Search NASASearch

SEARCH · Search NASA

Results for “smart power grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Smart Contracts for Power Grid Applications Using the Advanced DLT Cyber Grid Guard Testbed

In this study is presented two power system applications with distributed ledger technology (DLT) and smart contracts (SC) that were assessed in a Cyber-Grid-Guard System (CGGS) advanced testbed, with protective relays, power meters, communication devices, DLT devices, synchronized time source, clock displays and real time simulator. This CGGS testbed was set in the Advanced Protection Lab, 252 lab space of the Grid Research Integration and Deployment Center (GRID- C), at Oak Ridge National Laboratory. In power grids, customer-owned distributed energy resources (DERs) are more frequent than in the past, and the numbers of points of interconnection (POI) with customer-owned DERs have increased. Disruptive operation from DERs presents a risk to grid operations, and protective relays located at the POI are used to isolate out-of-tolerance or poorly behaving of DERs. Ensuring the integrity of data from the relays at the POI, and DLT could enhance the security of the power grids. The first application is a SC to define and control the allowable total power factor (TPF) of the DER (wind farm) output, and the terms of the SC are implemented using DLT with a CGGS for a customer-owned DER. The TPF SC was implemented by the CGGS using DLT. The experimental model was performed with a real-time simulator using a CGGS and relay in-the-loop. The data collected from the CGGS were used to execute the TPF SC. The TPF limits were between +0.9 and +1.0, and the breakers’ operation in the POI was controlled by the relay using the SC. The events were collected from the real-time simulator, CGGS, and SEL 700GT relay to validate a successful application of the TPF SC using DLT. The second application is a SC to measure and control the allowable voltage service limits (VSL) by the CGGS using DLT. The tests were performed by using a real-time simulator, CGGS and relay in-the-loop. The data was collected from the CGGS that executed the SC. The main constraints were defined based on ANSI C84.1 service voltage limits, and the operation of the breakers in the POI. The events were collected from the CGGS, and SEL 700GT relay to assess a successful operation of the VSL SC using DLT.

24 POWER TRANSMISSION AND DISTRIBUTION

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization

Convex Optimization with Smart Grid Examples

In this talk, we give an overview of the field of convex optimization and work through four canonical problems that relate to electrical power systems and smart grids. The purpose of these examples is to demonstrate the breadth of applications of convex optimization in energy research and to show that toy versions of these problems can be solved in just a few lines of code, indicating the scale and complexity of problems that can be tackled with a more detailed treatment. We emphasize the cvxpy modeling language as a foundational technology that enables rapid development and prototyping of convex optimization problems, allowing researchers to focus on model development rather than get caught in the weeds of numerical and code implementation.

24 POWER TRANSMISSION AND DISTRIBUTION

Designing resilient IoT and Edge Computing with federated tinyML

The rapid growth of the Internet of Things (IoT) and Edge Computing (EC) has brought significant conveniences to modern society but has also greatly expanded the cyber attack surfaces, particularly as these technologies are being increasingly integrated into critical systems such as power grids, healthcare, and smart homes. Here, to improve IoT/EC’s cybersecurity posture, we leveraged Artificial Intelligence (AI) and Machine Learning (ML) by employing tinyML to monitor voluminous IoT data for cyber threats while addressing devices’ resource constraints, and utilizing Federated Learning (FL) to share local detection knowledge across the system while preserving privacy. Building on our three-layer architecture combining tinyML and FL to enhance autonomous cyber attack detection, this paper demonstrated that the architecture improves detection accuracy, reduces resource consumption, and enables lightweight, secure IoT device monitoring. These results were validated using the public N-BaIoT dataset as well as real IoT network traffic data collected under multiple attack scenarios from our testbeds. Additionally, we introduced an enhanced FL methodology with a novel preprocessing stage, including federated feature selection and global preprocessor construction, to address IoT/EC data heterogeneity. We developed a physical IoT testbed for attack simulations and data collection, implemented a tinyML-powered detector for realistic model validation, and also built a virtual testbed for scalable evaluations of FL models across diverse network environments.

Cognitive cyber

Discovering the Most Severe K-Point Failure Based on Reinforcement Learning: Preprint

Smart devices are essential to ensure the stability of the power grid and resilience to intermittent energy production. However, smart devices can also be the target of cyber adversaries that may exploit false data injection attacks (FDIAs) to induce unstable grid conditions. A practical consideration of FDIA mitigation approaches is addressed here: given a finite available budget, for which smart device should cyber-threat mitigation be deployed first? In this work, this question is answered by identifying the so-called most-sensitive devices, i.e., the devices that, if compromised, can let an adversary induce the most serious grid instabilities. The method proposed utilizes an adversarial reinforcement learning (RL) framework to identify the k-mostsensitive smart devices (here, smart inverters). The adversarial agent can tamper with the compromised inverters' active and reactive operating power setup points, with the goal of maximizing voltage deviations. Numerical results show that the proposed RL method finds the optimal attack scenarios for 1-point failure and the near-optimal solution for the 2-point case. Additionally, the proposed RL method achieves an 8.8 speed-up ratio in running time compared to the brute force method for the 2-point case.

97 MATHEMATICS AND COMPUTING

Cognitive IoT and Edge Computing for Intrusion Detection with Federated TinyML

Internet of Things (IoT) and Edge Computing (EC) are rapidly becoming an integral part of the modern society. By 2030, there is estimated to be over 40 billion active and connected IoT devices [1]. This rapid progress also comes with a significant implication on cybersecurity. Back-end infrastructure and systems have a much broader attack than they did previously due to vulnerable IoT/EC devices being connected to wireless networks. This expanding attack surface is a growing concern because IoT/EC are increasingly being used in critical systems such as power grids, health care, and smart homes. To effectively address a problem of this scale, cognitive cyber methods—which can autonomously detect and react to cyber attacks as they develop—are needed. To address this, we bring Artificial Intelligence (AI) and Machine Learning (ML) to IoT/EC devices, using tinyML to monitor voluminous IoT data against cyber threats, and using Federated Learning (FL) to share local detection knowledge across the system while preserving privacy. We propose a novel three-layer architecture: (1) an IoT layer for tinyML-based inference, (2) an edge layer for ML model training, and (3) a cloud layer for FL operations. Using the publicly available 11-class N-BaIoT dataset [2], we demonstrate that this architecture mitigates resource constraints at the IoT layer while improving detection accuracy over standard two-layer designs. An outlier-resistant scaler, feature reduction, and quantization enable the tinyML model to maintain detection accuracy with a reduced model size. Additionally, federated learning that only utilizes the intersection (across heterogenous devices) of the reduced feature set achieves superior detection accuracy compared to locally trained models.

Li, Mingyan [ORNL] (ORCID:0009000569532640)

SDN-Based Dynamic Cybersecurity Framework of IEC-61850 Communications in Smart Grid

In recent years, critical infrastructure and power grids have experienced a series of cyber-attacks, leading to temporary, widespread blackouts of considerable magnitude. Since most substations are unmanned and have limited physical security protection, cyber breaches into power grid substations present a risk. Nowadays, the susceptibility of SDN architecture to cyber-attacks has exhibited a notable increase in recent years, as indicated by research findings. This suggests a growing concern regarding the potential for cybersecurity breaches within the SDN framework. In this paper, we propose a hybrid intrusion detection system (IDS)-integrated SDN architecture for detecting and preventing the injection of malicious IEC 61850-based generic object-oriented system event (GOOSE) messages in a digital substation. Additionally, this program locates the fault’s location and, as a form of mitigation, disables a certain port. Furthermore, implementation examples are demonstrated and verified using a hardware-in-the-loop (HIL) testbed that mimics the functioning of a digital substation.

Liu, Chen-Ching [Virginia Tech] (ORCID:00000002894

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE

Enhancing Time Synchronization in Smart Grid With White Rabbit: Theory, Architecture, and Challenges

The smart grid aims to provide economically efficient and sustainable power to consumers with high quality and security. However, the increasing integration of distributed renewable energy sources presents challenges for smart grid protection and control systems. Here, to enhance smart grid operations, this article introduces White Rabbit (WR) as a more precise and accurate time synchronization technique. To explore White Rabbit’s potential applications in the smart grid, this study first explains existing time synchronization techniques and their limitations, followed by an analysis of the role and importance of time synchronization in smart grids. A comprehensive survey is then conducted, covering the theories, principles, implementations, performances, and existing application cases of White Rabbit. The findings suggest that White Rabbit is a promising technique for smart grid deployment. However, several challenges remain on the path to large-scale implementation. These challenges are analyzed in detail, highlighting key areas for future research.

Liu, Yu [University of Tennessee, Knoxville, TN (U

Voltage stability smart meter for analyzing voltage data and controlling an electrical power source and/or an electric appliance

Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.

Min, Liang

Electrical Load Forecasting Over Multihop Smart Metering Networks With Federated Learning

Electric load forecasting is essential for power management and stability in smart grids. This is mainly achieved via advanced metering infrastructure, where smart meters (SMs) record household energy data. Traditional machine learning (ML) methods are often employed for load forecasting, but require data sharing, which raises data privacy concerns. Federated learning (FL) can address this issue by running distributed ML models at local SMs without data exchange. However, current FL-based approaches struggle to achieve efficient load forecasting due to imbalanced data distribution across heterogeneous SMs. Here, this article presents a novel personalized FL (PFL) method for high-quality load forecasting in metering networks. A meta-learning-based strategy is developed to address data heterogeneity at local SMs in the collaborative training of local load forecasting models. Moreover, to minimize the load forecasting delays in our PFL model, we study a new latency optimization problem based on optimal resource allocation at SMs. A theoretical convergence analysis is also conducted to provide insights into FL design for federated load forecasting. Extensive simulations from real-world datasets show that our method outperforms existing approaches regarding better load forecasting and reduced operational latency costs.

Rahman, Ratun [Univ. of Alabama, Huntsville, AL (U

Practical Implementation of GPU-based Computing at the Grid Edge for Resilience Scenarios

This paper presents a practical implementation of GPU-accelerated computing at the grid edge to enhance power system resilience through next-generation smart meters. Advanced Metering Infrastructure (AMI) systems rely predominantly on centralized processing architectures, which limit real-time response capabilities during grid disturbances. This work proposes the integration of GPU-enabled computational platforms directly within smart meter to enable local execution support for power system analytics, fault detection algorithms, and optimization routines. The proposed framework uses the Julia programming language to leverage highperformance parallel computing capabilities while maintaining code portability and development efficiency. We use two experimental scenarios to benchmark the computational feasibility of this approach: sparse linear system solutions representative of power flow analyses, and multi-stage production cost simulations incorporating unit commitment and economic dispatch operations. Results demonstrate that computationally intensive power system algorithms, such as those supporting resilience scenario calculations, can be effectively executed at the distribution edge using commercially available embedded GPU hardware. Keywords—GPU acceleration, edge computing, smart meters, grid resilience, AMI, resilience.

De Souza, Reubun [School of Electrical Engineering

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION

Scalability and Effectiveness of Smart Charge Management

The rise in electric vehicle (EV) adoption presents growing challenges for power grids, particularly from simultaneous residential charging, which can cause voltage fluctuations and increase feeder peak loads. Baltimore Gas and Electric (BGE), with support from the U.S. Department of Energy, initiated a pilot program to evaluate managed residential EV charging through Smart Charge Management (SCM). This study analyzes real-world charging behavior data from the pilot and feeder-level base loads from BGE to simulate residential charging scenarios through 2035 across the Washington, DC–Baltimore region. Grid impacts under unmanaged charging are compared to three SCM strategies: TOU-immediate, TOU-distributed, and Load Balancing. Results show that the magnitude of peak reduction is highly feeder-dependent. Some feeders achieve reductions of more than 40% at high enrollment levels, while others show improvements closer to 10–15%. This heterogeneity reflects differences in baseline feeder load shapes, EV penetration, and plug-in behavior across customers. Results also highlight trade-offs between shifting load away from peak periods and minimizing secondary demand peaks, offering practical insights for future utility program design.

Electric vehicle

A cross-dimensional analysis of data-driven short-term load forecasting methods with large-scale smart meter data

Electricity load forecasting is essential to utility operation and power grid stability. A wide spectrum of data-driven methods, ranging from linear regression models to more recent deep learning models have been adopted to forecast electric load over the years. However, there still lacks a holistic evaluation of the applicability of conventional statistical and machine learning based algorithms with respect to different temporal and spatial scopes, computational requirements, and sensitivity of model-tuning. Enabled by a large-scale electricity load profile dataset of over 40,000 residential customers in a utility region, we conducted a cross-dimensional analysis of data-driven load forecasting methods. Three regression-based and seven deep learning algorithms with different model configurations were evaluated in terms of their overall and peak load prediction accuracy, and training burdens, across spatial aggregation levels ranging from the transformer, feeder, substation, to neighborhood. We found, first, the load forecasting accuracy is constrained by a predictability boundary, influenced by the forecasting horizon and spatial aggregation level. Specifically, RandomForest, XGBoost, TFT, TSMixer, and TiDE models achieved less than 10 % prediction error for up to 96-h ahead forecasting for district, substation, and feeder levels, while other models struggle at long-horizon predictions; Second, for winter and summer peak load dates, most models were able to predict the peak demand timing within ± 1 h, but the prediction percentage error varied by models, with TFT and TiDE models being the top performers; Third, models with similar prediction accuracy can differ in training burden by an order of magnitude. Therefore, choosing model configurations that balance prediction performance and computational resource is an important practical consideration for large-scale deployment of the machine learning based load forecasting. The outcome of this study can guide researchers and practitioners to choose the proper load forecasting algorithms based on their problem scope, required accuracy, and available resources. The predictability boundary can serve as a benchmark for electricity load forecasting problems with new algorithms and datasets.

Li, Han

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle