Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pulse-Echo Ultrasonic Imaging Method for Eliminating Sample Thickness Variation Effects

A pulse-echo, immersion method for ultrasonic evaluation of a material which accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer and automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjustments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.

Roth, Don J.↗

Pulse-echo ultrasonic imaging method for eliminating sample thickness variation effects

A pulse-echo, immersion method for ultrasonic evaluation of a material is discussed. It accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer, automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjusments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.

Roth, Don J.↗

A technique to correct for sample thickness variations for use with IDAPS X-ray radiograph analysis

The Image Data Processing System (IDAPS) at the Marshall Space Flight Center is used to analyze radiographs of metal samples to qualitatively and quantitatively map compositional variations across the samples. When the X-ray radiographs are of samples having thickness variations, corrections must be made to accomplish compositional analysis. A correction technique is described for cylindrical samples and is applied to radiographs of SPAR Experiment 74-18. Uncorrected and corrected images are shown.

Schafer, C. F.↗

Vehicle Modeling During the Burning of Thermally Thick Samples in the Saffire V Experiments

In order to design a safer spacecraft in terms of fire prevention, detection and cleanup, the transport of combustion products and heat must be predicted. Large-scale fire data was provided by the Saffire payload within Northrup Grumman’s Cygnus vehicle after a resupply mission to the ISS. Solid materials, including thick thermoplastic samples were ignited to study flame spread and the effect a fire has on a vehicle. Sensors that measured species and temperature were placed within Cygnus. A model using Pyrosim was developed to predict the thick fuel burn events from Saffire V by using sensor data from Cygnus. The heat transfer coefficient between the cabin air and cargo was previously calibrated using the cotton fuel burn event, and provided a good prediction of the temperature response within the vehicle during the two thick fuel experiments. The difference between the Saffire inlet CO 2 sensor, and the forward port standoff CO 2 sensor, which is the closest to the Saffire outlet, was used as an input into the model. This method provided an excellent prediction of the CO 2 response in the other parts of the Cygnus.

fire safety↗

Temperature-dependent transmission and self-indication measurements upon depleted U in the unresolved region

Neutron transmission and self-indication ratio measurements have been carried out at the RPI LINAC on depleted U up to 100 KeV in order to investigate the temperature dependence of resonance self-shielding. These measurements were performed at three sample temperatures (77 deg k, 295 deg k, and 973 deg k) and with sample thicknesses ranging from 0.0076 to 0.0621 atom/barn. Both stochastic sampling and analytical methods have been used to interpret these data. Average resonance parameters have been obtained and temperature dependence as well as sample thickness dependence of the data have been extensively studied.

Byoun, T. Y.↗

The role of geological surfaces in determining visible-near infra red spectral signatures

The goal of the study described here is to determine new criteria for improved target discrimination in areas of hydrothermal mineralization. It is noted that the portion of materials, that is, geological surfaces detected by sensing devices, must be accurately determined before elemental and mineralogical characterization. The depth from which visible-near infrared radiation is reflected from target surfaces depends on composition and fabric. Reflectance spectra are obtained from binary mixtures of hematite, goethite, kaolinite and montmorillonite with a reflecting sphere spectrometer over a wavelength range of 400-2500 nm. The reflection (or absorption) intensity is plotted vs. the sample thickness (determined by scanning electron microscopy) to determine the sample thickness at which absorption saturates. The optical depth is seen to vary as a function of mineralogy and wavelength. In general, the maximum depth from which reflection features are discerned is from 12 to 47 microns measured in the visible-near infrared spectral region.

Sommer, S. E.↗

Dielectric function of InGaAs in the visible

Measurements are reported of the dielectric function of thermodynamically stable In(x)Ga(1-x)As in the composition range 0.3 equal to or less than X = to or less than 0.7. The optically thick samples of InGaAs were made by molecular beam epitaxy (MBE) in the range 0.4 = to or less than X = to or less than 0.7 and by metal-organic chemical vapor deposition (MOCVD) for X = 0.3. The MBE made samples, usually 1 micron thick, were grown on semi-insulating InP and included a strain release structure. The MOCVD sample was grown on GaAs and was 2 microns thick. The dielectric functions were measured by variable angle spectroscopic ellipsometry in the range 1.55 to 4.4 eV. The data was analyzed assuming an optically thick InGaAs material with an oxide layer on top. The thickness of this layer was estimated by comparing the results for the InP lattice matched material, i.e., X = 0.53, with results published in the literature. The top oxide layer mathematically for X = 0.3 and X = 0.53 was removed to get the dielectric function of the bare InGaAs. In addition, the dielectric function of GaAs in vacuum, after a protective arsenic layer was removed. The dielectric functions for X = 0, 0.3, and 0.53 together with the X = 1 result from the literature to evaluate an algorithm for calculating the dielectric function of InGaAs for an arbitrary value of X(0 = to or less than X = to or less than 1) were used. Results of the dielectric function calculated using the algorithm were compared with experimental data.

Alterovitz, S. A.↗

Dielectric function of InGaAs in the visible

Measurements are reported of the dielectric function of thermodynamically stable In(x)Ga(1-x)As in the composition range 0.3 equal to or less than X = to or less than 0.7. The optically thick samples of InGaAs were made by molecular beam epitaxy (MBE) in the range 0.4 = to or less than X = to or less than 0.7 and by metal-organic chemical vapor deposition (MOCVD) for X = 0.3. The MBE made samples, usually 1 micron thick, were grown on semi-insulating InP and included a strain release structure. The MOCVD sample was grown on GaAs and was 2 microns thick. The dielectric functions were measured by variable angle spectroscopic ellipsometry in the range 1.55 to 4.4 eV. The data was analyzed assuming an optically thick InGaAs material with an oxide layer on top. The thickness of this layer was estimated by comparing the results for the InP lattice matched material, i.e., X = 0.53, with results published in the literature. The top oxide layer mathematically for X = 0.3 and X = 0.53 was removed to get the dielectric function of the bare InGaAs. In addition, the dielectric function of GaAs in vacuum, after a protective arsenic layer was removed. The dielectric functions for X = 0, 0.3, and 0.53 together with the X = 1 result from the literature to evaluate an algorithm for calculating the dielectric function of InGaAs for an arbitrary value of X (0 = to or less than X = to or less than 1) were used. Results of the dielectric function calculated using the algorithm were compared with experimental data.

Alterovitz, S. A.↗

Infrared band extinctions and complex refractive indices of crystalline C2H2 and C4H2

Thermal IR absorption intensities are obtained for thin films of crystalline C2H2 and C4H2 at 70 K, and their n and k complex refractive indices are ascertained by separating true film absorption from interface reflection on the basis of an analysis of the transmission spectrum ratio for two sample thicknesses. This method significantly simplifies the n and k iteration process. The n and k values determined in the laboratory will in most cases reproduce a given sample thickness' observed transmission to within + or - 5 percent.

Khanna, R. K.↗

Pyrolysis Rate and Yield Strength Reduction Incarbon Fiber and Glass Fiber Composites Underreentry Heating Conditions

The behavior of composite materials, specifically carbon fiber reinforced plastic (CFRP) and glass fiber reinforced plastic (GFRP), under reentry conditions poses a problem for space debris reentry risk modeling. Since these materials pyrolyze rather than melt and their different components demise at different rates, modeling their destruction to determine ground impact risk is complex. Modern spacecraft are using these materials in ever-greater quantities owing to their superior strength-to-weight characteristics, and this has required that the orbital debris community improve its understanding of how these materials demise on reentry. The NASA Orbital Debris Program Office undertook an extensive test campaign to better understand the rate at which several types of GFRP and CFRP materials pyrolyze under reentry heating conditions and how that pyrolysis affects the ultimate strength of the material. GFRP with a polyester resin (G10/FR-4) and CFRP with epoxy, cyanate ester, vinyl ester, and phenolic resins were tested. The test campaign was carried out at the Inductively Coupled Plasma (ICP) Torch Facility at the University of Texas at Austin. Because the ICP facility operates in a shirt-sleeve environment, test samples can be changed within seconds or minutes, allowing many samples to be tested in a short period. Two heat flux rates, 20 W/m2 and 30W/m2, and two oxygen concentration conditions, 0% and 2% of atmospheric, were applied to all five types of material. To measure both the char rate and the effect of pyrolysis on the ultimate material strength, two types of test were carried out for each material: a char rate test on a ~10 mm thick sample of material and an in-situ bending stress test of a ~2 mm thick sample of material. Measurements of the char rate showed very similar average pyrolysis front velocity in epoxy resin CFRP as in G10 at 3.6 mm/min and 3.4 mm/min, respectively. However, the total mass loss rate in theG10 was nearly double that of the CFRP at 3.8 g/min and 2.2 g/min, respectively. This result represented a slow ablation rate of carbon fibers in the CFRP at the temperatures encountered in low Earth orbit reentry and a comparatively rapid removal of the glass fibers in G10 due to melting and spallation. Pyrolysis front velocity was more significantly affected by the type of plastic than the type of fiber, with the cyanate ester CFRP samples displaying an average pyrolysis front velocity of only 1.9 mm/min. Similarly, the effect of thermal exposure on the ultimate strength of the material depended heavily on the type of plastic and very little on the type of fiber in the material. Epoxy, vinyl ester, and polyester resins all behaved very similarly, with complete structural failure at between 400 J/g and 600 J/g of specific absorbed heat. Phenolic and cyanate ester resins, on the other hand, displayed a change in structural properties that was only barely measurable with the current apparatus even after the maximum exposure time tested. These data are being incorporated into a numerical model of the ablation and demise of composite materials that will be used to more accurately calculate the ground casualty risk of future spacecraft.

Benton R. Greene↗

Precision Thickness Variation Mapping via One-Transducer Ultrasonic High Resolution Profilometry for Sample with Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.↗

Precision Thickness Variation Mapping Via One-Transducer Ultrasonic High Resolution Profilometry for Sample With Irregular or Rough Surface

An apparatus and method for determination of sample thickness and surface depression utilizing ultrasonic pulses is discussed. The sample is held in a predetermined position by a support member having a reference surface. Ultrasonic pulses travel through a medium of known velocity propagation and reflect off the reference surface and a sample surface. Time of flight data of surface echoes are converted to distances between sample surfaces to obtain computer-generated thickness profiles and surface mappings.

Roth, Don J.↗

A simple model of electron beam initiated dielectric breakdown

A steady state model that describes the internal charge distribution of a planar dielectric sample exposed to a uniform electron beam was developed. The model includes the effects of charge deposition and ionization of the beam, separate trap-modulated mobilities for electrons and holes, electron-hole recombination, and pair production by drifting thermal electrons. If the incident beam current is greater than a certain critical value (which depends on sample thickness as well as other sample properties), the steady state solution is non-physical.

Beers, B. L.↗

Effects of orbital exposure on Halar during the LDEF mission

Thermomechanical Analysis (TMA), Differential Scanning Calorimetry (DSC), and Thermogravimetric Analysis (TGA) were performed on samples of Halar exposed on the LDEF Mission for 6 years in orbit and unexposed Halar control samples. Sections 10-100 microns thick were removed from the exposed surface down to a depth of 1,000 microns through the 3 mm thick samples. The TMA and DSC results, which arise from the entire slice and not just its surface, showed no differences between the LDEF and the control samples. TMA scans were run from ambient to 300 C; results were compared by a tabulation of the glass transition temperatures. DSC scans were run from ambient to 700 C; the enthalpy of melting was compared for the samples as a function of section depth with the sample. The TGA results, which arise from the surface of the sample initially, showed a sharp increase in the topmost 50 micron section (the exposed, discolored side) in the weight loss of 170 C in oxygen. This weight loss dropped to bulk values in the range of depth of 50-200 microns. The control sample showed only a slight increase in weight loss as the top surface was approached. The LDEF Halar sample appears to be mechanically undamaged, with a surface layer which oxidizes faster as a result of orbital exposure.

Brower, William E., Jr.↗

Halide eutectic growth experiment MA-131

Fiberlike sodium chloride/lithium fluoride eutectic mixtures have been produced on earth and in space by the directional solidification technique. Macroscopic and microscopic examinations were made on longitudinal and transverse sections of Apollo Soyuz Test Project space grown and earth grown ingots. It was found that samples grown in space have a higher percentage of fibers alined with the growth axis. The enhanced alinement of fibers is attributed to the absence of convection currents in the liquid during solidification. Optical transmittance measurements of transverse sections of the space grown and earth grown ingots were performed with an infrared spectrometer. For a given sample thickness, the highest transmittance was obtained from ingots grown in space. For samples of different thicknesses, grown either in space or on earth, it was found that the thinner the sample, the higher the transmittance. This is in agreement with the general optical property of transparent materials.

Yue, A. S.↗

Effects of orbital exposure on RTV during the LDEF mission

Thermomechanical analysis (TMA), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA) were performed on samples of RTV 511 exposed on the Long Duration Exposure Facility (LDEF) mission for 6 years in orbit and unexposed RTV 511 control samples. Slices 20- to 400-microns thick were removed from the exposed surface down to a depth of 1,500 microns through the 3-mm thick samples. The TMA and DSC results, which arise from the entire slice and not just its surface, showed no significant differences between the LDEF exposed and the control samples. TMA scans were run from ambient to 500 C; results were compared by a tabulation of the onset temperatures for flow. DSC scans were run from ambient to 600 C; no endotherms or exotherms occurred over the range observed. What appear to be glass transition temperatures were compared for the samples as a function of section depth within the sample and between the exposed and control samples. The TGA scans from 25 to 900 C, which arise from the surface of the sample initially, showed a slight increase in the top most 105-micron slice (the exposed, discolored side) in the weight loss at 600 C in oxygen. This weight loss dropped to bulk values at the next slice below the top section, a mean depth of 258 microns. The control sample also showed an increase in weight loss as the top surface was approached, but the 600 C weight losses were very inconsistent. The LDEF RTV sample appears to be mechanically undamaged, with a surface layer which oxidizes slightly faster as a result of orbital exposure.

Brower, William E., Jr.↗

Solid Surface Combustion at Reduced Gravity

The spread of a flame in the gas over the surface of a solid combustible involves in an essential way the transfer of heat from the flame to the solid fuel immediately ahead of it. This heat transfer is affected by the character of the gas phase flame, and so the phenomenon of flame spreading under reduced gravity, in which the flow is generated by gasification of the solid combustible, is apt to be different from what occurs under the Earth's normal gravitational acceleration where the flow is largely buoyancy driven. An experiment is being designed for the Middeck of the Space Shuttle to aid us in understanding the process of flame spreading in the absence of a buoyancy driven flow. A chamber approximately 0.35 cu.m. in volume is to contain either a thin sample of a cellulosic material or a thick sample of polymethyl-methacrylate and an oxidizing environment of O2 and N2. Samples will be ignited at one end, and the ensuing flame spread will be filmed. The spread rate can be determined from the films, and surface and gas-phase temperatures just above the surface will also be recorded. These data will help to clarify the mechanism of forward heat transfer in the low gravity flames.

Altenkirch, R. A.↗