Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse trains”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Alignment of asymmetric-top molecules using multiple-pulse trains

We theoretically analyze the effectiveness of multiple-pulse laser alignment methods for asymmetric-top molecules. As an example, we choose SO{sub 2} and investigate the alignment dynamics induced by two different sequences, each consisting of four identical laser pulses. Each sequence differs only in the time delay between the pulses. Equally spaced pulses matching the alignment revival of the symmetrized SO{sub 2} rotor model are exploited in the first sequence. The pulse separations in the second sequence are short compared to the rotation dynamics of the molecule and monotonically increase the degree of alignment until the maximum alignment is reached. We point out the significant differences between the alignment dynamics of SO{sub 2} treated as an asymmetric-top and a symmetric-top rotor, respectively. We also explain why the fast sequence of laser pulses creates considerably stronger one-dimensional molecular alignment for asymmetric-top molecules. In addition, we show that multiple-pulse trains with elliptically polarized pulses do not enhance one-dimensional alignment or create three-dimensional alignment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dissociative ionization of H{sub 2} in an attosecond pulse train and delayed laser pulse

The ionization of H{sub 2} in a single attosecond extreme ultraviolet (XUV) pulse generates a nuclear wave packet in H{sub 2}{sup +}, which is entangled with the emitted photoelectron wave packet. The nuclear wave-packet dynamics can be observed by dissociating H{sub 2}{sup +} in a delayed IR laser pulse. If H{sub 2} is ionized by a sequence of XUV pulses of an attosecond pulse train, whether or not the corresponding sequence of nuclear wave packets in H{sub 2}{sup +} is detected as a coherent or incoherent superposition depends on whether and how the photoelectrons are observed. We simulate the nuclear dynamics in this XUV-pump-IR-probe scenario and analyze our numerical results for both single attosecond pump pulses and pump-pulse trains of different lengths and temporal spacings between individual XUV pulses. By superimposing nuclear wave packets in H{sub 2}{sup +} generated by individual pulses in the pump-pulse train incoherently, we calculate proton kinetic energy release spectra that are in good qualitative agreement with the recent experiment of Kelkensberg et al. [Phys. Rev. Lett. 103, 123005 (2009)].

74 ATOMIC AND MOLECULAR PHYSICS↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

Control of Electron Localization in Deuterium Molecular Ions using an Attosecond Pulse Train and a Many-Cycle Infrared Pulse

We demonstrate an experimental control of electron localization in deuterium molecular ions created and dissociated by the combined action of an attosecond pulse train and a many-cycle infrared (IR) pulse. The attosecond pulse train is synthesized using both even and odd high order harmonics of the driving IR frequency so that it can strobe the IR field once per IR cycle. An asymmetric ejection of the deuterium ions oscillates with the full IR period when the APT-IR time-delay is scanned. The observed control is due to the creation of a coherent superposition of 1s {sigma}{sub g} and 2p {sigma}{sub u} states via interference between one-photon and two-photon dissociation channels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Adjustment of ablation shapes and subwavelength ripples based on electron dynamics control by designing femtosecond laser pulse trains

A quantum model is proposed to investigate femtosecond laser pulse trains processing of dielectrics by including the plasma model with the consideration of laser particle-wave duality. Central wavelengths (400 nm and 800 nm) strongly impact the surface plasmon field distribution, the coupling field intensity distribution (between the absorbed intensity and the surface plasma), and the distribution of transient localized free electron density in the material. This, in turn, significantly changes the localized transient optical/thermal properties during laser materials processing. The effects of central wavelengths on ablation shapes and subwavelength ripples are discussed. The simulation results show that: (1) ablation shapes and the spacing of subwavelength ripples can be adjusted by localized transient electron dynamics control using femtosecond laser pulse trains; (2) the adjustment of the radii of ablation shapes is stronger than that of the periods of subwavelength ripples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An experimental comparison of triggered and random pulse train uncertainties

In this paper we present an experimental comparison of signal-triggered and randomly triggered based analysis algorithms of neutron multiplicity data. Traditional shift register type signal-triggered multiplicity analysis of singles, doubles and triples rates is compared with analysis using randomly triggered gates. Two methods of random gate generation are explored - non-overlapping gates (Feyrunan approach) and periodic overlapping gates (fast accidentals). Using californium sources with low, medium and high rate in combination with AmLi sources (as a surrogate for plutonium) we investigate relative standard deviation (RSD) of data in order to determine if there are parameter spaces in which one of the measurement methods should be preferred. Neutron correlation analysis is a commonly used NDA technique to assay plutonium mass. The data can be collected in two distinct ways: using signal-triggered or randomly triggered counting gates. Analysis algorithms were developed for both approaches to determine singles (S), doubles (D) and triples (7) rates from the measured sample. Currently the most commonly implemented technique to collect neutron coincidence data utilizes shift register based electronics. Shift register uses signal-triggered counting gates to generate foreground multiplicity distribution of correlated+accidental events and a random gate (opened after a predefined long delay following the signal trigger) to generate background multiplicity distribution of accidental events. Modern shift registers include fast accidental option to sample data with a fixed clock frequency. This way a set of overlapping gates is used to generate background multiplicity distributions in order to improve the measurement precision. In parallel to shift register approach the Feynman variance technique is frequently used, which utilizes set of consecutive non-overlapping gates. In general, different user communities (e.g. safeguards, nuclear material accountancy, emergency response) have used only one of the two analysis methods for the nuclear material assay. The aim of this study is to provide a systematic comparison of the precision of the measured S, D, T rates and {sup 240}Pu effective mass obtained using the above mentioned pulse train sampling techniques. In order to perform this task, a LANL developed list mode based data acquisition system is used, where the entire pulse train is recorded and subsequently analyzed. The list mode acquisition brings an essential advantage for this type of comparison, since the very same pulse train can be analyzed using signal-triggered as well as randomly triggered counting gates. The aim of this study is not only to compare the precision of signal-triggered versus random triggered sampling techniques, but also to investigate the influence of fast accidental sampling on the precision of signal-triggered results. In addition the different random sampling techniques used in safeguards are investigated. For this purpose we implement two types of random sampling - non-overlapping gates (Feynrnan approach) and periodic overlapping gates (fast accidentals). In the following sections the equations utilized in the pulse train analysis are described, experimental setup and measurement techniques are discussed and finally the results are summarized and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observation of cold Rb{sub 2} molecules trapped in an optical dipole trap using a laser-pulse-train technique

In this work, we have developed and characterized a laser-pulse-train technique to observe cold Rb{sub 2} molecules trapped in an optical dipole trap. The molecules are produced in a magneto-optical trap, and then loaded into a crossed optical dipole trap. The time evolution of the molecular population is obtained by applying a laser pulse train, which photoionizes the ground-state molecules through intermediate molecular bands. Our results show that this technique allows us to obtain a faster data acquisition rate of the time evolution of the molecule population than other techniques.

74 ATOMIC AND MOLECULAR PHYSICS↗

Influence of propagation on the coherent accumulation of excitation induced by an ultrashort pulse train

We study the effects of propagation through an extended sample of two- and three-level atoms on the coherent accumulation of excitation by an ultrashort pulse train. In the two-level case, previous pulses in the train may prepare the medium such that a later pulse may experience amplification and absorption in different positions inside the sample. For a large number of pulses, the atomic medium may be saturated by the train, and some pulses propagate without experiencing either absorption or amplification. In general, absorption of the resonant pulse frequency during propagation compromises the accumulation efficiency. In the three-level case, the coherent accumulation of excitation leads to electromagnetically induced transparency of the pulse train, and the pulses exit the medium without any distortion in their temporal profile.

74 ATOMIC AND MOLECULAR PHYSICS↗

Controlling the Spacing of Attosecond Pulse Trains from Relativistic Surface Plasmas

When a laser pulse hits a solid surface with relativistic intensities, XUV attosecond pulses are generated in the reflected light. We present an experimental and theoretical study of the temporal properties of attosecond pulse trains in this regime. The recorded harmonic spectra show distinct fine structures which can be explained by a varying temporal pulse spacing that can be controlled by the laser contrast. The pulse spacing is directly related to the cycle-averaged motion of the reflecting surface. Thus the harmonic spectrum contains information on the relativistic plasma dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrashort-pulse-train pump and dump excitation of a diatomic molecule

An excitation scheme is proposed for transferring population between ground-vibrational levels of a molecule. The transfer is accomplished by pumping and dumping population with a pair of coherent ultrashort-pulse trains via a stationary state. By mismatching the teeth of the frequency combs associated with the pulse trains to the vibrational levels, high selectivity in the excitation, along with high transfer efficiency, is predicted. The pump-dump scheme does not suffer from spontaneous emission losses, it is insensitive to the pump-dump-train delay, and it requires only basic pulse shaping.

74 ATOMIC AND MOLECULAR PHYSICS↗

Generation of multiple attosecond sub-bursts in femtosecond pulse trains by long-wavelength driving lasers

High-order harmonics generated by a long intense femtosecond laser are known experimentally to create attosecond pulse trains (APTs). In the time domain, an APT consists of a sequence of sharp attosecond bursts that are equally separated by each half optical cycle. Here, in this work, we show that such well-known features can be modified when a longer wavelength driving laser is used. From our simulations, we show that multiple shorter attosecond sub-bursts exist in the femtosecond pulse train within each half optical cycle and the duration of each sub-burst scales approximately as $λ^{–2}_0$ with the driving laser wavelength λ 0 . We show that such sub-bursts can be found using quantitative rescattering model for harmonics generated from a single atom, and their origin is due to the interference of the quantum orbits from first two returns of the recombining electron. We further show that such sub-bursts can be phase matched under proper laser focusing condition and the position of the gas cell, thus, such new features should be observable experimentally.

47 OTHER INSTRUMENTATION↗

Impulse Response Functions for Characterizing Pulse-to-Pulse Junction Temperature Behavior in Laser Diode Pulse Trains

A method is proposed for determination of the pulse-to-pulse variation in junction temperature and emission wavelength of a semiconductor laser diode during a train of pulses. Here, this approach, based on impulse response functions, enables predictions for pulse trains with arbitrary pulse-to-pulse variations in output power, pulse width, and pulse delay using a limited set of experimental characterization data. The use of this approach is illustrated by application to a particular device structure.

Deri, Robert J. [Lawrence Livermore National Labor↗

A bright attosecond x-ray pulse train generation in a double-laser-driven cone target

By using full three-dimensional particle-in-cell and Monte Carlo simulations, we investigate the generation of a high-brightness attosecond x-ray pulse train in a double-laser-driven cone target. The scheme makes use of two lasers: the first high-intensity laser with a laser peak intensity 1.37 × 10{sup 20 }W/cm{sup 2} irradiates the cone and produces overdense attosecond electron bunches; the second counterpropagating weakly relativistic laser with a laser peak intensity 4.932 × 10{sup 17 }W/cm{sup 2} interacts with the produced electron bunches and a bright x-ray pulse train is generated by Thomson backscattering of the second laser off the attosecond electron bunches. It is shown that the photon flux rises by 5 times using the cone target as compared with a normal channel. Meanwhile, the x-ray peak brightness increases significantly from 1.4 × 10{sup 21}/(s mm{sup 2} mrad{sup 2} 0.1 keV) to 6.0 × 10{sup 21}/(s mm{sup 2} mrad{sup 2} 0.1 keV), which is much higher than that of the Thomson x-ray source generated from traditional accelerators. We also discuss the influence of the laser and target parameters on the x-ray pulse properties. This compact bright x-ray source may have diverse applications, e.g., the study of electric dynamics and harmonics emission in the atomic scale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High harmonic attosecond pulse train amplification in a free electron laser

It is shown using three-dimensional simulations that the temporal structure of an attosecond pulse train, such as that generated via high harmonic generation in noble gases, may be retained in a free electron laser amplifier through to saturation using a mode-locked optical klystron configuration. At wavelengths of {approx}12 nm, a train of attosecond pulses of widths {approx}300 as with peak powers in excess of 1 GW are predicted.

43 PARTICLE ACCELERATORS↗

Differential-phase-shift quantum key distribution with segmented pulse trains

We present a modified scheme of differential-phase-shift (DPS) quantum key distribution (QKD) for improving its performance. A transmitter sends a weak coherent pulse train segmented with vacant pulses. Then, a receiver can find eavesdropping by monitoring the photon detection rate at particular time slots. Simulations show that the proposed scheme is robust against a sequential attack and a general individual attack.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photoemission electron microscopy using extreme ultraviolet attosecond pulse trains

We report the first experiments carried out on a new imaging setup, which combines the high spatial resolution of a photoemission electron microscope (PEEM) with the temporal resolution of extreme ultraviolet (XUV) attosecond pulse trains. The very short pulses were provided by high-harmonic generation and used to illuminate lithographic structures and Au nanoparticles, which, in turn, were imaged with a PEEM resolving features below 300 nm. We argue that the spatial resolution is limited by the lack of electron energy filtering in this particular demonstration experiment. Problems with extensive space charge effects, which can occur due to the low probe pulse repetition rate and extremely short duration, are solved by reducing peak intensity while maintaining a sufficient average intensity to allow imaging. Finally, a powerful femtosecond infrared (IR) beam was combined with the XUV beam in a pump-probe setup where delays could be varied from subfemtoseconds to picoseconds. The IR pump beam could induce multiphoton electron emission in resonant features on the surface. The interaction between the electrons emitted by the pump and probe pulses could be observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

Reliable Determination of Pulses and Pulse-Shape Instability in Ultrashort Laser Pulse Trains Using Polarization-Gating and Transient-Grating Frequency-Resolved Optical Gating Using the RANA Approach

Devices that measure the presence of instability in the pulse shapes in trains of ultrashort laser pulses do not exist, so this task necessarily falls to pulse-measurement devices, like Frequency-Resolved Optical Gating (FROG) and its variations, which have proven to be a highly reliable class of techniques for measuring stable trains of ultrashort laser pulses. Fortunately, multi-shot versions of FROG have also been shown to sensitively distinguish trains of stable from those of unstable pulse shapes by displaying readily visible systematic discrepancies between the measured and retrieved traces in the presence of unstable pulse trains. However, the effects of pulse-shape instability and algorithm stagnation can be indistinguishable, so a never-stagnating algorithm—even when instability is present—is required and is generally important. In previous work, we demonstrated that our recently introduced Retrieved-Amplitude N-grid Algorithmic (RANA) approach produces highly reliable (100%) pulse-retrieval in the second-harmonic-generation (SHG) version of FROG for thousands of sample trains of pulses with stable pulse shapes. Further, it does so even for trains of unstable pulse shapes and thus both reliably distinguishes between the two cases and provides a rough measure of the degree of instability as well as a reasonable estimate of most typical pulse parameters. Here, we perform the analogous study for the polarization-gating (PG) and transient-grating (TG) versions of FROG, which are often used for higher-energy pulse trains. We conclude that PG and TG FROG, coupled with the RANA approach, also provide reliable indicators of pulse-shape instability. In addition, for PG and TG FROG, the RANA approach provides an even better estimate of a typical pulse in an unstable pulse train than SHG FROG does, even in cases of significant pulse-shape instability.

47 OTHER INSTRUMENTATION↗