Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum sensing for fundamental physics efforts at SQMS

One of the areas of research of the Superconducting Quantum Systems and Materials (SQMS) center is the application of quantum sensing to fundamental physics searches, demonstrating that quantum sensors can greatly improve the sensitivity of experiments searching for Beyond the Standard Model (BSM) physics, or performing high-precision measurements. Theorists have developed many ideas for BSM physics that would result in interactions that can in principle be detected, but with signals small enough that they haven t been observed yet. In this field, the capability to lower the detector s thermal noise to few or dozens of mK, and to use QIS technologies such as Josephson Parametric Amplifiers and photon counters (in-situ or itinerant) enable us to reach unprecedented sensitivities and faster scan rates. Here is presented an overview of the quantum sensing efforts at SQMS [1], focusing on theoretical advancements and experimental searches for Dark Sector particles (as dark matter candidates and not), gravitational waves, and precision measurements. The experiments conducted, or under preparation, include axion dark matter (DM) [2, 3], dark photon DM searches [4,5], light-shining-through-wall experiments [6], cavity-based searches for high frequency gravitational waves [7], and measurements of the electron magnetic moment [8]. [1] Berlin, A., et al. "Searches for new particles, dark matter, and gravitational waves with SRF cavities." arXiv preprint arXiv:2203.12714 (2022). [2] Giaccone, B., et al. "Design of axion and axion dark matter searches based on ultra high Q SRF cavities." arXiv preprint arXiv:2207.11346 (2022). [3] Braggio, C., et al. "Quantum-enhanced sensing of axion dark matter with a transmon-based single microwave photon counter." arXiv preprint arXiv:2403.02321 (2024). [4] Fan, X., et al. "One-electron quantum cyclotron as a milli-eV dark-photon detector." Physical review letters 129.26 (2022): 261801. [5] Cervantes, R., et al. "Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities." Physical Review D 110.4 (2024): 043022. [6] Romanenko, A., et al. "Search for dark photons with superconducting radio frequency cavities." Physical review letters 130.26 (2023): 261801. [7] Berlin, A., et al. "Electromagnetic cavities as mechanical bars for gravitational waves." Physical Review D 108.8 (2023): 084058. [8] Fan, X., et al. "Measurement of the electron magnetic moment." Physical review letters 130.7 (2023): 071801.

Giaccone, Bianca↗

Quantum Sensing Experiments at SQMS

The Superconducting Quantum Materials and Systems (SQMS) Center, led by Fermi National Accelerator Laboratory, is one of five U.S. Department of Energy-funded research centers dedicated to advancing quantum computing and quantum sensing. SQMS leverages its expertise in superconducting radio-frequency (SRF) cavities and transmon qubits to develop sensitive quantum sensors to probe fundamental physics. This presentation will highlight the progress and innovations in SQMS’s quantum sensing thrust, with a particular focus on searches for particles beyond the Standard Model, dark matter candidates, and gravitational waves. Recent developments include the search for dark photon dark matter using transmon qubits and widely tunable superconducting cavities (4 GHz–7 GHz), a quantum-enhanced axion dark matter search employing an itinerant single microwave photon counter, and efforts to detect low-mass axions and high-frequency gravitational waves using multimode superconducting cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time reflection of light from a quantum perspective and vacuum entanglement

If a boundary between two static media is moving with a constant superluminal velocity, or there is a sudden change of the refractive index with time, this yields generation of entangled pairs of photons out of vacuum propagating in the opposite directions. Here we show that during this process, entanglement of Minkowski vacuum is transferred to the entanglement of the generated photon pairs. If initially an electromagnetic pulse is present in the medium the photon generation is stimulated into the pulse mode, and since photons are created as entangled pairs the counter-propagating photon partners produce a pulse moving in the opposite direction, which is known as time reflection. Thus, time reflection occurs due to stimulated generation of the entangled photon pairs out of entangled vacuum and no photons in the original pulse are in fact being reflected. This is different from the mechanism of light reflection from spatial inhomogeneities for which no photons are generated.

Optics↗

Circularly Polarized Attosecond Pulses Enabled by an Azimuthal Phase and Polarization Grating

High-harmonic generation (HHG) is an extreme nonlinear optical process that can map the properties of an infrared driving laser beam onto short wavelength attosecond pulse trains. However, current techniques for generating circularly polarized high harmonics for probing magnetic materials and chiral systems have limitations: two-color collinear counter-rotating driving lasers result in a low cutoff photon energy, while single-color non-collinear counter-rotating schemes suffer from low conversion efficiency. In this work, we generate circularly polarized attosecond pulse trains by using a structured laser driver which has a rotating polarization and phase grating along the azimuthal coordinate. Furthermore, our experimental and numerical results demonstrate the production of left and right circularly polarized harmonics, which naturally separate upon propagation. Our approach uses a single laser color in a collinear geometry, that can be scaled for high efficiency. Simulations show this scheme can extend into the soft x-ray region when driven by mid-infrared driving lasers, while preserving the same high phase-matching cutoff photon energy as for linearly-polarized high harmonics.

attosecond science↗

Emerging supersolidity in photonic-crystal polariton condensates

A supersolid is a counter-intuitive phase of matter in which its constituent particles are arranged into a crystalline structure, yet they are free to flow without friction. This requires the particles to share a global macroscopic phase while being able to reduce their total energy by spontaneous, spatial self-organization. The existence of the supersolid phase of matter was speculated more than 50 years ago1, 2, 3–4. However, only recently has there been convincing experimental evidence, mainly using ultracold atomic Bose–Einstein condensates (BECs) coupled to electromagnetic fields. There, various guises of the supersolid were created using atoms coupled to high-finesse cavities5,6, with large magnetic dipole moments7, 8, 9, 10, 11, 12–13, and spin–orbit-coupled, two-component systems showing stripe phases14, 15–16. Here we provide experimental evidence of a new implementation of the supersolid phase in a driven-dissipative, non-equilibrium context based on exciton–polaritons condensed in a topologically non-trivial, bound state in the continuum (BiC) with exceptionally low losses, realized in a photonic-crystal waveguide. We measure the density modulation of the polaritonic state indicating the breaking of translational symmetry with a precision of several parts in a thousand. Direct access to the phase of the wavefunction allows us to also measure the local coherence of the supersolid. We demonstrate the potential of our synthetic photonic material to host phonon dynamics and a multimode excitation spectrum.

Trypogeorgos, Dimitrios↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hard X-ray inverse Compton scattering at photon energy of 87.5 keV

Abstract Production of hard X-ray via inverse Compton scattering at photon energies below 100 keV range aimed at potential applications in medicine and material research is reported. Experiments have been performed at the Brookhaven National Laboratory, Accelerator Test Facility, employing the counter collision of a 70 MeV, 0.3 nC electron beam with a near infra-red Nd: YAG laser (1064 nm wavelength) pulse containing ~ 100 mJ in a single shot basis. The radiation distribution of the scattered photon beam is assessed to be sufficiently quasi monochromatic to produce clear contrast from the Au K - edge at 80.7 keV.

43 PARTICLE ACCELERATORS↗

Searches for Sub-GeV Dark Matter with NOvA and LDMX and Performance Studies of the Cosmic-Ray Veto for Mu2e

The constituents of dark matter are still unknown, and the viable possibilities span a very large mass range. Specific scenarios for the origin of dark matter sharpen the focus to within about an MeV to 100 TeV. Most of the stable constituents of known matter have masses in the lower range, and a thermal origin for dark matter works in a simple and predictive manner in this mass range as well. Non-gravitational couplings of dark matter to Standard Model particles would make it possible to produce dark matter at accelerators. Through 120 GeV proton-nucleus collisions, NOvA is effectively a beam dump experiment for producing and detecting dark matter. This thesis presents a search for dark matter – electron scattering in the NOvA near detector from sub-GeV dark matter produced at the target. A future search for sub-GeV dark matter with the Light Dark Matter eXperiment (LDMX) is discussed, along with a study of LDMX's expected sensitivity to visibly decaying dark photons. Additionally, performance studies of the Mu2e cosmic ray veto (CRV) are presented. A calibration procedure for the CRV counters is discussed, along with tests of the efficiency, position resolution, and light yield decline of the CRV counters.

Horoho, Tyler Gregory [Virginia U.] (ORCID:0000000↗

Measuring Neutron Polarisation in Deuteron Photo-disintegration with the CLAS Start Counter [Thesis]

Deuteron photo-disintegration (γd → γp) is a reaction that represents the simplest case in which nuclear and hadron physics models can be tested. Despite this, associated polarization analyses are limited in terms of angular coverage and energy ranges, especially in observables related to the recoil neutron. This is largely due to a lack in dedicated polarimetry equipment, and represents a roadblock in global progress to understand high-energy phenomena such as hexaquarks, and quark-gluon degrees of freedom. To address this problem, this PhD thesis pioneers a new methodology for the parasitic measurement of nucleon polarization using kinematic reconstruction of (spin-dependent) nucleon-nucleus scattering of reaction products, prior to their detection in large acceptance particle detector apparatus. Following this novel approach, which requires no dedicated polarimeter, a determination of the double polarization observable, $C^n_{x'}$, from deuteron photo-disintegration is presented, using Jefferson Lab’s CLAS detector. The analysis utilizes the (n,p) charge exchange reaction in CLAS’s "start counter" (plastic scintillator) to determine the final state neutron polarizations. The results present the first ever data for this observable above 0.7 GeV (photon beam energy) and significantly extend the angular range of the world data set. This new data is largely statistically consistent with the previous measurement of $C^n_{x'}$ by Bashkanov et al . in the overlapping energy range of 0.4-0.7 GeV. It is planned for the statistical accuracy of the presented result to be increased by the inclusion of additional data. The analysis herein serves as a key proof of concept for future applications, including a recommended similar analysis to be implemented with data from the more modern CLAS12 detector. This paves the way for a plethora of additional analyses using existing data sets that would provide crucial new constraints for hadron and nuclear physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

Two-photon Rydberg EIT resonances in non-collinear beam configurations

We study the modifications of Rydberg EIT resonances in non-collinear geometry in which the two required optical fields cross at a small non-zero angle. We observe a strong broadening and amplitude reduction even for small angles when compared to exact counter-propagating and co-propagating collinear geometries. We confirm that such EIT peak deterioration results from the additional Doppler broadening due to the transverse velocity distribution of atoms. The numerical simulation closely matches the experimental measurements. While a non-collinear geometry provides improved spatial resolution for Rydberg EIT electrometry, we conclude that the crossing angle must be small to maintain field sensitivity.

Su, Kevin↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗