Search NASA⌕ Search

SEARCH · Search NASA

Results for “product sterilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Comparative Metagenomic Analysis of Specified Microorganisms in Groundwater for Non-Sterilized Pharmaceutical Products

In pharmaceutical manufacturing, ensuring product safety involves the detection and identification of microorganisms with human pathogenic potential, including Burkholderia cepacia complex (BCC), Escherichia coli, Pseudomonas aeruginosa, Salmonella enterica, Staphylococcus aureus, Clostridium sporogenes, Candida albicans, and Mycoplasma spp., some of which may be missed or not identified by traditional culture-dependent methods. In this study, we employed a metagenomic approach to detect these taxa, avoiding the limitations of conventional cultivation methods. We assessed the groundwater microbiome’s taxonomic and functional features from samples collected at two locations in the spring and summer. All datasets comprised 436–557 genera with Proteobacteria, Bacteroidota, Firmicutes, Actinobacteria, and Cyanobacteria accounting for > 95% of microbial DNA sequences. The aforementioned species constituted less than 18.3% of relative abundance. Escherichia and Salmonella were mainly detected in Hot Springs, relative to Jefferson, while Clostridium and Pseudomonas were mainly found in Jefferson relative to Hot Springs. Multidrug resistance efflux pumps and BlaR1 family regulatory sensor-transducer disambiguation dominated in Hot Springs and in Jefferson. These initial results provide insight into the detection of specified microorganisms and could constitute a framework for the establishment of comprehensive metagenomic analysis for the microbiological evaluation of pharmaceutical-grade water and other non-sterile pharmaceutical products, ensuring public safety.

59 BASIC BIOLOGICAL SCIENCES↗

Cosmic structure strikes back: The elimination of vector-mediated nonstandard interaction models as a mechanism for sterile neutrino dark matter production

We revisit sterile neutrino production enabled by nonstandard interactions (NSIs) among active neutrinos mediated by new bosons. We focus on vector mediators, including neutrinophilic, gauged 𝐿 𝜇 −𝐿 𝜏 , and 𝐵−𝐿 realizations, that modify in-medium dispersion and scattering, thereby altering the active-sterile conversion history. Building on a novel production framework with NSI thermal potentials and collision integrals, we compute nonthermal phase-space distributions across sterile neutrino mixing and NSI parameters and map each point to an equivalent thermal warm dark matter particle mass 𝑚 th via linear theory transfer function fitting with the cosmological structure formation Boltzmann solver. This enables a direct reinterpretation of state-of-the-art structure formation limits from Milky Way satellites, strong lensing, and the Lyman-𝛼 forest. These limits, in conjunction with x-ray decay searches, as well as results from a wide variety of particle physics experiments allow for a more complete examination of these models. We find that these vector-mediated models are ruled out when the full combination of current constraints, listed above, are taken into account. NSI scalar-mediated models and models with low reheating temperatures remain viable.

cosmology↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PUFFIn – A user friendly fast interface for calculating and visualizing the dose distribution in materials

This article describes a new graphical user interface that uses the PENELOPE Monte Carlo code to calculate dose distributions in materials. It is named PUFFIn, for the Penelope User-Friendly Fast Interface and was developed as an educational and scoping analysis tool for non-experts in radiation modeling. PUFFIn enables the user to visualize and compare the dose distributions in objects (e.g., sterilized healthcare products) irradiated with cobalt-60 gamma-rays, electron beam (E-beam) or X-rays. From such comparisons, the user can determine the most efficient product and/or packaging designs for any given radiation field – whether for conceptual or existing products and packaging. PUFFIn is distributed in a complete, self-contained package of software, including the PENELOPE radiation transport code, a standard graphics package, and a set of simple exercises. The package is available to any user at no cost and requires a minimal amount of training compared to other similar software. PUFFIn's capabilities are described, as well as validation measurements performed at Texas A&M University E-beam facility and the Aerial E-beam Facility in France.

97 MATHEMATICS AND COMPUTING↗

Light and Electron Emission as Breakdown Probes: Synergistic DC and RF Study

The project was motivated by a particular and critical need in accelerator R&D to understand vacuum breakdown and arc as it would allow for developing high gradient machines. Accelerator systems operated at high gradients are less costly and more compact. This, in turn, would enable advanced and cost-effective accelerators for future colliders. Universities and medical centers would be able to build compact accelerator machines for basic X-ray and microscopy sciences, therapy, isotope production, sterilization etc.

43 PARTICLE ACCELERATORS↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of RF high power sources for 1MW – range, 10 MeV CW industrial accelerator.

Cobalt-60 is the dominant source of ionizing radiation for sterilizing products in the $200B/year medical device industry. Security and accessibility concerns around this radioactive material - sourced from countries including Russia and China - present national security and economic risks. There is a continued national urgency to replace such high-risk sources with low-risk alternatives such as electron or x-ray beams driven by accelerators. While e-beam sources have been in use for many years, they still represent a small portion of the market. X-ray sources are becoming economical alternatives. Meeting the processing capacity required to replace Co-60 requires a step-change in the capability, efficiency, and overall operating cost of electron accelerators to make adoption feasible. The radiofrequency (RF) power that drives accelerating cavities represents significant capital and operating costs for these accelerators. For accelerator-based systems to be a viable alternative for these applications, RF systems must be economical to manufacture, deploy, and operate.

43 PARTICLE ACCELERATORS↗

Primordial black hole sterile neutrinogenesis: sterile neutrino dark matter production independent of couplings

Abstract Sterile neutrinos (ν s s) are well-motivated and actively searched for hypothetical neutral particles that would mix with the Standard Model active neutrinos. They are considered prime warm dark matter (DM) candidates, typically when their mass is in the keV range, although they can also be hot or cold DM components. We discuss in detail the characteristics and phenomenology ofν s s that minimally couple only to active neutrinos and are produced in the evaporation of early Universe primordial black holes (PBHs), a process we called “PBH sterile neutrinogenesis”. Contrary to the previously studiedν s production mechanisms, this novel mechanism does not depend on the active-sterile mixing. The resultingν s s have a distinctive spectrum and are produced with larger energies than in typical scenarios. This characteristic enablesν s s to be WDM in the unusual 0.3 MeV to 0.3 TeV mass range, if PBHs do not matter-dominate the Universe before evaporating. When PBHs matter-dominate before evaporating, the possible coincidence of induced gravitational waves associated with PBH evaporation and astrophysical X-ray observations fromν s decays constitutes a distinct signature of our scenario.

Astronomy & Astrophysics↗

Probing the sterile neutrino dipole portal with SN1987A and low-energy supernovae

Beyond the Standard Model electromagnetic properties of neutrinos may lead to copious production of sterile neutrinos in the hot and dense core of a core-collapse supernova. In this work, we focus on the active-sterile transition magnetic moment portal for heavy sterile neutrinos. Firstly, we revisit the SN1987A cooling bounds for dipole portal using the integrated luminosity method, which yields more reliable results (especially in the trapping regime) compared to the previously explored via emissivity loss, also known as the Raffelt criterion. Secondly, we obtain strong bounds on the dipole coupling strength reaching as low as 10 − 11 GeV − 1 from energy deposition, i.e., constrained from the observation of explosion energies of underluminous Type IIP supernovae. In addition, we find that sterile neutrino production from Primakoff upscattering off of a proton dominates over scattering off of an electron for low sterile neutrino masses. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Propidium Monoazide (PMAxx)-Recombinase Polymerase Amplification Exo (RPA Exo) Assay for Rapid Detection of Burkholderia cepacia Complex in Chlorhexidine Gluconate (CHX) and Benzalkonium Chloride (BZK) Solutions

Both sterile and non-sterile pharmaceutical products, which include antiseptics, have been recalled due to Burkholderia cepacia complex (BCC) contamination. Therefore, minimizing the frequency of outbreaks may be conducive to the development of a quick and sensitive approach that can distinguish between live and dead loads of BCC. We have assessed an exo probe-based recombinase polymerase amplification (RPA) with 10 µM propidium monoazide (PMAxx) for selective detection of live/dead BCC cells in various concentrations of antiseptics (i.e., chlorhexidine gluconate (CHX) and benzalkonium chloride (BZK) solutions) after 24 h. The optimized assay conducted using a set of primer–probes targeting gbpT was performed at 40 °C for 20 min and shows a detection limit of 10 pg/µL of genomic DNA from B. cenocepacia J2315, equivalent to 10 4 colony-forming units (CFU/mL). The specificity of a newly designed primer and probe was 80% (20 negatives out of 25). The readings for total cells (i.e., without PMAxx) from 200 µg/mL CHX using PMAxx-RPA exo assay was 310 relative fluorescence units (RFU), compared to 129 RFU with PMAxx (i.e., live cells). Furthermore, in 50–500 µg/mL BZK-treated cells, a difference in the detection rate was observed between the PMAxx-RPA exo assay in live cells (130.4–459.3 RFU) and total cells (207.82–684.5 RFU). This study shows that the PMAxx-RPA exo assay appears to be a valid tool for the simple, rapid and presumptive detection of live BCC cells in antiseptics, thereby ensuring the quality and safety of pharmaceutical products.

59 BASIC BIOLOGICAL SCIENCES↗

Leptonic anomalous magnetic moments in ν SMEFT

We investigate contributions to the anomalous magnetic moments of charged leptons in the neutrino-extended Standard Model Effective Field Theory (νSMEFT). We discuss how νSMEFT operators can contribute to a lepton’s magnetic moment at one- and two-loop order. We show that only one operator can account for existing electronic and muonic discrepancies, assuming new physics appears above 1 TeV. In particular, we find that a right-handed charged current in combination with minimal sterile-active mixing can explain the discrepancy for sterile neutrino masses of $\mathcal{O}$(100) GeV while avoiding direct and indirect constraints. We discuss how searches for sterile neutrino production at the (HL-)LHC, measurements of h → μ + μ - and searches for h → e + e - , neutrinoless double beta decay experiments, and improved unitarity tests of the CKM matrix can further probe the relevant parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced muonization by active-sterile neutrino mixing in protoneutron stars

We study ν μ − ν s and ν ¯ μ − ν ¯ s mixing in the protoneutron star (PNS) created in a core-collapse supernova (CCSN). We point out the importance of the feedback on the general composition of the PNS in addition to the obvious feedback on the ν μ lepton number. We show that for our adopted mixing parameters δ m 2 ∼ 10 2 keV 2 and sin 2 2 θ consistent with the current constraints, sterile neutrino production is dominated by the Mikheyev–Smirnov–Wolfenstein conversion of ν ¯ μ into ν ¯ s and that the subsequent escape of ν ¯ s increases the ν μ lepton number, which in turn enhances muonization of the PNS primarily through ν μ + n → p + μ − . While these results are qualitatively robust, their quantitative effects on the dynamics and active neutrino emission of core-collapse supernovae should be evaluated by including ν μ − ν s and ν ¯ μ − ν ¯ s mixing in the simulations. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Elucidating the mechanisms of enhanced lignin bioconversion by an alkali sterilization strategy

Biological lignin valorization represents an emerging green approach to upgrade lignin for sustainable and economic biorefineries. However, lignin generally exhibits poor water solubility and inhomogeneous distribution in an aqueous medium, significantly limiting its bioconversion efficiency. Herein, we develop a novel alkali sterilization strategy to effectively enhance the dispersion and fermentation performance of lignin substrates. The colloidal particle size and molecular structure variations of lignin during the sterilization were thoroughly investigated to reveal the mechanisms of enhanced fermentation performance. Results showed that alkali sterilization achieved a completely aseptic effect when mixing lignin medium at an initial pH of 12.7 for 24 h. Dynamic light scattering (DLS) analysis demonstrated that the hydrodynamic volume of colloidal lignin particles decreased by 96.3% by alkali sterilization compared with the conventional thermal sterilization. Moreover, lignin characterizations by nuclear magnetic resonance (NMR) spectroscopy and gel permeation chromatography (GPC) suggested that alkali sterilization modified the lignin molecular structure by generating 50% more hydrophilic carboxyl groups, reducing the weight-average molecular weight (M w ) by 23.0%, and narrowing the molar-mass dispersity (D M ) by 23.8%. The generation of lignin substrates with more uniform distribution and lower molecular weight improved Rhodococcus opacus PD630 cell growth and metabolism. Microbial cell amount, lignin degradation, and lipid production in alkali sterilized medium increased by 309%, 30.3%, and 48.3%, respectively, compared to those in thermally sterilized medium. These results clearly demonstrated that alkali sterilization dramatically improved the lignin bioconversion performance. Furthermore, this work presents a facile and effective sterilization strategy to overcome inhomogeneous lignin distribution in aqueous fermentation media, showing great potentials as a platform technique for promoting biological lignin valorization.

59 BASIC BIOLOGICAL SCIENCES↗

Cosmological dependence of sterile neutrino dark matter with self-interacting neutrinos

Unexplored interactions of neutrinos could be the key to understanding the nature of the dark matter (DM). In particular, active neutrinos with new self-interactions can produce keV-mass sterile neutrinos that account for the whole of the DM through the Dodelson-Widrow mechanism for a large range of active-sterile mixing values. This production typically occurs before Big-Bang Nucleosynthesis (BBN) in a yet uncharted era of the Universe. We assess how the mixing range for keV-mass sterile neutrino DM is affected by the uncertainty in the early Universe pre-BBN cosmology. This is particularly relevant for identifying the viable parameter space of sterile neutrino searches allowed by all astrophysical limits, as well as for cosmology, since the detection of a sterile neutrino could constitute the first observation of a particle providing information about the pre-BBN epoch. Here, we find that the combined uncertainties in the early Universe cosmology and neutrino interactions significantly expand the allowed parameter space for sterile neutrinos that can constitute the whole of the DM.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Supplementing Gamma Sterilization with X-Ray and E-Beam Technologies: An International Industry and Academia Collaboration

Ionizing-technology–based industries are growing rapidly around the world. The expansion is driven mostly by the technology’s myriad applications, including polymer crosslinking, medical device sterilization, food pasteurization, and phytosanitary treatment. Ionization also is used in the manufacture of some healthcare products such as medical devices and biopharmaceuticals. Industrial sterilization methods render single-use products and manufacturing components safe and ready for their intended use. ISO11137-1 describes the validation and routine control of a sterilization process for medical devices and mentions the three types of radiation considered under this scope: gamma, X-ray, and electron beam (e-beam)

gamma sterilization, electron beam sterilization, ↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

A scalable and autoclavable oxygen nanosensor platform for metabolic monitoring of Saccharomyces cerevisiae in a bioreactor and other in situ systems

Polymer-encapsulated dye nanoparticle sensors are a valuable approach to achieving in situ analyte measurements with luminescence; however, typical emulsion-based nanosensors are poorly suited for large-scale biological samples due to limitations of synthesis scalability and stability. Branched polyethylenimine (PEI) is a versatile polymer scaffold ideal for constructing nanoparticles with various covalently conjugated moieties due to their high density of reactive primary amines, high water solubility, and biological stability. In this work, we used branched polyethylenimine as a scaffold-based approach for making a stable and scalable ratiometric oxygen sensor. Pt (II) tetracarboxyporphine was used as an oxygen-sensing dye and coumarin 343 as a reference dye, all covalently linked to the PEI scaffold producing a product that could withstand sterilization procedures and easily be scaled. To minimize toxicity from the PEI scaffold, we conjugated it with 2000 MW PEG. The applicability of the sensors was demonstrated in a 200 mL Saccharomyces cerevisiae yeast culture, using orthogonal luminescent and electrochemical oxygen measurements to validate sensor response and measure the metabolic activity of the yeast in our culture. Further, this approach was able to match the sensitivity of our electrochemical measurements while improving upon drawbacks of other luminescent methods of oxygen detection, demonstrating effective monitoring for at least 20 h. Our scaffold-based approach is a modular and easily translatable technology that could be useful in various biotechnological applications.

59 BASIC BIOLOGICAL SCIENCES↗