Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal vacuum tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

GPHS-RTG F5R Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

Demonstration Test Report: Vacuum Thermal Desorption (VTD) Testing to Support West Area Waste Feed Test 2

Approximately 54 million gallons of radioactive and hazardous waste are stored in underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Waste Treatment and Immobilization Plant (WTP) is being constructed to immobilize the waste in glass waste forms. The baseline configuration of the WTP includes a Pretreatment Facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the non-radioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at a federal repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Thermionic Sources For Electron Cooling At IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project at the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling of 2.5 MeV protons in the presence of intense space-charge. Furthermore, we are constructing an electron source test stand at the University of Chicago which will validate the electrical, thermal, and vacuum characteristics of thermionic sources. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources for electron cooling and the test stand.

43 PARTICLE ACCELERATORS↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

Fatigue Test Result for High Burnup Pressurized Water Reactor Rods

The High Burnup Spent Fuel Data Project, sponsored by DOE-NE, is focused on understanding the effects of long-term storage and transportation on high burnup (HBU) (>45 gigawatt days per metric ton uranium) light water reactor fuel. The experiment includes 32 HBU spent nuclear fuel (SNF) assemblies that will be stored in a typical Independent Spent Fuel Storage Installation (ISFSI) and 25 sister rods - nine SNF rods that were removed from the fuel assemblies prior to insertion to the ISFSI and 16 SNF rods removed from similar HBU assemblies. The sister rods provide a baseline of the condition of the HBU rods prior to loading, drying, and long-term dry storage. Destructive examinations of the sister rods are focused on understanding overall SNF rod strength and durability. Both composite fuel and empty cladding will be tested to derive material properties. While the data generated can be used for multiple purposes, a primary goal of the sister rod PIE data and associated measured mechanical properties is to support existing fuel storage licensing and relicensing activities by addressing identified knowledge gaps, and enhance the technical basis for post-storage transportation, handling, and consolidation activities. Fatigue tests of HBU M5-clad, ZIRLO-clad, Zircaloy-4, and low tin Zircaloy-4 segments have been completed using ORNL’s Cyclic Integral Reversible Fatigue Tester (CIRFT). This is the first time ZIRLO-clad rods have been tested. Some of the segments were heat-treated to understand the effects of thermal transients such as those encountered during dry storage vacuum drying on the fatigue lifetime. This paper presents results of the fatigue tests obtained to date and discusses planned future tests.

Montgomery, Rose↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

Parametric Study of the Vacuum Permeator for the Tritium Extraction eXperiment

Tritium breeding is a critical component of any self-sustaining future fusion reactor. The liquid metal eutectic, PbLi, is of particular interest as a tritium breeder material due to its favorable thermophysical and neutronic properties. One of the several remaining challenges facing PbLi breeder blankets is the need to design and validate a highly efficient tritium extraction system. The vacuum permeator is a promising extraction concept that utilizes tritium permeation through a highly permeable metal membrane. The Tritium Extraction eXperiment (TEX) is a forced-convection PbLi loop constructed to investigate tritium extraction from PbLi with vacuum permeators. Accurate thermal-hydraulic and tritium transport models are required to establish appropriate test matrices, predict experiment outcomes, and analyze data. However, the hydrogen transport properties of PbLi and permeator materials have large uncertainties. A database is collected, and a parametric analysis is conducted on the effect of hydrogen transport material properties: diffusivity of H in PbLi and permeator, solubility of H in PbLi and permeator, and permeator surface recombination constant on the expected tritium extraction efficiency for a vacuum permeator installed in TEX. As a result, we observe solubility of H in PbLi and the permeator and the recombination constant of the permeator have the largest effect on the extraction efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Not even 6 dB: Gaussian quantum illumination in thermal background

Abstract In analyses of target detection with Gaussian state transmitters in a thermal background, the thermal occupation is taken to depend on the target reflectivity in a way which simplifies the analysis of the symmetric quantum hypothesis testing problem. However, this assumption precludes comparison of target detection performance between an arbitrary transmitter and a vacuum state transmitter, i.e. ‘detection without illumination’, which is relevant in a bright thermal background because a target can be detected by its optical shadow or some other perturbation of the background. Using a target-agnostic thermal environment leads to the result that the oft-claimed 6 dB possible reduction in the quantum Chernoff exponent for a two-mode squeezed vacuum transmitter over a coherent state transmitter in high-occupation thermal background is an unachievable limiting value, only occurring in a limit in which the target detection problem is ill-posed. Further analyzing quantum illumination in a target-agnostic thermal environment shows that a weak single-mode squeezed transmitter performs worse than ‘no illumination’, which is explained by the noise-increasing property of reflected low-intensity squeezed light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Test Article and Test Plan for Heat-Pipe Gap-Conductance Testing

The SPHERE Facility at INL is established to test phenomena related to heat pipes in nuclear applications. The current capability of the SPHERE testbed is operation of liquid alkali-metal-cooled heat pipes in a variety of atmospheres. The controlled atmosphere can be used to prevent oxidation of system parts and also to affect the thermal conductivity of gases for any interfacial gaps within the heat-pipe assembly. Currently available modes are vacuum, air, nitrogen, helium, and argon. Controlled mixtures of helium and argon are available to vary the thermal conductivity of the gas. The primary test article will be based on the existing 7-hole block design used for shakedown testing of the SPHERE Facility. The SPHERE test stand will be used with test articles to establish the conductivity between fuel elements as well as between the heat pipe and other layers of the fuel-rod assembly. Existing and new test blocks will be used and modified with additional instrumentation to establish the thermal conductivity between the gap of the block wall and the heat pipes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ELASTOMERIC MICROVASCULAR SELF-HEALING MATERIALS

Damaged elastomeric diaphragms within pneumatic controllers used in the oil and gas industry lead to an unintended release of methane. Self-healing microvascular materials capable of healing various types of damage have been fabricated. These microvascular materials are designed to replace currently available commercial diaphragms found in pneumatic controllers and provide a solution to reduce unintended methane leaks. Poly(dimethylsiloxane) (PDMS) was used as the main matrix material, with additional testing conducted on polyurethane and flexibilised epoxy materials. Microvascular networks were implemented into the elastomeric membranes to act as ves- sels to deliver healing agents to the damaged areas. The complex, interdigitated channel networks were created using a 3D printed custom compounded filament composed of polylactic acid (PLA) and tin(II) oxalate. Two-part liquid casting polymers were poured around the channels into a mould to create samples with the scaffolding of the microvascular channels intact. Hollow microvascular networks were created by placing the samples within a vacuum oven at 250◦C which causes the thermal depolymerisation of PLA into its gaseous monomers. The manufactured materials were placed in test stands and pressurized using nitrogen gas to determine their healing and mechanical behaviour. Self-healing behaviour was demonstrated using PDMS matrix materials and healing chemistries within a pressure test cell. This test cell was designed to detect any damage to a sample by record- ing an outlet pressure. Damages including puncture holes, diagonal cuts and star-shaped central iv cuts were applied to the samples and a reduction in the outlet pressure was recorded for all sam- ples. A variation in channel spacing and diameter was studied to determine the optimal design of the microvascular network for self-healing performance. The mechanical performance of elastomeric membrane materials within a diaphragmatic pressurised stand was observed. Deformations and strains around the channels and channel inter- sections at the midplane of the materials were recorded using digital image correlation. Normal stresses were calculated using Hooke’s law and the material properties of the PDMS matrix. A reduction in leak rate, implying the success of self-healing, was recorded within manu- factured diaphragm samples tested within a commercial valve. PDMS is the favourable material when compared to polyurethane and flexibilised epoxy for creating

03 NATURAL GAS↗

Condition assessment of cable insulation materials in advanced reactor environments

While existing cable insulation materials are sufficient for use in the current reactor fleet, environmental conditions inside some advanced reactors, such as small modular reactors, will be substantially harsher. The work herein was conducted to assess the performance and overall survivability of several high-temperature, radiation resistant insulation polymers in a simulated small modular reactor environment. The materials evaluated under this research include polyether ether ketone, polyimide, and silicone rubber. These polymers were subjected to 1000 h of environmental stress exposure under two different conditions: 1) high temperature (i.e., 250 °C) in atmospheric pressure and 2) high temperature in a low-pressure vacuum (i.e., less than 2 psia). During the environmental exposure process, each insulation was periodically tested using several materials characterization techniques including Fourier transform infrared spectroscopy, oxidation induction time, and oxidation induction temperature. The objective of this testing was to assess and monitor changes that occurred in the thermal and chemical properties of the materials during the environmental exposures. The overall survivability of each insulation was assessed based on these property changes. The results of this research revealed that the polyimide and polyether ether ketone insulations had significantly better thermal and chemical stability than the silicone rubber during both the high-temperature atmospheric and vacuum exposures. Both polyimide and polyether ether ketone experienced minimal reductions in their chemical and thermal properties over the course of 1000 h in the simulated environments. Finally, based on this research, polyimide and polyether ether ketone show promise as potential base materials for small modular reactor cable insulation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Stability Testing of LANA.75

Savannah River Site has used the metal hydride LaNi 4.25 Al 0.75 (LANA.75) in the Tritium Facilities for over two decades. LANA.75 beds store significant quantities of tritium but have a limited service life due to the radiolytic decay of tritium to 3He within the metal matrix. It has been shown that the isotherm performance of a tritium-aged LANA.75 sample can be restored by heating under vacuum. Additional investigation is needed to ensure there are no unexpected changes to the hydride before this technique is employed in full-scale beds in the Tritium Facilities. In addition, it is necessary to verify the regenerable behavior and thermal stability of LANA.75 on a small scale prior to it being implemented on a large scale. In this work, a non-tritiated bench-scale LANA.75 sample was held at 750°C under vacuum for 200 h to simulate exposure to multiple restoration evolutions. Hydride isotherm performance, chemical composition, crystallinity, and morphology are compared between the pre-restorative and post-restorative testing samples. No significant changes were observed in composition or crystallinity. Comparison of pre-anneal and post-anneal isotherms showed that performance improved rather than deteriorated during the evolution. Scanning electron microscopy analysis showed small growths on the particle surface after exposure to regeneration conditions. Additional testing will be required to determine the cause of these growths.

08 HYDROGEN↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Drying Cycle Simulator Thermal Response to Commercial Drying Conditions

The purpose of this report is to document updates on testing of the apparatus built to simulate commercial drying procedures for spent nuclear fuel at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention that incorporate relevant physics and well-controlled boundary conditions. This report documents testing updates for the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes preliminary testing of the ADCS through measurement and analysis of the thermal response of the system to a subset of commercial drying conditions that exclude the introduction of water, namely simulated decay heats and pressures relevant to commercial drying. This test series, referred to as a “dry” test series in this report, spans three uniform waterproof heater rod powers (representing spent fuel decay heats), four helium fill pressures, and six vacuum levels. This test series was conducted to cover the range of expected ADCS testing conditions for upcoming “wet” testing, where water will be introduced and a simulated commercial drying cycle will be performed. The dry test conditions were derived from the commercial drying conditions seen in the High Burnup Demonstration and the vacuum drying conditions chosen for a smaller scale Dashpot Drying Apparatus tested at Sandia National Laboratories in FY22. For a given uniform power and pressure/vacuum level, the ADCS was operated at constant power and pressure and allowed to reach steady state conditions. The thermal data obtained from these tests were analyzed, and the results can inform computational models built to simulate commercial drying processes by providing baseline thermal data prior to the introduction of water. Following the preliminary dry tests, a test plan for the ADCS will be developed to implement a drying procedure that begins with the introduction of water to the system and is based on measurements from the drying process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites. The data from these investigations is expected to inform the efficacy of commercial drying operations through the quantification of residual water in a prototypic-length dry storage canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗