Search NASA⌕ Search

SEARCH · Search NASA

Results for “ray path geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PCalc User's Manual

PCalc is a software tool that computes travel-time predictions, ray path geometry and model queries. This software has a rich set of features, including the ability to use custom 3D velocity models to compute predictions using a variety of geometries. The PCalc software is especially useful for research related to seismic monitoring applications.

58 GEOSCIENCES↗

pCalc User's Manual

pCalc is a software tool that computes travel-time predictions, ray path geometry and model queries. This software has a rich set of features, including the ability to use custom 3D velocity models to compute predictions using a variety of geometries. The pCalc software is especially useful for research related to seismic monitoring applications. The pCalc software is available on the web at: www.sandia.gov/salsa3d/Software.html The software is packaged with this user's manual and a set of example datasets, the use of which is described in this manual.

97 MATHEMATICS AND COMPUTING↗

Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model

Purpose: The authors describe the modifications to a previously developed analytical model of indirect CsI:Tl-based detector response required for studying oblique x-ray incidence effects in direct semiconductor-based detectors. This first-order approximation analysis allows the authors to describe the associated degradation in resolution in direct detectors and compare the predictions to the published data for indirect detectors. Methods: The proposed model is based on a physics-based analytical description developed by Freed et al. [''A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems,'' Med. Phys. 37(6), 2593-2605 (2010)] that describes detector response functions for indirect detectors and oblique incident x rays. The model, modified in this work to address direct detector response, describes the dependence of the response with x-ray energy, thickness of the transducer layer, and the depth-dependent blur and collection efficiency. Results: The authors report the detector response functions for indirect and direct detector models for typical thicknesses utilized in clinical systems for full-field digital mammography (150 {mu}m for indirect CsI:Tl and 200 {mu}m for a-Se direct detectors). The results suggest that the oblique incidence effect in a semiconductor detector differs from that in indirect detectors in two ways: The direct detector model produces a sharper overall PRF compared to the response corresponding to the indirect detector model for normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction compared to that found in indirect detectors with respect to the response at normal incidence angles. Conclusions: Compared to the effect seen in indirect detectors, the direct detector model exhibits a sharper response at normal x-ray incidence and a larger relative increase in blur along the x-ray incidence direction with respect to the blur in the orthogonal direction. The results suggest that the oblique incidence effect in direct detectors can be considered to be caused mostly by the geometry of the path where the x-ray beam and its secondary particles deposit energy in the semiconductor layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE CHROMOSPHERIC SOLAR LIMB BRIGHTENING AT RADIO, MILLIMETER, SUB-MILLIMETER, AND INFRARED WAVELENGTHS

Observations of the emission at radio, millimeter, sub-millimeter, and infrared wavelengths in the center of the solar disk validate the autoconsistence of semi-empirical models of the chromosphere. Theoretically, these models must reproduce the emission at the solar limb. In this work, we tested both the VALC and C7 semi-empirical models by computing their emission spectrum in the frequency range from 2 GHz to 10 THz at solar limb altitudes. We calculate the Sun's theoretical radii as well as their limb brightening. Non-local thermodynamic equilibrium was computed for hydrogen, electron density, and H{sup −}. In order to solve the radiative transfer equation, a three-dimensional (3D) geometry was employed to determine the ray paths, and Bremsstrahlung, H{sup −}, and inverse Bremsstrahlung opacity sources were integrated in the optical depth. We compared the computed solar radii with high-resolution observations at the limb obtained by Clark. We found that there are differences between the observed and computed solar radii of 12,000 km at 20 GHz, 5000 km at 100 GHz, and 1000 km at 3 THz for both semi-empirical models. A difference of 8000 km in the solar radii was found when comparing our results against the heights obtained from H α observations of spicules-off at the solar limb. We conclude that the solar radii cannot be reproduced by VALC and C7 semi-empirical models at radio—infrared wavelengths. Therefore, the structures in the high chromosphere provide a better measurement of the solar radii and their limb brightening as shown in previous investigations.

79 ASTRONOMY AND ASTROPHYSICS↗

Photocathode

A photocathode designs that leverage the grazing incidence geometry yield improvements through the introduction of recessed structures, such as cones, pyramids, pillars or cavities to the photocathode substrate surface. Improvements in yield of up to 20 times have been shown to occur in grazing incidence geometry disclosed herein due to a larger path length of the X-ray photons which better matches the secondary electron escape depth within the photocathode material. A photocathode includes a substrate having a first side and a second side, the first side configured to receive x-ray energy and the second side opposing the first side. A structured surface is associated with the second side of the substrate such that the structured surface includes a plurality of recesses from the second side of the substrate into the substrate.

36 MATERIALS SCIENCE↗

Grazing exit versus grazing incidence geometry for x-ray absorption near edge structure analysis of arsenic traces

In the presented study the grazing exit x-ray fluorescence was tested for its applicability to x-ray absorption near edge structure analysis of arsenic in droplet samples. The experimental results have been compared to the findings of former analyses of the same samples using a grazing incidence (GI) setup to compare the performance of both geometries. Furthermore, the investigations were accomplished to gain a better understanding of the so called self-absorption effect, which was observed and investigated in previous studies using a GI geometry. It was suggested that a normal incidence-grazing-exit geometry would not suffer from self-absorption effects in x-ray absorption fine structure (XAFS) analysis due to the minimized path length of the incident beam through the sample. The results proved this assumption and in turn confirmed the occurrence of the self-absorption effect for GI geometry. Due to its lower sensitivity it is difficult to apply the GE geometry to XAFS analysis of trace amounts (few nanograms) of samples but the technique is well suited for the analysis of small amounts of concentrated samples.

36 MATERIALS SCIENCE↗

Whistlers, helicons, and lower hybrid waves: The physics of radio frequency wave propagation and absorption for current drive via Landau damping

This introductory-level tutorial article describes the application of plasma waves in the lower hybrid range of frequencies (LHRF) for current drive in tokamaks. Wave damping mechanisms in a nearly collisionless hot magnetized plasma are briefly described, and the connections between the properties of the damping mechanisms and the optimal choices of wave properties (mode, frequency, wavelength) are explored. The two wave modes available for current drive in the LHRF are described and compared. The terms applied to these waves in different applications of plasma physics are elucidated. The character of the ray paths of these waves in the LHRF is illustrated in slab and toroidal geometries. Applications of these ideas to experiments in the DIII-D tokamak are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantification of spatial and seasonal trends in the atmosphere and construction of statistical models for infrasonic propagation

SUMMARY Infrasonic waves are influenced by variations in the density, pressure and temperature as well as the ambient winds. Modelling infrasonic propagation can be challenging due to the dynamic nature of the atmosphere as well as the sparseness of measurements which result in variability and notable uncertainty. A framework is presented to quantify spatial and seasonal trends in atmospheric structure via analysis of the effective sound speed profile and identification of temporal trends in the middle atmospheric waveguide produced by the circumpolar vortex winds. Seasonal definitions identifying typical atmospheric structures during the summer, winter and spring/fall transition periods are identified using atmospheric data from 2010 through 2020. Seasonal trend analysis is conducted for a number of locations across the contiguous United States to quantify spatial variations in atmospheric structure that impact infrasonic propagation. For each season and location, empirical orthogonal function analysis is used to reduce the historical archive of atmospheric data into a smaller representative set that can be analysed using numerical tools more efficiently. Infrasonic ray tracing and finite-frequency modal propagation analyses are applied to construct propagation path geometry and transmission loss statistics which are useful in localization and yield estimation for infrasonic sources, respectively. An example application is detailed in which transmission loss statistics are combined with an explosive source model and noise statistics to quantify the capability of a network to detect nearby sources.

58 GEOSCIENCES↗

In-Situ Visualization of a Growing Brittle Crack in Aluminum Oxynitride Using Synchrotron X-Rays and the Double-Cleavage Drilled Compression Geometry

Brittle fracture is difficult to study in situ due to the speed of a growing crack and the often-catastrophic nature of failure in brittle materials. As a result, the influence of microstructural considerations, such as orientation, grain boundary locations, and strain field, on the crack path remains poorly understood. Presented in this study is a method addressing this knowledge gap, which utilizes the double-cleavage drilled compression geometry to achieve quasi-stable fracture in aluminum oxynitride (AlON). Synchrotron X-ray micro-computed tomography is used to characterize the crack shape and length, while high-energy diffraction microscopy provides information on the strains, orientations, and shapes of grains in the microstructure surrounding the crack tip. During testing, the crack grew in discrete and irregular jumps while the fracture toughness falls within reported ranges. The crack in AlON is found to have no greater tendency to crack intergranularly as compared to transgranularly, and grains which are cracked transgranularly do not display a trend in orientation or stress when compared to those around which the crack followed a grain boundary. The high resolution of the crack path and microstructural data provides a path forward for modeling and understanding 3D brittle fracture.

Gorske, Sara F.↗

X-ray scattered halo around IGR J17544–2619

X-ray photons coming from an X-ray point source not only arrive at the detector directly, but also can be strongly forward-scattered by the interstellar dust along the line of sight (LOS), leading to a detectable diffuse halo around the X-ray point source. The geometry of small-angle X-ray scattering is straightforward, namely, the scattered photons travel longer paths and thus arrive later than the unscattered ones; thus, the delay time of X-ray scattered halo photons can reveal information of the distances of the interstellar dust and the point source. Here we present a study of the X-ray scattered halo around IGR J17544–2619, which is one of the so-called supergiant fast X-ray transients. IGR J17544–2619 underwent a striking outburst when observed with Chandra on 2004 July 3, providing a near δ-function light curve. We find that the X-ray scattered halo around IGR J17544–2619 is produced by two interstellar dust clouds along the LOS. The one that is closer to the observer gives the X-ray scattered halo at larger observational angles, whereas the farther one, which is in the vicinity of the point source, explains the halo with a smaller angular size. By comparing the observational angle of the scattered halo photons with that predicted by different dust grain models, we are able to determine the normalized dust distance. With the delay times of the scattered halo photons, we can determine the point source distance, given a dust grain model. Alternatively, we can discriminate between the dust grain models, if the point source distance is known independently.

79 ASTRONOMY AND ASTROPHYSICS↗

The effects of structure anisotropy on lensing observables in an exact general relativistic setting for precision cosmology

The study of relativistic, higher order, and nonlinear effects has become necessary in recent years in the pursuit of precision cosmology. We develop and apply here a framework to study gravitational lensing in exact models in general relativity that are not restricted to homogeneity and isotropy, and where full nonlinearity and relativistic effects are thus naturally included. We apply the framework to a specific, anisotropic galaxy cluster model which is based on a modified NFW halo density profile and described by the Szekeres metric. We examine the effects of increasing levels of anisotropy in the galaxy cluster on lensing observables like the convergence and shear for various lensing geometries, finding a strong nonlinear response in both the convergence and shear for rays passing through anisotropic regions of the cluster. Deviation from the expected values in a spherically symmetric structure are asymmetric with respect to path direction and thus will persist as a statistical effect when averaged over some ensemble of such clusters. The resulting relative difference in various geometries can be as large as approximately 2%, 8%, and 24% in the measure of convergence (1−κ) for levels of anisotropy of 5%, 10%, and 15%, respectively, as a fraction of total cluster mass. For the total magnitude of shear, the relative difference can grow near the center of the structure to be as large as 15%, 32%, and 44% for the same levels of anisotropy, averaged over the two extreme geometries. The convergence is impacted most strongly for rays which pass in directions along the axis of maximum dipole anisotropy in the structure, while the shear is most strongly impacted for rays which pass in directions orthogonal to this axis, as expected. The rich features found in the lensing signal due to anisotropic substructure are nearly entirely lost when one treats the cluster in the traditional FLRW lensing framework. These effects due to anisotropic structures are thus likely to impact lensing measurements and must be fully examined in an era of precision cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ electrochemical high-energy X-ray diffraction using a capillary working electrode cell geometry

The ability to generate new electrochemically active materials for energy generation and storage with improved properties will likely be derived from an understanding of atomic-scale structure/function relationships during electrochemical events. Here, the design and implementation of a new capillary electrochemical cell designed specifically for in situ high-energy X-ray diffraction measurements is described. By increasing the amount of electrochemically active material in the X-ray path while implementing low- Z cell materials with anisotropic scattering profiles, an order of magnitude enhancement in diffracted X-ray signal over traditional cell geometries for multiple electrochemically active materials is demonstrated. This signal improvement is crucial for high-energy X-ray diffraction measurements and subsequent Fourier transformation into atomic pair distribution functions for atomic-scale structural analysis. As an example, clear structural changes in LiCoO 2 under reductive and oxidative conditions using the capillary cell are demonstrated, which agree with prior studies. Accurate modeling of the LiCoO 2 diffraction data using reverse Monte Carlo simulations further verifies accurate background subtraction and strong signal from the electrochemically active material, enabled by the capillary working electrode geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ X-ray imaging of heterogeneity in dynamic compaction of granular media

Dynamic compaction of granular materials is a complex process wherein the material response at the continuum scale arises from fracture, comminution, and fragment ow at the grain scale. Granular materials have heterogeneity due to variation in grain properties, as well as variation in local packing density and structure. These heterogeneities may affect the dynamic compaction response, producing a structured and time-varying compaction front. Methodology used to characterize the shock behavior in solid materials may be inappropriate for granular materials, because of this unsteady behavior and interactions between the granular material and measurement surfaces. To observe the compaction front heterogeneity, in-situ x-ray imaging of granular compaction is conducted at a scale between the grain- and continuum scales. To allow for sufficient x-ray transmission, a thin sample geometry is used, for which boundary affects may result in a significantly different load path than would occur in a 1-D compaction configuration. Numerical simulations of the experimental geometry support analysis of the results so that the feature of the compaction front can be distinguished from artifacts of the experimental configuration. The results suggest compaction front heterogeneity may have structure with a length scale of tens of particle diameters, and demonstrate that finite grain size can inhibit the formation shear-induced features that would arise in a homogenized representation of the same material.

36 MATERIALS SCIENCE↗

Metrics for Developing an Endorsed Set of Radiographic Threat Surrogates for JINII/CAARS

CAARS (Cargo Advanced Automated Radiography System) is developing x-ray dual energy and x-ray backscatter methods to automatically detect materials that are greater than Z=72 (hafnium). This works well for simple geometry materials, where most of the radiographic path is through one material. However, this is usually not the case. Instead, the radiographic path includes many materials of different lengths. Single energy can be used to compute {mu}y{sub l} which is related to areal density (mass per unit area) while dual energy yields more information. This report describes a set of metrics suitable and sufficient for characterizing the appearance of assemblies as detected by x-ray radiographic imaging systems, such as those being tested by Joint Integrated Non-Intrusive Inspection (JINII) or developed under CAARS. These metrics will be simulated both for threat assemblies and surrogate threat assemblies (such as are found in Roney et al. 2007) using geometrical and compositional information of the assemblies. The imaging systems are intended to distinguish assemblies containing high-Z material from those containing low-Z material, regardless of thickness, density, or compounds and mixtures. The systems in question operate on the principle of comparing images obtained by using two different x-ray end-point energies--so-called 'dual energy' imaging systems. At the direction of the DHS JINII sponsor, this report does not cover metrics that implement scattering, in the form of either forward-scattered radiation or high-Z detection systems operating on the principle of backscatter detection. Such methods and effects will be covered in a later report. The metrics described here are to be used to compare assemblies and not x-ray radiography systems. We intend to use these metrics to determine whether two assemblies do or do not look the same. We are tasked to develop a set of assemblies whose appearance using this class of detection systems is indistinguishable from the real threats. To check such an indistinguishability, we must define metrics that are broad enough to cover systems of different source spectra and detector spectral response; in other words, the best metrics should capture physical properties of the assemblies and not the source and detectors employed. In fact, one requirement for the metrics is that, as the detection circumstances change, the similarity or difference of the metrics of two assemblies should be maintained. This report describes the set of two simple 'dual energy' metrics that we have selected. A second report (Wurtz, et al. 2009) goes on to demonstrate several characteristics of the metrics, including how sensitive they are (or are not) to changes in the detection systems, shielding, etc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-energy differential-filtering photon spectrometer for ultraintense laser-matter interactions

Large quantities of ultrahigh-energy x-rays are produced by petawatt-class lasers; however, spectroscopy in this range of 0.1-1 MeV is difficult due to the long photon mean free path. A novel geometry step filter to measure the high-energy bremsstrahlung emission tail has been developed for use in high energy density, short-pulse laser-matter interaction experiments. The grid design of the filters allows for the independent determination of a local background, which reduces systematic errors in the reconstructed spectra. This spectrometer was used to measure x-ray spectra for various laser and target conditions at intensities near 1 × 10 18 W/cm 2 where single-exponential bremsstrahlung spectra were fit to the data and show an increasing photon temperature with pulse duration for a fixed laser intensity.

47 OTHER INSTRUMENTATION↗

Extended Defects in Cdznte Radiation Detectors

Large-volume CdZnTe (CZT) single crystals with electron lifetime exceeding 10 mus have recently become commercially available. This opened the opportunity for making room temperature CZT gamma-ray detectors with extended thicknesses and larger effective areas. However, the extended defects that are present even in the highest-quality material remain a major drawback which affects the availability and cost of large CZT detectors. In contrast to the point defects that control electron lifetime and whose effects on the charge collection can be electronically corrected, the extended defects introduce significant fluctuations in the collected charge, which increase with a crystal's thickness. The extended defects limit the uniformity in the electrons' drift distance in CZT crystals, above which electron trapping cannot effectively be corrected. In this paper, we illustrate the roles of the extended defects in CZT detectors with different geometries. We emphasize that the crystallinity of commercial CZT materials remains a major obstacle on the path to developing thick, large-volume CZT detectors for gamma-ray imaging and spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the beam path deflection for a vertically installed microwave interferometer in SUNIST

Microwave interferometry has been widely employed to provide reliable line averaged electron density measurement on plasma devices. For a vertically installed interferometer on a tokamak, the refraction problem, which distorts the beam path and aggravates power loss at the receiving antenna, may become significant if taking the cross section shape into account. Increasing the frequency of the probing microwave can alleviate the distortion, but at the expense of losing the density resolution. To seek for an optimized frequency, previous calculations are mainly based on the cylindrical column geometry which grossly underestimates the deflection of the beam path induced by the plasma shape, and empirical suggestions indicating n{sub e0}/n{sub c} = 1/2 ∼ 1/3 may not always be the appropriate option. Here a single ray tracing method is applied to estimate the final horizontal deviation at the receiving antenna, which is supposed to represent the level of power loss. The calculation is carried out under the real tokamak geometry in Sino-UNIted Spherical Tokamak (SUNIST) with the cross section parameters obtained from the equilibrium reconstruction, and the result indicates that for a target density of 1.2 × 10{sup 19} m{sup −3}, a frequency of at least 100 GHz is desirable to reduce the power loss to an acceptable level. This would be helpful for the design of a vertically installed interferometer on SUNIST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗