Search NASA⌕ Search

SEARCH · Search NASA

Results for “plan view imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

When does atomic resolution plan view imaging of surfaces work?

We present that surface structures that are different from the corresponding bulk, reconstructions, are exceedingly difficult to characterize with most experimental methods. Scanning tunneling microscopy, the workhorse for imaging complex surface structures of metals and semiconductors, is not as effective for oxides and other insulating materials. This paper details the use of transmission electron microscopy plan view imaging in conjunction with image processing for solving complex surface structures. We address the issue of extracting the surface structure from a weak signal with a large bulk contribution. This method requires the sample to be thin enough for kinematical assumptions to be valid. The analysis was performed on two sets of data, c(6×2) on the (100) surface and (3×3) on the (111) surface of SrTiO 3 , and was unsuccessful in the latter due to the thickness of the sample and a lack of inversion symmetry. In conclusion, the limits and the functionality of this method are discussed.

36 MATERIALS SCIENCE↗

Summary of May 21st and 22nd Shear Campaign [Slides]

We have streaked imaging of both smooth and roughened foils in both Ti and Al at both early and late times. Further work will be needed to check if the signal is strong enough on all shots to extract reliable mix-widths. The initial test of the 3 slit streaked imaging setup was unsuccessful. Streaked images of a driven shots using the slit on the target resulted in low signal, while un-driven shots showed much higher signals. The working hypothesis is that the signal dropped due to slit closure on the target; the successful NIF setup used a much wider slit, on the order of 100 um instead of 20 um. We were able to get good streak data by switching back to a 20 um pinhole at the front of the SSCA and removing the slits from the targets. To obtain the best late-time streak data we had to overlap the two TIM4 BL groups (on the BL driver). We have sets of plan view radiographs for at least three different times for both smooth and roughened foils in both Ti and Al. There are visually identifiable difference between the plan view radiographs of the smooth and enhanced roughened foils. The enhanced roughening is apparent in the plan view images at early times and seems to persist as the dominant structure scale into late times. We have several streaked plan view images. Further analysis will be required to determine if this can be turned into a viable platform for turbulence studies. Signal strength on the Al streaked plan view looks promising.

Plasma Physics & Fusion Technology(70)↗

Mapping of Benthic Habitats at Marine Renewable Energy Sites Using Multibeam Echosounder and Sediment Profile Imaging Technologies

Objectives/Scope: The goal of this work was to develop a consistent and semi-automated seafloor survey method for generating high-resolution, benthic habitat maps for environmental assessments and monitoring of marine renewable energy sites. Sediment profile and plan view imaging (SPI/PV) technology was combined with multibeam bathymetry and acoustic backscatter methods to demonstrate a rapid, cost-effective benthic mapping protocol. A key technical innovation of this project was the development of an image processing platform that automatically measures key features from the images. Methods: Multibeam echosounder (MBES) acoustic and SPI/PV surveys were conducted at three coastal areas off the U.S. west coast, including the PacWave South energy test site off of Newport, Oregon. Point data on physical and biological sediment conditions obtained from the SPI/PV imagery were used to efficiently ground-truth the high-resolution MBES bathymetry and backscatter mosaics. The SPI camera is an optical corer that obtains an undisturbed 21 by 15 cm, high-resolution, cross-sectional image of the sediment–water interface and upper sediment column. The plan view camera attached to the SPI camera frame captures a downward looking view of the seabed immediately before the SPI image is obtained. As part of this project, we developed a computer vision image processing platform (iSPI) that uses deep convolutional neural networks and other approaches to automatically identify and measure key features in the images, such as grain size and surface relief. Results: Detailed benthic habitat maps were generated using this mapping approach for three different marine settings. The sites mapped included a silt-dominated embayment; a sloping, nearshore, transitional very fine to coarse sand bottom; and a medium, sand-dominated continental shelf marine energy test site. In each case, acoustic and imaging surveys were completed in less than week, and detailed benthic habitat maps were generated within 60 days. The results were placed within the Coastal and Marine Ecological Classification Standard (CMECS) habitat mapping framework, and various combinations of the bathymetry, backscatter, and SPI and PV data were used to generate CMECS component maps. Novel Information: This project developed and demonstrated a repeatable and cost-effective approach for efficiently mapping benthic habitat conditions over broad areas of the seafloor by combining state-of-the-art acoustic and imaging techniques. The primary survey tools used in this project have been used previously in both the offshore renewable (wind) and oil and gas sectors to map and monitor benthic environments. This project’s innovations include 1) the focused use of high-resolution SPI/PV imagery to ground-truth acoustic mosaics, and 2) the development of a computer automated image analysis processing tool that both streamlines and standardizes the generation of data from the imagery and makes the data extraction process more cost-effective and repeatable.

13 HYDRO ENERGY↗

A transmission electron microscopy study of dislocation propagation and filtering in highly mismatched GaSb/GaAs heteroepitaxy

Monolithic integration of lattice-mismatched semiconductor materials opens up access to a wide range of bandgaps and new device functionalities. However, it is inevitably accompanied by defect formation. A thorough analysis of how these defects propagate and interact with interfaces is critical to understanding their effects on device parameters. In this study, we present a comprehensive study of dislocation networks in the GaSb/GaAs heteroepitaxial system using transmission electron microscopy (TEM). Specifically, the sample analyzed is a GaSb film grown on GaAs using dislocation–reduction strategies such as interfacial misfit array formation and introduction of a dislocation filtering layer. Using various TEM techniques, it is shown that such an analysis can reveal important information on the dislocation behavior including filtering mechanism, types of dislocation reactions, and other interactions with interfaces. A novel method that enables plan-view imaging of deeply embedded interfaces using TEM and a demonstration of independent imaging of different dislocation types are also presented. While clearly effective in characterizing dislocation behavior in GaSb/GaAs, we believe that the methods outlined in this article can be extended to study other heteroepitaxial material systems.

36 MATERIALS SCIENCE↗

A Streamlined and Standardized Benthic Habitat Mapping Approach for Marine and Hydrokinetic Site Environmental Assessments

We have combined two seafloor mapping techniques to efficiently map benthic habitat conditions. Multibeam echosounder (MBES) surveys provide detailed bathymetry and backscatter mosaics. Sediment profile and plan view imaging (SPI/PV) rapidly provides dense ground truth data on seabed physical and biological features. A key innovation of this project has been the development of a computer-assisted image processing system that standardizes the SPI data generation process. A unique combination of machine- and deep-learning techniques for grain-size classification, sediment–water interface delineation, and object detection (e.g., infauna and feeding voids) is described. An automated SPI image analysis system provides a standardized and cost-effective approach for image processing. Combining MBES with SPI/PV camera technology provides a first tier approach to rapidly documenting seabed physical and biological conditions in high resolution at MHK sites. When coupled with computer automated data extraction from the imagery, this approach provides a standardized and cost-effective method to establish and monitor benthic habitat conditions over time.

Benthic Habitat Maping, Sediment-Profile Imaging, ↗

An Analysis of Image Segmentation Time in Beam’s-Eye-View Treatment Planning

In this work we tabulate and histogram the image segmentation time for beam’s eye view (BEV) treatment planning in our center. The average time needed to generate contours on CT images delineating normal structures and treatment target volumes is calculated using a data base containing over 500 patients’ BEV plans. The average number of contours and total image segmentation time needed for BEV plans in three common treatment sites, namely, head/neck, lung/chest, and prostate, were estimated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lattice and grain-boundary diffusions of boron atoms in BaSi{sub 2} epitaxial films on Si(111)

A 180-nm-thick boron (B) layer was deposited on a 300-nm-thick a-axis-oriented BaSi{sub 2} epitaxial film grown by molecular beam epitaxy on Si(111) and was annealed at different temperatures in ultrahigh vacuum. The depth profiles of B were investigated using secondary ion mass spectrometry (SIMS) with O{sup 2+}, and the diffusion coefficients of B were evaluated. The B profiles were reproduced well by taking both the lattice and the grain boundary (GB) diffusions into consideration. The cross-sectional transmission electron microscopy (TEM) image revealed that the GBs of the BaSi{sub 2} film were very sharp and normal to the sample surface. The plan-view TEM image exhibited that the grain size of the BaSi{sub 2} film was approximately 0.6 {mu}m. The temperature dependence of lattice and GB diffusion coefficients was derived from the SIMS profiles, and their activation energies were found to be 4.6 eV and 4.4 eV, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Benthic Habitat Monitoring Approach for Marine and Hydrokinetic Sites (Final Technical Report)

This final technical report summarizes the work completed as part of the Standardized and Cost-Effective Benthic Habitat Mapping and Monitoring Tools for MHK Environmental Assessments project funded by U.S. Department of Energy (DOE) under contract DE-EE007826 to Integral Consulting Inc. The overall goal of this project was to demonstrate a consistent, repeatable, and semi-automated seafloor and sediment mapping approach for rapidly characterizing benthic physical and biological/habitat conditions to support marine environmental assessments for marine and hydrokinetic energy sites. The approach evaluated combines sediment profile imaging and plan view (SPI/PV) technology with multibeam echosounder surveys as an effective and low-cost benthic habitat mapping protocol. A key innovation was the development of a semi-automated computer vision system that standardizes the extraction of data from the SPI/PV images. Other elements of the project were SPI camera hardware modifications, including the design and fabrication of a prototype “power” SPI camera to improve camera prism penetration in firm substrates, and outreach to agency regulators and other stakeholders on this habitat mapping approach. This technical report consists of five main subsections that summarize: 1) the benthic mapping approach; 2) benthic mapping results from the three areas’ surveys; 3) the development and performance of the image processing algorithms; 4) SPI camera hardware improvements and prototype testing; and 5) the regulatory outreach efforts.

16 TIDAL AND WAVE POWER↗

Excitation-Dependent Recombination and Diffusion Near an Isolated Dislocation in GaAs

In low-magnification, plan-view photoluminescence images of a nominally lattice-matched, undoped GaAs/GaInP heterostructure, we observe a random distribution of isolated dark spots. We attribute the dark spots to crystal dislocations, where nonradiative recombination is augmented by transitions utilizing defect-related energy levels between the conduction and valence bands. We note that, when the laser excitation intensity is reduced, the darkened regions expand. At lower excitation, the density of photogenerated electrons and holes is reduced, and they are more likely to reach the defective region before encountering a partner for radiative recombination. When we model the behavior with a simulation that allows for Laplacian diffusion and defect-related recombination only through mid-bandgap energy levels, we do not obtain good agreement between experimental and simulated images. But if we allow for an arbitrary distribution of defect levels, such that the occupation of the levels and bands can change independently, we have more flexibility for fitting the density-dependent recombination rates. The more sophisticated model produces results that are more consistent with experimental images.

14 SOLAR ENERGY↗

Standardized and Cost-Effective Benthic Habitat Mapping Tools for Marine and Hydrokinetic Site Environmental Assessments

A variety of techniques have been used for baseline benthic habitat characterization and monitoring at marine and hydrokinetic (MHK) sites. A lack of standardization has led to expensive efforts that can be confusing for regulators and stakeholders evaluating these sites. Benthic habitat maps have traditionally been developed from a suite of geophysical data, including ultibeam echosounder (MBES) bathymetry and backscatter, side scan sonar, imagery from deployed camera systems, and/or sediment sample chemical and biological data. Integral is developing a computer vision (CV) system for automating the measurement of key physical and biological features in sediment profile image (SPI) and seafloor plan view (PV) imagery so that image-derived data can be efficiently integrated with other data sets to create standardized benthic habitat maps at MHK facilities.

16 TIDAL AND WAVE POWER↗

Nonuniform Charge Collection in SiOx-Based Passivated-Contact Silicon Solar Cells

In this contribution, we report on the charge-collection characteristics of silicon photovoltaic devices using passivated contacts based on the c-Si/SiO x /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiO x layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The apexes of the pyramids exhibit reduced EBIC signal whereas the valleys between adjacent pyramids show the strongest collection. Our results indicate that charge collection in c-Si/SiO x /poly-Si structures can be influenced by both the properties of the SiO x layer and surface texture.

14 SOLAR ENERGY↗

Revealing the Nano-Scale Structure and Properties of Pinholes in SiOx Layers for POLO Contacts

In this contribution, we report on the charge collection characteristics of silicon photovoltaic devices with passivated contacts based on the c-Si/SiOx /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiOx layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The locations where we observe preferential collection of excess carriers is very sensitive to the processing conditions used to grow and breakup the SiOx passivation layer. In some cases the apexes of the pyramids exhibit reduced EBIC signal as the valleys between adjacent pyramids show the strongest collection. Other conditions yield enhanced charge collection at well defined spots on pyramid faces with no observable collection in the valleys.

EBIC↗

MSLICE Science Activity Planner for the Mars Science Laboratory Mission

MSLICE (Mars Science Laboratory InterfaCE) is the tool used by scientists and engineers on the Mars Science Laboratory rover mission to visualize the data returned by the rover and collaboratively plan its activities. It enables users to efficiently and effectively search all mission data to find applicable products (e.g., images, targets, activity plans, sequences, etc.), view and plan the traverse of the rover in HiRISE (High Resolution Imaging Science Experiment) images, visualize data acquired by the rover, and develop, model, and validate the activities the rover will perform. MSLICE enables users to securely contribute to the mission s activity planning process from their home institutions using off-the-shelf laptop computers. This software has made use of several plug-ins (software components) developed for previous missions [e.g., Mars Exploration Rover (MER), Phoenix Mars Lander (PHX)] and other technology tasks. It has a simple, intuitive, and powerful search capability. For any given mission, there is a huge amount of data and associated metadata that is generated. To help users sort through this information, MSLICE s search interface is provided in a similar fashion as major Internet search engines. With regard to the HiRISE visualization of the rover s traverse, this view is a map of the mission that allows scientists to easily gauge where the rover has been and where it is likely to go. The map also provides the ability to correct or adjust the known position of the rover through the overlaying of images acquired from the rover on top of the HiRISE image. A user can then correct the rover s position by collocating the visible features in the overlays with the same features in the underlying HiRISE image. MSLICE users can also rapidly search all mission data for images that contain a point specified by the user in another image or panoramic mosaic. MSLICE allows the creation of targets, which provides a way for scientists to collaboratively name features on the surface of Mars. These targets can also be used to convey instrument-pointing information to the activity plan. The software allows users to develop a plan of what they would like the rover to accomplish for a given time period. When developing the plan, the user can input constraints between activities or groups of activities. MSLICE will enforce said constraints and ensure that all mission flight rules are satisfied.

Powell, Mark W.↗

Characterization of encapsulated quantum dots via electron channeling contrast imaging

A method for characterization of encapsulated epitaxial quantum dots (QD) in plan-view geometry using electron channeling contrast imaging (ECCI) is presented. The efficacy of the method, which requires minimal sample preparation, is demonstrated with proof-of-concept data from encapsulated (sub-surface) epitaxial InAs QDs within a GaAs matrix. Imaging of the QDs under multiple diffraction conditions is presented, establishing that ECCI can provide effectively identical visualization capabilities as conventional two-beam transmission electron microscopy. This method facilitates rapid, non-destructive characterization of sub-surface QDs giving immediate access to valuable nanostructural information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

(Oxy)hydroxides Formed on Aluminum Fuel Materials After Irradiation and Long-Term Wet Storage - 20354

The aluminum cladding of research-reactor fuel experiences general corrosion when in contact with water during in-reactor service and post-discharge wet storage, resulting in the formation of adherent aluminum (oxy)hydroxide films. These (oxy)hydroxides contain chemically-bound water that poses challenges for extended dry storage due to the risk of thermal or radiolytic decomposition releasing free water and/or hydrogen and oxygen gases. This study describes characterization of the (oxy)hydroxides present on several aluminum materials used in reactor operation and subsequently stored wet in the L-Basin storage facility at the Savannah River Site (SRS) for an extended period. Characterization data providing insight into the loading, composition, and morphology of (oxy)hydroxides to be expected on service-exposed aluminum cladding provides valuable benchmarks for designing adequate drying and dry-storage approaches. This work is part of a broader investigation to address knowledge gaps and technical data needs for dry storage of aluminum-clad spent nuclear fuel (ASNF), which included in-lab growth of (oxy)hydroxide films on aluminum alloy substrates to investigate formation behavior, investigation of drying methods to remove existing (oxy)hydroxides from ASNF cladding, and measurement of radiolytic yield of hydrogen from (oxy)hydroxide powders and films. In this study, (oxy)hydroxide films were characterized for three aluminum-alloy materials used in reactors and subsequently stored wet for up to approximately 40 years in L-Basin at SRS: one cropping from a Missouri University Research Reactor (MURR) fuel element (Al-6061 alloy), one cropping from a Universal Sleeve Housing (USH) (Al-6063 alloy), and one Mark-16B fuel assembly (either Al-6061 or Al- 6063). The USH and Mark-16B were used in SRS production reactors. Characterization of the as-received (oxy)hydroxides included scanning electron microscopy (SEM) in both plan-view and cross-section to characterize the (oxy)hydroxide layer's morphology, thickness, and structure. X-ray diffraction (XRD) was used to identify the chemical composition and distinguish between the various aluminum (oxy)hydroxides known to form under reactor and storage conditions. XRD analysis revealed both bayerite (Al(OH)3) and boehmite (AlOOH) on the surface of the MURR and USH samples, as well as bayerite, boehmite, and gibbsite (another Al(OH)3 polymorph) on the surface of the Mark-16B sample. The aluminum trihydroxides, bayerite and gibbsite, are typically associated with corrosion in low-temperature (<80 deg. C) water, while boehmite is expected to form at higher water temperature (>80 deg. C). The presence of bayerite on the USH, which is believed to have operated close to 90 deg. C, suggests that boehmite formed during in-reactor exposure was not protective against further hydroxide growth in low-temperature wet storage. Cross-section scanning electron microscopy (SEM) showed total (oxy)hydroxide layer thicknesses of ∼5- 10 μm for the MURR and ∼5-15 μm for the Mark-16B. The thickness of the USH's (oxy)hydroxide layer was indiscernible by the current mounting and imaging method, despite plan-view SEM and XRD confirming the presence of an (oxy)hydroxide layer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Registration of clinical volumes to beams-eye-view images for real-time tracking

Purpose: The authors combine the registration of 2D beam’s eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). Methods: During treatment of lung SBRT cases, BEV images were continuously acquired with an electronic portal imaging device (EPID) operating in cine mode. For absolute registration of physician-defined volumes, an intensity based 2D/3D registration to the planning CT was performed using the end-of-exhale (EoE) phase of the four dimensional computed tomography (4DCT). The volume was converted from Hounsfield units into electron density by a calibration curve and digitally reconstructed radiographs (DRRs) were generated for each beam geometry. Using normalized cross correlation between the DRR and an EoE BEV image, the best in-plane rigid transformation was found. The transformation was applied to physician-defined contours in the planning CT, mapping them into the EPID image domain. A robust multiregion method of relative markerless lung tumor tracking quantified deviations from the EoE position. Results: The success of 2D/3D registration was demonstrated at the EoE breathing phase. By registering at this phase and then employing a separate technique for relative tracking, the authors are able to successfully track target volumes in the BEV images throughout the entire treatment delivery. Conclusions: Through the combination of EPID/4DCT registration and relative tracking, a necessary step toward the clinical implementation of BEV tracking has been completed. The knowledge of tumor volumes relative to the treatment field is important for future applications like real-time motion management, adaptive radiotherapy, and delivered dose calculations.

60 APPLIED LIFE SCIENCES↗

Characterization and Electrochemical Analysis of Acidic Condensate-Induced Corrosion on Aluminized Coating on Steel in Residential Heaters

Condensing furnace residential heaters are starting to replace outdated and less efficient non-condensing units in homes across the US. However, the burning of natural gas in these new units produces acidic gases, which can form acid droplets (H 2 SO 4 , HNO 3 , H 2 CO 3 , etc.) that are corrosive to low-grade heat exchanger metallic materials. Type-1 aluminized steel has been used in industrial applications, such as marine, heating, and automobile parts, due to its resistance to oxidation at elevated temperature. Many components of the condensing furnaces, including heat exchangers, are made from type-1 aluminized steel. We investigated the interaction of type-1 aluminized steel substrates with two acidic condensate liquids by 500 h corrosion exposures as well as short-term electrochemical impedance measurements. SEM plan and cross-sectional view images revealed damage to the Al-Si rich layer and exposure of the steel substrate. The non-uniform damage in the Al-Si rich layer was likely attributed to a pitting corrosion mechanism and induced by high acidity of the condensate liquid. Electrochemical impedance measurements in an acidic condensate revealed lower corrosion resistance of the aluminized steel surface with a weld line, identifying welded sections as preferential corrosion initiation sites.

36 MATERIALS SCIENCE↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗