Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pulmonary lobe segmentation based on ridge surface sampling and shape model fitting

Purpose: Performing lobe-based quantitative analysis of the lung in computed tomography (CT) scans can assist in efforts to better characterize complex diseases such as chronic obstructive pulmonary disease (COPD). While airways and vessels can help to indicate the location of lobe boundaries, segmentations of these structures are not always available, so methods to define the lobes in the absence of these structures are desirable. Methods: The authors present a fully automatic lung lobe segmentation algorithm that is effective in volumetric inspiratory and expiratory computed tomography (CT) datasets. The authors rely on ridge surface image features indicating fissure locations and a novel approach to modeling shape variation in the surfaces defining the lobe boundaries. The authors employ a particle system that efficiently samples ridge surfaces in the image domain and provides a set of candidate fissure locations based on the Hessian matrix. Following this, lobe boundary shape models generated from principal component analysis (PCA) are fit to the particles data to discriminate between fissure and nonfissure candidates. The resulting set of particle points are used to fit thin plate spline (TPS) interpolating surfaces to form the final boundaries between the lung lobes. Results: The authors tested algorithm performance on 50 inspiratory and 50 expiratory CT scans taken from the COPDGene study. Results indicate that the authors' algorithm performs comparably to pulmonologist-generated lung lobe segmentations and can produce good results in cases with accessory fissures, incomplete fissures, advanced emphysema, and low dose acquisition protocols. Dice scores indicate that only 29 out of 500 (5.85%) lobes showed Dice scores lower than 0.9. Two different approaches for evaluating lobe boundary surface discrepancies were applied and indicate that algorithm boundary identification is most accurate in the vicinity of fissures detectable on CT. Conclusions: The proposed algorithm is effective for lung lobe segmentation in absence of auxiliary structures such as vessels and airways. The most challenging cases are those with mostly incomplete, absent, or near-absent fissures and in cases with poorly revealed fissures due to high image noise. However, the authors observe good performance even in the majority of these cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bennu Shape Model Validation Methods and Results

The OSIRIS-REx Independent Shape Modeling Team, staffed by the Jet Propulsion Laboratory (JPL), has used stereophotoclinometry (SPC) to produce a three-dimensional shape model of Bennu. The SPC process is informed by (but is separate from) orbit determination, so it is important to ensure that the resulting shape model is consistent with all available spacecraft tracking data. Specifically, checking the shape model’s consistency with LIDAR measurements can illuminate any discrepancies, because LIDAR measurements are highly correlated with the shape model. This study focuses on the JPL experience with these LIDAR measurements and the greater context of the shape model validation process.

Lauretta, Dante S.↗

Thermophysical Modeling of Asteroid Surfaces Using Ellipsoid Shape Models

Thermophysical Models (TPMs), which have proven to be a powerful tool in the interpretation of the infrared emission of asteroid surfaces, typically make use of shape models and spin axes obtained a priori for use as input boundary conditions. We test and then employ a TPM approach—under an assumption of an ellipsoidal shape—that exploits the combination of thermal multi-wavelength observations obtained at pre- and post-opposition. Thermal infrared data, when available at these observing circumstances, are inherently advantageous in constraining thermal inertia and sense of spin, among other physical traits. We show that, despite the lack of a priori knowledge mentioned above, the size, albedo, and thermal inertia of an object are well-constrained with precision comparable to that of previous techniques. Useful estimates of the surface roughness, shape, and spin direction can also be made, to varying degrees of success. Applying the method to Wide-Field infrared Survey Explorer observations, we present best-fit size, albedo, thermal inertia, surface roughness, shape elongation and sense of spin direction for 21 asteroids. We explore the thermal inertia’s correlation with asteroid diameter, after accounting for its dependence on the heliocentric distance.

79 ASTRONOMY AND ASTROPHYSICS↗

On-board Limb-based Shape Modeling for Small Body Navigation

Missions to small bodies within our solar system are becoming more frequent. Generally, shape models of the target body are required to perform proximity operations as demonstrated by the OSIRIS-REx, Hayabusa2, and Rosetta missions. However, these missions required image downlinking to create high-resolution models on the ground. In some missions, especially small-sats, there may be data downlink data constraints, resulting in the inability to provide the large number of images needed for high-resolution shape models. A solution to this is the ability to generate shape models on-board during the approach to the target or initial proximity surveying. Current work implements a limb-based shape model routine that is able to be executed on a Raspberry Pi 1, which is similar to the processing capability to the flight computer on OSIRIS-REx, and that does not require low phase angle geometries. Initial shape model results generated from Bennu approach (Nov 2-3, 2018) show that the limb-based shape model agrees well with a 75-cm SPC shape model generated after Preliminary Survey; Results are: min difference -7.047m, max difference 17.347m, mean 1.122m, and RMS 3.219m. Further scenarios are presented herein.

Limb-based↗

(abstract) Asteroid 4769 Casalia: Intrepretation of Optical Lightcurves Using a Radar-Derived Shape Model

A 167-parameter, 3-D shape model of Castalia, obtained from inversion of delay-Doppler images, constrained the object's subradar latitude on the date of the observations by defining an annular sky region that contains Castalia's pole. We have used the shape model and nominal Hapke parameters for S asteroids to model Castalia lightcurves obtained at Table Mountain Observatory on August 23-25, 1989, at solar phase angles ranging from 58(deg) to 90(deg). This investigation defines the projected pole's azimuthal orientation around the radar line of sight and therefore yields a least-squares estimate of the orientation of Castalia's north or south pole; there is insufficient geometric leverage to distinguish the rotation sense or to estimate values of Hapke parameters. The model lightcurves match the TMO data surprisingly well, given the modest number of shape parameters in the model and the fact that part of the asteroid was not seen by the radar.

asteroid Castalia shape radar 3-D model optical li↗

The generation and use of numerical shape models for irregular Solar System objects

We describe a procedure that allows the efficient generation of numerical shape models for irregular Solar System objects, where a numerical model is simply a table of evenly spaced body-centered latitudes and longitudes and their associated radii. This modeling technique uses a combination of data from limbs, terminators, and control points, and produces shape models that have some important advantages over analytical shape models. Accurate numerical shape models make it feasible to study irregular objects with a wide range of standard scientific analysis techniques. These applications include the determination of moments of inertia and surface gravity, the mapping of surface locations and structural orientations, photometric measurement and analysis, the reprojection and mosaicking of digital images, and the generation of albedo maps. The capabilities of our modeling procedure are illustrated through the development of an accurate numerical shape model for Phobos and the production of a global, high-resolution, high-pass-filtered digital image mosaic of this Martian moon. Other irregular objects that have been modeled, or are being modeled, include the asteroid Gaspra and the satellites Deimos, Amalthea, Epimetheus, Janus, Hyperion, and Proteus.

Simonelli, Damon P.↗

A Faceted Shape Model Approach to Altimetry and Velocimetry for Irregularly Shaped Bodies

Range and velocity sensors based on lidar or radar with multiple beams are often used to measure the altitude and velocity, respectively, of a spacecraft above a targetbody. A difficulty that arises when navigating about small bodies such as asteroids or comets, is that the notion of altitude is largely obscured by the irregular shape of the target surface. This paper develops a method to incorporate the multibeam altimeter and Doppler velocimeter measurements into the on-board spacecraft state estimator by using information from a faceted shape model representation of the target body surface.

state estimation↗

Fast automatic 3D liver segmentation based on a three-level AdaBoost-guided active shape model

Purpose: A robust, automatic, and rapid method for liver delineation is urgently needed for the diagnosis and treatment of liver disorders. Until now, the high variability in liver shape, local image artifacts, and the presence of tumors have complicated the development of automatic 3D liver segmentation. In this study, an automatic three-level AdaBoost-guided active shape model (ASM) is proposed for the segmentation of the liver based on enhanced computed tomography images in a robust and fast manner, with an emphasis on the detection of tumors. Methods: The AdaBoost voxel classifier and AdaBoost profile classifier were used to automatically guide three-level active shape modeling. In the first level of model initialization, fast automatic liver segmentation by an AdaBoost voxel classifier method is proposed. A shape model is then initialized by registration with the resulting rough segmentation. In the second level of active shape model fitting, a prior model based on the two-class AdaBoost profile classifier is proposed to identify the optimal surface. In the third level, a deformable simplex mesh with profile probability and curvature constraint as the external force is used to refine the shape fitting result. In total, three registration methods—3D similarity registration, probability atlas B-spline, and their proposed deformable closest point registration—are used to establish shape correspondence. Results: The proposed method was evaluated using three public challenge datasets: 3Dircadb1, SLIVER07, and Visceral Anatomy3. The results showed that our approach performs with promising efficiency, with an average of 35 s, and accuracy, with an average Dice similarity coefficient (DSC) of 0.94 ± 0.02, 0.96 ± 0.01, and 0.94 ± 0.02 for the 3Dircadb1, SLIVER07, and Anatomy3 training datasets, respectively. The DSC of the SLIVER07 testing and Anatomy3 unseen testing datasets were 0.964 and 0.933, respectively. Conclusions: The proposed automatic approach achieves robust, accurate, and fast liver segmentation for 3D CTce datasets. The AdaBoost voxel classifier can detect liver area quickly without errors and provides sufficient liver shape information for model initialization. The AdaBoost profile classifier achieves sufficient accuracy and greatly decreases segmentation time. These results show that the proposed segmentation method achieves a level of accuracy comparable to that of state-of-the-art automatic methods based on ASM.

60 APPLIED LIFE SCIENCES↗

Osiris-Rex Shape Model Performance During the Navigation Campaign

The Navigation Campaign of the OSIRIS-REx mission began when the first image of Bennu was recorded by the PolyCam high-resolution imager on Au-gust 17, 2018. In the ensuing months, two teams began building shape models based on imagery taken during the Approach and Preliminary survey phases to be used for the transition to landmark navigation in the Orbital A phase. The orbit determination team began analyzing and characterizing the performance and errors associated with each shape model delivery working closely to iterate on the next shape model delivery. By the end of Orbital A, shape models produced by the Altimetry Working Group and JPL exceeded pre-launch performance re-quirements. This paper provides a summary of the analysis performed during operations.

Leonard, Jason M.↗

Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model

Purpose: The aim of this study is to develop and validate a generic method for automatic bladder segmentation on cone beam computed tomography (CBCT), independent of gender and treatment position (prone or supine), using only pretreatment imaging data. Methods: Data of 20 patients, treated for tumors in the pelvic region with the entire bladder visible on CT and CBCT, were divided into four equally sized groups based on gender and treatment position. The full and empty bladder contour, that can be acquired with pretreatment CT imaging, were used to generate a patient-specific bladder shape model. This model was used to guide the segmentation process on CBCT. To obtain the bladder segmentation, the reference bladder contour was deformed iteratively by maximizing the cross-correlation between directional grey value gradients over the reference and CBCT bladder edge. To overcome incorrect segmentations caused by CBCT image artifacts, automatic adaptations were implemented. Moreover, locally incorrect segmentations could be adapted manually. After each adapted segmentation, the bladder shape model was expanded and new shape patterns were calculated for following segmentations. All available CBCTs were used to validate the segmentation algorithm. The bladder segmentations were validated by comparison with the manual delineations and the segmentation performance was quantified using the Dice similarity coefficient (DSC), surface distance error (SDE) and SD of contour-to-contour distances. Also, bladder volumes obtained by manual delineations and segmentations were compared using a Bland-Altman error analysis. Results: The mean DSC, mean SDE, and mean SD of contour-to-contour distances between segmentations and manual delineations were 0.87, 0.27 cm and 0.22 cm (female, prone), 0.85, 0.28 cm and 0.22 cm (female, supine), 0.89, 0.21 cm and 0.17 cm (male, supine) and 0.88, 0.23 cm and 0.17 cm (male, prone), respectively. Manual local adaptations improved the segmentation results significantly (p < 0.01) based on DSC (6.72%) and SD of contour-to-contour distances (0.08 cm) and decreased the 95% confidence intervals of the bladder volume differences. Moreover, expanding the shape model improved the segmentation results significantly (p < 0.01) based on DSC and SD of contour-to-contour distances. Conclusions: This patient-specific shape model based automatic bladder segmentation method on CBCT is accurate and generic. Our segmentation method only needs two pretreatment imaging data sets as prior knowledge, is independent of patient gender and patient treatment position and has the possibility to manually adapt the segmentation locally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Machine-Learning Algorithms for On-Board Asteroid Shape Model Determination

The Application of Machine-learning Algorithms for On-board Asteroid Shape Model Determination project will develop an innovative system for spacecraft navigation to expand the capability of small spacecraft to meet the critical challenges associated with small-body exploration. Such challenges include accurate navigation in a microgravity environment and precision targeting of particular locations on an asteroid surface for sample collection. This on-board system will cut the computational "umbilical" back to Earth-currently necessary for the generation of a global shape model that requires thousands of images with sufficient resolution and adequate variation of incidence and emission angles, processed manually by a team of experts on Earth for several months. Small satellites have limited bandwidth and are unable to downlink the data volume required for this processing, restricting their ability to perform deep-space asteroid exploration.

Machine learning algorithms↗

Statistical Shape Modeling of Cam Femoroacetabular Impingement

In this study, statistical shape modeling (SSM) was used to quantify three-dimensional (3D) variation and morphologic differences between femurs with and without cam femoroacetabular impingement (FAI). 3D surfaces were generated from CT scans of femurs from 41 controls and 30 cam FAI patients. SSM correspondence particles were optimally positioned on each surface using a gradient descent energy function. Mean shapes for control and patient groups were defined from the resulting particle configurations. Morphological differences between group mean shapes and between the control mean and individual patients were calculated. Principal component analysis was used to describe anatomical variation present in both groups. The first 6 modes (or principal components) captured statistically significant shape variations, which comprised 84% of cumulative variation among the femurs. Shape variation was greatest in femoral offset, greater trochanter height, and the head-neck junction. The mean cam femur shape protruded above the control mean by a maximum of 3.3 mm with sustained protrusions of 2.5-3.0 mm along the anterolateral head-neck junction and distally along the anterior neck, corresponding well with reported cam lesion locations and soft-tissue damage. This study provides initial evidence that SSM can describe variations in femoral morphology in both controls and cam FAI patients and may be useful for developing new measurements of pathological anatomy. SSM may also be applied to characterize cam FAI severity and provide templates to guide patient-specific surgical resection of bone.

statistical shape modeling↗

Concurrent segmentation of the prostate on MRI and CT via linked statistical shape models for radiotherapy planning

Purpose: Prostate gland segmentation is a critical step in prostate radiotherapy planning, where dose plans are typically formulated on CT. Pretreatment MRI is now beginning to be acquired at several medical centers. Delineation of the prostate on MRI is acknowledged as being significantly simpler to perform, compared to delineation on CT. In this work, the authors present a novel framework for building a linked statistical shape model (LSSM), a statistical shape model (SSM) that links the shape variation of a structure of interest (SOI) across multiple imaging modalities. This framework is particularly relevant in scenarios where accurate boundary delineations of the SOI on one of the modalities may not be readily available, or difficult to obtain, for training a SSM. In this work the authors apply the LSSM in the context of multimodal prostate segmentation for radiotherapy planning, where the prostate is concurrently segmented on MRI and CT. Methods: The framework comprises a number of logically connected steps. The first step utilizes multimodal registration of MRI and CT to map 2D boundary delineations of the prostate from MRI onto corresponding CT images, for a set of training studies. Hence, the scheme obviates the need for expert delineations of the gland on CT for explicitly constructing a SSM for prostate segmentation on CT. The delineations of the prostate gland on MRI and CT allows for 3D reconstruction of the prostate shape which facilitates the building of the LSSM. In order to perform concurrent prostate MRI and CT segmentation using the LSSM, the authors employ a region-based level set approach where the authors deform the evolving prostate boundary to simultaneously fit to MRI and CT images in which voxels are classified to be either part of the prostate or outside the prostate. The classification is facilitated by using a combination of MRI-CT probabilistic spatial atlases and a random forest classifier, driven by gradient and Haar features. Results: The authors acquire a total of 20 MRI-CT patient studies and use the leave-one-out strategy to train and evaluate four different LSSMs. First, a fusion-based LSSM (fLSSM) is built using expert ground truth delineations of the prostate on MRI alone, where the ground truth for the gland on CT is obtained via coregistration of the corresponding MRI and CT slices. The authors compare the fLSSM against another LSSM (xLSSM), where expert delineations of the gland on both MRI and CT are employed in the model building; xLSSM representing the idealized LSSM. The authors also compare the fLSSM against an exclusive CT-based SSM (ctSSM), built from expert delineations of the gland on CT alone. In addition, two LSSMs trained using trainee delineations (tLSSM) on CT are compared with the fLSSM. The results indicate that the xLSSM, tLSSMs, and the fLSSM perform equivalently, all of them out-performing the ctSSM. Conclusions: The fLSSM provides an accurate alternative to SSMs that require careful expert delineations of the SOI that may be difficult or laborious to obtain. Additionally, the fLSSM has the added benefit of providing concurrent segmentations of the SOI on multiple imaging modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Validation of a High Dimensional Shape Model for Organ Motion in Intact Cervical Cancer

Purpose: Validated models are needed to justify strategies to define planning target volumes (PTVs) for intact cervical cancer used in clinical practice. Our objective was to independently validate a previously published shape model, using data collected prospectively from clinical trials. Methods and Materials: We analyzed 42 patients with intact cervical cancer treated with daily fractionated pelvic intensity modulated radiation therapy and concurrent chemotherapy in one of 2 prospective clinical trials. We collected online cone beam computed tomography (CBCT) scans before each fraction. Clinical target volume (CTV) structures from the planning computed tomography scan were cast onto each CBCT scan after rigid registration and manually redrawn to account for organ motion and deformation. We applied the 95% isodose cloud from the planning computed tomography scan to each CBCT scan and computed any CTV outside the 95% isodose cloud. The primary aim was to determine the proportion of CTVs that were encompassed within the 95% isodose volume. A 1-sample t test was used to test the hypothesis that the probability of complete coverage was different from 95%. We used mixed-effects logistic regression to assess effects of time and patient variability. Results: The 95% isodose line completely encompassed 92.3% of all CTVs (95% confidence interval, 88.3%-96.4%), not significantly different from the 95% probability anticipated a priori (P=.19). The overall proportion of missed CTVs was small: the grand mean of covered CTVs was 99.9%, and 95.2% of misses were located in the anterior body of the uterus. Time did not affect coverage probability (P=.71). Conclusions: With the clinical implementation of a previously proposed PTV definition strategy based on a shape model for intact cervical cancer, the probability of CTV coverage was high and the volume of CTV missed was low. This PTV expansion strategy is acceptable for clinical trials and practice; however, we recommend daily image guidance to avoid systematic large misses in select patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Segmentation of the Eye in 3D Magnetic Resonance Imaging: A Novel Statistical Shape Model for Treatment Planning of Retinoblastoma

Purpose: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. Methods and Materials: Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. Results: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. Conclusion: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refined rotational period, pole solution, and shape model for (3200) Phaethon

(3200) Phaethon exhibits both comet- and asteroid-like properties, suggesting it could be a rare transitional object such as a dormant comet or previously volatile-rich asteroid. This justifies detailed study of (3200) Phaethon's physical properties as a better understanding of asteroid-comet transition objects can provide insight into minor body evolution. We therefore acquired time series photometry of (3200) Phaethon over 15 nights from 1994 to 2013, primarily using the Tektronix 2048 × 2048 pixel CCD on the University of Hawaii 2.2 m telescope. We utilized light curve inversion to (1) refine (3200) Phaethon's rotational period to P = 3.6032 ± 0.0008 hr; (2) estimate a rotational pole orientation of λ = +85° ± 13° and β = –20° ± 10°; and (3) derive a shape model. We also used our extensive light curve data set to estimate the slope parameter of (3200) Phaethon's phase curve as G ∼ 0.06, consistent with C-type asteroids. We discuss how this highly oblique pole orientation with a negative ecliptic latitude supports previous evidence for (3200) Phaethon's origin in the inner main asteroid belt as well as the potential for deeply buried volatiles fueling impulsive yet rare cometary outbursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Multibeam Altimeter Navigation Update Using Faceted Shape Model

A method of incorporating information, acquired by a multibeam laser or radar altimeter system, pertaining to the distance and direction between the system and a nearby target body, into an estimate of the state of a vehicle upon which the system is mounted, involves the use of a faceted model to represent the shape of the target body. Fundamentally, what one seeks to measure is the distance from the vehicle to the target body.

Bayard, David S.↗

A Solar Sail Shape Modeling Approach for Attitude Control Design and Analysis

Solar sails operating in the space environment experience deformations in sail shape that result in relatively large disturbance torques which dictate the required performance of the spacecraft attitude control and momentum management systems. These deformations are driven by thermal loads on the booms (due to uneven solar heating), manufacturing and assembly tolerances, and variations in membrane tension. The Solar Cruiser spacecraft utilizes a four-quadrant sail design with four 30-meter length booms and four triangular sail membranes, creating a square sail structure of >1600 m2. Medium-fidelity mesh models were developed based on a characteristic deformed shape. A series of parametric studies were conducted using this shape paradigm to determine worst-case deformed sail shapes which produce bounding disturbance torques. A large database of shapes was produced, and the forces and moments induced by each individual shape were calculated using a Rios-Reyes reduced order generalized sail model. Two were selected as reference worst-case shapes for the Solar Cruiser mission: one which produced the highest pitch/yaw root-sum-squared (RSS) torque, and one which produced the highest roll torque. The results showed that the worst-case shapes at high solar incidence angles induce significantly higher (2-10x) disturbance torques than an ideal, flat-plate sail. Even with considerable safety margins, assuming an ideal sail is unlikely to sufficiently bound the disturbances, which is critical when designing the attitude control system and sizing actuators. Accurate sail shape modeling methodologies should therefore be employed on future solar sail missions.

Solar Sail↗