Search NASA⌕ Search

SEARCH · Search NASA

Results for “subsurface corrosion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamic and static corrosion of chromium-alumina refractory in simulated nuclear waste glass

Monofrax® K-3, a chromium–alumina refractory, is widely used in nuclear waste glass melters due to its high durability. However, aggressive vitrification conditions still lead to corrosion that limits melter lifespan. Here, this study investigates two key corrosion modes, subsurface and melt-line corrosion, under static and dynamic conditions, using a custom setup enabling precise control of melt velocity and temperature. Experimental results, interpreted using diffusion-limited dissolution models, show that (i) subsurface corrosion increases by approximately 10% per mm/s increase in melt velocity, while melt-line corrosion remains virtually unaffected, (ii) corrosion rate dependence on temperature is inversely proportional to melt viscosity, and (iii) glass composition affects both corrosion modes similarly, based on Cr 2 O 3 , Al 2 O 3 , and alkali contents. The experimental data also allowed the determination of diffusion coefficients of major dissolving species, which were found to be consistent between the melt-line and subsurface corrosion models, indicating their suitability for future CFD studies.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

3013 Baseline Inner Container Report: Description, Imaging, and Analysis

This report presents consolidated findings from three microscopy studies of baseline Bagless Transfer Containers (BTCs), which are the inner containers used in DOE Standard 3013-compliant plutonium storage packages. The studies were conducted by Los Alamos National Laboratory (LANL), Savannah River National Laboratory (SRNL), and DNV, a subcontractor specializing in corrosion science. The baseline BTCs examined had not been exposed to corrosive environments, serving as control samples for comparison with destructively examined (DE) containers. Additionally, the Background section provides an overview of the BTC design, including manufacturing methods, material properties, and container configurations that may influence corrosion behavior. The primary objective of the LANL and SRNL studies was to establish reference characteristics of BTCs to distinguish manufacturing artifacts from corrosion-induced features observed in DE containers. Both laboratories used advanced microscopy techniques, including Wide Area Microscopy (WAMS), Laser Confocal Microscopy (LCM), Scanning Electron Microscopy (SEM), and Focused Ion Beam (FIB), to reveal that most surface anomalies were shallow and attributable to flow-forming processes, not corrosion. Subsurface impurities, identified as non-metallic inclusions, were also observed. DNV’s investigation focused on characterizing the mechanical and chemical properties of the BTC material to support crack growth modeling. Their findings indicate higher hardness and strength but reduced ductility—consistent with flow-formed 304L stainless steel and a higher-than-expected martensite content, in contrast to manufacturer claims. Ongoing and future studies, including Electron Backscatter Diffraction (EBSD), aim to further understand the microstructural factors influencing crack initiation and propagation. The combined studies provide a crucial baseline for distinguishing corrosion effects in DE containers, contributing to the safe and reliable long-term storage of plutonium-bearing materials.

36 MATERIALS SCIENCE↗

Modeling Marangoni Convection using a Velocity-Time Relationship

The Waste Treatment and Immobilization Plant (WTP) at the U.S. Department of Energy’s (DOE’s) Handford site is designed to treat 56 million gallons of radioactive waste through vitrification. The melting vessels physical and chemical integrity is essential to maintain, as failure has a high safety and financial penalty. Monofrax® K-3 refractory, the material widely used for the melting vessel, undergoes significant corrosion over time, concentrated at the triple-point junction between the gaseous atmosphere, refractory, and glass melt, producing a characteristic neck-like profile that significantly limits refractory service life. Accurate prediction of the corrosion within the melter can be used to prevent this and extend the lifetime of the melters. A computational fluid dynamics (CFD) model was previously developed, and predicted subsurface refractory corrosion, but failed to predict the neck-line profile observed experimentally. To address this limitation, the glass-melt meniscus geometry at the glass-refractory interface was estimated from experimentally measured neck profiles and wettability experiments. A curve was fitted to the neck profile to identify the triple point location, and the meniscus shape was characterized by a contact angle of 1°. A velocity profile accounting for Marangoni convection-driven corrosion was derived from the estimated meniscus geometry. Surface tension measurements from LORPM14R1 glasses of varying composition were coupled with K-3 coupon dissolution rates to establish a surface tension–time relationship. This analytical velocity-time model was integrated into the existing CFD framework to improve prediction of the neck corrosion profile. Work was done in a computational setting with national collaboration, resulting in professional development through presentational and technical writing growth.

36 - MATERIALS SCIENCE↗

Under the microscope: Reduced activation ferritic martensitic steel Eurofer-97 following ion-Irradiation and high-temperature high-pressure water exposure

Here, this study is designed to characterise the microstructural behaviour of Eurofer-97 steel under ion irradiation and subsequent exposure to high-temperature high-pressure (HTHP) water. Eurofer-97, a ferritic-martensitic steel, has been developed to withstand the conditions of fusion reactors in the locations in contact with coolant with an elevated level of neutron flux, such as the breeder-wall blanket. The material has been studied after self-ion irradiation (using Fe ions) simulating the microstructural effects of neutron irradiation limited to the subsurface layer. The corrosion properties of the Eurofer-97 steel were studied by exposure to HTHP water up to 331 °C. Advanced microstructural characterisation using scanning, transmission electron and focused ion beam microscopy was performed on the as-received microstructure and after ion irradiation. This was then characterised after exposure for 240 h in high-temperature water. Eurofer-97 had a dense, columnar Cr-rich inner oxide, followed by a Fe-rich outer oxide layer. In the irradiated condition the grain structure and oxide itself was less ordered. No appreciable difference in oxide thickness was identified between the irradiated and unirradiated specimens after this short exposure time.

36 MATERIALS SCIENCE↗

Unusual layer-by-layer growth of epitaxial oxide islands during Cu oxidation

Elucidating metal oxide growth mechanisms is essential for precisely designing and fabricating nanostructured oxides with broad applications in energy and electronics. However, current epitaxial oxide growth methods are based on macroscopic empirical knowledge, lacking fundamental guidance at the nanoscale. Using correlated in situ environmental transmission electron microscopy, statistically-validated quantitative analysis, and density functional theory calculations, we show epitaxial Cu 2 O nano-island growth on Cu is layer-by-layer along Cu 2 O(110) planes, regardless of substrate orientation, contradicting classical models that predict multi-layer growth parallel to substrate surfaces. Growth kinetics show cubic relationships with time, indicating individual oxide monolayers follow Frank-van der Merwe growth whereas oxide islands follow Stranski-Krastanov growth. Cu sources for island growth transition from step edges to bulk substrates during oxidation, contrasting with classical corrosion theories which assume subsurface sources predominate. Our results resolve alternative epitaxial island growth mechanisms, improving the understanding of oxidation dynamics critical for advanced manufacturing at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Review on Geothermal Energy and HPHT Packers for Geothermal Applications

Energy is an essential component for prosperity, economic growth, and development and has become a basic necessity for humans, but at the same time, it has an impact on the environment. Therefore, it is believed that, in the coming future, renewable energy will play an important part in fulfilling the energy demand. In that respect, geothermal energy will be vital as it is a continuous source of energy that is not affected by metrological conditions and can be used in power generation or domestic heating. Many countries around the globe are actively producing energy from geothermal resources. However, the extraction of the heat from the subsurface comes with challenges such as subsurface environment, wellbore instability, corrosion, loss of circulation, and cementing operation. However, one of the most challenging and critical tasks is the zonal isolation of the geothermal well. A packer is a tool that is used for the zonal isolation of a well, and at high pressure and high temperature (HPHT) conditions, which is common for geothermal wells. Most of the components of packers fail, causing well integrity issues. This paper gives a review of the forces acting on packers, testing standards, problems encountered by a packer in the HPHT subsurface environment, and designs to overcome those problems.

15 GEOTHERMAL ENERGY↗

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE). Pulsed infrared thermography (PIT) is a non-contact, one-sided NDE method that allows for imaging of internal defects in arbitrary size and shape metallic structures using heat transfer. PIT imaging is performed using compact instrumentation consisting of a flash lamp for deposition of a heat pulse, and a fast frame infrared (IR) camera for measuring surface temperature transients. However, limitations of imaging resolution with PIT include blurring due to heat diffusion, sensitivity limit of the IR camera. We demonstrate enhancement of PIT imaging capability with unsupervised learning (UL), which enables PIT microscopy of subsurface defects in high strength corrosion resistant stainless steel 316 alloy. PIT images were processed with UL spatial–temporal separation-based clustering segmentation (STSCS) algorithm, refined by morphology image processing methods to enhance visibility of defects. The STSCS algorithm starts with wavelet decomposition to spatially de-noise thermograms, followed by UL principal component analysis (PCA), fine-tuning optimization, and neural learning-based independent component analysis (ICA) algorithms to temporally compress de-noised thermograms. The compressed thermograms were further processed with UL-based graph thresholding K-means clustering algorithm for defects segmentation. The STSCS algorithm also includes online learning feature for efficient re-training of the model with new data. For this study, metallic specimens with calibrated microscopic flat bottom hole defects, with diameters in the range from 203 to 76 µm, were produced using electro discharge machining (EDM) drilling. While the raw thermograms do not show any material defects, using STSCS algorithm to process PIT images reveals defects as small as 101 µm in diameter. To the best of our knowledge, this is the smallest reported size of a sub-surface defect in a metal imaged with PIT, which demonstrates the PIT capability of detecting defects in the size range relevant to quality control requirements of LPBF-printed high-strength metals.

36 MATERIALS SCIENCE↗

Autonomous Infrared and Small (Wide) Angle X-Ray Scattering (IR-S(W)AXS) Capability

Thin water films are 2-D, nanoconfined layers that form on solid surfaces exposed to humid atmospheres—environments ubiquitous across catalysis, corrosion science, soil science, and subsurface geochemistry. At relative humidity (RH) values below saturation, these films are Å–nm thick and exhibit properties that differ sharply from bulk water, including disrupted H-bonding and impeded mass transport. Owing to their high surface-to-volume ratio, dissolution of the solid can rapidly drive strong supersaturation with respect to secondary phases. Reactivity in thin water films is highly sensitive to film thickness, and critically, thickness evolves during reaction because the hygroscopicity of the interfacial system changes as ions accumulate or diminish in the film and as reaction products transform. To accurately probe and control these dynamics, a capability is needed that can measure and automatically maintain a constant water-film thickness while simultaneously monitoring solid dissolution, nucleation, and growth. This project developed an autonomous Infrared/Small Angle X-ray Scattering-Wide Angle X-ray Scattering (IR/(W)SAXS) for investigating reactivity in thin water films on solid surfaces exposed to humidified gases. The capability consists of an IR spectrometer, a (W)SAXS instrument, and a mass flow controller system for generating variably humidified gas flows to a custom reaction cell. Progress on each of the major components of the capability are detailed below.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Destructive Examination Protocol for 3013-Container-Package Storing Plutonium-Bearing Materials

The 3013-container-package consists of a convenience, inner and outer container and is used for long-term storage of plutonium-bearing materials. A destructive examination (DE) protocol has been developed to examine the container package visually and with microscopic aid to find any corrosion conditions that could result in the loss of the integrity of the container package over its lifetime. The DE protocol contains three main steps: initial container examination, helium (He) leak testing, and detailed imaging and analysis of the inner container closure weld region (ICCWR). The ICCWR has been determined to be bounding, defined as exhibiting worst case conditions for stress corrosion cracking (SCC) of the inner container. To assess SCC in the ICCWR, the inner container lid is cut into quarters and the weld and He-leak testing gasket are removed. Then a citric acid wash is performed to remove adherent chlorides from the ICCWR. The wash is then sent for analysis to determine the concentration of chlorides in the ICCWR. While the analysis for chloride concentration is being performed, the quarter sections are further sectioned into 1/8th subsections by cutting each section in half. These subsections are washed using nitric acid to remove corrosion products. Then each subsection is imaged using a Wide Angle 3-D Measurement System (WAMS). After analysis of microscope images for potential SCC, additional imaging can be performed, including subsurface imaging. After review, a determination is made of whether the container integrity may potentially affect the safe storage of the material.

container↗

Corrosion characteristics of monolithic SiC materials in beryllium-bearing molten fluoride salt

In this work, chemical vapor deposited SiC single crystal and polycrystals were exposed to a static beryllium-bearing molten fluoride salt, 2LiF–BeF 2 for 500 and 1000 h at 750 °C. Overall, the single crystal and polycrystalline SiC materials experienced slight weight loss and nominal surface etching regardless of the material type. Localized pitting and nonuniform Si removal from surface regions were associated with trace metal impurities and oxygen. Cross-sectional observation revealed minimal subsurface changes in the microstructure. The corrosion damage processes were similar to those reported for molten LiF–KF–NaF salt with trace impurities, indicating that the impurities significantly affect SiC corrosion.

36 MATERIALS SCIENCE↗

Establishing a Design Strategy for Corrosion Resistant Structural Materials in Molten Salt Technologies

To address the gap in material design strategies for structural components in molten salt-powered technologies, the current work aimed to identify key parameters governing corrosion induced degradation of materials during exposures in molten halide salts. The applicability of the data on dissolution rates of pure metals (e.g., Cr) in a given molten salt to enable predictions of corrosion behavior of multicomponent binary and ternary Fe-based model and Ni-based commercial alloys isothermally exposed in the purified KCl-MgCl 2 in quartz capsules at 700 and 800°C was evaluated. The influence of alloy chemistry on initial dissolution rates and the consequent impact on the time-dependent corrosion induced microstructural evolution in the alloy subsurface was predicted with a coupled thermodynamic-kinetic model. Finally, the model was well able to predict the Cr depletion in all investigated alloys demonstrating the ability of the proposed approach to enable a unique design strategy for structural materials in molten salts.

36 MATERIALS SCIENCE↗

Evaluate Compatibility of Alloy 244 in NaCl-MgCl 2

Alloy 244 is a potential material of interest for molten salt reactor (MSR) developers employing molten chloride as fuel and coolant salts because of its improved mechanical properties compared to the austenitic stainless steel 316H and the Ni-base alloy Hastelloy-N. However, data are limited on the corrosion behavior of alloy 244 in molten chloride salts. Experimental data on the corrosion behavior of 244 in chloride salts will provide valuable data to MSR developers while simultaneously aiding in improving mechanistic understanding of the role of salt chemistry, alloying constituents and microstructure of 244. This task evaluated the compatibility of alloy 244 in two different eutectic NaCl–MgCl 2 salt mixtures. Similar corrosion behavior in terms of depths of attack and compositional changes in the alloy subsurface was observed after exposure in both salts for 500 h at 750°C. However, severe corrosion attack was observed after 500 h at 850°C in one of the chloride salt mixture. This was most likely due to the combined effects of the differences in the two salt chemistries, distinct microstructure of 244 at 850°C compared to 750°C, and the temperature dependence of the chemical interactions (thermodynamic and kinetic) between the alloying constituents.

36 MATERIALS SCIENCE↗

High-Temperature Aquifer Thermal Energy Storage (HT-ATES) Projects in Germany and the Netherlands—Review and Lessons Learned

Aquifer thermal energy storage (ATES) is a concept that can help to address heating and cooling needs through the use of the subsurface as a seasonal thermal energy storage (STES) system. Over 2800 ATES systems have been deployed with storage temperatures typically below 25 °C and only a few with higher temperatures (>40 °C), which would increase the energy density and utility of the stored thermal fluids. Until now, only a few high-temperature aquifer thermal energy storage (HT-ATES) projects have been initiated and are still in operation. These HT-ATES projects have encountered a range of technical and non-technical challenges. This study reviews ten such projects: four in Germany and six in the Netherlands. The non-technical issues include public acceptance, a lack of regulatory framework for these systems, managing overlapping uses of the subsurface, managing changes with the providers and off-takers of thermal energy, and obtaining financing to implement these projects. Common technical issues include geological factors such as incomplete characterization of the subsurface and reservoir heterogeneity; geochemical issues such as mineral scaling, corrosion, and biofouling; lower than expected thermal recovery; and issues with system design and reliability. This review highlights benefits and challenges faced by HT-ATES projects with the goal to use the lessons learned to improve the siting, design, development, and operation of such systems. Recommendations include improved initial subsurface site characterization, use of coupled process models to optimize system design and predict system performance, cascaded uses of stored thermal energy to better utilize the stored heat, monitoring networks to provide feedback on system performance, and expanded system scale to allow for continued operation even when maintenance of some system components is required. Techno-economic modeling and risk analysis could be used to optimize such HT-ATES project design and identify key factors that will affect sustained economic viability. In addition, design flexibility is important for these systems to allow for changing conditions regarding the supply and demand of thermal energy. Adopting these findings should improve the performance and reduce the risks for future HT-ATES projects worldwide.

15 - GEOTHERMAL ENERGY↗

Uranium-hydrogen reaction mechanism and numerical model

We have developed a numerical model to help predict lifetimes of uranium parts in situations where the uranium surface is exposed to hydrogen in the gas headspace. Assessments can be made based on hydrogen pressure and on an upper limit of size of a surface breached hydride spot (volume of hydride corrosion product produced). The model assumes development of a hydride nucleus at a single arbitrary subsurface location associated with an arbitrary surface defect and follows the development of the hydride nucleus to the break-through phase and further growth to the upper limit of acceptable volume of corrosion product. The model has been developed from an understanding of the hydriding mechanism outlined below in 10 steps and measured rates of hydrogen ingress at several types (chemically) of uranium surfaces at ambient temperature and variable pressure. The key points are 1) that the hydrides nucleate only at locations where a surface defect allows hydrogen ingress (reactant delivery) into the uranium metal subsurface (beyond the oxide), and 2) that the hydrides which eventually reach surface break-through status, nucleate and grow in the near surface (few 10s of micron depth maximum) – those beyond ~50 micron have arrested growth and never reach break-through status.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The subsurface structure of abraded Al–Zn–Mg–Cu alloy

Surface abrasion has been shown to introduce heavy shear stress and produce a few hundred nanometers thick altered surface layer (ASL) on Al alloys. Such ASLs exhibit microstructural changes at room temperature and different corrosion resistance than the underlying substrate. Here, we report how sample dimensions and temperature affect the deformed subsurface microstructure evolution on an abraded Al–Zn–Mg–Cu alloy using transmission electron microscopy (TEM) and atom probe tomography. The ASL microstructure evolves differently in the bulk sample than in the thin TEM specimen. In the freshly abraded ASL, the original η'/η precipitates and grain boundaries were deformed toward the abrasion direction. After 7-day natural aging of the freshly abraded bulk sample, well-defined subgrains formed locally in the ASL, and unusual Al 2 Cu (θ) and Mg x Zn y phases precipitated at the subgrain boundaries. However, during natural aging of this TEM specimen taken from the abraded and aged bulk samples, much faster changes occurred, including the continued formation of subgrains and θ particles in the entire ASL, and the diffusion of Zn atoms out of Mg x Zn y particles to form a Zn particle. On the other hand, no obvious microstructural changes occurred in the ASL during 3-month natural aging of the TEM specimen immediately taken from the freshly abraded sample. Finally, this work advances the understanding of how Al alloy microstructures respond during and following any shear deformation, and complex and unexpected effects of sample dimensions on the behavior.

36 MATERIALS SCIENCE↗

Geochemical and Microbial Dynamics of Hydrogen in a Methane Storage Reservoir

Hydrogen has been identified as a flexible energy carrier with zero or negative emission across multiple energy systems, and existing natural gas infrastructure could be leveraged if hydrogen gas (H2) was blended with methane (CH4). For example, subsurface methane storage reservoirs could be slightly modified to also store hydrogen if a methane/hydrogen blend were injected. However, the compatibility of methane storage reservoirs to include H2 injection has not been fully demonstrated, and this could lead to geochemical and microbiological reactions that alter the reservoir and stored gas content. It is essential that we understand the impact of H2 gas on the biogeochemistry of subsurface storage reservoirs before deploying large-scale H2-CH4 storage, We collected produced fluid from two separate methane storage reservoirs in the Southwestern US. First, we completed a baseline analysis of the biogeochemistry through qPCR, 16S rRNA sequencing, metagenomic sequencing, and geochemical analysis. Each reservoir was found to have unique geochemical conditions and a unique microbial community structure, with Site 1 having a higher TDS and an abundance of Shewanella and Site 2 having a lower TDS and high abundance of Eubacterium and Acetobacterium. Next, we ran a series of high pressure, high temperature reactors under hydrogen storage conditions with the biological sample from one of the storage reservoirs and a 20% H2-80% CH4 gas blend for up to 7 days. Our results show a decrease of hydrogen by 5% in reactors as early as 1-3 days. Previous hydrogen storage work has linked subsurface microorganisms with methanogenesis hydrogen sulfide production, acid production, and microbial corrosion. Our results show minimal change in the fluid chemistry, with the exception of a decrease in dissolved sulfate concentrations. Taxonomic sequencing demonstrated the presence of microorganisms capable of iron redox, acid generation, and hydrogen sulfide production throughout the reactors, suggesting microbial hydrogen consumption may occur through various metabolic pathways. This work demonstrates that site-specific geochemistry and microbiology may impact the efficiency of hydrogen storage in methane storage reservoirs.

environmental microbiology↗

Characterization of Contaminants and Mobility in WMA A-AX Boreholes D0006 and D0008

This study was initiated to determine if subsurface contaminants in the A-AX vadose zone at the Hanford site (boreholes D0006 and D0008) caused corrosion of nearby stainless steel well casings (299-E-24-19, 299-E25-46, and 299-E25-236) and, based on the type and distribution of contaminants, determine if contaminants are from one or more sources including a) the A-104 and/or A-105 tanks, b) the 242A evaporator, and c) the 200-E-286 ditch. A tiered approach was used for characterizing contaminants in vadose zone sediments starting with mobile and total contaminant concentrations (Tier 1), characterizing contaminant speciation (Tier 2), and measuring contaminant leaching (Tier 3). Total and mobile contaminant measurements at seven depths showed elevated sulfate and nitrate in all samples (130 to 280 ft depth), elevated chloride in five depths, and no elevated radionuclides except I-129 in D0006 at 206 to 208 ft depth. If these contaminants were initially acidic, stainless-steel corrosion would occur. However, because sediments likely have a high acid neutralization capacity, an acidic spill would have been neutralized within tens of feet, so casing corrosion would likely occur in shallow sediments. GEL labs data also shows low (but above natural) chromate from shallow to 170 ft depth, then higher chromate to 280 ft, suggesting a surface Cr spill or casing corrosion. GEL labs data also showed evidence of more than one plume, with deep nitrate, sulfate, and chloride migration, but only shallow tritium migration. Tritium should migrate nearly unretarded in the subsurface like nitrate and chloride. Elevated aqueous cations and anions in the D0006 206 to 208' depth pore water (SO 4 2- , NO 3 - , Na + , K + , Ca 2+ , Mg 2+ , Si) could be the result of acid disposal and calcite dissolution at shallow depth, with deeper migration of SO 4 2- , NO 3 - from acids and Ca 2+ and Mg 2+ from calcite. Elevated Si (160 mg/L) indicates dissolution of clays or other silicates, which can also occur in acids. Acid extractable metals did show elevated Cr (but not Fe, Ni, Mo, and Mn) above natural levels, which may indicate stainless-steel well corrosion or transport of metals from a shallow spill. The elevated I-129 in D0006 at 206 to 208' depth was low with 0.34 μg/g in pore water and 1.5 μg/g total extractable I-129 in the sediment, which indicates significant fraction of I-129 was bound in one or more precipitates. Although total I-129 was below detection limits in most extractions due to high molybdate interference, I-127 analysis provided some insight into potential precipitate phases. Total I-127 was mainly extracted by acetate or acetic acid (67%), which may be iodine in calcite. Inorganic carbon measurement identified 1.65% calcite, and total organic carbon (TOC) was below detection limits, so iodine was not associated with organic matter. Nearly all the I-127 was present as iodide. In 1-D leach experiments, I-127 as iodide leached from the sediment within 2 pore volumes. Due to high and dynamic molybdate leaching from the sediment and interference with I-129 analysis, there were few quantifiable I-129 measurements. The calculated molybdate release rates from the sediment suggested Mo was being released from the same precipitate phase, such as molybdate incorporated into calcite. Overall, because there was little radioactive contamination measured in D0006 and D0008 boreholes, potential releases from A-104 and A-105 did not reach this location south of the A tank farm. Elevated cations and anions found in D0006 and D0008 at depth as the result of acidic disposal could cause shallow stainless steel casing corrosion. The nearby 242A evaporator generally contained alkaline waste and tritium, but the nearby 200-E-286 ditch generally contained high Cl - liquid effluent, so these are unlikely to be acidic sources.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗