Search NASA⌕ Search

SEARCH · Search NASA

Results for “soft lithography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bipolar membrane polarization behavior with systematically varied interfacial areas in the junction region

The palette of applications for bipolar membranes (BPMs) has expanded recently beyond electrodialysis as they are now being considered for fuel cell and electrolysis applications. Their deployment in emerging electrochemical technologies arises from the need to have a membrane separator that provides disparate pH environments and to prevent species crossover. Most materials research for BPMs has focused on water dissociation catalysts and less emphasis has been given to the design of the polycation–polyanion interface for improving BPM performance. Here, soft lithography fabricated a series of micropatterned BPMs with precise control over the interfacial area in the bipolar junction. Polarization experiments showed that a 2.28× increase in interfacial area led to a 250 mV reduction in the onset potential. Additionally, the same increase in interfacial area yielded marginal improvements in current density due to the junction region being under kinetics-diffusion control. A simple physics model based on the electric field of the junction region rationalized the reduction in the overpotential for water dissociation as a function of interfacial area. Finally, the soft lithography approach was also conducive for fabricating BPMs with different chemistries ranging from perfluorinated polymer backbones to alkaline stable poly(arylene) hydrocarbon polymers. These polymer chemistries are better suited for fuel cell and electrolysis applications. The BPM featuring the alkaline stable poly(terphenyl) anion exchange membrane had an onset potential of 0.84 V, which was near the thermodynamic limit, and was about 150 mV lower than a commercially available variant.

25 ENERGY STORAGE↗

Multi-layering of SU-8 exhibits distinct geometrical transitions from circular to planarized profiles

The negative tone photoresist SU-8 permits the creation of micrometer-scale structures by optical lithography. It is also the most used photoresist in soft lithography for the fast-prototyping of microfluidic devices. Despite its importance, the effect of capillary forces on SU-8 multi-layering onto topographical features has not been thoroughly studied. In particular, the profile of the added layer has not been examined in detail. The overlaying process exhibits a set of distinct behaviors, or regimes, depending on the relative thickness of the overlay and the underlying rectangular pattern. We demonstrate how capillary effects control the profile of multi-layer microchannels in a predictable manner. We derive a simple static model to describe the evolution of the overlay as a function of dimensionless geometric parameters. Our study provides a critical understanding of the parameters that govern multi-layer spin coating.

Sauzade, Martin↗

Ceramic Strain Gages for Use at Temperatures up to 1500 Celsius

Indium-tin-oxide (ITO) thin film strain gages were successfully demonstrated at temperatures beyond 1500 C. High temperature static strain tests revealed that the piezoresistive response and electrical stability of the ceramic sensors depended on the thickness of the ITO films comprising the active strain elements. When 2.5 microns-thick ITO films were employed as the active strain elements, the piezoresistive response became unstable at temperatures above 1225 C. In contrast to this, ceramic sensors prepared with 5 microns-thick ITO were stable beyond 1430 C and sensors prepared with 8 microns-thick ITO survived more than 20 hr of operation at 1481 C. Very thick (10 microns) ITo strain gages were extremely stable and responsive at 1528 C. ESCA depth profiles confirmed that an interfacial reaction between the ITO strain gage and alumina substrate was responsible for the high temperature electrical stability observed. Similar improvements in high temperature stability were achieved by doping the active ITO strain elements with aluminum. Several Sic-Sic CMC constant strain beams were instrumented with ITO strain gages and delivered to NASA for testing. Due to the extreme surface roughness of the CMC substrates, new lithography techniques and surface preparation methods were developed. These techniques relied heavily on a combination of Sic and A12O3 cement layers to provide the necessary surface finish for efficient pattern transfer. Micro-contact printing using soft lithography and PDMS stamps was also used to successfully transfer the thin film strain gage patterns to the resist coated CMC substrates. This latter approach has considerable potential for transferring the thin film strain gage patterns to the extremely rough surfaces associated with the CMC's.

Gregory, Otto↗

Soft algebras for leaf amplitudes

Celestial MHV amplitudes are comprised of non-distributional leaf amplitudes associated to an AdS3 leaf of a foliation of flat spacetime. It is shown here that the leaf amplitudes are governed by the same infinite-dimensional soft ‘S-algebra’ as their celestial counterparts. Moreover, taking the soft limit of the smooth three-point MHV leaf amplitude yields a nondegenerate minus-minus two-point leaf amplitude. The two- and three-point MHV leaf amplitudes are used to compute the plus-minus-minus leaf operator product coefficients.

79 ASTRONOMY AND ASTROPHYSICS↗

Functional stimuli-responsive polymers on micro- and nano-patterned interfaces

Micro- and nano-patterned surfaces offer precise control over morphology and chemical composition, enhancing the stability, durability, and functionality of coating materials. When combined with stimuli-responsive polymers, these surfaces gain dynamic adaptability, enabling reversible binding, reusable sensing, and selective molecular capture. Furthermore, while recent review articles have explored various aspects of stimuli-responsive materials, from hydrogel patterns for bioanalytical applications to shape-morphing hydrogels for soft robotics and sensors, a comprehensive review focused on the integration of smart polymers with micro- or nano-patterned interfaces remains absent. This review addresses key surface patterning techniques, including soft lithography, colloidal lithography, and polymer brush photolithography, as well as advances in surface-initiated polymerization methods, such as surface-initiated controlled radical polymerization (SI-CRP). In addition, we discuss recent progress in integrating stimuli-responsive polymers with patterned surfaces to create advanced, functional materials.

Colloidal lithography↗

Fabrication of a novel 3D-printed perfusion bioreactor for complex cell culture models

We introduce a novel fabrication method for developing a 3D-printed perfusion bioreactor (3D-PBR) to facilitate the in situ growth and differentiation of human bone marrow (BM)-derived mesenchymal stem cells (MSCs) while enabling coculture with vascular cells. To recapitulate human physiology, in vitro platforms must incorporate several key features of their native target organ. This often entails a supportive 3D architecture for growing and differentiating multiple human cell types in situ under perfusion. Other essential characteristics include reproducibility, ease of customization, and biocompatibility. Our 3D-PBR combines these features and was fabricated using a biocompatible resin-based polymer, which was 3D-printed, followed by the addition of a permeable membrane to create a coculture microenvironment. MSCs were encapsulated in a collagen-fibrin gel alongside human endothelium within the 3D-PBR. The physical cues that our 3D-PBR provided facilitated the differentiation of MSCs into specific lineages, such as adipocytes and osteoblasts. Immunohistochemistry images demonstrated that cells grown in the 3D-PBR exhibited more physiologically relevant BM perivascular niche markers compared to static culture models. Our method utilizes emerging 3D printing techniques and alternative materials, departing from traditional PDMS-based soft lithography. These advancements in fabrication further enhance in vitro platforms for diverse cell culture models and vascular permeability assays.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic delivery of cutting enzymes for fragmentation of surface-adsorbed DNA molecules

We describe a method for fragmenting, in-situ, surface-adsorbed and immobilized DNAs on polymethylmethacrylate(PMMA)-coated silicon substrates using microfluidic delivery of the cutting enzyme DNase I. Soft lithography is used to produce silicone elastomer (Sylgard 184) gratings which form microfluidic channels for delivery of the enzyme. Bovine serum albumin (BSA) is used to reduce DNase I adsorption to the walls of the microchannels and enable diffusion of the cutting enzyme to a distance of 10mm. Due to the DNAs being immobilized, the fragment order is maintained on the surface. Possible methods of preserving the order for application to sequencing are discussed.

Budassi, Julia↗

Monitoring the impact of confinement on hyphal penetration and fungal behavior

Through their expansive mycelium network, soil fungi alter the physical arrangement and chemical composition of their local environment. This can significantly impact bacterial distribution and nutrient transport and can play a dramatic role in shaping the rhizosphere around a developing plant. However, direct observation and quantitation of such behaviors is extremely difficult due to the opacity and complex porosity of the soil microenvironment. In this study, we demonstrate the development and use of an engineered microhabitat to visualize fungal growth in response to varied levels of confinement. Microfluidics were fabricated using photolithography and conventional soft lithography, assembled onto glass slides, and prepared to accommodate fungal cultures. Selected fungal strains across three phyla (Ascomycota: Morchella sextalata , Fusarium falciforme ; Mucoromycota: Linnemannia elongata , Podila minutissima , Benniella ; Basidiomycota: Laccaria bicolor , and Serendipita sp.) were cultured within microhabitats and imaged using time-lapse microscopy to visualize development at the mycelial level. Fungal hyphae of each strain were imaged as they penetrated through microchannels with well-defined pore dimensions. The hyphal penetration rates through the microchannels were quantified via image analysis. Other behaviors, including differences in the degree of branching, peer movement, and tip strength were also recorded for each strain. Our results provide a repeatable and easy-to-use approach for culturing fungi within a microfluidics platform and for visualizing the impact of confinement on hyphal growth and other fungal behaviors pertinent to their remodeling of the underground environment.

Guo, Yi-Syuan (ORCID:0000000340142225)↗

3D printable silicone compositions exhibiting high toughness and low durometer

3D printable silicones can be designed with varying crosslink density, network structures, and types of reinforcing additives. Within this design space, one may tailor the uncured material’s rheology and mechanical response to access a wide range of potential applications. However, printable, low modulus silicones, particularly those applicable to direct ink write, are underreported in published literature. To address the need for higher performance, low modulus silicones with demonstrated printability, a new set of ca. 20–50 Shore A hardness silicone elastomers exhibiting ca. 7 MPa ultimate tensile strength and ca. 400–1200% elongation at break is presented. Mechanical properties were analyzed, providing insight to the effects of formulation constituents on mechanical properties. Cyclic mechanical testing of the silicone formulations was also performed, and the energy loss and permanent set throughout cycling were determined. In conclusion, printed structures demonstrate the feasibility of these new silicones as durable frameworks for novel soft device applications.

36 MATERIALS SCIENCE↗

The Gene Fitness Atlas: A Roadmap for Predicting Evolution

We developed a novel, high-throughput microfluidic device design containing “interaction zones” where progeny cell lines compete against each other allowing for accurate analysis of bacterial cell fitness. The goal of the project was to use the device for two applications: 1) gene knockout screening and 2) antibiotic resistance screening. The microfluidic platform was fabricated using photolithography and soft lithography in polydimethylsiloxane (PDMS). E.coli Keio mutants and fluorescent wildtype parent were chosen for the study. Cells were grown overnight and their loading into the devices and seeding in mother machines was optimized. For mutant screening, the least fit mutant and wildtype parent were cultured individually and then added to the microfluidic device. The mother machines which were seeded with mutant and wildtype were imaged through time lapse microscopy and the growth of cells was observed. For antibiotic screening, wildtype E.coli cells which were grown overnight were added to the device and washed with media containing the antibiotic ampicillin. The growth pattern in presence and absence of ampicillin was observed through time lapse microscopy. It was observed that over a period of four hours, both the mutant and the wildtype divided in the mother machine and pushed daughter cells out into the interaction zone. In case of the antibiotic screening experiment, the fluorescent wildtype divided both in the absence and presence of sublethal concentration of ampicillin. This study is a proof of concept demonstration of high- throughput single cell analysis of cells using a novel microfluidics device.

59 BASIC BIOLOGICAL SCIENCES↗

Shear Stress Sensing using Elastomer Micropillar Arrays

The measurement of shear stress developed as a fluid moves around a solid body is difficult to measure. Stresses at the fluid-solid interface are very small and the nature of the fluid flow is easily disturbed by introducing sensor components to the interface. To address these challenges, an array of direct and indirect techniques have been investigated with various advantages and challenges. Hot wire sensors and other indirect sensors all protrude significantly into the fluid flow. Microelectromechanical systems (MEMS) devices, although facilitating very accurate measurements, are not durable, are prone to contamination, and are difficult to implement into existing model geometries. One promising approach is the use of engineered surfaces that interact with fluid flow in a detectable manner. To this end, standard lithographic techniques have been utilized to generate elastomeric micropillar arrays of various lengths and diameters. Micropillars of controlled length and width were generated in polydimethylsiloxane (PDMS) elastomer using a soft-lithography technique. The 3D mold for micropillar replication was fabricated using laser ablative micromachining and contact lithography. Micropillar dimensions and mechanical properties were characterized and compared to shear sensing requirements. The results of this characterization as well as shear stress detection techniques will be discussed.

Wohl, Christopher J.↗

Shear Stress Sensing with Elastic Microfence Structures

In this work, elastic microfences were generated for the purpose of measuring shear forces acting on a wind tunnel model. The microfences were fabricated in a two part process involving laser ablation patterning to generate a template in a polymer film followed by soft lithography with a two-part silicone. Incorporation of a fluorescent dye was demonstrated as a method to enhance contrast between the sensing elements and the substrate. Sensing elements consisted of multiple microfences prepared at different orientations to enable determination of both shear force and directionality. Microfence arrays were integrated into an optical microscope with sub-micrometer resolution. Initial experiments were conducted on a flat plate wind tunnel model. Both image stabilization algorithms and digital image correlation were utilized to determine the amount of fence deflection as a result of airflow. Initial free jet experiments indicated that the microfences could be readily displaced and this displacement was recorded through the microscope.

Cisotto, Alexxandra↗

Reducing Ohmic Resistances in Membrane Capacitive Deionization Using Micropatterned Ion-Exchange Membranes, Ionomer Infiltrated Electrodes, and Ionomer-Coated Nylon Meshes

Membrane capacitive deionization (MCDI) is an emerging water desalination platform that is compact, electrified, and does not require high-pressure piping. Herein, highly conductive poly(phenylene alkylene) ion-exchange membranes (IEMs) are micropatterned with different surface geometries for MCDI. The micropatterned membranes increase the interfacial area with the liquid stream leading to a 700 mV reduction in cell voltage when operating at constant current (2 mA cm -2 ; 2000 ppm NaCl feed) while improving the energy normalized adsorbed salt (ENAS) value by 1.4 times. Combining the micropatterned poly(phenylene alkylene) IEMs with poly(phenylene alkylene) ionomer-filled electrodes reduces the cell voltage by 1000 mV and improves the ENAS values by 2.3 times relative to the base case. This reduction in cell voltage allows for higher current density operation (i.e., 3–4 mA cm -2 ) . The reduction in cell voltage is ascribed to the ameliorating ohmic resistances related to ion transport at the membrane-process stream interface and in the carbon cloth electrode. Finally, porous ionic conductors are implemented into the spacer channel with flat and micropatterned IEM configurations and ionomer infiltrated electrodes. For the configuration with flat IEMs, the porous ionic conductor improves ENAS values across the current density regime (2–4 mA cm -2 ), while for micropatterned IEMs it gets improved only at 4 mA cm -2 .

42 ENGINEERING↗

Robotic automation of droplet microfluidics

Droplet microfluidics enables powerful analytic capabilities but often requires workflows involving macro- and microfluidic processing steps that are cumbersome to perform manually. Here, we demonstrate the automation of droplet microfluidics with commercial fluid-handling robotics. The workflows incorporate common microfluidic devices including droplet generators, mergers, and sorters and utilize the robot's native capabilities for thermal control, incubation, and plate scanning. The ability to automate microfluidic devices using commercial fluid handling will speed up the integration of these methods into biological workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Overview of Space Technology developed during 1980s ~ present

Early 1980s, a science team of NASA Langley Research has developed various space power systems, especially directly solar-pumped iodine laser (DSPIL), wireless power transmission technology, concepts of solar thermal propulsion, pulse-power for direct-energy weapons (DEW) applications, soft X-ray lithography and to name a few. This presentation will briefly overview these NASA-Langley developed space technology for future applications.

plasma devices↗

Multilayer and grazing incidence X-ray/EUV optics for astronomy and projection lithography; Proceedings of the Meeting, San Diego, CA, July 19-22, 1992

The present volume on multilayer and grazing incidence X-ray/EUV optics for astronomy and projection lithography discusses AXAF grazing incidence mirrors, the theory and high throughput optics of grazing incidence optics, multilayer mirror fabrication and characterization, and multilayer optics for X-ray projection lithography. Attention is given to the VETA-I X-ray detection system, a motion detection system for AXAF X-ray ground testing, image analysis of the AXAF VETA-I X-ray mirror, and optical constants from mirror reflectivities measured at synchrotrons. Topics discussed include the application of aberration theory to calculate encircled energy of Wolter I-II telescopes, W/C multilayers deposited on plastic films, nonspecular X-ray scattering from Si/Mo multilayers, and multilayer thin-film design as FUV polarizers. Also discussed are thin-film filter lifetesting results in the EUV, chromospheric and coronal observations with multilayer optics, present and future requirements of soft X-ray projection lithography, and the imaging Schwarzschild multilayer X-ray microscope.

Hoover, Richard B.↗

X ray microscope assembly and alignment support and advanced x ray microscope design and analysis

Considerable efforts have been devoted recently to the design, analysis, fabrication, and testing of spherical Schwarzschild microscopes for soft x ray application in microscopy and projection lithography. The spherical Schwarzschild microscope consists of two concentric spherical mirrors configured such that the third order spherical aberration and coma are zero. Since multilayers are used on the mirror substrates for x ray applications, it is desirable to have only two reflecting surfaces in a microscope. In order to reduce microscope aberrations and increase the field of view, generalized mirror surface profiles have been considered in this investigation. Based on incoherent and sine wave modulation transfer function (MTF) calculations, the object plane resolution of a microscope has been analyzed as a function of the object height and numerical aperture (NA) of the primary for several spherical Schwarzschild, conic, and aspherical head reflecting two mirror microscope configurations.

Shealy, David L.↗

Design and analysis of aspherical multilayer imaging X-ray microscope

Spherical Schwarzschild microscopes for soft X-ray applications in microscopy and projection lithography employ two concentric spherical mirrors that are configured such that the third-order spherical aberration and coma are zero. Based on incoherent, sine-wave MTF calculations, the object-plane resolution of a magnification-factor-20 microscope is presently analyzed as a function of object height and numerical aperture of the primary for several spherical Schwarzschild, conic, and aspherical two-mirror microscope configurations.