PBX 9502 air-gap tests
Abstract
A small number of simple air-gap tests were performed on 1-inch diameter PBX 9502 cylinders to determine an approximate threshold for detonation failure. The primary diagnostics were streak imaging and dent measurements in a steel witness plate. Relight was found to occur, with negligible excess transit time, for air gaps up to 1 mm. Relight did not occur with a 3-mm air gap.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Dickson, Peter, Novak, Alan M., Foley, Timothy J., Campbell, Christopher Charles. 2017-06-29. PBX 9502 air-gap tests. https://doi.org/10.2172/1367819. https://searchnasa.com/record/osti%3A1367819/pbx-9502-air-gap-tests