Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal losses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Computational Methodology for Simulating Thermal Loss Testing of the Advanced Stirling Convertor

Convertor and generator testing is carried out in tests designed to characterize convertor performance when subjected to environments intended to simulate launch and space conditions. The value of net heat input must be known in order to calculate convertor efficiency and to validate convertor performance. Specially designed test hardware was used to verify and validate a two step methodology for the prediction of net heat input. This lessons learned from these simulations have been applied to previous convertor simulations. As heat is supplied to the convertors, electric power is produced and measured. Net heat input to the convertor is one parameter that will contribute to the calculation of efficiency. This parameter is not measured directly. Insulation Loss. Determine the current status of the thermal conductivity of the micro-porous insulation. - Match heat source and hot end temperatures. - Match temperature difference across Kaowool insulation

Reid, Terry V.↗

Helium in the Martian atmosphere - Thermal loss considerations

Helium concentrations in the Martian atmosphere are estimated assuming that the helium production on Mars (comparable to its production on earth) via the radioactive decay of uranium and thorium is in steady state equilibrium with its thermal escape. Although nonthermal losses would tend to reduce the estimated concentrations, these concentrations are not necessarily an upper limit since higher production rates and/or a possibly lower effective exospheric temperature over the solar activity cycle could increase them to even higher values. The computed helium concentration at the Martian exobase (200 km) is 8 million atoms/cu cm. Through the lower exosphere, the computed helium concentrations are 30-200 times greater than the Mariner-measured atomic hydrogen concentrations. It follows that helium may be the predominant constituent in the Martian lower exosphere and may well control the orbital lifetime of Mars-orbiting spacecraft.

Levine, J. S.↗

Multi-stage pulse tube cryocooler with acoustic impedance constructed to reduce transient cool down time and thermal loss

The cool down time for a multi-stage, pulse tube cryocooler is reduced by configuring at least a portion of the acoustic impedance of a selected stage, higher than the first stage, so that it surrounds the cold head of the selected stage. The surrounding acoustic impedance of the selected stage is mounted in thermally conductive connection to the warm region of the selected stage for cooling the acoustic impedance and is fabricated of a high thermal diffusivity, low thermal radiation emissivity material, preferably aluminum.

Gedeon, David R.↗

A Computational Methodology for Simulating Thermal Loss Testing of the Advanced Stirling Convertor

The U.S. Department of Energy (DOE) and Lockheed Martin Space Systems Company (LMSSC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. This generator would use two highefficiency Advanced Stirling Convertors (ASCs), developed by Sunpower Inc. and NASA Glenn Research Center (GRC). The ASCs convert thermal energy from a radioisotope heat source into electricity. As part of ground testing of these ASCs, different operating conditions are used to simulate expected mission conditions. These conditions require achieving a particular operating frequency, hot end and cold end temperatures, and specified electrical power output for a given net heat input. In an effort to improve net heat input predictions, numerous tasks have been performed which provided a more accurate value for net heat input into the ASCs, including the use of multidimensional numerical models. Validation test hardware has also been used to provide a direct comparison of numerical results and validate the multi-dimensional numerical models used to predict convertor net heat input and efficiency. These validation tests were designed to simulate the temperature profile of an operating Stirling convertor and resulted in a measured net heat input of 244.4 W. The methodology was applied to the multi-dimensional numerical model which resulted in a net heat input of 240.3 W. The computational methodology resulted in a value of net heat input that was 1.7 percent less than that measured during laboratory testing. The resulting computational methodology and results are discussed.

Reid, Terry V.↗

Efficiency optimization of a thermionic converter array

Intensive study of the outer planets of the solar system requires the use of nuclear power for electric propulsion of spacecraft. Among the power conversion devices being considered for this application are thermionic converters. This paper presents the results of computer modeling of thermionic converters to identify the major design variables and select an optimum size for each of the thermionic converters for the power conversion system under consideration. Among the variables investigated were electrical and thermal losses in electrodes, leads and heat chokes. Those elements which minimized the electrical losses tended to increase thermal losses and system weight. Overall mechanical design and relative positioning of components also had impacts on converter efficiency and the power subsystem weight. Numerical calculations were made using the computer heat transfer code SINDA coupled with electrical loss parameters. The results of the computations are presented in this paper.

Kuo, Y. S.↗

Solar receivers and methods for capturing solar energy

Thermal receivers, systems, and methods are disclosed that efficiently capture concentrated solar energy into a plurality of heat absorption bodies for conversion into thermal energy. In an embodiment, the thermal receivers, systems, and methods enable simultaneous electricity conversion and thermal energy capture. The receiver design enables a high penetration of concentrated sunlight deep into the thermal receiver to increase light trapping and reduce thermal losses. The thermal receiver is integrated with a photovoltaic (PV) receiver platform that converts some of the incident light to electricity while passing the remaining light to the thermal receiver. In another embodiment, other thermal receivers, systems, and methods are disclosed that efficiently capture concentrated solar energy into a sheet of falling particles. In an embodiment, the thermal receivers, systems, and methods enable simultaneous electricity conversion and thermal energy capture.

Ho, Clifford K.↗

Performance Analyses of Supercritical Carbon Dioxide-Based Parabolic Trough Collectors with Double-Glazed Receivers

Supercritical carbon dioxide is becoming a hot research topic as a potential heat transfer fluid in parabolic trough concentrators since it enables operating the solar system at high temperatures for a higher quality of energy. However, the corresponding inflated thermal losses necessitate alternative receiver designs. This work examines four double-glazed receivers, with each annular space being evacuated or non-evacuated, in terms of the absorber tube's diameter (53-80 mm) and the diameter ratios of the two glass shells (1.2-2.0). An analytical model is developed and validated for this purpose, and the four designs are further examined using ground-level solar and meteorological measurements. The results demonstrate higher performance in the case of fully evacuating the receiver and using the smallest possible diameters of the three concentric cylinders, where the energy and exergy efficiencies reach 65.3 and 40.3%, respectively. Yet, evacuating only the inner annular space is sufficient to achieve virtually the same performance level. This energy efficiency decreases to 62% in case of increasing the tube diameter to 80 mm. As the operating temperature increases from 423 to 850 K, the specific thermal losses increase by 3.98-4.34 folds, depending on the receiver design. Double glazing the receivers is favorable only at high operating temperatures of sCO2, where the reduction in thermal losses overcomes the drop in optical efficiency. For an inlet sCO2 temperature of 850 K, thermal losses are reduced by 33.64 and 53.92%, compared to evacuated and non-evacuated single-glazed receivers, respectively. Throughout the year, the fully evacuated and fully non-evacuated double-glazed receivers have energy efficiencies of 54.96 and 52.39%, exergy efficiencies of 33.64 and 32.06%, and thermal losses of 348.8 and 402.5 W/m, respectively.

analytical model↗

Temperature-Staged Thermal Energy Storage Enabling Low Thermal Exergy Loss Reflux Boiling in Full Spectrum Solar Systems

Hybrid full spectrum solar systems (FSSS) designed to capture and convert the full solar wavelength spectrum use hybrid solar photovoltaic/thermodynamic cycles that require low thermal exergy loss systems capable of transferring high thermal energy rates and fluxes with very low temperature differentials and losses. One approach to achieving this capability are high-heat-flux reflux boiling systems that take advantage of high heat transfer boiling and condensation mechanisms. Advanced solar systems are also intermittent by their nature and their electrical generation is often out-of-phase with electric utility power demand, and their required power system cycling reduces efficiency, performance (dispatch ability), lifetime, and reliability. High temperature thermal energy storage (TES) at 300-600°C enables these reflux boiling systems to simultaneously store thermal energy internally to increase the energy dispatch ability of the associated solar system, as this can increase the power generation profile by several hours (up to 6-10 hours) per day. Many TES phase change materials (PCM’s) exist including KNO3, NaNO3, LiBr/KBr, MgCl2/NaCl/KCl, Zn/Mg, and CuCl/NaCl, which have various operating melting points and different latent heats of fusion. Common, cost effective TES PCM's are FeCl2/NaCl/KCl mixtures, whose phase change temperature can be varied and controlled by simple composition adjustments. This paper presents and discusses unique "temperature-staged" thermal energy storage configurations using these TES materials and analysis of such systems integrated into high-heat-flux reflux boiling systems. In this specific application, the TES materials are designed to operate at staged temperatures surrounding an operating design point near 350°C, while providing 18 kW of source heat transfer to operate a thermoacoustic power system during off-sun conditions (e.g., temporary cloud conditions, after sun-down). This work discusses relevant configurations, and critical thermal and entropy models of the TES configurations, which show the inherent minimization of thermal exergy during critical heat transfers within the configurations and systems envisioned.

Hendricks, Terry J.↗

Regeneration efficiency, shuttle heat loss and thermal conductivity in epoxy-composite annualr gap regenerators from 4K to 80K

A test apparatus designed to simulate a section of a Stirling cycle cryocooler was built. Measurements of regeneration efficiency, shuttle heat loss and thermal conductivity reported for several regenerator test sections. The test composites were epoxy glass, epoxy glass with lead particles, epoxy glass with activated charcoal and epoxy graphite. Losses measured for these materials were approximately the same. Losses are in good agreement with those calculated theoretically for an epoxy glass (C-10) composite. The implications of these results on cryocooler design are discussed.

Myrtle, K.↗

Collimation of high-speed flow with thermal spread losses

The operation of the neutral beam collimator designed for the mass spectrometer inlet system of the Space Shuttle Induced Environment Contamination Monitor system is discussed. The collimator will allow selective views of a 10 deg half-angle conical volume of space so that backscattered molecules from within this volume can be measured and related to the column densities of outgassing species. Gas molecules which enter the collimator but do not have a view from the entrance orifice to the exit are directed to a gas getter and eliminated. The loss of properly directed molecules in the collimator due to their thermal distribution is calculated for the case of a directed flow, which would occur when the collimator is pointed in the direction of motion of the spacecraft. Inlet to outlet flux ratios are also computed as a function of angle of attack.

Taeusch, D. R.↗

Temperature-Staged Thermal Energy Storage Enabling Low Thermal Exergy Loss Reflux Boiling in Full Spectrum Solar Energy Systems

The efficiency of solar power collection is increased by adding a thermal energy storage stage to a sunlight concentrator and thermodynamic power generator system. The thermal energy storage includes tubes or capsules made of a phase change material that stores thermal energy in different temperature stages through a working fluid. The stored thermal energy is directed to the thermodynamic generator during off-sun periods.

Hendricks, Terry↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal↗

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Dual Multilayer Insulation Blanket Concept to Radically Reduce Heat Loss From Thermally Controlled Spacecraft and Instruments

At large distances from the Sun (e.g. Jupiter/Saturn), the solar flux is less than 4% that at Earth. This requires very large solar arrays to meet the power demands of a typical new mission concept. Heat loss through Multi-Layer Insulation (MLI) blankets typically constitutes the vast majority of the total heat loss. Hence, improvements to MLI blankets that reduce heat loss are advantageous to the spacecraft design. The overall effective emittance (ε*) of MLI is usually a range dependent on the number of layers, size of blanket, seams, feedthroughs, layer density and operating temperatures of the heat source and heat sink. A concept has been developed at JPL to reduce the ε* by as much as a factor of two, which produces a corresponding reduction in heat losses. This concept utilizes two MLI blankets physically separated by traditional bumpers or spacers used for micrometeoroid protection. The outer surface of the inner blanket and the inner surface of the outer blanket are low emissivity surfaces to further minimize the total ε* of the overall dual MLI system. Analytical predictions of a dual MLI concept have been made using test data based ε* correlations. A development test has been conducted to validate the dual blanket design’s performance. This paper will describe the dual blanket design concept, schemes for its implementation, and the corresponding test results to validate its performance.

Duran, Mark↗

Efficiency of an AMTEC recirculating test cell, experiments and projections

The alkali metal thermal to electric converter (AMTEC) is an electrochemical device for the direct conversion of heat to electrical energy with efficiencies potentially near Carnot. The future usefulness of AMTEC for space power conversion depends on the efficiency of the devices. Systems studies have projected from 15 to 35 percent thermal to electric conversion efficiencies, and one experiment has demonstrated 19 percent efficiency for a short period of time. Recent experiments in a recirculating test cell (RTC) have demonstrated sustained conversion efficiencies as high as 10.2 percent early in cell life and 9.7 percent after maturity. Extensive thermal and electrochemical analysis of the cell during several experiments demonstrated that the efficiency could be improved in two ways. First, the electrode performance could be improved. The electrode for these tests operated at about one third the power density of state of the art electrodes. The low power density was caused by a combination of high series resistance and high mass flow resistance. Reducing these resistances could improve the efficiency to greater than 10 percent. Second, the cell thermal performance could be improved. Efficiencies greater than 14 percent could be realized through reducing the radiative thermal loss. Further improvements to the efficiency range predicted by systems studies can be accomplished through the development and use of an advanced condenser with improved reflectivity, close to that of a smooth sodium film, and the series connecting of individual cells to further reduce thermal losses.

Underwood, M. L.↗