Search NASA⌕ Search

SEARCH · Search NASA

Results for “recession sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Ion-temperature determination with a baffled Langmuir probe

An electrostatic Langmuir probe for real-time measurements of parameters in magnetized plasma is tested in fully ionized, barium, Q-machine plasma. The small-diameter, long-length, tungsten wire sensor, i.e., the probe tip, oriented with its cylindrical axis perpendicular to the magnetic field (B), is partially shielded by ceramic baffles, or masks, that form sensor-access slots between the baffles. Adjusting the azimuthal orientation of the slots, by rotating the probe about its cylindrical axis, changes the fraction of proximity gyro-orbiting electrons, relative to the fraction of proximity gyro-orbiting ions, that can access the recessed sensor along the magnetic field. Thus, the ratio between the electron and ion saturation currents, $I^{sat}_e$ and $I^{sat}_i$, can be adjusted without having affected the probe bias voltage V b . When optimally shielded ($I^{sat}_e/I^{sat}_i$=1), accurate, real-time measurements of space potential Vs can be acquired. When maximally shielded ($I^{sat}_e/I^{sat}_i$ << 1), accurate, real-time measurements of ion temperature T i can be acquired. Subtracting the floating potential V f of an optimally shielded baffled probe from V f of a maximally shielded baffled probe yields T i (and its fluctuation phase) in real time.

47 OTHER INSTRUMENTATION↗

Transducer Installation Effects on Pressure Measurements in PGC Devices

Pressure gain devices such as rotating detonation engines present an extremely harsh environment, generally precluding the use of any intrusive probe measurement. The most widely used diagnostic is the measurement of high frequency pressure which can be used to determine the pressure amplitude, number of waves and their direction and the wave structure. The preferred approach for making pressure measurements is to install the sensing element flush with the combustion chamber wall, but is almost always inhibited by the extremely high heat fluxes that can damage the sensor. Alternately, recessed cavity or infinite probe installation is seldom used for high frequency pressure measurements. While amplitude attenuation and phase distortion of the pressure signal can be introduced by these installation types, its characterization in the presence of high amplitude steep fronted pressure waves encountered in PGC devices has not been previously performed. In the current work a highly modular calibration test-bed is designed to enable characterization of pressure transducers based on their installation in the presence of steep fronted high amplitude pressure waves. Two transducer types, piezoelectric PCB® 113B26 and water-cooled piezoresistive Kulite®WCT-312M were used and installed in the flush, recessed cavity and infinite tube probe configuration. The recessed cavity probe showed 5-26% amplitude attenuation and almost negligible time lag compared to the flush transducer, the infinite tube pressure (ITP) transducer showed a significantly higher delay and as much as 50% reduction in measured pressure amplitude. Secondary wave features from reflections within the test article, that were captured by the flush and recessed cavity transducer were damped by the infinite probe measurement.

20 FOSSIL-FUELED POWER PLANTS↗

The Influence of Communication on the Complexity of Connected Lighting Systems

Experience in the Next Generation Lighting Systems (NGLS) ”Living Lab” at the Parsons School of Design, has clearly shown the impacts of communication on the configuration complexity of the connected lighting systems installed there. Since 2017, NGLS has invited manufacturers to submit connected lighting systems for assessment against a set of specifications. To date, 14 systems of wirelessly connected LED luminaires and controls have been installed in classrooms with existing lighting. In nine of the rooms, new LED linear pendants or recessed troffers replaced existing luminaires; in the other rooms, LED “kits” were retrofitted into the existing troffers. Eleven of the installations featured sensors integrated in the luminaires or retrofit kits; the others used ceiling mounted sensors. All systems provided wall control devices for manual operation. For half of the installations, the complete systems were furnished by single companies; for the other half, luminaires and controls were furnished by separate companies. A total of 18 different companies provided products, with four of these located outside the United States including, Korea, Poland, Germany, and the Netherlands. In addition, two different electrical contractors in New York City provided multiple installation teams totaling 10 individuals, none of whom were familiar with any of the systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Silencing of U.S. Campuses Following the COVID-19 Response: Evaluating Root Mean Square Seismic Amplitudes Using Power Spectral Density Data

In response to the COVID-19 global pandemic, many populated and active regions have become deserted and show significant reductions in their background seismicity, especially campuses across the United States (U.S.). Seismic sensors located in the vicinity of or within U.S. campuses show that anthropogenic seismic noise remains elevated during the ordinary, nonpandemic, academic year, only subduing during periods of recess (e.g., winter break). Here, we use power spectral density (PSD) data computed by the Incorporated Research Institutions for Seismology Data Management Center for quality assessment to calculate root mean square (rms) amplitude and analyze the effects of the COVID-19 school closures. We processed and analyzed PSD data for 46 seismic stations located within 50 m of a U.S. university or college. Results show that 42 campus stations show an overall rms drop following a statewide school closure.

58 GEOSCIENCES↗

Dimerization-dependent serine protease activity of FAM111A prevents replication fork stalling at topoisomerase 1 cleavage complexes

FAM111A, a serine protease, plays roles in DNA replication and antiviral defense. Missense mutations in the catalytic domain cause hyper-autocleavage and are associated with genetic disorders with developmental defects. Despite the enzyme’s biological significance, the molecular architecture of the FAM111A serine protease domain (SPD) is unknown. Here, we show that FAM111A is a dimerization-dependent protease containing a narrow, recessed active site that cleaves substrates with a chymotrypsin-like specificity. X-ray crystal structures and mutagenesis studies reveal that FAM111A dimerizes via the N-terminal helix within the SPD. This dimerization induces an activation cascade from the dimerization sensor loop to the oxyanion hole through disorder-to-order transitions. Dimerization is essential for proteolytic activity in vitro and for facilitating DNA replication at DNA-protein crosslink obstacles in cells, while it is dispensable for autocleavage. These findings underscore the role of dimerization in FAM111A’s function and highlight the distinction in its dimerization dependency between substrate cleavage and autocleavage.

59 BASIC BIOLOGICAL SCIENCES↗