Search NASA⌕ Search

SEARCH · Search NASA

Results for “site evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Coronado Generating Station Repowering Evaluation - Siting Evaluation

The purpose of this initial siting evaluation is to consider the suitability of the Salt River Project (SRP) owned land at/near Coronado Generating Station (CGS) for a nuclear generating station (including advanced light water reactors, light water small modular reactors, and non-light-water designs1) and to assess if there are any exclusionary or avoidance factors associated with coal to nuclear repowering at CGS. This initial siting evaluation considers several characteristics (e.g., environmental conditions, seismic concerns, site footprint, water use, etc.) and highlights favorable/preferred characteristics as well as potential risks to feasibility. The results are intended to inform SRP on the strengths and weaknesses associated with the CGS site and inform the selection of candidate nuclear technologies for the CGS site that align with SRP’s mission and business objectives. This report relies on industry-recognized siting guidance, including Electric Power Research Institute’s (EPRI’s) Siting Guide (Reference 1) 2 and Nuclear Regulatory Commission’s (NRC’s) Regulatory Guide (RG) 4.7 (Reference 3), as well as nuclear domain expertise within the Gateway for Accelerated Innovation in Nuclear (GAIN), MPR Associates, Inc. (MPR), and the Idaho National Laboratory (INL).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ghent Generating Station Nuclear Study: Siting Evaluation

The purpose of this initial siting evaluation is to assess the suitability of the PPL Corporation (PPL) owned land at/near the Kentucky Utilities Ghent Generating Station (GGS) for the deployment of advanced nuclear reactors and to determine if there are any exclusionary or avoidance factors associated with siting nuclear power at GGS. The formal siting process for a nuclear reactor requires a great level of time (i.e., multiple years), effort, and detail. The Electric Power Research Institute (EPRI) estimates the formal siting process could take a dedicated team between one and three years to complete. This initial siting evaluation considers several characteristics (e.g., environmental conditions, seismic concerns, footprint, water use, etc.) and highlights favorable/preferred characteristics as well as potential risks to feasibility. Potential risks were explored in greater detail to provide PPL with additional insights to support decision planning. The results indicate the strengths and weaknesses associated with the GGS site as a location for a nuclear generating station and are intended to inform PPL’s next steps. The results of this initial siting evaluation will also inform the selection of candidate nuclear technologies for the GGS site that align with PPL’s mission and business objectives.

99 GENERAL AND MISCELLANEOUS↗

Modeling nuclear waste disposal in crystalline rocks at the Forsmark and Olkiluoto repository sites – Evaluation of potential thermal–mechanical damage to repository excavations

We conduct coupled thermo-hydro-mechanical modeling of a KBS-3V repository design in crystalline rocks, using data and conditions from the Forsmark in Olkiluoto repository sites in Sweden and Finland. The study focuses on repository performance related to the impact of thermal and hydraulic evolution on the potential for thermal–mechanical damage to underground repository excavations. For the designs and conditions considered at the Forsmark and Olkiluoto repository sites, the simulations show a peak temperature well under the adopted performance target of a 100°C maximum temperature, whereas there is still a high potential for thermal–mechanical damage to the KBS-3V waste deposition holes. The thermal–mechanical damage is much more likely if rock permeability is so low that it delays saturation and swelling of bentonite-clay-based backfill beyond the time for the thermal–mechanical peak, which occurs 50 to 100 years after nuclear waste deposition. We also found that sidewalls of the KBS-3V emplacement tunnels are vulnerable to tensile fracturing due to the combined effect of thermal stressing and backfill swelling. The study highlights a strong interaction between bentonite-based backfill and host rock through capillary suction along with induced rock desaturation. A careful design and selection of the bentonite-clay-based backfill materials for KBS-3V tunnels and deposition holes can facilitate a timely saturation and backfill swelling that in turn can minimize thermal–mechanical damage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-site evaluation of stratified and balanced sampling of soil organic carbon stocks in agricultural fields

Estimating soil organic carbon (SOC) stocks in agricultural fields is essential for environmental and agronomic research, management, and policy. Stratified sampling is a classic strategy for estimating mean soil properties, and has recently been codified in SOC monitoring protocols. However, for the specific task of estimating the SOC stock of an agricultural field, concrete guidance is needed for which covariates to stratify on and how much stratification can improve estimation efficiency. It is also unknown how stratified sampling of SOC stocks compares to modern alternatives, notably doubly balanced sampling. To address these gaps, we collected high-density (average of 7 samples ha -1 ) and deep (average of 75 cm) measurements of SOC stocks at eight commercial fields under maize-soybean production in two US Midwestern states. We combined these measurements with a Bayesian geostatistical model to evaluate stratified and balanced sampling strategies that use a set of readily-available geographic, topographic, spectroscopic, and soil survey data. We examined the number of samples needed to achieve a given level of SOC stock estimation accuracy. While stratified sampling using these variables enables an average sample size reduction of 17% (95% CI, 11% to 23%) compared to simple random sampling, doubly balanced sampling is consistently more efficient, reducing sample sizes by 32% (95% CI, 25% to 37%). The data most important to these efficiency gains are a remotely-sensed SOC index, SSURGO estimates of SOC stocks, and the topographic wetness index. We conclude that in order to meet the urgent challenge of climate change, SOC stocks in agricultural fields could be more efficiently estimated by taking advantage of this readily-available data, especially with doubly balanced sampling.

54 ENVIRONMENTAL SCIENCES↗

Geochemical and Microstructural Characterization of Shale Rock: A Workflow for Site Evaluation for Energy–Fluids Storage

Shales are a central component of petroleum systems, as source, seal, and unconventional reservoir rocks. Unlike traditional unconventional shale, a newly emerging Caney Shale play is regarded as an unconventional of unconventional shales (UUS), due to its high content of fine-grained materials, lower reservoir porosity, dominance of nanopores, and a scarcity of visible natural fractures. Other developed unconventional shales such as the Woodford and Barnett have larger average pore size, higher porosity, and extensive natural fractures at core scale that contribute to reservoir quality. In this work, the Caney Shale was cored in entirety to characterize its interbedded ductile and reservoir intervals and establish criteria for their recognition. Representative ductile and reservoir intervals known as D2 and R3, respectively, were selected for detailed analysis including variations in elemental composition, mineralogy, facies, and the presence of natural fractures at well and core scales using X-ray fluorescence, X-ray diffraction, and thin section and core description. Characteristics of microstructure and microgeochemistry at nano- and microscales are compared using field emission scanning electron microscopy with energy dispersive spectroscopy and lowpressure nitrogen adsorption isotherms with fractal dimension analysis. The ductile (detrital clay-rich) member D2 is characterized by higher concentrations of Ti and Al and lower Si, while the reservoir R3 (possibly biogenic silica-accumulated) is characterized by lower Ti and Al and higher Si. Eight mixed carbonate–siliciclastic facies are recognized, and R3 shows a higher heterogeneity of facies stacking and average fracture abundance than D2. Further, R3 shows a more microscopically heterogeneous fabric/texture of matrix and a higher microporosity than D2 that has a higher pore surface heterogeneity. A fundamental understanding of the compositional and microstructural characteristics of UUS and further ductile/reservoir intervals will allow for a better assessment of reservoir quality, more effective production of hydrocarbons, and optimized selection of safe caprocks in carbon sequestration and subsurface hydrogen storage.

58 GEOSCIENCES↗

Evaluation of Sites for Advanced Reactor Demonstrations at Idaho National Laboratory

The purpose of this siting evaluation is to identify a list of candidate site locations or areas within INL boundaries for onsite demonstration of advanced reactors. A comparison of suitable advanced reactor sites is provided and includes evaluation of existing buildings, previously developed sites, and undeveloped sites across the INL Site.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Siting Analyses for Elementl Power (Final CRADA Report)

This report summarizes siting evaluation assistance provided to Elementl Power under CRADA/NFE-23-09638 for suitability of advanced nuclear technologies to meet siting criteria from the Nuclear Regulatory Commission (NRC) and associated guidance documents including the Electric Power Research Institute (EPRI) siting guide and other proprietary datasets. Elementl Power provided sites for reactor siting evaluations using the Oak Ridge – Siting Analysis for power Generation Expansion (OR-SAGE) tool. Individual data packages for each site are provided separately.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Siting Analyses for Advanced Nuclear Advisors (Final CRADA Report)

This report summarizes siting evaluation assistance provided to Advanced Nuclear Advisors (ANA) under CRADA/NFE-25-10693 for suitability of advanced nuclear technologies to meet siting criteria from the Nuclear Regulatory Commission (NRC) and associated guidance documents including the Electric Power Research Institute (EPRI) siting guide and other proprietary datasets. Advanced Nuclear Advisors provided sites for reactor siting evaluations using the Oak Ridge – Siting Analysis for power Generation Expansion (OR-SAGE) tool. Individual data packages for each site are provided separately.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Brain‐age prediction: Systematic evaluation of site effects, and sample age range and size

Abstract Structural neuroimaging data have been used to compute an estimate of the biological age of the brain (brain‐age) which has been associated with other biologically and behaviorally meaningful measures of brain development and aging. The ongoing research interest in brain‐age has highlighted the need for robust and publicly available brain‐age models pre‐trained on data from large samples of healthy individuals. To address this need we have previously released a developmental brain‐age model. Here we expand this work to develop, empirically validate, and disseminate a pre‐trained brain‐age model to cover most of the human lifespan. To achieve this, we selected the best‐performing model after systematically examining the impact of seven site harmonization strategies, age range, and sample size on brain‐age prediction in a discovery sample of brain morphometric measures from 35,683 healthy individuals (age range: 5–90 years; 53.59% female). The pre‐trained models were tested for cross‐dataset generalizability in an independent sample comprising 2101 healthy individuals (age range: 8–80 years; 55.35% female) and for longitudinal consistency in a further sample comprising 377 healthy individuals (age range: 9–25 years; 49.87% female). This empirical examination yielded the following findings: (1) the accuracy of age prediction from morphometry data was higher when no site harmonization was applied; (2) dividing the discovery sample into two age‐bins (5–40 and 40–90 years) provided a better balance between model accuracy and explained age variance than other alternatives; (3) model accuracy for brain‐age prediction plateaued at a sample size exceeding 1600 participants. These findings have been incorporated into CentileBrain ( https://centilebrain.org/#/brainAGE2 ), an open‐science, web‐based platform for individualized neuroimaging metrics.

60 APPLIED LIFE SCIENCES↗

Qualitative Risk Assessment of Legacy Wells within the Estimated Prairie State Generating Company Area of Review

This report details the digitization of a legacy wellbore database, including data processing assumptions, parameter estimation, and risk assessment methodology. The database, comprising 6,454 documents, was provided by ISGS. It includes valuable data from the Prairie State Generating Company (PSGC) and One Earth Energy (OEE) sites of the CarbonSAFE Phase III – Illinois Storage Corridor project. The report focuses on wells within a 15-mile radius from the Lively Grove #1 (LG#1) well at PSGC site, evaluating subsurface conditions and potential risks. A total of 4,386 wellbores within 15 miles of the LG#1 well were filtered based on depth and formation codes. LG#1 is the stratigraphic well at the PSGC site drilled in 2021. Ninety-four (94) wells penetrating the Maquoketa Shale Group (the primary confining unit) within the estimated area-of-review (AoR) for the PSGC site were evaluated using a qualitative risk assessment (QRA) methodology. The QRA developed by Arbad et al. 2022 focuses on legacy wells within the AoR and categorizes them based on well construction details. The QRA identifies wells that need immediate attention by categorizing them based on penetration depth and protection. Wells within the AoR were categorized into nine groups based on penetrations and protections. These categories range from Type 1 wells, with no documentation, to Type 9 wells, which do not penetrate the primary confining unit or storage reservoir (unit). Well accessibility within the AoR varies based on well status, including Dry & Abandoned (DA), Plugged & Abandoned (PA), Injection (INJ), Oil/Gas Producing (PROD), and Observation (Obs) wells. Accessibility levels were determined by well construction, with DA wells being the least accessible and Observation wells the most accessible, impacting gas leakage detection possibilities. Remedial action priority of wells decreases from Type 1 to Type 9 wells. Type 1 to Type 6 wells with status DA and PA require immediate attention, while Type 7 and Type 8 wells are low priority. A risk matrix used to prioritize corrective actions for legacy wells is proposed to categorize wells within an AoR based on penetrations, protections, and accessibility. The methodology involves data acquisition, well categorization into nine types, and determining CO 2 leakage pathways using well schematics and geospatial mapping. This approach is particularly useful for managing the integrity of legacy wells throughout the lifecycle of a Carbon Capture and Storage (CCS) project. A qualitative risk assessment of 94 wells within the AoR of the PSGC site identified 54 wells with high priority for corrective action due to penetration of the primary containment seal. The assessment utilizes color-coded maps to categorize well types and prioritize corrective actions, providing a comprehensive analysis. Schematics of wells penetrating the primary confining unit were drawn, and leakage pathways were identified. Details of all wells penetrating the confining zone are provided in the appendix, including information on well types, plugging, and casing status.

01 COAL, LIGNITE, AND PEAT↗

Path-BigBird: An AI-Driven Transformer Approach to Classification of Cancer Pathology Reports

PURPOSE Surgical pathology reports are critical for cancer diagnosis and management. To accurately extract information about tumor characteristics from pathology reports in near real time, we explore the impact of using domain-specific transformer models that understand cancer pathology reports. METHODS We built a pathology transformer model, Path-BigBird, by using 2.7 million pathology reports from six SEER cancer registries. We then compare different variations of Path-BigBird with two less computationally intensive methods: Hierarchical Self-Attention Network (HiSAN) classification model and an offthe-shelf clinical transformer model (Clinical BigBird). We use five pathology information extraction tasks for evaluation: site, subsite, laterality, histology, and behavior. Model performance is evaluated by using macro and micro F 1 scores. RESULTS We found that Path-BigBird and Clinical BigBird outperformed the HiSAN in all tasks. Clinical BigBird performed better on the site and laterality tasks. Versions of the Path-BigBird model performed best on the two most difficult tasks: subsite (micro F 1 score of 72.53, macro F 1 score of 35.76) and histology (micro F 1 score of 80.96, macro F 1 score of 37.94). The largest performance gains over the HiSAN model were for histology, for which a Path-BigBird model increased the micro F 1 score by 1.44 points and the macro F 1 score by 3.55 points. Overall, the results suggest that a Path-BigBird model with a vocabulary derived from wellcurated and deidentified data is the best-performing model. CONCLUSION The Path-BigBird pathology transformer model improves automated information extraction from pathology reports. Although Path-BigBird outperforms Clinical BigBird and HiSAN, these less computationally expensive models still have utility when resources are constrained.

60 APPLIED LIFE SCIENCES↗

Corral Summit Pumped Storage Hydropower Hybrid: Site Suitability Assessment

In 2024, Idaho National Laboratory (INL) and Pacific Northwest National Laboratory (PNNL) initiated a technical-assistance project to support Cat Creek Energy, LLC, (CCE) in evaluating site suitability for the proposed Corral Summit Pumped Storage Hydropower (PSH) project in south-central Idaho near Mackay Reservoir. The Corral Summit facility incorporates battery storage and photovoltaic (PV) solar arrays in a Trybrid configuration to deliver large-volume long-duration (LVLD) storage solutions for rural electric cooperatives in eastern Idaho. The evaluation process focused on determining the most-suitable location for the upper reservoir of the PSH system, guided by a comprehensive assessment framework spanning multiple categories, including physical characteristics, environmental constraints, building infrastructure, regulatory constraints, cultural resources and sensitivity, social factors, and power market and grid integration. Each site was analyzed based on a ranking scale (0–1), which scores ranging from “severely disfavored” to “highly favored,” allowing detailed comparisons of site-specific conditions. Categories such as hydraulic head, utilities corridor, land ownership, and transmission-grid limitations emerged as key contributors to the overall assessment. Site 2 (Idaho Trust) demonstrated a slight advantage over Site 1 (Bureau of Land Management) primarily due to favorable outcomes in regulatory constraints, building infrastructure, and power-market integration. However, Site 1 outperformed Site 2 in factors related to physical characteristics and social factors. The report emphasizes the need for further evaluation of both sites before clear determination of which site is preferred, due to the limited information available on either site at the time of this report. Key areas of evaluation to clearly define the preferred site are ecological impacts, cultural-resource surveys, and economic-feasibility assessments. For successful project execution, recommended follow-up actions include seismic and geotechnical surveys, groundwater and habitat monitoring, regulatory reviews of water rights and right-of-way agreements, cultural engagement with local tribal governments, and enhanced stakeholder strategies. These efforts will ensure the Corral Summit Trybrid facility meets local energy needs while balancing environmental, social, and regulatory responsibilities.

13 - HYDRO ENERGY↗

Corral Summit Pumped Storage Hydropower Hybrid Site Suitability Assessment (Rev.1)

In 2024, Idaho National Laboratory (INL) and Pacific Northwest National Laboratory (PNNL) initiated a technical-assistance project to support Cat Creek Energy, LLC, (CCE) in evaluating site suitability for the proposed Corral Summit Pumped Storage Hydropower (PSH) project in south-central Idaho near Mackay Reservoir. The Corral Summit facility incorporates battery storage and photovoltaic (PV) solar arrays in a Trybrid configuration to deliver large-volume long-duration (LVLD) storage solutions for rural electric cooperatives in eastern Idaho. The evaluation process focused on determining the most-suitable location for the upper reservoir of the PSH system, guided by a comprehensive assessment framework spanning multiple categories, including physical characteristics, environmental constraints, building infrastructure, regulatory constraints, cultural resources and sensitivity, social factors, and power market and grid integration. Each site was analyzed based on a ranking scale (0–1), which scores ranging from “severely disfavored” to “highly favored,” allowing detailed comparisons of site-specific conditions. Categories such as hydraulic head, utilities corridor, land ownership, and transmission-grid limitations emerged as key contributors to the overall assessment. Site 2 (Idaho Trust) demonstrated a slight advantage over Site 1 (Bureau of Land Management) primarily due to favorable outcomes in regulatory constraints, building infrastructure, and power-market integration. However, Site 1 outperformed Site 2 in factors related to physical characteristics and social factors. The report emphasizes the need for further evaluation of both sites before clear determination of which site is preferred, due to the limited information available on either site at the time of this report. Key areas of evaluation to clearly define the preferred site are ecological impacts, cultural-resource surveys, and economic-feasibility assessments. For successful project execution, recommended follow-up actions include seismic and geotechnical surveys, groundwater and habitat monitoring, regulatory reviews of water rights and right-of-way agreements, cultural engagement with local tribal governments, and enhanced stakeholder strategies. These efforts will ensure the Corral Summit Trybrid facility meets local energy needs while balancing environmental, social, and regulatory responsibilities.

13 - HYDRO ENERGY↗

lllinois Storage Corridor CarbonSAFE Phase III: Pre-drilling Site Assessment: Prairie State Generating Company

The Illinois Storage Corridor project will drill a stratigraphic test well as part of the Illinois Storage Corridor CarbonSAFE Phase 3 project near the Prairie State Generating Company coal-fired power plant near Marissa, Illinois. The pre-drilling site evaluation has considered the primary target reservoirs, the Potosi Dolomite and St. Peter Sandstone, and primary seal, the Maquoketa Group. Data to be collected from the well include core, fluid samples, in situ well tests, geophysical logs intended to provide information on lithologic, geomechanical, and geophysical characteristics to determine the feasibility for the geologic sequestration of 50 million metric tons or more of injected carbon dioxide. The planned drilling site has been evaluated using available subsurface geologic data and analyses from the Illinois Basin. These data provide lithologic and structural information, shallow groundwater resource distribution, location of known nearby wellbores, and regional drilling characteristics. The data were used to generate geologic structure and isopach maps for the target reservoir and caprock strata and for prognosing the tops of major lithologic units to aid drilling and coring procedures. The regional analyses indicate that no known structural features are expected to negatively impact the target storage reservoir or caprock. No protected and sensitive areas, groundwater resources, or existing resource development are expected to be impacted by the proposed well drilling activities. The well is planned to be drilled to a total depth of approximately 5,600 feet (1,707 m) and terminate in the Precambrian. Cores (up to 5 intervals) will be collected from the Maquoketa Group, confining units above the St. Peter Sandstone, St. Peter Sandstone, confining units of the Potosi Dolomite and the Potosi Dolomite. Water samples will be attempted to be collected from the St. Peter Sandstone and Potosi Dolomite. Potential impact on drilling progress is a lost circulation zone in the Potosi Dolomite, which has been demonstrated to have intermittent cavernous porosity from karstification elsewhere in the Illinois Basin. This document also presents a preliminary coring and sampling program, proposed logging suite, and well testing program, all of which will be reviewed during drilling.

01 COAL, LIGNITE, AND PEAT↗

Code Description for "Brief Communication: Monitoring snow depth using small, cheap, and easy-to-deploy ground surface temperature sensors"

Temporally continuous snow depth estimates are vital for understanding changing snow patterns and impacts on permafrost in the Arctic. We train a random forest machine learning model to predict snow depth from variability in ground surface temperature. To our knowledge, this is the first time that small ground surface temperature sensors have been used to estimate snow depth. The model performs well at sites where the model was trained and at pan-arctic evaluation sites (RMSE <= 0.15 m). Small temperature sensors are cheap and easy-to-deploy, so this technique enables spatially distributed and temporally continuous snowpack monitoring to an extent previously infeasible. The model is flexible and can be applied to datasets retroactively to retrieve snow depth estimates at additional sites. This code package includes a *.joblib file of the trained random forest model and a *.ipynb file showing how to clean input data, train the random forest model, and apply the model.

Bachand, Claire↗