Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchronous machine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Brushless Excitation for Wound-field Synchronous Machines using Multi-harmonic Windings

Wound-field synchronous machines (WFSM) are promising alternatives to electric machines with permanent magnets (PM). The ability to control the rotor field in these machines makes them well-suited to safety critical applications, while the absence of rare-earth permanent magnets makes these machines sustainable. The WFSM rotor excitation schemes have traditionally used carbon brushes, which significantly reduces the reliability of these machines, limiting their widespread adoption. To overcome this limitation and improve the reliability of WFSMs, several brushless rotor excitation schemes have been developed. However, most of these systems require additional windings or dedicated power electronics, making them expensive and limiting achievable power-density. In this paper a new brushless excitation scheme is proposed. In this scheme, a multiphase, multi-harmonic stator winding is designed. This winding can independently control two spatial harmonics in the airgap of the machine; the first to create torque and the second to wirelessly transfer power to the rotor to excite it.

Gadiyar, Nishanth [ORNL] (ORCID:0000000348267524)↗

Virtual Synchronous Machine Grid-Forming Inverter Model Specification (REGFM_B1)

This report describes a generic virtual synchronous machine (VSM) grid-forming inverter (GFM) model - REGFM_B1. The initial model specification was proposed by Pacific Northwest National Laboratory (PNNL), General Electric (GE), and Electric Power Research Institute (EPRI). Siemens Gamesa Renewable Energy (SGRE) also provided inputs to the specification. The model specification has been revised multiple times based on the discussions between all the contributors listed in this report. This work was funded by the Universal Interoperability for Grid-Forming Inverters (UNIFI) Consortium. This generic model is developed to help the utility industry understand the concept of VSM GFMs. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment mature and improve, generic models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Machine Governor

This paper introduces the development of a high-fidelity gas turbine governor model using a programmable logic controller for power-hardware-in-the-loop (PHIL) validation. The governor model is integrated with the National Renewable Energy Laboratory's (NREL) PHIL test bed, featuring a 2-MVA synchronous machine and a 2.5-MW variable-speed drive, to emulate NG-driven HRSGs and CTs under various operational scenarios. The primary objective of this research is to study the grid-connected and islanding operations of conventional generation sources, with representative startup sequences including turbine purge, ignition, speed ramp-up, synchronization, and breaker closure. Preliminary results of the generator governor model on NREL PHIL platform, particularly using the 2.5-MW dynamometer system, offered significant insights into the modeling techniques, hardware integration, scaling, and real-world simulation dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Propulsion System Design using a Dual 3-Phase PM Synchronous Reluctance Machine with X-Type Multi-Level GaN Inverter

— A propulsion system design is exhibited here that comprises of an X-type GaN power module based dual multi-level inverter and a PM Synchronous Reluctance motor. With the critical benefits of multi-level operation, namely low common mode EMI noise, low switching loss, low current Total Harmonic Distortion (THD), smoother torque and lower iron loss, this topology targets high system-level efficiency and high power density while using reduced rare earth (RE) elements in its motor. General Motors and Purdue University jointly designed and developed this 800V class, highly scalable traction drive that can deliver 200+ kW of power suitable for C-SUV to truck vehicle class. The 3-phase electric machine design utilizes dual winding with 6 terminals to work in line with the GaN X-type inverter, and results in a tractive solution that ensures higher machine efficiency while reducing cost and uncertainty related to use and availability of heavy rare earth/rare earth elements in its rotor.

MOMEN, FAIZUL [General Motors LLC, Detroit, MI (Un↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind Power as a Virtual Synchronous Generator (WindVSG)

This project investigated the theory, implemented it in hardware, and validated the Wind as a Virtual Isochronous Generator (WindVSG) concept by combining the advantages of modern dynamic inverter technologies with static, dynamic, and transient electromechanical properties of synchronous machines. During this project we demonstrated how to control the inverters of wind turbine generators (wind alone or in parallel with other GFM sources, such battery energy storage) so that wind power behaves like a synchronous machine-based power plant with a conventional prime mover. For this purpose, testing was conducted at NLR ARIES facility with real 2.5 MW wind-turbine generator operating in GFM mode under dynamic and transient conditions. The team also developed models and conducted simulations for GFM wind power to evaluate stability impacts of GFM operation on power grid. This report describes efforts by the NLR team working in collaboration GE Vernova during 3-year project.

17 WIND ENERGY↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs: Preprint

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, for small-scale radial microgrids, we demonstrate the ability of IBRs to tune the effective transfer functions of synchronous machines. This enables us to relax the uniform turbine time-constant assumptions and widen the scope of existing synchronization results for proportionally heterogeneous machines.

frequency-shaping control↗

Field Emission Current Transfer for Homopolar Machines

With the increasing electrification of transportation, the need for high power density electric machines is higher than ever. The required specific power for the more demanding applications, such as airplane propulsion, is over 20 kW/kg for multi-megawatt range power levels. Fully superconducting synchronous machines could reach the required performance, but significant challenges remain to be addressed such as AC losses management and rotating cryogenics implementation. Homopolar machines constitute the simplest electro-mechanical conversion systems possible, however the difficulty of establishing reliable and efficient low voltage, high DC current transfer from a stationary to a rotating system has prevented homopolar machines from competing with AC electrical machines. While sliding contacts or liquid metal contacts are feasible, they lead to high losses, high maintenance requirements and the use of environmentally unfriendly materials. We investigated field emission current transfer as an alternative to sliding contacts. We have demonstrated field emission current transfer in vacuum between a copper electrode and carbon nanotubes and diamond pyramids to evaluate the feasibility of contact-free current transfer for homopolar machines. The initial field emission testing was successfully demonstrated with current densities in the 10 mA/cm 2 range. The initial experiments validated the concept and supported the development of a roadmap for the development of contactless current transfer for homopolar machines, helped understand the limitations of the current test system and identify the key parameters that will lead to better performance.

99 GENERAL AND MISCELLANEOUS↗

Existing Methods for Grid Strength Assessment and Role of Hydropower in Future Grids

The power system is undergoing rapid evolution with increasing penetration of inverter-based resources (IBRs), large loads, microgrids, and power electronic devices. Ensuring reliable and stable operation of the modern power grid is a multi-faceted challenge that requires detailed understanding of this complex system. Dynamic stability is a major concern in maintaining the security of power grids as the generation mixes and large loads transitions to include high shares of power electronic devices. The operation of IBRs in regions with low system strength and higher grid impedances has been found to be the main reason behind many of the power system instabilities that manifest themselves in various types of oscillations and interactions that, if not properly addressed and damped, can jeopardize the reliable operation of the power system. Weak grid conditions compound such stability problems, particularly when many IBRs operate in proximity to and connect to weak power grids. Therefore, it is important to assess grid strength for planning, integration and operation of IBRs for a given power system. In this report, we aim to understand and classify existing methodologies for grid strength assessment, along with their limitations and future needs. Further, we aim to utilize the huge untapped potential in utilizing hydro energy resources in addressing some of the pertinent challenges of grid strength and reliable operation of modern power systems. Hydropower, historically valued for its flexibility and dispatchability, now faces new constraints due to reduced share of synchronous machines in the generation mix and seasonal variability of available water resources. Yet, these same plants present untapped potential beyond energy generation - notably, as providers of critical grid services. This report explores how hydropower plants, particularly through operation as synchronous condensers, can play a pivotal role in strengthening the grid amid evolving system dynamics.

13 HYDRO ENERGY↗

Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation

Modern power systems are increasingly vulnerable to frequency instability as inverter-based resources (IBRs) replace synchronous machines and reduce system rotational inertia. Existing small-signal frequency stability assessment methods are either computationally intensive, relying on simulation-driven approaches, or lack analytical stability regions that explicitly account for secondary frequency response (SFR). This paper introduces new analytical frameworks that enable evaluation small-signal frequency stability while explicitly incorporating tunable IBR and SFR parameters. Using Kharitonov’s theorem with an overbounding approach, explicit small-signal stability criteria are derived. In addition, based on Białas’ criterion and Hurwitz matrix, analytical stability regions are established to reveal feasible design spaces for SFR and IBR parameters tuning. Extensive Matlab/Simulink-based simulations validate the accuracy and computational efficiency of the proposed methods, demonstrating that coordinated tuning of SFR and IBR parameters can substantially enhance system resilience. By bridging analytical rigor with practical tunability, this work provides an analytical framework for assessing small-signal frequency stability in low-inertia grids, supporting the real-time, scalable, and resilient operation of sustainable power systems.

14 SOLAR ENERGY↗

Validation of Phasor-Domain Transmission and Distribution Co-simulation Against Electromagnetic Transient Simulation

The rapid deployment of renewable energy resources has led to the widespread use of power electronics in modern power systems. As these systems transition from being dominated by large synchronous machines to increasingly incorporating inverter-based resources (IBRs), traditional methods are becoming inadequate. Addressing this challenge, this paper introduces a scalable phasor-domain T\&D co-simulation framework based on open-source software. It focuses on the framework's validation against the PSCAD Electromagnetic Transient (EMT) analysis tool. The validation results demonstrate the framework's high-fidelity and a computational time speed-up of 60 to 100 times, marking a pioneering validation effort in T\&D co-simulation research.

Inverter-based resources, co-simulation, Electroma↗

Dynamic security assessment of systems powered only by grid-forming power plants with uncertain dispatch using polynomial vectors

A modern challenge in power engineering is to perform the dynamic security assessment (DSA) of grids that are 100% powered by inverter-based resources (IBRs). Addressing this challenge is difficult because: (i) the dispatch of IBRs can be uncertain as a result of the variability of renewable resources and (ii) they have hard current control limits that cannot be neglected, contrasting synchronous machines. To address this problem, this paper sets forth a framework to conduct DSA of bulk power systems that are 100% powered by grid-forming IBRs. Furthermore, the framework considers that IBR operational conditions are unknown but bounded by a zonotope which is also expressed as a polynomial vector for uncertainty propagation via Dormand–Prince integration. The framework is applied to modified versions of the WSCC 9-bus and IEEE 39-bus grids.

14 SOLAR ENERGY↗

Modeling and Automation Framework for High IBR Integration in Large-Scale Power Systems

The increasing prevalence of power electronics- interfaced renewable generation sources is leading to a gradual replacement of traditional thermal generation-based synchronous machines. In this context, the modeling of a large-scale power grid that incorporates a significant number of inverter-based resources is crucial for understanding the dynamics and effects of these resources on the power system. This study investigates the positive sequence model of grid-following and grid-forming inverters. Additionally, this work explores the integration of distributed energy resources using population as an indicator of their relative geographic locations. To address challenge to integrate these inverter based resources into a realistic grid of the US Western interconnection, automation scripts are developed to streamline the process of replacing conventional generators with grid-following and grid-forming inverters, as well as allocating distributed energy resources. Different penetration levels of these inverters are considered, and their frequency regulation support following a disturbance is compared through dynamic simulations.

Lyu, Xue↗

Dynamic Model of Back-to-Back Converter for System Level Phasor Simulation

The power system is expected to evolve rapidly with increasing deployment of power electronic interface and conditioning systems, microgrids, and hybrid AC/DC grids. Among power electronic systems, back-to-back (BTB) converters can be a powerful interface to integrate microgrids and networked microgrids. However, in system level dynamic simulations for synchronous machine dominated system with BTB converters, a detailed electromagnetic sinusoidal models is not warranted as these simulations are focused on electromechanical transients. This paper focus on developing a simple phasor model for back- to-back converters that can be easily integrated into powerflow solvers to facilitate large-scale power system simulations. The model is implemented using C++ language and integrated into GridLAB-D software as a potential new capability. The GridLAB-D phasor domain model is validated against the electromagnetic transient (EMT) simulation of the detailed switching model. Simulation results show that the phasor model successfully captures the dominant dynamics of the converters.

Mahmood, Hisham↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗

Probing Signal-Based Inertia and Frequency Response Estimation for Power Systems With High Levels of Inverter-Based Resources

Power system inertia is the inherent capability of a power system to resist changes in its frequency during disturbances. Real-time inertia estimation technology has become more important due to the low-inertia issues caused by the increasing integration levels of inverter-based resources (IBRs) from renewable energy; however, existing inertia estimation methods hardly consider multiple frequency response controls that act within the same time frame as conventional inertial response, thus making measured inertia values vary under different testing conditions. To resolve this issue, this paper proposes a novel real-time estimation method to simultaneously estimate a power system's inertia constant and frequency response droop constant using a well-designed probing signal. First, we formulate the inertia and frequency response model of a power system with IBRs. Second, through the integration and manipulation of the developed model, we propose a multivariate linear regression-based estimation method that is resilient to measurement noise. Third, we design a probing signal that can be injected by IBRs to incite the required transients for estimation. Finally, we validate the proposed estimation method through comprehensive power-hardware-in-the-loop experiments using inverter hardware and a realistic island power system model. The results demonstrate that the proposed method can accurately estimate the inertia and droop value of the power system with grid-following IBRs and grid-forming IBRs with virtual synchronous machine control.

frequency response↗

Postfault Operation of Three-Level Inverter Driven Six-Phase PMSM With Enhanced Torque–Speed Region

This article presents an open-switch postfault operational technique with enhanced torque–speed region for three-level (3L) active neutral point clamped (ANPC) inverter-driven symmetrical six-phase (SSP) permanent magnet synchronous machines (PMSMs). Maximum torque (MT), minimum loss (ML), and single three-phase (STP) operations are commonly used for the postfault operations of six-phase drives. The maximum possible torque and speed in these operations are generally limited by voltage, current ratings, and the neutral point configuration of the motor. To enhance the postfault torque and speed operating region, the torque and speed limits in different postfault operational techniques are determined based on the voltage, current constraints, and neutral point configuration of the SSP-PMSM. In this work, a unified postfault operation is proposed that increases the postfault operational limits by combining MT, ML, and STP operations and modifying the neutral point configuration of the SSP-PMSM. In addition, a technique is also presented that modifies the pulsewidth modulation technique to enable full torque operation below 0.5 p.u. speed. The proposed postfault operational technique enables full-speed (1 p.u.) operation by operating in STP mode and full torque operation (1 p.u.) below 0.5 p.u. speed. Furthermore, the postfault operational technique is experimentally validated using a Gallium Nitride (GaN) device-based3L-ANPC inverter-driven SSP-PMSM.

42 ENGINEERING↗