Search NASA⌕ Search

SEARCH · Search NASA

Results for “system (MEMS)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Position sensing circuit for an electrostatically driven MEMS device

The present disclosure relates to a system for detecting movement of a microelectromechanical system (MEMS) device. The system uses a drive voltage signal source for generating a low frequency drive voltage signal for driving the MEMS device. An excitation signal source may be used for generating an excitation signal which is also applied to the MEMS device. The excitation signal has a frequency which is above a physical response capability of the MEMS device, such that operation of the MEMS device is not significantly affected by the excitation signal. A sensing impedance is used to help generate a signal which is responsive to the capacitance of the MEMS device. The capacitance of the MEMS device changes in response to movement of the MEMS device. An output subsystem is provided which responds to changes sensed by the sensing impedance, and which produces an output voltage signal. A filter filters the output voltage signal to produce a filtered output voltage signal. The filtered output voltage signal is indicative of a position of the MEMS device.

Panas, Robert Matthew↗

MEMS-tunable optical ring resonator

A microelectromechanical systems (MEMS)-tunable optical ring resonator is described herein. The ring resonator includes a resonator ring and a tuner ring, along with one or more springs. The springs may be internal or external, i.e., either within or outside the areal footprint of the resonator ring and the tuner ring. The one or more springs are configured to displace the tuner ring from the resonator ring by a desired gap based upon a desired resonant wavelength of the resonator ring. Tuning is implemented by applying a voltage to the ring resonator, with motion of the tuner ring causing a corresponding change in the effective index of the resonator ring. As the ring resonator is essentially a capacitive device, it draws very little power once tuning is achieved.

Wood, Michael↗

Atomic-resolution lithography with an on-chip scanning tunneling microscope

In this work, atomic-resolution lithography with a Microelectromechanical-System (MEMS) based Scanning Tunneling Microscope (STM) is demonstrated for the first time. The microscope consists of a commercial UltraHigh-Vacuum (UHV) STM whose regular tip is replaced with a 1-Degree-of-Freedom (1-DOF) MEMS nanopositioner. This results in a hybrid STM system where XY-plane motions are provided by the piezotube of the original system and Z-axis motion by the MEMS with a higher bandwidth. Sharp tips made of Pt or W are added to the MEMS devices with postfabrication techniques. With this hybrid system, STM-based lithography is demonstrated on an H-passivated Si (100)-2×1 sample under UHV condition. Results prove the capability of the hybrid STM system for atomic-scale lithography. This capability, paired with the small footprint of the MEMS device, makes this approach a candidate for building a high-throughput parallel STM lithography platform by incorporating an array of 1-DOF MEMS devices that perform lithography in parallel.

Alipour, Afshin (ORCID:0000000263252067)↗

Atomic precision imaging with an on-chip scanning tunneling microscope integrated into a commercial ultrahigh vacuum STM system

In this article, we replace the Z axis of the piezotube of a conventional Ultrahigh-Vacuum (UHV) Scanning Tunneling Microscope (STM) with a one-degree-of-freedom Microelectromechanical-System (MEMS) nanopositioner. As a result, a hybrid system is realized in which motions in the XY plane are carried out by the piezotube, while the MEMS device performs the Z-axis positioning with a smaller footprint and higher sensitivity. With the proposed system and a feedback loop, STM imaging is conducted on an H-passivated Si (100)-2×1 sample in a UHV condition, demonstrating that this on-chip STM is conducive to atomic precision scanning tunneling microscopy.

Engineering↗

Fabrication of Freestanding Metallic Ni-Mo-W Microcantilever Beams With High Dimensional Stability

Recent studies have elucidated a promising balance of physical and mechanical properties of sputter deposited nickel-molybdenum-tungsten (Ni-Mo-W) films that have a unique nanotwinned microstructure and promising potential for use in high temperature microelectromechanical systems (MEMS). Here, the current study was undertaken to establish the feasibility of making nanotwinned Ni-Mo-W microcantilevers with standard micro- fabrication processing, to assess their dimensional stability, and to demonstrate the possibility of using nanotwinned Ni-Mo-W in metal MEMS devices. Deposition of Ni-Mo-W films in commercial sputtering chambers revealed a wide processing window for the formation of the requisite nanotwinned microstructure. Conventional photolithography and etchants were employed to shape blanket Ni-Mo-W films into freestanding microcantilever beams. Monitoring microcantilever deflections via interferometry provided a direct measure of residual stresses and overall dimensional stability. Heat treatments of 200° C and 400° C were used to mimic wafer bonding temperatures. At 400°C, microcantilevers exhibited modest stress relaxation, yielding beam deflection profiles on the nanometer scale and portending dimensional stability and control for future metal MEMS devices.

36 MATERIALS SCIENCE↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of multifunctional piezoelectric energy harvesting microgyroscopes with material degradation

Most microelectromechanical systems (MEMS) are made from brittle materials that are prone to cracking. Damage from the formation of cracks can occur anytime during the manufacturing process or due to mechanical loading of MEMS devices. Cracks can increase the structures flexibility and lead to changes in performance or total failure. Understanding the potential influences cracks in MEMS is necessary for the longevity of these systems. The energy harvesting microgyroscope studied in this work is susceptible to crack propagation in its silicon substrate and lead zirconate titanate piezoelectric patch. To this end, an electromechanical model is developed to capture the impacts of cracks on the performance of a damaged energy harvesting microgyroscope. Numerical methods are used to approximate the damage associated with distributed crack networks. Then, the static and dynamic responses of the damaged microgyroscope are analyzed for two possible multifunctional setups. Here, the current study revealed that cracks can significantly affect the static and dynamic behaviors of the microgyroscope energy harvester. Combinations of cracking and piezoelectric property degradation cause a decrease in the static pull-in voltage and shift the resonance frequencies of the system. Additionally, it is shown that the systems sensitivity to changes in the base rotation and energy harvesting capabilities vary widely depending on the severity of material degradation.

36 MATERIALS SCIENCE↗

Additive Manufacturing of Energy Harvesting Material System for Active Wireless MEMS Sensors

Combustion systems make up a large sum of the world’s yearly energy production despite advances in renewable energy sources. Precise control of pressure and temperature in combustion chambers allows for lower carbon emissions, and overall higher efficiency. Wireless temperature and pressure sensors are critical for the operation of combustion chambers. Energy harvesters have emerged as a viable way to power wireless sensors when heat and mechanical energy are available. Lithium niobate (LNB), barium titanate (BTO), and lead zirconate titanate (PZT) pyroelectric ceramics were studied and fabricated through additive manufacturing (AM) for use as energy harvesting structures in combustion environments. The electric power generation potential of LNB and PZT ceramics was studied by varying the temperature from 50 to 60 °C and by introducing cyclic compression loads of 2000 N amplitude. It was found that thermal energy conversion had the highest output of 500 nW and that combined thermal and mechanical conversion did not increase the harvesting potential because of the competing contributions of both effects. Powder bed and slurry extrusion AM methods were used to fabricate BTO and PZT ceramic structures. Optimization of the powder-based binder jetting method produced BTO ceramics with a relative density of 36.77% a piezoelectric coefficient of 153 pC/N. The density of the ceramics increased up to 56% when increasing the saturation of binder in the powder to because of liquid phase sintering. Finally, PZT structures were manufactured through AM and fin features were added to the design to enhance the heat transfer along the material. The harvested power density of the flat samples was 3.643 μW/cm 3 and of the finned samples was 3.034 μW/cm3. This research paves the ways for the development of self-powered wireless sensors in critical areas of operation such as combustion.

01 COAL, LIGNITE, AND PEAT↗

A MEMS Gyroscope for Reliable Long Duration Measurement While Drilling at 300°C

The 300°C Microelectromechanical system (MEMS) gyroscope project aims to contribute to DOE’s goal of increased geothermal drilling efficiency by 2025 through the development of a 300°C MEMS gyroscope for Measurement While Drilling (MWD). At the conclusion of the 2-year project, the team will develop a 300°C capable MEMS gyroscope containing GE’s patented Multi-Ring Gyroscope Transducer (MRGT) design, custom Silicon-On-Insulator (SOI) based frontend and feedback control electronics, and with demonstrated functionality and lifetime beyond 1000 hours. The project is divided into two budget periods with Go/No-Go decision at the end of the first budget period. The goal for the first budget period is to establish the feasibility of the MRGT and electronics design for meeting the 300°C performance requirements. The goal for the second budget period is to integrate the MRGT with the SOI-based application specific integrated circuit (ASIC) and demonstrate capability to operate at 300°C for 1000 hours. In Budget Period 1 we met the phase 1 goal. We successfully validated the combined MRG, electronics and packaging capability entitlement to achieving 0.5 degrees azimuth uncertainty while enabling operation at significantly higher temperatures than the state-of-the-art. In Budget Period 2, we successfully completed the integration of the MRGT and ASIC with associated high temperature, high reliability packaging to demonstrate the performance and functionality of the integrated gyroscope across the temperature range from room temperature to at 300°C. Furthermore, the team demonstrated operating life of >1,000 hours at 300°C, thus providing a validation of application-relevant lifetime capability.

15 GEOTHERMAL ENERGY↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

A novel quench detection method using microelectro- mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Application of Quaternions to Strap-Down MEMS Sensor Data

We describe the mathematical transformations required to convert the data recorded using typical 6-axis microelectromechanical systems (MEMS) sensor packages (3-axis rate gyroscopes and 3-axis accelerometers) when attached to an object undergoing a short duration loading event, such as blast loading, where inertial data alone are sufficient to track the object motion. By using the quaternion description, the complex object rotations and displacements that typically occur are translated into the more convenient earth frame of reference. An illustrative example is presented where a large and heavy object was thrown by the action of a very strong air blast in a complex manner. The data conversion process yielded an accurate animation of the object’s subsequent motion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

Here, a novel quench detection method using micro-electro-mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrothermal Micromirror Adaptive Illumination

As part of the Cyclotron Road program, Helux Lighting aimed to develop a highly adaptive illumination source based on microelectromechanical system (MEMS) technology and next-generation solid state lighting. Solid state lighting has caused a paradigm shift in the industry. Developing systems that put light only where it is needed can reduce energy consumption and have an impact on the well-being of the population by eliminating glare and wasted light. Full control could also reduce the disruption of sensitive ecosystems caused by light pollution. The most advanced fixtures available today are based on mechanical components that are bulky and expensive. The track light is the only inexpensive lighting system that permits redirection and, in some cases, spot size by motorized optical components. The most advanced light fixtures today are composed of a strategically arranged array of LEDs. More recent developments in the research community include dynamic liquid crystal lenses but fail to realize simultaneous dynamic steering and spot size. In this project, Helux worked on the capability development of their controllable micromirror combined with state-of-the-art solid state lighting to electronically adjusting light position, brightness, and illumination area.

42 ENGINEERING↗

Tailoring the coefficient of thermal expansion of ternary nickel alloys through compositional control and non-contact measurements

The majority of microelectromechanical systems (MEMS) are made of silicon, however, future applications will be used in extreme environments, especially at elevated temperatures, and require materials with enhanced properties. Use of metal alloys in these applications will require microscale manufacturability, a balance of physical and mechanical properties and dimensional stability. Here in this paper, we emphasized dimensional stability by reducing the coefficient of thermal expansion (CTE) and present an optical non-contact method for measuring the thermal expansion of planar thin films. A combinatorial approach was employed to determine the CTE of nickel-molybdenum-tungsten (Ni-Mo-W) sputter deposited films over a range of compositions, and the addition of Mo and W is shown to significantly decrease and provide a route for tailoring the CTE with compositional control. Ni-Mo-W alloys were revealed to have CTE values ranging from 8–12 × 10 -6 /°C, matching that of commercial glass substrates that are employed in numerous MEMS devices.

36 MATERIALS SCIENCE↗

Cryogenic optical beam steering for superconducting device calibration

We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope

Gas reactions studied by in situ electron microscopy can be used to capture the real-time morphological and microchemical transformations of materials at length scales down to the atomic level. In situ closed-cell gas reaction (CCGR) studies performed using (scanning) transmission electron microscopy (STEM) can separate and identify localized dynamic reactions, which are extremely challenging to capture using other characterization techniques. For these experiments, we used a CCGR holder that utilizes microelectromechanical systems (MEMS)-based heating microchips (hereafter referred to as "E-chips"). The experimental protocol described here details the method for performing in situ gas reactions in dry and wet gases in an aberration-corrected STEM. This method finds relevance in many different materials systems, such as catalysis and high-temperature oxidation of structural materials at atmospheric pressure and in the presence of various gases with or without water vapor. Here, several sample preparation methods are described for various material form factors. During the reaction, mass spectra obtained with a residual gas analyzer (RGA) system with and without water vapor further validates gas exposure conditions during reactions. Integrating an RGA with an in situ CCGR-STEM system can, therefore, provide critical insight to correlate gas composition with the dynamic surface evolution of materials during reactions. In situ/operando studies using this approach allow for detailed investigation of the fundamental reaction mechanisms and kinetics that occur at specific environmental conditions (time, temperature, gas, pressure), in real-time, and at high spatial resolution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗