Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse_width”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The impact of pulse width modulation on heat accumulation in AlGaN channel HEMTs

The poor thermal properties of Aluminum–Gallium Nitride (AlGaN) channel High Electron Mobility Transistors (HEMTs) on sapphire limit the device’s maximum switching frequency due to high channel temperatures. Extracting the correct thermal time constants can provide guidelines for the device’s safe frequency operation. This study experimentally quantifies the impact of pulse width and duty cycle on the transient thermal dynamics of multi-finger AlGaN channel HEMTs. In most transient thermal metrology, lock-in averaging approaches are leveraged to increase signal-to-noise ratio and measure the device’s relative temperature rise. Assuming no heat accumulation, the temperature rise is used to quantify the device’s thermal resistance under continued pulsed biasing. For devices grown on sapphire substrates, however, heat accumulation leads to elevated reference temperatures and causes the differential measurement to underestimate the peak temperature. This study demonstrates the capability of transient Gate Resistance Thermometry (tGRT) to measure the absolute temperature, which is required to precisely evaluate the device’s thermal resistance. When an absolute temperature measurement is not feasible (such as thermoreflectance imaging), a solution is proposed to derive the peak temperature under pulsed biasing based on the differential temperature under pulsing and the steady-state thermal resistance (which is typically easier to obtain). Finally, additional tGRT (without averaging) is performed to demonstrate the temperature-dependent thermal time constants required to minimize heat accumulation effects.

Field effect transistors↗

Incident excitation effects on ZnO-based photoluminescence

Zinc oxide (ZnO) is an attractive semiconductor material owing to a wide band gap, large exciton binding energy, and strong luminescent properties. Two distinct spectral regions are present in the room temperature emission of this material: a narrow line in the UV/near-UV region that is excitonic in nature and a lower energy broad emission band centered in the green/yellow region. Commercially available ZnO particles containing excess Zn and oxygen vacancy defect sites (referred to as ZnO:Zn) were excited using three light sources to study different radiative recombination regimes of the as-received powders. First, a UV LED at a center wavelength of 365 nm provided low irradiance (0.02–0.08 W/cm 2 ) with varying pulse widths (continuous operation to 16 ns). Second, the third harmonic of a pulsed Nd:YAG laser provided high irradiances (∼10 4 –10 6 W/cm 2 ) at a fixed nominal pulse width of 5 ns. Finally, a continuous polychromatic synchrotron X-ray source was also used to excite the ZnO:Zn powders. During UV LED excitation, a low number of carriers are created in the material, leading to an anticipated linear relationship between luminescence and irradiance. This held true for defect luminescence; however, there was an observed enhancement of exciton emission relative to the UV LED intensity as the pulse width was decreased, independent of irradiance. During UV laser excitation, the number of carriers was significantly increased, raising the material into a bimolecular recombination regime, which produced exciton emission much stronger than visible band emission. Finally, spectra obtained during synchrotron X-ray excitation, whose continuous illumination and higher penetration depth yielded higher emission from defect sites relative to exciton emission. A redshift in the exciton emission was also observed as excitation pulse width and sample temperature were varied, and is discussed.

Westphal, Eric Robert [Sandia National Lab. (SNL-N↗

Characterization of Fuel-to-Coolant Heat Transfer During Reactivity-Initiated Accidents Using Tightly Coupled Thermal Hydraulics and Fuel Thermomechanics

The reactivity-initiated accident (RIA) is a complex scenario with several tightly interacting physical phenomena. Accurately predicting fuel behavior during these transients is difficult due to limitations in the modeling of fuel-to-coolant heat transfer. Common approaches to simulate RIAs involve standalone calculations using either a fuel performance code or a thermal-hydraulic code. The complex interdependencies of thermal-hydraulic and fuel mechanical behavior suggest that a tight coupling between these codes may provide more accurate predictions of fuel-to-coolant heat transfer and cladding mechanical response. Here, RELAP5-3D and BISON are coupled in this paper to simulate RIAs, and a sensitivity analysis is performed to rank key thermal properties and two-phase heat transfer parameters relevant for fuel-to-coolant heat transfer and cladding failure mechanisms in UO 2 –Zircaloy-4 systems. Gas gap conductance, film boiling heat transfer uncertainty, pulse width, fuel-specific heat capacity, and cladding-specific heat capacity were identified as important parameters. Variations in figures of merit resulting from changes to pulse width and the material thermal properties indicate that time-dependent heat transfer rates are significant for safety-relevant mechanical parameters due to the time dependence of cladding ductility and pellet-cladding mechanical interaction loading. The results suggest that the thermal-hydraulic factors have a nonnegligible influence on the thermomechanical solution and vice versa. Tight coupling of both sets of physics is recommended to improve prediction of fuel behavior during RIAs. Highlights include the following: 1. The RELAP5-3D thermal-hydraulic code and the BISON fuel performance code are tightly coupled for simulation of RIA transients with energy depositions at the Zircaloy-4 cladding failure threshold. 2. Departure from nucleate boiling occurred for all simulated cases. Due to the ductility of fresh fuel, substantial ballooning occurred in most cases. 3. Gas gap conductance, fuel-specific heat capacity, cladding-specific heat capacity, transient pulse width, and film boiling heat transfer were the dominant thermal factors impacting the safety figures of merit at energy depositions.

Critical Heat Flux (CHF)↗

Wind and Temperature Consensus at Horn Point, HU-Beltsville, Piney Run (Maryland) in support of CoURAGE

The Maryland Department of the Environment (MDE) operates a ground-based atmospheric profiling network consisting of collocated radar wind profilers (RWP) and radio acoustic sounding systems (RASS) as part of its Ambient Air Monitoring Program. This network provides continuous observations of wind and temperature structure in the lower troposphere to support air quality forecasting, regulatory analysis, and atmospheric research. The network currently includes three fixed sites across Maryland: Horn Point (HP, lower eastern shore) [38.587525°,-76.141006°], Howard University-Beltsville (HUB, central Maryland) [39.055277°, -76.878632°], and Piney Run (PR, western Maryland) [39.705950°, -79.012000°] The network is designed to capture regional variability in atmospheric transport and boundary-layer processes. These systems measure vertical profiles of horizontal wind speed and direction using Doppler radar techniques, with observations typically spanning from ~100 m above ground level up to approximately 2.5–4 km. Measurements are derived from the Doppler shift of backscattered electromagnetic signals, enabling retrieval of wind vectors at multiple altitudes with high temporal resolution (e.g., 30-minute averages reported every 6 minutes). Each radar wind profiler is paired with a Radio Acoustic Sounding System (RASS) to provide profiles of virtual temperature in the lower atmosphere (~100–200 m AGL) by measuring the propagation speed of acoustic waves. Together, the RWP/RASS system yields a coupled data set of thermodynamic and kinematic atmospheric structure, including additional parameters such as vertical velocity, radial velocity, signal-to-noise ratio, and spectral width for advanced analysis. There are two types of files for each station: wind data (files with a "w" prefix) and virtual temperature RASS data (files with a "t" prefix). The wind data files are in the format wYYDDD.cns, where YY is the 2-digit year and DDD is the day of the year. The RASS virtual temperature data files are in the format tYYDDD.cns. Each record has the following header structure: Line 1 : Station Name RASS files Line 2 : RASS rev DeTect_2.0, WINDS files Line 2 : WINDS rev ATI 5.1 Line 3 : N latitude, W longitude, and site elevation (m) Line 4 : Date and begin time of consensus: yy mm dd hh mn ss plus # minutes to add to get UTC Line 5 : Consensus averaging time (minutes); number of beams; number of range gates Line 6 : Number of records required to make consensus (num) total number of records (tot) and the consensus window size (m/s) in the format: num:tot (window) RASS files Line 7 : no. of coded cells, no. of spec, pulse width (ns), and inter-pulse period (µs), WINDS files Line 7 : No. of coded cells, no. of spectra, pulse width (ns), and inter-pulse period (µs), each with a pair of values: first value is for oblique beams, second for vertical RASS files Line 8 : Full scale Doppler value (m/s) Delay to first gate (ns) Number of gates Spacing of gates (ns), WINDS files Line 8 : Full scale Doppler velocity (m/s), oblique and vertical Vertical correction applied to oblique beams? (0 = no, 1 = yes) Delay to first gate (ns), oblique and vertical Number of gates, oblique and vertical Spacing of gates (ns), oblique and vertical Line 9 : Azimuth and elevation (9s indicate vertical beam not used) RASS files Line 10, values : HT = Height above ground (km), T = Uncorrected virtual temperature consensus (deg C), Tc = Corrected virtual temperature consensus (deg C), W = Vertical wind consensus (9s indicate vertical beam not used, w-component, positive upward, m/s), CNT = Number of records that made consensus (for the 3 values in same order), SNR = Average signal to noise ratio (dB) of records in consensus (same order) WINDS files Line 10, values : HT = Height above ground (km), SPD = Wind speed (m/s), DIR = Wind direction (deg E of N from N), RAD = Radial velocities for each beam (m/s) in order given in azimuth and elevation line (positive toward radar; 9s indicate vertical beam not used, CNT = Number of records that made consensus, SNR = Average signal to noise ratio (dB) of records in consensus

{"wind speed and direction",temperature}↗

Ultrafast Laser Welding and Terahertz Time-domain Spectroscopy of Soda Lime Silicate Glass

Joining and welding techniques of similar and dissimilar materials have reached their limits due to the inflexibility of adapting dielectric materials, e.g., glasses and ceramics, reproducibility for transparent materials, and cycle process time. The ability to join pieces of glasses using laser irradiation allows rapid processing of vacuum insulating glass (VIG) for a widening range of commercial energy-efficient applications. We have used a 1064-nm laser wavelength with 15 picoseconds pulse width and a 155-kHz repetition rate to weld commercial plate glass pieces. The welded samples were characterized via x-ray fluorescence (XRF), time-of-flight secondary ion mass spectrometry (TOF–SIMS), polarimetry, and terahertz time-domain spectroscopy (THz-TDS) to determine the integrity of the weld and chemical changes in the welded areas. Our data shows no significant changes in glass chemistry and structure on average over nano- to micro-scales occurred from the welding process within the limits of the characterization tools. Our results demonstrate successful welding of glass plates without significant changes in the glass chemistry, structure, or properties in the laser-modified region or strains in the bulk glass.

Matthies, Kathleen [ORNL] (ORCID:0009000213135441)↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Wide-Bandgap Semiconductor Amplifiers for Fusion Plasma Heating and Control

This paper discusses power electronics developed under the ARPA-E GAMOW program to support nuclear fusion power production. The goal of this project was to develop and assess the potential for wide-bandgap (WBG) semiconductor devices in power electronics to enable high-efficiency and high-voltage solid-state systems for fusion plasma generation, heating, and control. The power electronics use an architecture in which multiple high-power boards can be combined to produce megawatt-level power, where using multiple boards provides high reliability. Two main areas of power electronics boards are developed in this project for fusion plasma heating and control applications: (1) pulse generation and control and (2) radiofrequency generation. The first area is for boards capable of driving high-voltage millisecond pulses at high duty cycles. The envisioned application of these pulses is in plasma control of magnetohydrodynamic instabilities, plasma position, and edge-localized modes. Pulse-width modulation allows for the implementation of a wide variety of linear and nonlinear control systems. The boards developed for this project could actuate control coils based on digital input signals and can be parallelized to provide megawatts of output power. The design of the pulse generator is a low-side load switch. A load switch was designed and constructed that utilized 2-kV-rated field-effect transistor (FET)-based cascodes developed by Qorvo under this project to perform initial testing of these cascodes. The second area is being implemented using class E amplifiers with WBG devices and a reactance steering network to handle inductive or capacitive plasma loads. Applications include ion cyclotron resonance heating (ICRH) and high-harmonic fast-wave (HHFW) heating. A class E reactance steering network is demonstrated in modeling and experiment with a resistive-inductive load that models an inductively-coupled plasma. Power combining of boards with class E reactance steering networks is also simulated and demonstrated experimentally, to enable scaling up to high power. Modeling of high-power-density cooling and remaining useful life is conducted to enable reliable, effectively cooled high-power electronics for fusion applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

Magneto-optical spectroscopy based on pump-probe strobe light

Here, we demonstrate a pump-probe strobe light spectroscopy for sensitive detection of magneto-optical dynamics in the context of hybrid magnonics. The technique uses a combinatorial microwave-optical pump-probe scheme, leveraging both the high-energy resolution of microwaves and high-efficiency detection using optical photons. In contrast with conventional stroboscopy using continuous-wave light, we apply microwave and optical pulses with varying pulse widths, and demonstrate magneto-optical detection of magnetization dynamics in Y 3 Fe 5 O 12 films. The detected magneto-optical signals depend strongly on the characteristics of both the microwave and the optical pulses, as well as their relative time delays. We show that good magneto-optical sensitivity and coherent stroboscopic character are maintained, even at a microwave pump pulse of 1.5 ns and an optical probe pulse of 80 ps, under a 7 MHz clock rate, corresponding to a pump-probe footprint of approximately 1% in one detection cycle. Our results show that time-dependent strobe light measurement of magnetization dynamics can be achieved in the gigahertz frequency range under a pump-probe detection scheme.

36 MATERIALS SCIENCE↗

Impulse Response Functions for Characterizing Pulse-to-Pulse Junction Temperature Behavior in Laser Diode Pulse Trains

A method is proposed for determination of the pulse-to-pulse variation in junction temperature and emission wavelength of a semiconductor laser diode during a train of pulses. Here, this approach, based on impulse response functions, enables predictions for pulse trains with arbitrary pulse-to-pulse variations in output power, pulse width, and pulse delay using a limited set of experimental characterization data. The use of this approach is illustrated by application to a particular device structure.

Deri, Robert J. [Lawrence Livermore National Labor↗

Testing of Novel Semiconductor Opening Switches Using Magnetic Switching

The performance of semiconductor opening switch (SOS) diodes with different doping profiles is assessed with the primary aim of enhancing or substituting hard-to-find devices. SOS devices are capable of providing long lifetime, gigawatt level pulses in generators with risetimes on the nanosecond scale with pulse widths on the order of 20 ns. An experimental testbed is described which allows for rapid testing of diodes with control of the forward pumping time which is a crucial parameter of SOS diodes. A saturable pulse transformer provides both the initial voltage multiplication and reverse current pulse required to drive SOS diodes. Voltage multiplication ratios of 16:1 were achieved with a modest charging voltage of 800 V and simple circuitry. With current densities of up to 1.4 kA ⋅ cm -2 , the testbed produces 10 kV output pulses into a 56 Ω load with a pulsewidth of 16 ns and delivered power of up to 1.9 MW. These novel devices are compared to legacy SOS diodes originating from Russia, with one of the profiles yielding increased performance. Finally, these profiles are studied in hopes of creating manufacturing demand to augment the availability of these useful devices.

drift step recovery diodes↗

Experimental investigation of longitudinal scraping of H- bunches via photo-detachment

Longitudinal emittance growth is a significant challenge in RF linacs, especially for poorly bunched beams. This stems from particles occupying outer synchrotron oscillation orbits in the LBET, causing unwanted bunch-bunch interactions and degraded beam quality. To address this, we proposed using temporally spaced laser pulses to selectively photo-detach electrons from the longitudinal head and tail regions of H- ion bunches. This approach aims to reduce particle density in extreme orbits, enhancing beam uniformity and limiting emittance growth. Our experiments employed Fermilab's 'LaserNotcher' system at the font end of the linac, delivering 1.6 MW peak power with sub-nanosecond precision. By neutralizing the first and last half-nanosecond of several H- bunches, we measured their propagation injection into the booster. Measurements of pulse width, average height, and temporal spacing over booster cycles were compared between the scraped and unscraped bunches. Statistical analysis evaluated the results’ significance, highlighting the feasibility of laser-based scraping for future linac designs to achieve higher beam energies with improved emittance control.

Landon, Parker [Boston U.]↗

Improved Chopper System for a Direct Geometry Spectrometer at the Second Target Station

This report describes a chopper cascade suitable for a cold direct geometry spectrometer at a pulsed neutron source with a low repetition rate such as the Second Target Station (STS) currently being planned at Oak Ridge National Laboratory (ORNL). The chopper cascade offers the following capabilities: selection of a variable number of pulses per frame (flexible pulse suppression), selection of pulses with increasing timing separation within one frame, and an increasing pulse width ∆t within one frame, in order to achieve an even energy resolution over several pulses at different wavelengths across the frame.

43 PARTICLE ACCELERATORS↗

Setup and Testing of the RS105 Wire Array Pulser

The report covers the RS105 Wire Array Pulser testbed. The setup of the wire array at Reapplication, building 996, is laid out. Setup instructions are provided. Details of the commissioning test are given. Measurement data from the commissioning test shows the field output of the array exceeds 50 kV/m and that tuning the pulser output with a peaking switch can provide a rise time of ~2.3 ns and a pulse width of ~23 ns. The field levels and timeframes shown are within the tolerance conditions of

42 ENGINEERING↗

Gallium Arsenide Semiconductor Opening Switches: Enabling Nanosecond High Powering Pulsed Systems

The goal of this work awas to investigate design manufacturing semiconductor opening switches (SOS) in both silicon and gallium arsenide (GaAs). Solid-state opening switches are critical components for pulsed power systems and applications in directed energy, dielectric wall accelerators, and novel semiconductor manufacturing techniques. Under this funding, we have developed silicon SOS designs that suppresses an unwanted prepulse, increases the peak output voltage by about 10 percent, and reduces the pulse rise time by ~ 4x compared with more conventional profiles. Through this effort we have improved device fabrication and bonding techniques. Additionally, work on this the GaAs opening switch has defined a unique application space that these devices are suited for. GaAs opening switches have short risetimes and pulse widths compared to silicon devices, however the short carrier lifetime of GaAs makes the circuit design more challenging than in silicon. For high PRF operation, the lifetime of the GaAs is an advantage compared to silicon. TCAD simulations of GaAs devices have been used to optimize a GaAs profile. Additionally, we have designed pulsers with sub 50ns reserve pump times and tested GaAs COTs PIN diodes in them.

42 ENGINEERING↗

Characterization of Digital Silicon Photomultipliers

Digital Silicon photomultipliers (Digital SiPMs) have become an increasingly viable option for single-photon detection due to their compact size and precise timing and resolution. The following work characterizes the noise performance of a diSiPM designed and tested in-house at Fermilab. The SiPM consists of a 26x32 array of single-photon avalanche diode (SPAD) cells. Through the implementation of a shift register masking circuit, individual SPAD cells can be enabled and disabled at will, allowing for precise detection measurements of single columns (accumulator channels) and cells. The provided circuit design operates on voltage clock pulses and collects data on clock edges allowing for precise tuning of the data collection process by varying the clock frequency, pulse width, and integration period.

Shoemaker, Oliver [U. Chicago (main)]↗