of individual clonotypes of specific antitetanus or antimicrococcal antibodies by isoelectric focusing in immobilized pH gradients with added carrier ampholytes followed by affinity immunoblotting. The affinity immunoblots obtained clearly defined both the rapid disappearance and late appearance of distinct subsets of antibody clonotypes during the response. These data demonstrate the application of affinity immunoblotting combined with immobilized pH gradients for detecting the subtle changes in specific antibody clonotype patterns which occur during an immune response.

Knisley, Keith A.↗

Effect of Sulfur Concentration and PH Conditions on Akaganeite Formation: Understanding Akaganeite Formation Conditions in Yellowknife Bay, Gale Crater, Mars

The Chemistry and Mineralogy Instrument (CHEMIN) on board the Mars Science Laboratory (MSL) Curiosity Rover identified minor amounts of akaganeite (beta-FeOOH) at Yellowknife Bay, Mars. There is also evidence for akaganeite at other localities on Mars from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM). Akaganeite is an iron(III) hydroxide with a hollandite- like structure and Cl in its tunnels. Terrestrial akaganeite usually forms in Cl-rich environments under acidic, oxidizing conditions. Previous studies of akaganeite have revealed that akaganeite formation is affected by the presence of sulfate (hereafter denoted as S. The prediction of circumneutral pH coupled with the detection of S at Yellowknife Bay dictate that work is needed to determine how S and pH together affect akaganeite formation. The goal of this work is to study how changes in both S concentration and pH influence akaganeite precipitation. Akaganeite formation was investigated at S/Cl molar ratios of 0, 0.017, 0.083, 0.17 and 0.33 at pH 1.5, 2, and 4. Results are anticipated to provide combined S concentration and pH constraints on akaganeite formation in Yellowknife Bay and elsewhere on Mars. Knowledge of solution pH and S concentrations can be utilized in understanding microbial habitability potential on the Martian surface.

Fox, A.↗

Electrochemical Detection of Multiple Bioprocess Analytes

An apparatus that includes highly miniaturized thin-film electrochemical sensor array has been demonstrated as a prototype of instruments for simultaneous detection of multiple substances of interest (analytes) and measurement of acidity or alkalinity in bioprocess streams. Measurements of pH and of concentrations of nutrients and wastes in cell-culture media, made by use of these instruments, are to be used as feedback for optimizing the growth of cells or the production of desired substances by the cultured cells. The apparatus is designed to utilize samples of minimal volume so as to minimize any perturbation of monitored processes. The apparatus can function in a potentiometric mode (for measuring pH), an amperometric mode (detecting analytes via oxidation/reduction reactions), or both. The sensor array is planar and includes multiple thin-film microelectrodes covered with hydrous iridium oxide. The oxide layer on each electrode serves as both a protective and electrochemical transducing layer. In its transducing role, the oxide provides electrical conductivity for amperometric measurement or pH response for potentiometric measurement. The oxide on an electrode can also serve as a matrix for one or more enzymes that render the electrode sensitive to a specific analyte. In addition to transducing electrodes, the array includes electrodes for potential control. The array can be fabricated by techniques familiar to the microelectronics industry. The sensor array is housed in a thin-film liquid-flow cell that has a total volume of about 100 mL. The flow cell is connected to a computer-controlled subsystem that periodically draws samples from the bioprocess stream to be monitored. Before entering the cell, each 100-mL sample is subjected to tangential-flow filtration to remove particles. In the present version of the apparatus, the electrodes are operated under control by a potentiostat and are used to simultaneously measure the pH and the concentration of glucose. It is anticipated that development of procedures for trapping more enzymes into hydrous iridium oxide (and possibly into other electroactive metal oxides) and of means for imparting long-term stability to the transducer layers should make it possible to monitor concentrations of products of many enzyme reactions for example, such key bioprocess analytes as amino acids, vitamins, lactose, and acetate.

Rauh, R. David↗

Chemical-Sensing Cables Detect Potential Threats

Intelligent Optical Systems Inc. (IOS) completed Phase I and II Small Business Innovation Research (SBIR) contracts with NASA's Langley Research Center to develop moisture- and pH-sensitive sensors to detect corrosion or pre-corrosive conditions, warning of potentially dangerous conditions before significant structural damage occurs. This new type of sensor uses a specially manufactured optical fiber whose entire length is chemically sensitive, changing color in response to contact with its target, and demonstrated to detect potentially corrosive moisture incursions to within 2 cm. After completing the work with NASA, the company received a Defense Advanced Research Projects Agency (DARPA) Phase III SBIR to develop the sensors further for detecting chemical warfare agents, for which they proved just as successful. The company then worked with the U.S. Department of Defense (DoD) to fine tune the sensors for detecting potential threats, such as toxic industrial compounds and nerve agents. In addition to the work with government agencies, Intelligent Optical Systems has sold the chemically sensitive fiber optic cables to major automotive and aerospace companies, who are finding a variety of uses for the devices. Marketed under the brand name Distributed Intrinsic Chemical Agent Sensing and Transmission (DICAST), these unique continuous-cable fiber optic chemical sensors can serve in a variety of applications: Corrosive-condition monitoring, aiding experimentation with nontraditional power sources, as an economical means of detecting chemical release in large facilities, as an inexpensive "alarm" systems to alert the user to a change in the chemical environment anywhere along the cable, or in distance-resolved optical time domain reflectometry systems to provide detailed profiles of chemical concentration versus length.

Source record↗

The Chemistry and Mineralogy of Mars Soils: A Tour of Landed Mission Results from the Last 45 years

Eight landed missions demonstrated that martian soils (defined as loose, unconsolidated surface material) consist of basaltic mineralogy, iron (hydr)oxides, amorphous material, sulfate, chloride, (per)chlorate, nitrate, carbonate, and possible organic C. The Viking Lander 1 and 2 (1976), Mars Pathfinder (1997), and Mars Exploration Rover (MER-A,B) (2004) missions determined that martian soil was similar at all landing sites by having mafic chemistry, high S (~ 7 wt.% SO3) and Cl (0.7 wt.%), and spectral detections of poorly crystalline and crystalline Fe-(hydr)oxide phases. The MER Mössbauer spectrometers detected Fe-bearing olivine and pyroxene along with magnetite, nano-phase Fe-oxides (npOx), hematite, and ferric sulfate. The 2008 Phoenix Lander instrumentation measured a soil pH of 7.7 and detected ~0.6 wt.% perchlorate, 3-5 wt.% Ca-rich carbonate and carbon (500 gC/g) consistent with oxidized organics and Fe-rich carbonate. The 2012 Mars Science Laboratory (MSL) rover (Gale Crater) through X-ray diffraction detected plagioclase feldspar, pyroxene, magnetite, hematite, anhydrite, and quartz, with the balance being composed of Si/Fe-containing amorphous (30 to 40 wt.%) material. MSL evolved gas analysis detected (per)chlorate (0.4 wt.% ClO4), nitrate (0.23 wt.%), along with minor Fe/Mg sulfate and oxidized organic C (~2000 gC/g). Limited pedogenesis may have occurred at the 2018 InSight landing site and in one Gusev Crater soil (MER-B) which have 3 to 10 cm-thick duricrust horizons consistent with atmospheric water vapor interactions with soil salts. Martian soil primary mineralogy was derived mostly from local rock (volcanic, sedimentary) that is largely basaltic planet wide. Secondary minerals [e.g., sulfate, chloride, perchlorate, nitrate, carbonate, Fe-(hydr)oxides] in martian soils formed from oxidative aqueous alteration processes and were likely derived from a combination of local sedimentary rock sources and the global bright dust. The Mars 2020 mission will collect soil for Earth return to enable a thorough assessment of the nature and origin of martian soil.

Mars↗

Chemical evolution. XXIX - Pyrimidines from hydrogen cyanide

Compounds obtained by hydrolysis of HCN oligomers formed by allowing pH 9.2, 0.1 M cyanide to stand at room temperature for 4 to 12 months were analyzed. Hydrolysis of HCN oligomers yielded 4,5-dihydroxypyrimidine and 5-hydroxyuracil; orotic acid was detected after hydrolysis at pH 8.5. A unified pathway from diaminofumaronitrile to the pyrimidines observed is suggested. As purines, pyrimidines and amino acids are released by hydrolysis of HCN oligomers in either acidic or mildly basic aqueous solutions, they could have been formed on the primitive earth in spite of fluctuations in pH. 4,5-dihydroxypyrimidines appear to be likely candidates for incorporation into primitive nucleic acids, as they should undergo Watson-Crick hydrogen bonding with adenine.

Ferris, J. P.↗