Cellular response to high pulse repetition rate nanosecond pulses varies with fluorescent marker identity

Nanosecond electric pulses (nsEP's) are a well-studied phenomena in biophysics that cause substantial alterations to cellular membrane dynamics, internal biochemistry, and cytoskeletal structure, and induce apoptotic and necrotic cell death. While several studies have attempted to measure the effects of multiple nanosecond pulses, the effect of pulse repetition rate (PRR) has received little attention, especially at frequencies greater than 100 Hz. In this study, uptake of Propidium Iodide, FM 1–43, and YO-PRO-1 fluorescent dyes in CHO-K1 cells was monitored across a wide range of PRRs (5 Hz–500 KHz) using a laser-scanning confocal microscope in order to better understand how high frequency repetition rates impact induced biophysical changes. We show that frequency trends depend on the identity of the dye under study, which could implicate transmembrane protein channels in the uptake response due to their chemical selectivity. Finally, YO-PRO-1 fluorescence was monitored in the presence of Gadolinium (Gd{sup 3+}), Ruthenium Red, and in calcium-free solution to elucidate a mechanism for its unique frequency trend. - Highlights: • Pulse repetition rate (PRR) is understudied in nanosecond electric pulsing. • 200 V pulses were applied to CHO-K1 cells from 5 Hz to 500 KHz. • Pulsing was repeated using a variety of fluorophores and imaging conditions. • The response is highly dependent on the fluorophore and the imaging conditions. • This may implicate protein channels in the nanoporation response.

60 APPLIED LIFE SCIENCES↗

Generation and Study of Am(IV) by Temperature-Controlled Electron Pulse Radiolysis

Used nuclear fuel (UNF) separation techniques that strive to separate radiotoxic americium (Am) from trivalent lanthanide fission products through oxidation state control have increased research efforts surrounding Am(V) and Am(VI). However, equivalent knowledge of the tetravalent state, Am(IV), has remained elusive, particularly in conditions more representative of UNF reprocessing, i.e., in concentrated nitric acid (HNO3). With this in mind, we have used electron pulse radiolysis to study the radiation-induced redox reaction of Am(III) with the oxidizing nitrate radical (NO3?) in 6 M HNO3: Am(III) + NO3? ? Am(IV) + NO3? . These experiments enabled us to observe the growth and decay of Am(IV) in a concentrated acidic solution for the first time. The transient Am(IV) species was found to have a lifetime of ~16 µs?sufficiently long-lived to play a critical mechanistic role in UNF reprocessing systems. Additionally, we performed the first-ever temperature-dependent kinetics study of an actinide element, elucidating unprecedented Arrhenius and Eyring activation parameters for the reaction of Am(III) with NO3?. This new knowledge provides much-needed molecular-level insights into the radiation-induced behavior of Am.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MICROCALORIMETER SPECTROSCOPY AT HIGH PULSE RATES: A MULTI-PULSE FITTING TECHNIQUE

Transition Edge Sensor microcalorimeters can measure X-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future X-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current “optimal filtering” approaches to achieve the best possible energy resolution work only for photons that are well isolated in time, a requirement which is in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render this procedure computationally viable even for very long data records. The technique is employed to analyze X-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts s{sup −1} in microcalorimeters having exponential signal decay times of approximately 1.2 ms.

79 ASTRONOMY AND ASTROPHYSICS↗

Reliable Determination of Pulses and Pulse-Shape Instability in Ultrashort Laser Pulse Trains Using Polarization-Gating and Transient-Grating Frequency-Resolved Optical Gating Using the RANA Approach

Devices that measure the presence of instability in the pulse shapes in trains of ultrashort laser pulses do not exist, so this task necessarily falls to pulse-measurement devices, like Frequency-Resolved Optical Gating (FROG) and its variations, which have proven to be a highly reliable class of techniques for measuring stable trains of ultrashort laser pulses. Fortunately, multi-shot versions of FROG have also been shown to sensitively distinguish trains of stable from those of unstable pulse shapes by displaying readily visible systematic discrepancies between the measured and retrieved traces in the presence of unstable pulse trains. However, the effects of pulse-shape instability and algorithm stagnation can be indistinguishable, so a never-stagnating algorithm—even when instability is present—is required and is generally important. In previous work, we demonstrated that our recently introduced Retrieved-Amplitude N-grid Algorithmic (RANA) approach produces highly reliable (100%) pulse-retrieval in the second-harmonic-generation (SHG) version of FROG for thousands of sample trains of pulses with stable pulse shapes. Further, it does so even for trains of unstable pulse shapes and thus both reliably distinguishes between the two cases and provides a rough measure of the degree of instability as well as a reasonable estimate of most typical pulse parameters. Here, we perform the analogous study for the polarization-gating (PG) and transient-grating (TG) versions of FROG, which are often used for higher-energy pulse trains. We conclude that PG and TG FROG, coupled with the RANA approach, also provide reliable indicators of pulse-shape instability. In addition, for PG and TG FROG, the RANA approach provides an even better estimate of a typical pulse in an unstable pulse train than SHG FROG does, even in cases of significant pulse-shape instability.

47 OTHER INSTRUMENTATION↗

ResNet and CycleGAN for pulse shape discrimination of He-4 detector pulses: Recovering pulses conventional algorithms fail to label unanimously

Pulse shape discrimination (PSD) capable detectors, such as He-4, that respond to neutron and gamma-ray 7 interactions have a threshold deposited energy value below which n/γ discrimination vanishes when using 8 conventional PSD algorithms. Recent attempts in applying supervised learning based artificial neural 9 networks for PSD use the pulses in the separated regions to train the networks so they can be used to classify 10 another set of separated pulses. In doing so, pulses previously indistinguishable are not recovered for 11 classification, which would have increased the number of neutron and gamma-ray pulses that could be used 12 for further analysis. Assuming the reason why conventional PSD algorithms have unseparated regions is 13 because the parameter space of the algorithms fail to capture the intrinsic (but subtle) distinguishing 14 behavior of some of the neutron and gamma-ray pulses, a cycle-consistent generative adversarial network 15 (CycleGAN) was trained to amplify those differences and extract well separated neutron and gamma-ray 16 clusters. Results show that, once the network is trained with pulses from separated and unseparated regions, 17 it was able to transform the pulses in the unseparated region to improve the PSD. Subsequent n/γ 18 classification was performed using deep residual network (ResNet) that takes pulses with 512 data points 19 as an input. Two different ResNets were explored – simple ResNet and modified ResNet which takes 20 segmented pulse inputs in the first layer and the corresponding time axis values in the last hidden layer. 21 The later approach enables the network to extract time correlated pulse features to enhance its ability to 22 capture the pulse behaviors relevant for PSD. Although it achieves slightly lower accuracy, 99.41% versus 23 99.89%, based on simply counting the number of correct n/γ labels assigned, compared to the simple 24 ResNet, the modified ResNets architecture was able to decreases the cross-entropy loss function by half, 25 which implies that the correct n/γ labels assigned are less likely to be accidental. PSD parameter 26 distributions based on n/γ classification by ResNet before and after transforming unseparated pulses using 27 CycleGAN show that by enhancing the separation between neutrons and gamma-rays, the transformation 28 helps improve the performance of classifier networks that are trained using labeled dataset. The 29 enhancement of neutron and gamma-ray separation by the CycleGAN increased the PSD figure of merit 30 (FOM) by up to 70% in some regions. Here, the results show that, if a given detector achieves clear separation 31 between neutron and gamma-ray pulses in any energy region, such neural network approaches can help 32 lower the energy threshold for the separation and increasing the number of neutron and gamma-ray pulses 33 that can be used for further analysis.

4He↗

Sub-100 ps laser-driven dynamic compression of solid deuterium with a ∼40 μJ laser pulse

We dynamically compress solid deuterium over <100 ps from initial pressures of 22 GPa to 55 GPa, to final pressures as high as 71 GPa, with <40 μJ of pulse energy. At 25 GPa initial pressure, we measure compression wave speeds consistent with quasi-isentropic compression and a 24% increase in density. The laser drive energy per unit density change is 10{sup 9} times smaller than it is for recent longer (∼30 ns) time scale compression experiments. This suggests that, for a given final density, dynamic compression of hydrogen might be achieved using orders of magnitude lower laser energy than currently used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impulse Response Functions for Characterizing Pulse-to-Pulse Junction Temperature Behavior in Laser Diode Pulse Trains

A method is proposed for determination of the pulse-to-pulse variation in junction temperature and emission wavelength of a semiconductor laser diode during a train of pulses. Here, this approach, based on impulse response functions, enables predictions for pulse trains with arbitrary pulse-to-pulse variations in output power, pulse width, and pulse delay using a limited set of experimental characterization data. The use of this approach is illustrated by application to a particular device structure.

Deri, Robert J. [Lawrence Livermore National Labor↗

Generating femtosecond X-ray pulses using an emittance-spoiling foil in free-electron lasers

Generation of femtosecond to sub-femtosecond pulses is attracting much attention in X-ray free-electron laser user community. One method is to use a slotted, emittance-spoiling foil which was proposed before (P. Emma et al., Phys. Rev. Lett. 92, 074801 (2004)) and has been widely used at the Linac Coherent Light Source. Direct experimental characterization of the slotted-foil performance was previously unfeasible due to a lack of appropriate diagnostics. With a recently installed X-band radio-frequency transverse deflector, we are able to characterize the electron bunch spoiling effect and X-ray pulse when using the slotted foil. We show that few-femtosecond X-ray pulses are generated with flexible control of the single-pulse duration or double-pulse separation with comparison to the theoretical model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal transport in shock wave–compressed solids using pulsed laser heating

A pulsed laser heating method was developed for determining thermal transport properties of solids under shock-wave compression. While the solid is compressed, a laser deposits a known amount of heat onto the sample surface, which is held in the shocked state by a transparent window. The heat from the laser briefly elevates the surface temperature and then diffuses into the interior via one-dimensional heat conduction. The thermal effusivity is determined from the time history of the resulting surface temperature pulse, which is recorded with optical pyrometry. Thermal effusivity is the square root of the product of thermal conductivity and volumetric heat capacity and is the key thermal transport parameter for relating the surface temperature to the interior temperature of the sample in a dynamic compression experiment. Therefore, this method provides information that is needed to determine the thermodynamic state of the interior of a compressed metal sample from a temperature measurement at the surface. The laser heat method was successfully demonstrated on tin that was shock compressed with explosives to a stress and temperature of ∼25 GPa and ∼1300 K. In this state, tin was observed to have a thermal effusivity of close to twice its ambient value. The implications on determining the interior shock wave temperature of tin are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic pulse-to-pulse thermal load effects in pulse-train-mode self-seeded X-ray free-electron laser

Thermal load has been a haunting factor that undermines the brightness and coherence of the self-seeded X-ray free-electron laser. Additionally, different from uniformly pulsed mode, in pulse train mode a thermal quasi-steady state of the crystal monochromator may not be reached. This leads to a dynamic thermal distortion of the spectral transmission curves and seed quality degradation. In this paper, the pulse-to-pulse thermal load effects on the spectral transmission curves and seed quality are shown, and some instructive information for the tuning process is provided.

47 OTHER INSTRUMENTATION↗

SWIFT OBSERVATIONS OF GAMMA-RAY BURST PULSE SHAPES: GRB PULSE SPECTRAL EVOLUTION CLARIFIED

Isolated Swift gamma-ray burst (GRB) pulses, like their higher-energy BATSE counterparts, emit the bulk of their pulsed emission as a hard-to-soft component that can be fitted by the Norris et al. empirical pulse model. This signal is overlaid by a fainter, three-peaked signal that can be modeled by the residual fit of Hakkila and Preece: the two fits combine to reproduce GRB pulses with distinctive three-peaked shapes. The precursor peak appears on or before the pulse rise and is often the hardest component, the central peak is the brightest, and the decay peak converts exponentially decaying emission into a long, soft, power-law tail. Accounting for systematic instrumental differences, the general characteristics of the fitted pulses are remarkably similar. Isolated GRB pulses are dominated by hard-to-soft evolution; this is more pronounced for asymmetric pulses than for symmetric ones. Isolated GRB pulses can also exhibit intensity tracking behaviors that, when observed, are tied to the timing of the three peaks: pulses with the largest maximum hardnesses are hardest during the precursor, those with smaller maximum hardnesses are hardest during the central peak, and all pulses can re-harden during the central peak and/or during the decay peak. Since these behaviors are essentially seen in all isolated pulses, the distinction between “hard-to-soft and “intensity-tracking” pulses really no longer applies. Additionally, the triple-peaked nature of isolated GRB pulses seems to indicate that energy is injected on three separate occasions during the pulse duration: theoretical pulse models need to account for this.

79 ASTRONOMY AND ASTROPHYSICS↗

Gas–Liquid Chemical Reactions with Nanosecond Pulses: Role of Frequency and Pulse Delivery Modes

The effects of changes in the mode of delivery of nanosecond pulses in a gas-liquid plasma reactor on the formation of hydrogen peroxide, H 2 O 2 , and, as an indicator for ·OH radicals, the decoloration of methylene blue, MB, were determined for pulse delivery by a) increasing frequency with uniform pulses (5-50 kHz), b) variation of the time between bursts of pulses (burst period), c) changing the inner burst frequency (1 over the time between the pulses in the burst), and d) variation of number of pulses in a burst (N-cycles). H 2 O 2 peroxide formation was not affected by the method of pulse delivery in the range of parameters studied here and all data followed an approximately linear increase in H 2 O 2 production rate with discharge power. In contrast, the MB decoloration rate was affected by the burst modes. In terms of discharge power, the MB decoloration rate was highest for the uniform pulse mode; however, the linear trend in increase of MB decoloration with power when the burst period was varied, suggest that at higher power the burst mode may be more effective than the uniform pulsing. Consideration of the per pulse decoloration with energy per pulse and with number of pulses suggest that the burst mode can affect reactions differently from applying a uniform pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of inter-pulse coupling on nanosecond pulsed high frequency discharge ignition in a flowing mixture

This work numerically investigates the effects of non-equilibrium nanosecond plasma discharge pulse rep- etition frequency, pulse number, and flow velocity on the critical ignition volume, minimum ignition energy, and chemistry in a plasma-assisted H 2 /air flow at 300 K and 1 atm using a multi-scale adaptive reduced chemistry solver for plasma assisted combustion (MARCS-PAC). The interactions between discharges/ignition kernels spanning decoupled, partially-coupled and fully-coupled regimes in a pulse train are studied. For a single pulse discharge, increased flow velocity increases the minimum ignition energy required due to the increase of convective heat loss and flame stretch. The results show that the minimum ignition kernel prop- agation speed at the critical ignition kernel volume increases with the flow velocity. The minimum critical ignition volume decreases with the increase of plasma discharge energy. For sequential two-pulse discharges, ignition fails at both decoupled and partially-coupled regimes even when the total discharge energy is above the minimum ignition energy, but succeeds only in the fully-coupled regime at a shorter inter-pulse time. Overlap of the OH radical pool between the sequential two-pulse discharges and the increase of the chemistry effect due to the increase of reduced electric field in the fully-coupled regime contribute to the ignition enhancement. In addition, for two-pulse discharges in the fully-coupled discharge regime, the mixture can be ignited at a total energy below the minimum ignition energy of a single pulse with the same flow conditions. Moreover, for a given total discharge energy with multiple pulsed discharges, the enhancement of the ignition kernel volume has a non-monotonic dependence on discharge frequency and pulse number. The effective ignition enhancement can be achieved with an optimal pulse repetition frequency and pulse number. Furthermore, this work provides a new understanding of the mechanism for repetitive plasma ignition and insights for the optimization of plasma ignition in a reactive flow.

42 ENGINEERING↗

Improvement in the statistical operation of a Blumlein pulse forming line in bipolar pulse mode

The paper presents the results of studies on shot-to-shot performance of a water Blumlein pulse forming line of 1–1.2 kJ of stored energy. The experiments were carried using the TEMP-4M pulsed ion beam accelerator during its operation in both unipolar pulse mode (150 ns, 250–300 kV) and bipolar-pulse mode with the first negative (300–600 ns, 100–150 kV) followed by a second positive (120 ns, 250–300 kV) pulse. The analysis was carried out for two cases when the Blumlein was terminated with a resistive load and with a self-magnetically insulated ion diode. It was found that in bipolar pulse mode the shot-to-shot variation in breakdown voltage of a preliminary spark gap is small, the standard deviation (1σ) does not exceed 2%. At the same time, the shot-to-shot variation in the breakdown voltage of the main spark gap in both bipolar-pulse and unipolar pulse mode is 3–4 times higher than that for the preliminary spark gap. To improve the statistical performance of the main spark gap we changed the regime of its operation from a self-triggered mode to an externally triggered mode. In the new arrangement the first voltage pulse at the output of Blumlein was used to trigger the main spark gap. The new trigatron-type regime of the main spark gap operation showed a good stability of breakdown voltage and thus allowed to stabilize the duration of the first pulse. The standard deviation of the breakdown voltage and duration of the first pulse did not exceed 2% for a set of 50 pulses. The externally triggered mode of the main gap operation also allowed for a decrease in the charging voltage of the Blumlein to a 0.9–0.95 of self-breakdown voltage of the main spark gap while the energy stored in Marx generator was decreased from 4 kJ to 2.5 kJ. At the same time the energy stored in Blumlein remained the same.

43 PARTICLE ACCELERATORS↗

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unstable and multiple pulsing can be invisible to ultrashort pulse measurement techniques

Here, multiple pulsing occurs in most ultrashort-pulse laser systems when pumped at excessively high powers, and small fluctuations in pump power in certain regimes can cause unusual variations in the temporal separations of sub-pulses. Unfortunately, the ability of modern intensity-and-phase pulse measurement techniques to measure such unstable multi-pulsing has not been studied. Here we report calculations and simulations finding that allowing variations in just the relative phase of a satellite pulse causes the second pulse to completely disappear from a spectral interferometry for direct electric field reconstruction (SPIDER) measurement. We find that, although neither frequency-resolved optical gating (FROG) nor autocorrelation can determine the precise properties of satellite pulses due to the presence of instability, they always succeed in, at least, seeing the satellite pulses. Also, additional post-processing of the measured FROG trace can determine the correct approximate relative height of the satellite pulse and definitively indicate the presence of unstable multiple-pulsing.

42 ENGINEERING↗

Pulsed electron beam generation with fast repetitive double pulse system

Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

43 PARTICLE ACCELERATORS↗