Passive Peak Temperature Monitors Project Summary
The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.
The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.
A novel junction temperature monitoring sensor is proposed and experimentally demonstrated for application in MOS-gate power devices. The sensor is created using the polycide gate electrode layer of the devices to create a temperature-sensitive resistor without any additional fabrication steps. The resistor is located on the field oxide with one end grounded at the device reference terminal to isolate it from the device current and voltage transients. It allows in-situ monitoring of the device junction temperature during active circuit operation. The technology has been implemented to monitor the junction temperature of Silicon Carbide Junction Barrier Schottky Field Effect Transistors (SiC JBSFETs) with the bi-directional FET (BiDFET).
Distributed temperature monitoring can provide useful insights into the thermal conditions in the continuous caster tundish that can affect operating stability and cast quality, such as preheat conditions, superheat uniformity, fill height, and refractory wear. In the current study, fiber optic sensors were embedded into the refractory lining of a lab-scale tundish to record the temperature profiles during dry-out, preheating, and direct molten steel exposure to demonstrate sensor performance. Additional trials were performed with fiber optic sensors embedded in an industrial tundish used in production. Furthermore, the results demonstrate that fiber optic sensors using Rayleigh technology can provide accurate distributed temperature measurements in refractory lined vessels and provide useful information about the process.
The effect of irradiation on materials properties is an important field of study for materials usage in both fission and fusion systems for energy production. Neutron flux and energy spectrums are well understood; however, the irradiation temperature can be more difficult to determine. Since the early 1960s, Silicon Carbide (SiC) has been used as a passive post-irradiation temperature monitor because the irradiation defects anneal out above the irradiation temperature. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process. There are many properties that may be measured including electrical resistivity, bulk density, dimensions, thermal diffusivity, or lattice spacing. Electrical resistivity is accepted as a robust measurement technique; however, such method is time-consuming since the steps involved must be performed in a serial manner. The use of thermal expansion from continuous dilatometry is an automated process requiring minimal setup time. As part of a Nuclear Science User Facilities (NSUF) project, low dose silicon carbide monitors were irradiated in the BR2 material test reactor at SCK, Belgium, and were then evaluated at the Idaho National Laboratory (INL) High Temperature Test Laboratory (HTTL) to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation processes available at HTTL and the performance of the low dose silicon carbide temperature monitors.
While controlled environments are desirable for growing and measuring plants, growth chambers and greenhouses typically have microclimates that impact plant growth, development, and stress responses. Furthermore, opening and closing the doors of a controlled environment introduces variation in the environment, especially at temperature extremes, affecting both the measurements and the organisms within. Using multiple temperature data loggers to normalize results can be cost-prohibitive and rarely offers real-time feedback on temperature status. We used low-cost single-board computers, cameras, and temperature sensors to manage and capture growth chamber temperatures while acquiring plant image data. Detailed here are methods to document microclimates within a growth chamber so that data can be normalized to measured temperature information. This protocol describes a low-cost method for automated temperature monitoring, which enables both high-throughput measurements of temperature along with plant growth and stress responses via plant imaging.
Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.
Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.
Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at materials and test reactors. Melt wires or paint spots are often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires and paint spots as a post-irradiation technique for peak temperature indication. Unfortunately, these techniques are limited in that they can only detect whether a single temperature is or is not exceeded. Silicon carbide (SiC) monitors are advantageous because a single monitor can be used to determine the peak temperature reached within a relatively broad range (200 – 800°C). Although the use of SiC monitors was proposed more than five decades ago, the ultimate performance limits of this technique are not fully understood. The Nuclear Science User Facilities (NSUF) is the United States Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Its mission is to provide nuclear energy researchers access to world-class capabilities and to facilitate the advancement of nuclear science and technology. This mission is supported by providing access to state-of-the-art experimental irradiation testing, post irradiation examination facilities, and high performance computing capabilities as well as technical and scientific assistance for the design and execution of projects. As part of an NSUF project, low dose silicon carbide monitors were irradiated in the Belgian Reactor 2 and were then evaluated both at the SCK•CEN and at Idaho National Laboratory's High Temperature Test Laboratory to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation process, the irradiation test, and the performance of the low dose silicon carbide temperature monitors.
Gas-cooled nuclear reactors operate at temperatures up to 950 °C with significant spatial variations in power generation and coolant flow through hundreds of parallel flow channels, resulting in complex mixing at the core outlet. The high temperatures and complex mixing can damage downstream components, challenge reactor calorimetry for power determination, and result in significant conservatism in calculated peak fuel temperatures, which ultimately limits the total power output. Directly measuring each gas stream individually is unrealistic using single point thermocouples, requiring more robust sensing techniques. Fiber-optic sensors are resilient to high temperatures (up to 1,000 °C) and radiation damage. Moreover, distributed measurements can be made along the length of one fiber, making them potential candidates for monitoring local core outlet temperatures to improve core calorimetry and identify hot channels. Here, to the authors’ knowledge, this manuscript is the first to report spatially distributed fiber optic temperature measurements to quantify mixing at the outlet of a relevant orifice plate under prototypic temperature and flow regimes to assess the feasibility of using fiber-optic sensors for distributed measurements of coolant temperature in gas-cooled reactors. A single optical fiber captured dynamic changes in local temperatures, whereas the mixed outlet temperature exhibited a muted response and could not identify which channels were responsible for the change in the mixed outlet temperature. The discussion focuses on potential challenges for deploying distributed optical fibers in gas-cooled reactors, including the effects of vibrations, radiation-induced signal attenuation and drift, and routing of the fiber while minimizing flow obstructions.
We demonstrate a novel chalcogenide glass (ChG)-capped optical fiber temperature sensor capable of operating within harsh environment. The sensor architecture utilizes the heat-induced phase change (amorphous-to-crystalline) property of ChGs, which rapidly (80–100 ns) changes the optical properties of the material. The sensor response to temperature variation around the phase change of the ChG cap at the tip of the fiber provides abrupt changes in the reflected power intensity. This temperature is indicative of the temperature at the sensing node. We present the sensing performance of six different compositions of ChGs and a method to interpret the temperature profile between 440 °C and 600 °C in real-time using an array structure. The unique radiation-hardness property of ChGs makes the devices compatible with high-temperature and high-radiation environments, such as monitoring the cladding temperature of Light Water (LWR) or Sodium-cooled Fast (SFR) reactors.
Internal temperature is an important parameter for understanding the solid phase processing (SPP) of materials and improving feedback control of these processes. Friction stir processes, shear assisted processing and extrusion (ShAPE ™ ), and ultrahigh velocity (UHV) cold spray are examples of such processes. Simple thermal models based on temperatures measured at the boundary of the deforming body cannot capture the dynamic nature of temperature generation within the deforming solid. One possibly way of understanding internal temperature is by measuring sound speed, which varies as a function of temperature for materials and directing ultrasonic wave propagation through selected material volumes of interest. In this project, longitudinal wave speed is estimated for aluminum 6061. Piezoelectric materials bonded to a specimen provided data from which longitudinal wave speed was estimated. A discussion evaluated the linear relationship of wave speed versus temperature and postulated how wave speed measurements could be used to estimate the internal temperature of selected material volumes for feedback during SPP of materials. Instrumentation, data and analysis, and a discussion are reviewed.
Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.
This work explores peak estimation techniques in Brillouin Optical Time Domain Analysis (BOTDA), emphasizing both accuracy and efficiency. Euclidean distance measurement method is applied to principal components derived from Brillouin Gain Spectrum data. It offers a major speed advantage being 180 170 times faster than traditional curve fitting methods such as Lorentzian curve fitting, while maintaining similar accuracy. Additionally, a PCA- based neural network model shows significant reduction of peak estimation time compared to Lorentzian fitting. Results show Brillouin frequency shift errors lie under 0.75 MHz in both Euclidean distance-based and neural network-based methods, both of which utilize PCA components. For large data sets and long length fibers, PCA- assisted neural network for peak estimation would be an efficient solution.
The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.
In order to test and monitor the operational stability and conditions of various energy, and manufacturing systems and their components, development of accurate sensors capable of operating at temperatures in excess of 1000 °C in various environments for long durations is required. In addition, many of these harsh-environment systems do not permit sensors to be directly inserted, so these sensors need to be embedded into thermal protective materials. In this work were developed high-temperature embedded thermocouples composed of various doped lanthanum chromites-refractory based composites synthesized by a mixed-oxide route and directly embedded into a Al2O3 based refractory. The electrical properties were specifically manipulated by altering the level of percolation of the conductive phase within the refractory constituent. Chemical stability of sensors was determined by phase development analysis by X-ray diffraction and X-ray photoelectron spectroscopy; Seebeck coefficients were determined by thermoelectric voltages measurements at temperature up to 1400 oC.
This work presents a comparative analysis of the various signal processing techniques used in the Brillouin gain spectrum (BGS) peak estimation. Traditional fitting methods such as Lorentzian curve fitting (LCF) are slow and less effective in noisy data. PCA-based methods were tested on the experimental data: A Euclidian distance-based approach, and a probabilistic deep neural network (PDNN) based approach, both using 5 principal components to represent a single BGS. Both methods significantly reduce computational time with respect to LCF, whereas PDNN offers uncertainty insights along with the parameter value. Measuring a range of temperatures, analyzing accuracy, and speed, it can be concluded that PCA trained PDNN outperforms other methods, and appears to be helpful in scenario where large datasets are generated.