Characterization, Accelerated Life Testing, and Finite Element Modeling of Low Temperature Solder Wire Interconnect Degradation Mechanisms
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Tin-lead-antimony (50Sn–47Pb–3Sb wt.%) soldered assemblies were mechanically tested approximately 30 years after initial production and found to have solder joints of reduced strength. The microstructure of this solder alloy exhibits a ternary eutectic structure with Sn-rich, Pb-rich, and SnSb phases. Accelerated aging was performed to evaluate solder microstructural coarsening and associated strength of laboratory solder joints to correlate these properties to the “naturally aged” solder joints. Isothermal aging was conducted at room temperature, 55, 70, 100, and 135 °C and aging times that ranged from 0.1 to 365 days. The coarsening kinetics of the Pb-rich phase were determined through optical microscopy and image analysis methods established in previous studies on binary Sn–Pb solder. A kinetic equation was developed with time exponent n of 0.43 and activation energy of 24000 J/mol, suggesting grain boundary diffusion or other fast diffusion pathways controlling the microstructural evolution. Compression testing and Vickers microhardness showed significant strength loss within the first 20–30 days after soldering; then, the microstructure and mechanical properties changed more slowly over long periods of time. Further, by combining accelerated aging data and the microstructure-based kinetics, strength predictions were made that match well with the properties of the actual soldered assemblies naturally aged for 30 years. However, aging at the highest temperature of 135 °C produced anomalous behavior suggesting that extraneous aging mechanisms are active. Therefore, data obtained at this temperature or higher should not be used. Overall, the combined microstructural and mechanical property methods used in this study confirmed that the observed reduction in strength of ~ 30-year-old solder joints can be accounted for by the microstructural coarsening that takes place during long-term solid-state aging.
Solders with superconducting transitions around 4K are useful in low magnetic field environments for AC current leads or in electrical and mechanical bonds. Accurate knowledge of these solders’ superconducting properties is essential for improving high precision experiments. We have measured the electrical resistance of five commercially-available eutectic or near-eutectic solders: 50%Sn-50%Pb, 60%Sn-40%Pb, 60%Sn-40%Pb-0.3%Sb, 52%In-48%Sn, and 96.5%Sn-3.5%Ag, down to 2.3K and in applied magnetic fields from 0 to 0.1 T . We report critical temperatures T c (B), 90%–10% transition widths ΔT c , and zero-temperature critical fields B c,0 . Our best candidate for low-loss AC current wiring in low fields is 50%Sn-50%Pb, which has a zero-field T c,0 = 7.1K (with ΔT c = 0.6 K), and remained high at T c (0.1 T) = 6.9K (ΔT c = 0.6K ). We also report, for the first time, T c and B c of 60%Sn-40%Pb-0.3%Sb and B c,0 of 96.5%Sn-3.5%Ag. Our T c,0 - 3.31K (ΔT c = 0.08K) for 96.5%Sn-3.5%Ag disagrees with a widely adopted value.
Rare-earth barium copper oxide (REBCO) high-temperature superconducting (HTS) magnets can generate very high magnetic fields with superior engineering current density and robust mechanical integrity. The no-insulation (NI) winding technique, including its metal-insulation (MI) variant, enables “self-protection” against localized overheating through inter-turn current sharing, improving defect tolerance and allowing temporary current overloads. In REBCO pancake coils, the current-sharing path is predominantly confined to the edges of the REBCO tapes due to insulating buffer layers. Applying a surface shunt using solder can effectively enhance current sharing in NI/MI coils via the REBCO tape edges. Here, in this paper, we present both experimental and numerical research on the current distribution in surface-shunt metal-insulation (SSMI) REBCO pancake coils. We tested a stainless steel co-wound MI REBCO double-pancake coil, before and after applying a soldered surface shunt, in a saturated liquid nitrogen bath. The SSMI coil was modeled using the H-formulation and rotated anisotropic resistivity to study its dynamic behavior, including inter-turn current sharing and intra-turn screening currents. Benchmarked by experimental data, the numerical model is able to study the defect tolerance of the SSMI coil during energization.
Soldering is a critical filler material joining process found in nearly all modern electronics. Ensuring solder joint reliability is crucial for the safety, performance, and cost-effectiveness of microelectronics.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.
Eutectic alloys, such as Pb-free Bi-Sn-Ag or Sn-Ag-Cu, are essential for their low melting points in solder joints but suffer from brittle intermetallic phases, reducing reliability. Traditional solder design relies on equilibrium phase diagrams, often neglecting the kinetic influence of crystalline anisotropy during solidification. This study hypothesizes that the energetics at the solid-solid-liquid trijunction dictate crystalline facet selection. Using the Al-Al 3 Ni alloy as a model, this project combines atomistic simulations and experimental methods to understand interfacial energies and develop predictive models. This approach aims to mitigate the negative effects of intermetallics, enhancing component reliability in electronic applications.
Brazing and soldering are metallurgical joining techniques that use a wetting molten metal to create a joint between two faying surfaces. Here, the quality of the brazing process depends strongly on the wetting properties of the molten filler metal, namely the surface tension and contact angle, and the resulting joint can be susceptible to various defects, such as run-out and underfill, if the material properties or joining conditions are not suitable. In this work, we implement a finite element simulation to predict the formation of such defects in braze processes. This model incorporates both fluid–structure interaction through an arbitrary Eulerian–Lagrangian technique and free surface wetting through conformal decomposition finite element modeling. Upon validating our numerical simulations against experimental run-out studies on a silver-Kovar system, we then use the model to predict run-out and underfill in systems with variable surface tension, contact angles, and applied pressure. Finally, we consider variable joint/surface geometries and show how different geometrical configurations can help to mitigate run-out. This work aims to understand how brazing defects arise and validate a coupled wetting and fluid–structure interaction simulation that can be used for other industrial problems.
Nuclear fusion is an enticing alternative to current sources of energy, with multilayered Rare-Earth Barium Copper Oxide (REBCO) coated conductors deemed pivotal in the race toward fully realized, commercially viable, and magnetic confinement fusion reactors. In this study, we simulated the ion spectrum expected to evolve from REBCO's nickel-based Hastelloy C-276 substrate and copper stabilizer in an affordable robust compact-like reactor. We then emulated this gas production through helium implantation to investigate changes in materials and superconducting properties. Our results revealed that the substrate and stabilizer are capable of producing protons energetic enough to recoil throughout the tape thickness in appreciable doses, and alphas energetic enough to deposit 7.54 × 1014 ions/cm2 or 50.1 helium appm in the superconducting layer over a 30-year reactor lifetime. The superconducting layer of SuperPower® tapes exhibited at least double the swelling rate of the other major layers, and both SuperPower and Fujikura Ltd. tapes displayed microstructural changes in the REBCO layer not observed in isotropic metals. For the estimated lifetime fluence, the Fujikura tapes showed a ∼1 K reduction in critical temperature and a 32% degradation in critical current for compact reactor-relevant conditions (16 T, 20 K). Nuclear transmutation, low-temperature solder implantations, gas-ion evolution, the influence of gas production on vortex dynamics, and other related considerations are also discussed.
Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.
MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.
The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. Here, this paper presents the assembly process for these five toroidal magnets, detailing critical steps including epoxy application, pin insertion, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.
A finite element model of a 60-cell monocrystalline silicon glass-polymer photovoltaic module was simulated with ±1.0 kPa and ±2.4 kPa loads applied to the glass to calculate the deformation under load. Cell-to-cell displacements were used to approximate interconnect strain and stress. A mathematical fatigue cycle life relation was fitted to data for the interconnect material (copper), to generate a life prediction at each interconnect location based on the local stress means, reversal extents, and amplitudes. Interconnect stress was found to be significantly asymmetric about zero despite symmetric positive and negative module loads due to laminate thickness offsets about the neutral plane and the effects of module framing. Cycle life results indicated that interconnect fatigue failure was unlikely to occur over a 30-year lifetime of conservative wind and snow load cycles since the typical cell design feature of leaving some unconstrained length between the cell edge and first solder pad increases the effective gauge length and decreases the stress levels below the material endurance limit. Follow-up analyses found that 3.6 mm and 6.4 mm were the minimum unconstrained lengths required to survive the assumed lifetime of wind and snow cycles, respectively, confirming that typical industrial module constructions with 8–15 mm unconstrained lengths should survive conservatively. Notably, large magnitude, low-cycle snow loading was consistently the limiting factor requiring a longer unconstrained interconnect length. Finally, insights and workflows from this study inform module interconnection design limits for survival against mechanical fatigue in deployment environments.
The Transition to Wire (TTW) hardware project is a method for connecting solar research samples with fragile interconnects to robust, weatherproof and consistent commercial connectors. The Transition to Wire device is a printed circuit board designed to facilitate the transition from tab ribbon or other unsecured electrical contacts on research samples to either wires or a connector. The four pin connector provides a kelvin (4 wire) connection at the solder pad where the sample connects.