Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance index”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Online Prototype Toolset for Predicting and Optimizing P&T Performance (FY23 Status Report)

A new web-based toolset is being developed to support ongoing remediation optimization efforts and implementation of an adaptive site management strategy for the 200 West Area Pump-and-Treat (P&T) system at the Hanford Site. This toolset, comprising the well performance index tool and the well optimization pre-screening tool, will offer a user-friendly interface to predict and optimize the P&T well network’s performance at a preliminary level. Efforts in fiscal year (FY) 2023 focused on three main components: updating the existing deep learning model for predicting P&T performance, designing and developing a prototype of a web-based performance index tool, and initiating the conceptual design of the well optimization pre-screening tool. The well performance index tool is based on a pre-trained deep learning model that allows users to select a target contaminant and well screen length, then visualize the predicted performance of potential new wells across the site. The well optimization pre-screening tool includes two separate modules: the pre-computed scenario viewer, which organizes and visualizes offline optimization simulation results, and the quick analysis module, which provides real-time model prediction using user-specified well locations. In FY24, the plan is to add web-based applications to SOCRATES for both the well performance prediction tool and the optimization prescreening tool, with accompanying user and theory guides. These tools are intended to enable an accessible, easily applied, and transparent approach to remedy planning and decision-making.

97 MATHEMATICS AND COMPUTING↗

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

Developing an Energy-Conscious Traffic Signal Control System for Optimized Fuel Consumption in Connected Vehicle Environments

The project titled “Developing an Energy-Conscious Traffic Signal Control System for Optimized Fuel Consumption in Connected Vehicle Environments” addresses energy-related challenges associated with adaptive traffic control systems by integrating connected vehicles (CV) and connected infrastructure (CI). The system developed in this project, a CV-based adaptive traffic control system, aims to improve fuel consumption in mixed traffic environments by capitalizing on emerging CV and CI communication technologies, as well as leveraging recent advances in Artificial Intelligence (AI), optimization, and edge computing. The system was tested at the MLK Smart Corridor, an urban testbed managed by the University of Tennessee at Chattanooga (UTC) and the City of Chattanooga. The system was validated through extensive simulations, both Software-in-the-Loop (SILS) and Hardware-in-the-Loop (HILS), and was further implemented and tested in real-world conditions at several intersections along the corridor. The Fuel Consumption Performance Index (FC-PI) and the Ecological Performance Index (Eco-PI) were developed as the key components for evaluating the system’s impact on fuel consumption and emissions. These metrics provided a comprehensive means of understanding the impact of traffic signal control optimization in mixed traffic environments. The report presents an in-depth analysis of the Eco-PI, FC-PI, adaptive traffic control system integration, and the testing and field implementation of the system. The results demonstrate significant reductions in fuel consumption and emissions, showcasing the system’s capability to contribute to more sustainable urban traffic management. The report also documents the challenges encountered and recommendations for scaling and further improving the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of dietary supplementation of Lycium barbarum leaves on the growth performance, organ indexes and intestinal microflora of rats

This study was conducted to investigate both fruit and different levels of leaf supplementation on the growth performance, organ indices and intestinal microflora of rats. Twenty-five healthy male Sprague–Dawley rats were randomly divided into five groups. The rats in the control (NC) and positive control (PC) groups were fed by gavage a basal diet and a basal diet with 4 g/kg of L. barbarum fruit homogenate, respectively. The test (LD, MD, and HD) groups were fed basal diets with additional 2, 4, and 8 g/kg of L. barbarum leaf homogenate, respectively. The feeding period was 35 d. The result revealed that the rats in the LD group had the highest average weight gain ( p < 0.05). The cardiac and renal indexes in the LD and MD groups were significantly higher than in NC group, respectively ( p < 0.05). Diversity analysis revealed that adding low concentrations of L. barbarum leaf homogenates markedly reduced the Shannon index of the rats cecum ( p < 0.05). The relative abundance of Verrucomicrobiota was higher in the LD group than those in other groups ( p < 0.05). The relative abundance of Actinobacteriota was found significantly higher in PC group than others ( p < 0.05). The relative abundance of Akkermansia in LD group was the highest ( p < 0.05). The relative abundance of Romboutsia in the PC group was considerably higher than that in other groups. The relative abundance of Candidatus_Saccharimonas in the supplementation groups was appreciably lower than those found in other groups. The relative abundance of Alloprevotella was significantly lower in PC, LD, and MD groups than in NC and HD groups ( p < 0.05). The relative abundance of Oscillibacter was significantly higher in HD group than in other groups ( p < 0.05). Thus, L. barbarum leaf homogenate fed to rats could increase their growth performance, internal organ weights and additionally enhance the relative abundance of beneficial bacteria. Therefore, based on the obtained data in the current study, a dose of L. barbarum leaf homogenate supplemented with 2 g/kg in diet is recommended, however, further studies are required to confirm, especially in animals.

Guo, Yindi↗

Fluid dynamic and thermal performance of a slotted cylinder at low Reynolds number

The fluid dynamic and thermal performance of a circular cylinder with a slot parallel to the flow is numerically investigated. The study utilized the semi-implicit finite volume multi-material algorithm MPM-ICE, a component of the Uintah framework. The normalized slot width s/D ranges from 0.1 - 0.3, introducing an additional heat transfer surface area between ~ 10 and ~ 50%, and a mass reduction between ~ 13 and ~ 38% in the cylinder. We assumed two-dimensional incompressible flow and simulated a Reynolds number Re D between 100 and 1000. The slotted cylinders are found to have a total drag force reduction up to ~ 45%, compared to a solid cylinder despite the additional viscous drag force in the slot. Convection heat transfer is enhanced up to ~ 70%. Further, the slotted cylinder performance index, defined as the ratio of the heat rate to the drag force, increases up to maximum of ~ 3, indicating better overall thermal fluid performance. An entropy analysis showed the best performance index occurs at the highest Re D . Correlations for drag coefficient and Nusselt number are proposed along with an entropy optimization method.

42 ENGINEERING↗

Automated analysis of unlabeled PV data with Solar Data Tools software: Overview and feature updates

Distributed rooftop PV systems: ubiquitous, yet commonly have unlabeled data Difficult or impossible to form a performance index We developed Solar Data Tools (SDT), an open-source Python library for analyzing PV power (and irradiance) time-series data SDT enables analysis of unlabeled PV data—no model, no meteorological data, no performance index required Takes a statistical signal processing approach Data processing steps are largely pre-defined and automatic regardless of system type—from utility tracking systems to multi-pitch rooftop systems

Meyers-Im, Bennet E↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

An optimized FM-index library for nucleotide and amino acid search

Abstract Background Pattern matching is a key step in a variety of biological sequence analysis pipelines. The FM-index is a compressed data structure for pattern matching, with search run time that is independent of the length of the database text. Implementation of the FM-index is reasonably complicated, so that increased adoption will be aided by the availability of a fast and flexible FM-index library. Results We present AvxWindowedFMindex (AWFM-index), a lightweight, open-source, thread-parallel FM-index library written in C that is optimized for indexing nucleotide and amino acid sequences. AWFM-index introduces a new approach to storing FM-index data in a strided bit-vector format that enables extremely efficient computation of the FM-index occurrence function via AVX2 bitwise instructions, and combines this with optional on-disk storage of the index’s suffix array and a cache-efficient lookup table for partial k-mer searches. The AWFM-index performs exact match count and locate queries faster than SeqAn3’s FM-index implementation across a range of comparable memory footprints. When optimized for speed, AWFM-index is $$\sim $$ ∼ 2–4x faster than SeqAn3 for nucleotide search, and $$\sim $$ ∼ 2–6x faster for amino acid search; it is also $$\sim $$ ∼ 4x faster with similar memory footprint when storing the suffix array in on-disk SSD storage. Conclusions AWFM-index is easy to incorporate into bioinformatics software, offers run-time performance parameterization, and provides clients with FM-index functionality at both a high-level (count or locate all instances of a query string) and low-level (step-wise control of the FM-index backward-search process). The open-source library is available for download at https://github.com/TravisWheelerLab/AvxWindowFmIndex.

59 BASIC BIOLOGICAL SCIENCES↗

The Sustainability Index: a new tool to breed for reduced greenhouse-gas emissions intensity in Australian dairy cattle

Context The Australian dairy industry has a target to reduce greenhouse-gas (GHG) emissions intensity by 30% between 2015 and 2030. At the animal level, apart from nutritional modifications and other management practices, selecting animals that emit less GHG can be a cost-effective and long-term strategy. Given the world’s demand for protein is increasing, selecting for animals with lower GHG emissions per unit of production, i.e. emissions intensity, is a realistic approach that addresses the key issue of emissions reduction while maintaining farm productivity. Aim To develop a selection index for Australian dairy cattle to breed for reduced emissions intensity. Methods The Sustainability Index was built based on the existing Balanced Performance Index (BPI) but placed greater emphasis on production, survival, health and feed efficiency. Key results In August 2022, DataGene released the Sustainability Index that can be used by dairy farmers to select animals with lower environmental footprints. Compared with BPI, the weights for protein, fat, survival, mastitis resistance and feed efficiency increased by 2.6-, 1.4-, 2.8-, 1.3- and 3.8-fold respectively. It is expected that with the use of the Sustainability Index, emissions intensity will be reduced by 7.64%, 8.96% and 5.52% respectively in Holstein, Jersey and Red breeds by 2050, compared with the 2015 level. The corresponding values when selecting for BPI were 6.34%, 7.91% and 5.23% respectively. However, the trade-off in BPI when using the Sustainability Index will be AUD0.79, AUD0.83, AUD0.22 per cow per year for Holstein, Jersey and Red breeds respectively. Conclusions The current profit index BPI has contributed to reduction in emissions intensity. To enhance the rate of improvement in emissions intensity, the Sustainability Index can be used with minimal impacts on profit. Implications To breed for lower emissions intensity, farmers can select animals with high Sustainability Index values that are published on DataVat (datavat.com.au) and the Good Bulls App. To lower gross emissions, combinations of additional measures such as management of diet, adjustment to animal numbers, management of stored manure, and appropriate use of carbon neutral fertiliser, renewable fuels and energy, will need to be adopted on farms.

Agriculture↗

Reducing Uncertainty of Fielded Photovoltaic Performance (Final Technical Report)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. The FY19-21 Reducing Uncertainty project leveraged data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Specifically, we accomplished: report on field performance and degradation rates for high-efficiency silicon (HJT, PERC, IBC) and more conventional technologies; developed automated analysis techniques to quantify system performance (performance ratio, energy yield) and production shortfalls (soiling, degradation, availability); refined the RdTools software toolkit to bring standard, validated analysis techniques to bear on third-party data; analyzed and reported on large datasets including Treasury data and Lawrence Berkeley National Laboratory's Utility-Scale dataset to expand the high-quality degradation-rate histogram published previously; worked with industry partners and the DuraMAT data hub to enable private parties to share and aggregate PV production data anonymously, leveraging cloud-based data analysis infrastructure and publishing on US fleet-scale performance comprising over 7GW of operating systems. (https://www.nrel.gov/pv/fleet-performance-data-initiative.html). Through our industry collaborations we have engaged in NDA-covered data transfer with twelve PV fleet owners as of January 2022, with more agreements in negotiation. Our scalable cloud-based time series database contains over 30 billion rows (20TB) of PV time series data, representing over 1700 commercial and utility-scale systems, and over 7.2 GW of DC capacity (Fig 1). Initial field performance results have been distributed in several public reports. Because our fleet composition and data quality methods are continually improving, annual updates to these results are published to our PV Fleet webpage [ https://www.nrel.gov/pv/fleet-performance-data-initiative.html ] and DuraMAT data hub [DOI: 10.21948/1842958]. Another existing dissemination channel used for observed soiling losses is a map we maintain for soiling losses. Additional products developed include a report detailing fleet-wide performance index, availability, startup loss and snow loss factors, a detailed report on the 1603 grant dataset comprising over 100,000 PV systems with failure and performance details and a utility-scale report coauthored with LBNL on 31 GW of system performance.

14 SOLAR ENERGY↗

sdt (Solar Data Tools) [SWR-25-130]

Solar Data Tools (sdt) is an open-source Python library for analyzing PV power (and irradiance) time-series data. It was developed to enable analysis of unlabeled PV data, i.e. with no model, no meteorological data, and no performance index required, by taking a statistical signal processing approach in the algorithms used in the package’s main data processing pipeline. Solar Data Tools empowers PV system fleet owners or operators to analyze system performance a hundred times faster even when they only have access to the most basic data stream—power output of the system.

Meyers-Im, Bennet [National Laboratory of the Rock↗

Near-Optimal Performance of Stochastic Model Predictive Control

Here, this article presents a regret analysis for stochastic model predictive control (SMPC) in linear systems with quadratic performance index and additive and multiplicative uncertainties. Under a finite support assumption, the problem can be cast as a finite-dimensional quadratic program, but the problem becomes quickly intractable as the problem size grows exponentially in the horizon length. SMPC aims to compute approximate solutions by solving a sequence of problems with truncated prediction horizons and committing the solution in a receding-horizon fashion. Although this approach is widely used in practice, its performance relative to the optimal solution is not well understood. This article reports for the first time a rigorous near-optimal performance guarantee of SMPC: under stabilizability and detectability conditions, the regret of SMPC is exponentially small in the prediction horizon length, allowing SMPC to achieve near-optimal performance at a substantially reduced computational expense.

93E20, 93B45↗

Optimal Control Strategy With Efficiency and Reliability Improvement for Offshore DC Microgrids

Offshore microgrids, due to their remote location and lack of external energy support, face significant challenges in wide-range load operation and maintenance. Consequently, efficiency and reliability are critical concerns for converters in offshore dc microgrids. This article presents an optimal control strategy aimed at enhancing both efficiency and reliability. A normalized nonlinear relationship between power loss and thermal stress of a paralleled converter is first established. Based on this, a dual-objective optimization function with an active weight function as well as a system overall performance index is established. The active weight function dynamically adjusts the control priority based on converter efficiency and switching device thermal stress. Then, the optimal power-sharing strategy is derived by the Lagrange multiplier method with the proposed optimal function. Additionally, to accommodate a wide load range, an optimal selection strategy for operating converter combinations is proposed, requiring only low-bandwidth communication. Experiment verification is given to validate the effectiveness of the proposed control strategy. The experiment results demonstrate that the proposed control strategy can improve the overall performance of offshore microgrids by optimizing efficiency and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2020

This report presents an enhanced performance evaluation of emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2020 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2020. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • HPCS EDG FTS failure probability • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTS failure probability • EPS EDG FTLR failure probability • EPS EDG unavailability • EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2022

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2022 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2022. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: (1) HPCS EDG FTS failure probability, (2) EPS and HPCS EDG frequency of start demands (demands per reactor year), and (3) EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: (1) EPS EDG FTS failure probability, (2) EPS EDG FTLR failure probability, (3) EPS EDG unavailability, and (4) EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Automated detection of photovoltaic cleaning events: A performance comparison of techniques as applied to a broad set of labeled photovoltaic data sets

Extracting accurate soiling loss information from photovoltaic (PV) production data first requires segmenting the time series data per natural or manually occurring cleaning events. Maintenance logs are often incomplete, rain data are often unavailable, and the debate on rain thresholds for cleaning and dew or wind cleanings is still ongoing. The present work aims to overtake these issues by improving automated methods to detect these cleaning events and therefore improve extraction of soiling loss information. Time series power production data from 22 PV inverters were labeled for natural or manually occurring cleaning events. The data sets were carefully selected to include varying degrees of soiling, cleaning events, and noise. Several algorithms, including filtering logic and change point detection, were examined for efficacy at detecting the labeled cleanings. All the methods introduced except for changepoint detection showed significant improvement at detecting the labeled cleaning events per the mean F 1 score. Furthermore, the highest performing cleaning detection algorithm achieved an absolute increase in the mean F 1 score of 43% over the default version of the RdTools stochastic rate and recovery (SRR) algorithm. The highest performing algorithm included irradiance filtering and a cleaning detection threshold, adjusted based on the 40-day centered rolling median of the absolute day-to-day deviations in the daily performance index (PI). Furthermore, these improvements are promising as cleaning detection is an essential step in the automated analysis of PV soiling.

14 SOLAR ENERGY↗

Multi-Objective Boundary Analysis of Discrete and Integrated SiC FET Modular Non-inverting Buck and Boost Converters for Fuel Cell EVs

This paper presents a multi-objective analysis of discrete and integrated SiC FET-based non-inverting buck-boost converter modules for modular fuel cell electric vehicle (EV) systems. Two converter ratings, 60 kW and 90 kW, are evaluated for both implementations, scalable up to 420 kW and 450 kW, respectively. Performance is assessed across efficiency, volumetric and gravimetric power density, cost, thermal stress, and estimated lifetime, where lifetime is derived from SiC FET B10 power-cycling data and junction temperature variations at rated power. A normalized overall performance index combined with a Pareto-boundary framework is used to identify configurations that optimally balance competing objectives. Results show that most configurations lie on the Pareto front, providing balanced trade-offs, while certain high-power discrete (90 kW at 450 kW) and integrated (60 kW at 180−420 kW) configurations are dominated. In general, discrete modules are more favorable for lower-power modular systems due to higher power density and lower cost, whereas integrated modules become more advantageous at higher power levels due to improved thermal behavior and longer lifetime. These findings provide practical design guidance for scalable fuel cell converter architectures and highlight the importance of system-level trade-offs in modular power electronics design.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗