Ray-tracing image simulations of transparent objects with complex shape and inhomogeneous refractive index

Optical images of transparent three-dimensional objects can be different from a replica of the object’s cross section in the image plane, due to refraction at the surface or in the body of the object. Simulations of the object’s image are thus needed for the visualization and validation of physical models. We report ray tracing image simulations that achieved high physical fidelity, reproducing optical behaviors and image features not rendered in previous studies. We replicated brightfield microscopy images of drops with complex shapes, and images of pressure and shock waves traveling inside them. For high physical fidelity, the simulations must replicate the spatial and angular distribution of illumination rays, and both the experiment and the simulation must be designed for accurate optical modeling. The simulations are highly sensitive to the properties of the drops and can be used to diagnose and refine fluid dynamics models. The simulated images can also be optimized to extract multiple 3D properties from experimental images. Compared to specialized single-shot 3D imaging methods, this approach has the advantage that it preserves the experimental simplicity, the high resolution, and the visual interpretability characteristic to basic optical imaging. The techniques introduced here are directly applicable to optical microscopy, so they can be used in other fields, such as microfluidics and biology, to expand the type and the accuracy of three-dimensional information that can be extracted from basic optical images.

Cavitation↗

Chiral, Topological, and Knotted Colloids in Liquid Crystals

The geometric shape, symmetry, and topology of colloidal particles often allow for controlling colloidal phase behavior and physical properties of these soft matter systems. In liquid crystalline dispersions, colloidal particles with low symmetry and nontrivial topology of surface confinement are of particular interest, including surfaces shaped as handlebodies, spirals, knots, multi-component links, and so on. These types of colloidal surfaces induce topologically nontrivial three-dimensional director field configurations and topological defects. Director switching by electric fields, laser tweezing of defects, and local photo-thermal melting of the liquid crystal host medium promote transformations among many stable and metastable particle-induced director configurations that can be revealed by means of direct label-free three-dimensional nonlinear optical imaging. The interplay between topologies of colloidal surfaces, director fields, and defects is found to show a number of unexpected features, such as knotting and linking of line defects, often uniquely arising from the nonpolar nature of the nematic director field. This review article highlights fascinating examples of new physical behavior arising from the interplay of nematic molecular order and both chiral symmetry and topology of colloidal inclusions within the nematic host. Furthermore, the article concludes with a brief discussion of how these findings may lay the groundwork for new types of topology-dictated self-assembly in soft condensed matter leading to novel mesostructured composite materials, as well as for experimental insights into the pure-math aspects of low-dimensional topology.

chirality↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Three-dimensional photoluminescence imaging of threading dislocations in GaN by sub-band optical excitation

GaN is rapidly gaining attention for implementation in power electronics but is still impacted by its high density of threading dislocations (TDs), which have been shown to facilitate current leakage through devices limiting their performance and reliability. Here, we discuss a novel implementation of photoluminescence (PL) imaging to study TDs in regions within vertically structured p-i-n GaN (PIN) diodes consisting of metalorganic chemical vapor deposition (MOCVD) epitaxial layers grown on ammonothermal GaN (am-GaN) substrates. PL imaging with a sub-bandgap excitation energy (3.1 eV) reveals TDs with excellent clarity in three dimensions within the am-GaN substrate. Galvanometric-driven PL imaging allows the microstructure of hundreds of devices to be characterized in a single session, enhancing the screening process through the addition of device specific TD location tracking and density mapping. The visibility, structural characteristics, luminescent nature and evolution of TDs through the GaN growth process are described, potentially providing the ability to define TD structures associated with leakage current.

36 MATERIALS SCIENCE↗

Influence of gradation on failure mode of saturated sand at particle scale

Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.

Elnur, Mohammed [University of Tennessee]↗

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗

Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography

We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.

36 MATERIALS SCIENCE↗

Revealing the three-dimensional structure of microbunched plasma-wakefield-accelerated electron beams

Abstract Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and X-ray diagnostics have established that their charge concentrates within a micrometre-sized volume, but its sub-micrometre internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation that a laser-wakefield-accelerated electron bunch generates when exiting a metal foil, we reveal the structure of the coherently radiating component of bunch charge. The key features of the images are shown to uniquely correlate with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionizing high- Z gas-target dopants or by uncontrolled laser–plasma dynamics. With additional input from the electron spectra, spatially averaged coherent optical transition radiation spectra and particle-in-cell simulations, we reconstruct coherent three-dimensional charge structures. The results demonstrate an essential metrology for next-generation compact X-ray free-electron lasers driven by plasma-based accelerators.

43 PARTICLE ACCELERATORS↗

3D nanolithography with metalens arrays and spatially adaptive illumination

The growing demand for advanced materials, miniaturized devices and integrated microsystems calls for the reliable fabrication of complex, multiscale, three-dimensional (3D) architectures, a need increasingly addressed through light-based and laser-based processes. However, owing to the field-of-view (FOV) limitations of conventional imaging optics, existing 3D laser nanofabrication techniques face fundamental challenges in throughput, proximity error and stitching defects on the path to scaling. Here, in this study, we present a scalable 3D nanofabrication platform that uses a metalens-generated focal spot array to parallelize two-photon lithography (TPL) beyond centimetre-scale write field areas. Metalenses are ideally suited for producing submicron-scale focal spots for high-throughput nanolithography, as they uniquely feature large numerical apertures (NAs), immersion media compatibility and large-scale manufacturability. We experimentally demonstrate a printing system that uses a 12-cm 2 metalens array to produce more than 120,000 cooperative focal spots, corresponding to a throughput exceeding 10 8 voxels s −1 . By programmatically patterning the focal spot array using a spatial light modulator (SLM), an adaptive parallel printing strategy is developed for precise greyscale linewidth modulation and choreographed printing of semiperiodic and fully aperiodic 3D geometries. We demonstrate parallel printing of replicated microstructures (>50 M microparticles per day), centimetre-scale 3D architectures with feature sizes down to 113 nm, and photonic and mechanical metamaterials. This work demonstrates the potential of 3D nanolithography towards wafer-scale production, showing how TPL could be used at scale for applications in microelectronics, biomedicine, quantum technology and high-energy laser targets.

Materials science↗

Helical Photonic Metamaterials for Encrypted Chiral Holograms

Helical structures are among the most quintessential three-dimensional (3D) forms that exhibit mirror asymmetry, a hallmark of chirality. Various structural parameters of helices directly linked to chiroptical properties highlight their importance as essential optical metamaterials for polarization-resolved sensors, imaging, and spectroscopies. However, such function-defining properties remain incompletely understood due to fabrication challenges and the lack of a relationship between structure and optical properties. Here, helical structures are analyzed parametrically, and correlations are established that are applicable to the design of chiral helical optical metamaterials. By systematically varying independent parameters—such as from single-turn to five-turn helices and from small major radii to larger ones optimized to fit the unit cell—the underlying relationships with ellipticty are revealed. In addition to theoretical modeling, the findings are experimentally validated using 3D printing and terahertz spectroscopy. The results demonstrate that optimized helical structures are mechanically tunable and exhibit unprecedented optical properties, including broadband and high-magnitude ellipticity spectra. Being embedded in soft elastomers, helical arrays can serve as soft, stretchable optical-mechanical sensors and holograms containing encoded information, such as barcodes and quick response (QR) codes. Chiral QR codes are realized using pixelated single helices with different handedness, demonstrating their potential as advanced encryption/decryption systems for security applications and chiral metaholograms.

Encrypted QR codes↗

Dynamic molecular architecture of the synaptonemal complex

During meiosis, pairing between homologous chromosomes is stabilized by the assembly of the synaptonemal complex (SC). The SC ensures the formation of crossovers between homologous chromosomes and regulates their distribution. However, how the SC regulates crossover formation remains elusive. We isolated an unusual mutation in Caenorhabditis elegans that disrupts crossover interference but not SC assembly. This mutation alters the unique C terminal domain of an essential SC protein, SYP-4, a likely ortholog of the vertebrate SC protein SIX6OS1. We use three-dimensional stochastic optical reconstruction microscopy (3D-STORM) to interrogate the molecular architecture of the SC from wild-type and mutant C. elegans animals. Using a probabilistic mapping approach to analyze super-resolution image data, we detect changes in the organization of the synaptonemal complex in wild-type animals that coincide with crossover designation. We also found that our syp-4 mutant perturbs SC architecture. Our findings add to growing evidence that the SC is an active material whose molecular organization contributes to chromosome-wide crossover regulation.

59 BASIC BIOLOGICAL SCIENCES↗

STORM Super-Resolution Visualization of Self-Assembled γPFD Chaperone Ultrastructures in Methanocaldococcus jannaschii

Gamma-prefoldin (γPFD), a unique chaperone found in the extremely thermophilic methanogen Methanocaldococcus jannaschii, self-assembles into filaments in vitro, which so far have been observed using transmission electron microscopy and cryo-electron microscopy. Utilizing three-dimensional stochastic optical reconstruction microscopy (3D-STORM), here we achieve ~20 nm resolution by precisely locating individual fluorescent molecules, hence resolving γPFD ultrastructure both in vitro and in vivo. Through CF647 NHS ester labeling, we first demonstrate the accurate visualization of filaments and bundles with purified γPFD. Next, by implementing immunofluorescence labeling after creating a 3xFLAG-tagged γPFD strain, we successfully visualize γPFD in M. jannaschii cells. Through 3D-STORM and two-color STORM imaging with DNA, we show the widespread distribution of filamentous γPFD structures within the cell. These findings provide valuable insights into the structure and localization of γPFD, opening up possibilities for studying intriguing nanoscale components not only in archaea but also in other microorganisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-dimensional reconstruction of THz near-fields from a LiNbO3 optical rectification source

Terahertz (THz) generation by optical rectification in LiNbO3 (LN) is a widely used technique for generating intense THz radiation. The spatiotemporal characterization of THz pulses from these sources is currently limited to far-field methods. While simulations of tilted pulse front THz generation have been published, little work has been done to measure the near-field properties of the THz source. A better understanding of the THz near-field properties will improve optimization of THz generation efficiency, transport, and coupling. We demonstrate a technique for quantitative spatiotemporal characterization of single-cycle strong-field THz pulses with 2-D near-field electro-optic imaging. We have reconstructed the full temporal 3D THz near-field and shown how the phase front can be tailored by controlling the incident pump pulse.

Gabriel, Annika↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.