Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of fracture diagnostic methods for fluid distribution based on quantitative interpretation of distributed acoustic sensing and distributed temperature sensing

Multistage hydraulic fracturing design on horizontal wells has significantly evolved with larger fluid volume, more fracturing stages, and tighter perforation cluster spacing to efficiently stimulate unconventional reservoirs. From the published field observations, the recent fracturing design results in complex fracture networks or swarm of fractures. Fracture treatment evaluation is extremely challenging in such a case because of the large amount of variables in well completion and stimulation design. Combined measurements from different technologies can help in fracture diagnosis. Fluid distribution, either during fracture injection or during production, directly relates to the stimulation efficiency at the cluster level and at the stage level. Because it is unlikely in the real world to distribute the injected fluid uniformly among all the clusters, we need diagnostic techniques to generate the flow profile along a lateral. Fiber-optic measurements, such as distributed acoustic sensing (DAS) and distributed temperature sensing (DTS), are currently used to diagnose downhole flow conditions. This technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs. For optimizing a fracturing design, we also need to understand how the design parameters are correlated with the stimulation efficiency. In this study, we combine two sets of models of DAS and DTS data interpretation for injected fluid volume distribution. The DAS is interpreted based on an empirical correlation between fluid flow rates and frequency band energy from the acoustic signals. The DTS is interpreted by performing temperature history match-based thermal energy conservation. Because of the completely different physics behind the interpretations, the confirmation of two interpretations provides confidence in fluid distribution.

Geochemistry & Geophysics↗

Sensing Temperatures Via Prostheses And Manipulators

Proposed temperature-sensing system applies heat to (or removes heat from) human user's skin according to temperature of remote object. Used in artificial limbs and in telerobotic manipulators. In prosthetic arm and hand, sensors on tips of artificial fingers send signals to electronic control network that drives small, lightweight thermoelectric heat pump worn on back of user's shoulder. Heat pump heats or cools skin according to signals from sensors. Heat pump and control network worn like article of clothing. In manual control of remote robot, sensors placed in fingers of remote manipulator. Sensors drive, via similar electronic control network, thermoelectric heat pumps in fingers of glove worn by operator, who then has benefit of information about temperatures on manipulated object.

Zerkus, Mike↗

Environmental Barrier Coating Surface Temperature Mapping Using a Compatible Er-Doped Sc 2 SiO 5 Temperature-Sensing Layer

Accurate surface temperature-mapping capabilities in the 1300 to 1500 °C range are needed for SiC/SiC ceramic matrix composites protected by environmental barrier coatings (EBCs) under testing in turbine engine environment facilities. The strong background thermal radiation at these higher temperatures is a challenging issue. Er-doped Y 2 SiO 5 was previously shown to be capable of achieving luminescence lifetime-based temperature mapping up to 1560 °C as a standalone material. However, compatibility issues between an Er-doped Y 2 SiO 5 surface temperature sensing layer and an underlying Sc 2 Si 2 O 7 -based EBC topcoat limited temperature mapping of the EBC surface to a maximum of 1380 °C. Therefore, an Er-doped Sc 2 SiO 5 temperature sensing layer has been subsequently developed with better compatibility with the Sc2Si2O7-based EBC topcoat. Localized spot temperature measurements as well as luminescence lifetime imaging-based temperature mapping were demonstrated up to 1535 °C from a 15 µm thick Er-doped Sc 2 SiO 5 layer at the surface of a Sc2Si2O7-based EBC topcoat, a significant improvement over the Er-doped Y2SiO5 layer 1380 °C temperature sensing limit. No degradation of the Er-doped Sc 2 SiO 5 temperature sensing surface layer was observed.

temperature measurement↗

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan↗

Completion Effects on Diagnosing Multistage Facture Treatments with Distributed Temperature Sensing

Summary Distributed temperature sensing (DTS) is a valuable tool to diagnose multistage hydraulic fracture treatments. When a stage interval is shut in, the clusters that take more fluid during pumping warm up more slowly. Therefore, the fluid volume injected into each cluster can be quantitatively interpreted by numerical inversion of the warm-back temperature behavior. This general concept assumes that the different warm-back behavior is controlled by only the injected fluid volume; however, recent observations of DTS data indicate that completion configurations significantly influence the warm-back behavior. This paper investigates the completion effects on the DTS interpretation. In ideal conditions, when a stage is fractured, the upstream stage intervals should show an almost uniform temperature that is close to the injected fluid temperature. This is due to the high fluid velocity of injected fluid in the wellbore, and the upstream intervals have not been perforated (noncommunicating intervals), so the only heat transfer is heat conduction between the wellbore fluid and the surrounding reservoir. But the field DTS data show considerably irregular variations in temperature along the upstream stage intervals. These variations are caused by the completion effects. The nonuniform temperature profile is caused by different heat transfer behavior induced by completion hardware along the production casing string, such as joints, clamps, and blast protectors, and by the sensing cable location in the cement, as well as the cement quality. Because the varying heat transfer behavior impacts the warm-back behavior as well as the temperature profile, the completion effects need to be considered in DTS interpretation. A method of DTS interpretation considering the completion effects to diagnose multistage fracture treatments was developed. Because the heat transfer between a wellbore and a reservoir depends on the overall heat transfer coefficient describing heat conduction through the completion in a forward model, this parameter needs to be tuned all along the wellbore. To calibrate the completion effect, the temperature inversion is conducted using the temperature measured at a stage interval that is upstream of a stage interval currently being treated. Because the interpreted stage interval is not perforated at that time, the thermal behavior at the noncommunicating interval is governed by only the heat conduction through the completion environment. Once the effective values of the overall heat transfer coefficient are estimated along the interpreted stage interval, they can be assumed to be constant physical parameters. Then, the fluid volume distribution is interpreted by using the effective overall heat transfer coefficient profile along each interval. This study provides a field application of the developed interpretation method. The new interpretation method provides more accurate diagnosis of fracture treatments by DTS interpretation.

Engineering↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Characterizing soil water content variability across spatial scales from optimized high-resolution distributed temperature sensing technique

Fiber-optic Distributed Temperature Sensing, when combined with the Single-probe Heat-pulse technique can measure soil moisture (θ) across spatial scales. The key limitation of this system is in obtaining the relationship between soil thermal conductivity (λ) and θ for a specific field. Using the Department of Energy Atmospheric Radiation Measurement (ARM) site, this study tested a new methodology to account for the spatial variability in the λ-θ relationship using a Gaussian processes model. The resulting accurate θ measurements (RMSE = 0.03 m 3 m –3 ) were used to characterize the spatial variability of θ across scales and to develop an empirical equation that can correct for the changes in the θ spatial variability observed at different spatial resolutions. In addition, the number of required samples to accurately characterize θ and its variability over scales ranging from 5 m and 350 m were estimated. Finally, these findings provide key information to scale soil moisture from centimeters to hundreds of meters for process understanding.

54 ENVIRONMENTAL SCIENCES↗

Remote magneto-elastic analyte, viscosity and temperature sensing apparatus and associated methods of sensing

An analyte, viscosity, or temperature sensing apparatus for operative arrangement within a time-varying magnetic field, including a sensor with an outer surface that is chemically, frictionally, or thermally responsive and adhered to a base magnetostrictive element, and a receiver to measure a first and second value for magneto-elastic emission intensity of the sensor taken at, respectively, a first and second interrogation frequency. A change in mass or a change in material stiffness of the sensor due to the responsiveness, the viscosity and mass density of a fluid therearound, or the temperature, can be identified. The receiver, alternatively, measures a plurality of successive values for magneto-elastic emission intensity of the sensor taken over an operating range of successive interrogation frequencies to identify a value for the sensor's magneto-elastic resonant frequency (a fundamental frequency or harmonic thereof). Several sensors in an ordered array will provide a package of information.

Grimes, Craig A.↗

Utah FORGE: Well 16B(78)-32 Distributed Temperature Sensing Data from April and May 2024

This dataset includes Neubrex Energy Services fiber optic distributed temperature sensing (DTS) data from well 16B(78)-32 during stimulation and circulation, including interaction with well 16A(78)-32, during April and May 2024. The DTS data are stored in HDF5 file format and are accompanied by a PowerPoint report on the study. All times in this dataset are in UTC. Depths are in MD relative to Kelly Bushing Height, and temperatures are in degrees Fahrenheit. All DTS measurements were made using a Yokogawa 3000DTSX Distributed Temperature Sensing Interrogator Unit, with a spatial sampling interval of 3.28 feet and a temporal sampling rate of 129 seconds. The third-party Pressure-Temperature Gauge data should be used with caution after April 20, 2024, as its performance is not considered reliable beyond this date.

15 GEOTHERMAL ENERGY↗

Scan mirror remote temperature sensing system and method

A remote temperature sensing system (10) for a scanning mirror (7). The system (10) includes a sensor which detects heat radiated by the mirror and provides a signal in response thereto. In the illustrative implementation, the system (10) includes a thermistor mounted within a housing. The housing is contoured to maximize the receipt of thermal energy thereby. A mounting assembly maintains the thermistor a predetermined nonzero distance from the scanning mirror (7). The invention includes a shroud (12) mounted on the mirror (7) for shielding the thermistor and a support tube connected to the thermistor housing on a first end and to a base on the second end thereof. The support tube is adapted to remain stationary within the shroud as the scanning mirror and the shroud rotate due to the scanning of the mirror. Wires are connected to the thermistor on a first end thereof and are wrapped around the support tube. The wires include a length of electrically conductive material having a resistivity which has a low sensitivity to temperature variations. The sensor output is processed in a conventional manner to provide an output indicative of the temperature of the mirror.

VanDyk, Steven G.↗

The Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment

The Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment is described. The SILTS experiment will obtain high-spatial-resolution measurements of the temperatures of Shuttle orbiter leeside surfaces during atmospheric entry. The data will be obtained by means of an imaging, infrared radiometer, located atop the orbiter's vertical tail, which will view the orbiter fuselage and left wing. Implementation of the SILTS experiment required a significant change to the configuration of the orbiter's vertical tail fintip. The orbiter Columbia has been modified to carry the SILTS experiment which will be active on Columbia's next flight, currently scheduled for mid-1985.

Throckmorton, D. A.↗

The Thermal Response of a Packed Bed Thermal Energy Storage System upon Saturated Steam Injection Using Distributed Temperature Sensing

The effectiveness of a thermal energy storage (TES) system is typically characterized with the help of thermal stratification or temperature gradients along the direction of heat injection, which is typically the flow direction of heat transfer fluid. The steepness of temperature gradients are a direct indicator of the effectiveness or efficiency of the heat storage or dispatch process. The temperature gradient evolution along the packed bed of ceramic particles upon saturated steam injection is presented in this work. Distributed temperature sensing based on optical frequency domain reflectometry was deployed in a packed bed of ceramic particles to capture the thermal front evolution in the axial direction. The physical processes accompanying steam injection in packed beds are complex due to phase change, transitioning two-phase flow, and changes in condensate accumulation. Therefore, the variation of thermal response of the TES system for various steam injection flow rates was experimentally studied using a high-resolution distributed temperature sensing system in a chemically inert alumina particle-packed bed. Distinct zones of different heat transfer modes were observed during the steam injection experiments. A distinct conduction zone, evident from diffuse thermal fronts, was observed at low flow rates, and these thermal gradients became sharper as the flow rate increased. The diffuse thermal fronts in the heat storage media suggest a low exergy efficiency of the TES system, as energy losses started initiating before a significant fraction of the bed was saturated with steam.

25 ENERGY STORAGE↗