Search NASA⌕ Search

SEARCH · Search NASA

Results for “streaking diagnostic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Optical Streak Diagnostic for Observing Anode-Cathode Plasmas for Radiographic Source Development

National Security Technologies, LLC, and Sandia National Laboratories are collaborating in the development of pulsed power–driven flash x-ray radiographic sources that utilize high-intensity electron beam diodes. The RITS 6 (Radiographic Integrated Test Stand) accelerator at Sandia is used to drive a self magnetic pinch diode to produce a Bremsstrahlung x-ray source. The high electric fields and current densities associated with these short A-K gap pinch beam diodes present many challenges in diode development. Plasmas generated at both the anode and cathode affect the diode performance, which is manifested in varying spot (source) sizes, total dose output, and impedance profiles. Understanding the nature of these plasmas including closure rates and densities is important in modeling their behavior and providing insight into their mitigation. In this paper we describe a streak camera–based optical diagnostic that is capable of observing and measuring plasma evolution within the A-K gap. By imaging a region of interest onto the input slit of a streak camera, we are able to produce a time-resolved one-dimensional image of the evolving plasma. Typical data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compressed Streak Imaging Beam Diagnostic

We are planning a new beam diagnostic based on Compressed Ultrafast Photography (CUP)1.A foil inserted in the beam path is used to generate a continuous optical image of the beam, which is the same technique used on the existing DARHT II beam imaging diagnostic. This existing diagnostic compresses the beam image with anamorphic lenses into four views that are streaked simultaneously on two streak cameras. In our new beam diagnostic design the anamorphic lenses are replaced with regular lenses and the beam image is stamped with a pseudo-random mask pattern. The full image is imaged onto a streak camera with its entrance slit expanded. Modifying the CUP technique, which uses a single streaked image, our design splits the image into four rotated copies and puts all four images on two streak cameras. A data cube of multiple image frames is reconstructed from the streak camera data through the use of the TwiST algorithm2 combined with total variation denoising3. The additional rotated images improve spatial resolution and reduce noise and image artifacts compared to using a single streaked image. In reconstructions of simulated data, fine detail in the beam profile can be seen and there is a remarkable absence of image artifacts compared to the existing DARHT II beam imaging diagnostic. Performance was evaluated using a pseudo-MTF derived from a simulated wave pattern test object.

Marks, Daniel G.↗

Experimental demonstration of attosecond pump–probe spectroscopy with an X-ray free-electron laser

Pump–probe experiments with subfemtosecond resolution are the key to understanding electronic dynamics in quantum systems. Here we demonstrate the generation and control of subfemtosecond pulse pairs from a two-colour X-ray free-electron laser. By measuring the delay between the two pulses with an angular streaking diagnostic, we characterize the group velocity of the X-ray free-electron laser and show control of the pulse delay down to 270as. Here, we confirm the application of this technique to a pump–probe measurement in core-ionized para-aminophenol. These results reveal the ability to perform pump–probe experiments with subfemtosecond resolution and atomic site specificity.

47 OTHER INSTRUMENTATION↗

Surface interactions involved in flashover with high density electronegative gases.

This report examines the interactions involved with flashover along a surface in high density electronegative gases. The focus is on fast ionization processes rather than the later time ionic drift or thermalization of the discharge. A kinetic simulation of the gas and surface is used to examine electron multiplication and includes gas collision, excitation and ionization, and attachment processes, gas photoionization and surface photoemission processes, as well as surface attachment. These rates are then used in a 1.5D fluid ionization wave (streamer) model to study streamer propagation with and without the surface in air and in SF6. The 1.5D model therefore includes rates for all these processes. To get a better estimate for the behavior of the radius we have studied radial expansion of the streamer in air and in SF6. The focus of the modeling is on voltage and field level changes (with and without a surface) rather than secondary effects, such as, velocities or changes in discharge path. An experiment has been set up to carry out measurements of threshold voltages, streamer velocities, and other discharge characteristics. This setup includes both electrical and photographic diagnostics (streak and framing cameras). We have observed little change in critical field levels (where avalanche multiplication sets in) in the gas alone versus with the surface. Comparisons between model calculations and experimental measurements are in agreement with this. We have examined streamer sustaining fields (field which maintains ionization wave propagation) in the gas and on the surface. Agreement of the gas levels with available literature is good and agreement between experiment and calculation is good also. Model calculations do not indicate much difference between the gas alone versus the surface levels. Experiments have identified differences in velocity between streamers on the surface and in the gas alone (the surface values being larger).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recording the synchrotron radiation by a picosecond streak camera for bunch diagnostics in cyclic accelerators

A PS-1/S1 picosecond streak camera with a linear sweep is used to measure temporal characteristics of synchrotron radiation pulses on a damping ring (DR) at the Budker Institute of Nuclear Physics (BINP) of the Siberian Branch of the Russian Academy of Sciences (Novosibirsk). The data obtained allow a conclusion as to the formation processes of electron bunches and their 'quality' in the DR after injection from the linear accelerator. The expediency of employing the streak camera as a part of an optical diagnostic accelerator complex for adjusting the injection from a linear accelerator is shown. Discussed is the issue of designing a new-generation dissector with a time resolution up to a few picoseconds, which would allow implementation of a continuous bunch monitoring in the DR during mutual work with the electron-positron colliders at the BINP. (acoustooptics)

43 PARTICLE ACCELERATORS↗

Qualification of a multi-diagnostic detonator-output characterization procedure utilizing PMMA witness blocks

In this study, experiments were conducted to qualify a multi-diagnostic characterization procedure for the performance output of a detonator when fired into a poly(methyl methacrylate) (PMMA) witness block. A suite of optical diagnostics were utilized in combination to both bound the shock wave interaction state at the detonator/PMMA interface and characterize the nature of the shock wave decay in PMMA. The diagnostics included the Shock Wave Image Framing Technique (SWIFT), a photocathode tube streak camera, and photonic Doppler velocimetry (PDV). High-precision, optically clear witness blocks permitted dynamic flow visualization of the shock wave in PMMA via focused shadowgraphy. SWIFT-and streak-imaging diagnostics captured the spatiotemporally evolving shock wave, providing a two-dimensional temporally discrete image set and a one-dimensional temporally continuous image, respectively. PDV provided the temporal velocity history of the detonator output along the detonator axis. Lastly, through combination of the results obtained, a bound was able to be placed on the interface condition and a more-physical profile representing the shock wave decay in PMMA for an exploding-bridgewire detonator was achieved.

47 OTHER INSTRUMENTATION↗

Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens

The BHx streak tube, under development at the Laboratory for Laser Energetics, incorporates a series of novel electron-optics elements to enable high fidelity measurements for high-energy-density physics experiments. The system is engineered to support a 25-mm active photocathode region compatible with sub-picosecond temporal resolution and with 70% internal photoelectron throughput. It exhibits negligible geometric distortion on a flat output screen, making it well suited for variety of measurements, such as ultrafast x-ray spectroscopy. Here, this paper presents characterization data from a prototype unit tested with an ultraviolet laser in a static deflection (non-swept) mode and shows good agreement with the predictions from numerical modeling, including focusing performance and geometric distortion measurements. Key design elements have been demonstrated and de-risked, laying the foundation for dynamic deflection testing. The anticipated improvements in data fidelity are expected to impact the fields as diverse as inertial confinement fusion, laboratory astrophysics, and materials science.

High energy density physics↗

PS-1/S1 picosecond streak camera application for multichannel laser system diagnostics

A PS-1/S1 picosecond image-tube streak camera (ITSC) with slit scan (streak camera), developed and manufactured at the General Physics Institute RAS, has been used to measure the spatiotemporal characteristics of ultrashort laser pulses generated by a petawatt-power laser installation 'FEMTO' at the Institute of Laser Physics Research in Sarov. It is found that such a camera is suitable for measuring the spatial and temporal parameters of single laser pulses with an accuracy of about one picosecond. It is shown that the intensity time profile of a train of picosecond pulses may be precisely defined for the pulses separated in time by a few picoseconds. The camera allows the contrast of radiation to be determined with a high (no less than 10{sup 3}) accuracy; spatial distribution of the laser pulses can be measured with an accuracy of tens of microns, and the temporal separation of single laser pulses can be identified with an accuracy of 1 – 1.5 ps. (extreme light fields and their applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the LLNL Spectrometer for Possible use with the NSTec Optical Streak Camera as a Light Gas Gun Diagnostic

In fiscal year 2012, it was desired to combine a visible spectrometer with a streak camera to form a diagnostic system for recording time-resolved spectra generated in light gas gun experiments. Acquiring a new spectrometer was an option, but it was possible to borrow an existing unit for a period of months, which would be sufficient to evaluate both “off-line” and in-gas gun shots. If it proved adequate for this application, it could be duplicated (with possible modifications); if not, such testing would help determine needed specifications for another model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a streaked radiography instrument for ICF ablator tuning measurements

A streaked radiography diagnostic has been proposed as a technique to determine the ablator mass remaining in an inertial confinement fusion ignition capsule at peak velocity. This instrument, the 'HXRI-5', has been designed to fit within a National Ignition Facility Diagnostic Instrument Manipulator. The HXRI-5 will be built at Sandia National Laboratories (SNL), and initial testing will be done at the SNL Z-Beamlet Facility. In this paper, we will describe the National Ignition Campaign requirements for this diagnostic, the instrument design, and the planned test experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PBX 9502 air-gap tests

A small number of simple air-gap tests were performed on 1-inch diameter PBX 9502 cylinders to determine an approximate threshold for detonation failure. The primary diagnostics were streak imaging and dent measurements in a steel witness plate. Relight was found to occur, with negligible excess transit time, for air gaps up to 1 mm. Relight did not occur with a 3-mm air gap.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

2D Optical Streaking for Ultra-Short Electron Beam Diagnostics

We propose a novel approach to measure short electron bunch profiles at micrometer level. Low energy electrons generated during beam-gas ionization are simultaneously modulated by the transverse electric field of a circularly-polarized laser, and then they are collected at a downstream screen where the angular modulation is converted to a circular shape. The longitudinal bunch profile is simply represented by the angular distribution of the electrons on the screen. We only need to know the laser wavelength for calibration and there is no phase synchronization problem. Meanwhile the required laser power is also relatively low in this setup. Some simulations examples and experimental consideration of this method are discussed. At Linac Coherent Light Source (LCLS), an S-band RF transverse deflector (TCAV) is used to measure the bunch length with a resolution 10 femtosecond (fs) rms. An X-band deflector (wavelength 2.6cm) is proposed recently to improve the resolution. However, at the low charge operation mode (20pC), the pulse length can be as short as fs. It is very challenging to measure femtosecond and sub-femtosecond level bunch length. One of the methods is switching from RF to {mu}m level wavelength laser to deflect the bunch. A powerful laser ({approx}10s GW) is required to deflect such a high energy beam (GeV) in a wiggler. Synchronization is another difficulty: the jitter between the bunch and the laser can be larger than the laser wavelength, which makes single-shot measurement impossible. To reduce the laser power, we propose to use ionized electrons from high energy electron beam and gas interaction for high energy electron bunch diagnostics. Similarly, the femtosecond X-ray streak camera uses X-ray ionization electrons to measure the X-ray pulse. The electrons generated by beam-gas ionization have low energy (eVs). Therefore, a lower laser power is possible to deflect such low energy electrons. Note that there is no field ionization in our case. To avoid field ionization, which occurs in plasma case, gases species with high field ionization threshold should be considered. For a linear polarized laser, the kick to the ionized electrons depends on the phase of the laser when the electrons are born and the unknown timing jitter between the electron beam and laser beam makes the data analysis very difficult. Here we propose to use a circular polarized laser to do a 2-dimensional (2D) streaking (both x and y) and measure the bunch length from the angular distribution on the screen, where the phase jitter causes only a rotation of the image on the screen without changing of the relative angular distribution. Also we only need to know the laser wavelength for calibration. A similar circular RF deflecting mode was used to measure long bunches. We developed a numerical particle-in-Cell (PIC) code to study the dynamics of ionization electrons with the high energy beam and the laser beam.

43 PARTICLE ACCELERATORS↗

Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)

We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional and multichannels multi-imaging x-ray streak camera for imploded core plasma of shell-cone target

Recently one-dimensional and multichannels multi-imaging x-ray streak camera (1D+McMIXS) has been proposed as an ultrafast diagnostic tool for imploded core plasma of shell-cone target. This diagnostic system can provide much more information of core plasma dynamics, such as the shell trajectory before the maximum compression, two dimensional (2D) x-ray images, and 2D map of electron temperature. The 1D+McMIXS was used in an implosion experiment of a shell target with a cone for fast ignition at Gekko XII laser facility. The interaction between the core plasma and the tip of the cone was observed and revealed some detailed structures. A series of time-resolved 2D x-ray images were reconstructed and a nominal temperature evolution was also mapped.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments and simulations of isochorically heated warm dense carbon foam at the Texas Petawatt Laser

An experimental and simulation study of warm dense carbon foams at ambient density (n e ~10 21 cm –3 ) is presented. This study of isochorically heated foams is motivated by their potential application in carbon-atmosphere white-dwarf envelopes, where there are modeling uncertainties due to the equation of state. The foams are heated on an approximately picosecond time scale with a laser-accelerated proton beam. The cooling and expansion of the heated foams can be modeled with appropriately initialized radiation-hydrodynamics codes; xRAGE code is used in this work. The primary experimental diagnostic is the streaked optical pyrometer, which images a narrow band of radiation from the rear surface of the heated material. Presented are xRAGE modeling results for both solid aluminum targets and carbonized resorcinol-formaldehyde foam targets, showing that the foam appears to cool slowly on the pyrometer because of partial transparency. So that simulations of cooling foam are processed properly, it is necessary to account for finite optical depth in the photosphere calculation, and the methods for performing that calculation are presented in depth.

36 MATERIALS SCIENCE↗

Multiframe, Single Line-of-Sight X-Ray Imager for Burning Plasmas

The purpose of this LDRD project was to demonstrate high spatial and temporal resolution x-ray imaging using optical detectors, and in particular the VISAR and OHRV diagnostics on the OMEGA laser. The x-ray source being imaged was a backlighter capsule being imploded by 39 beams of the OMEGA laser. In particular this approach utilized a semiconductor with the side facing the backlighter capsule coated with a thin aluminum layer to allow x rays to pass through the metal layer and then get absorbed in the semiconductor. The other side of the semiconductor was AR coated to allow the VISAR or OHRV probe beam to sample the phase change of the semiconductor as the x rays were absorbed in the semiconductor. This technique is capable of acquiring sub-picosecond 2-D or 1-D x-ray images, detector spatial resolution of better than 10 um and the ability to operate in a high neutron flux environment expected on ignition shots with burning plasmas. In addition to demonstrating this technique on the OMEGA laser, several designs were made to improve the phase sensitivity, temporal resolution and number of frames over the existing diagnostics currently implemented on the OMEGA laser. These designs included both 2-d imaging diagnostics as well as improved 1-D imaging diagnostics which were streaked in time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗