At least 19 records

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

TiltEM User Manual

The ability to automate the scanning transmission electron microscope (S/TEM) is tantamount to addressing next generation artificial intelligence, machine learning, and materials modeling capabilities. Constant utilization of these high-end capital equipment purchases also serves the requirements of the Department of Energy (DOE) to be fiscally responsible to the public. The development of an automated multi-modal tilt series algorithm for dark field/bright field S/TEM imaging plus chemical identification with energy dispersive x-ray spectroscopy has been achieved at PNNL. A tilt series workflow has now been generated which allows for autonomous collection of imaging and compositional information simultaneously. This advancement is due in large part to a transition from the rigid and microscope specific JEOL hardware environment, to the more adaptable GMS environment. This has thereby led to a greater degree of flexibility in the application of this method across platforms in addition to substantial time savings to the user.

47 OTHER INSTRUMENTATION↗

Solving complex nanostructures with ptychographic atomic electron tomography

Abstract Transmission electron microscopy (TEM) is essential for determining atomic scale structures in structural biology and materials science. In structural biology, three-dimensional structures of proteins are routinely determined from thousands of identical particles using phase-contrast TEM. In materials science, three-dimensional atomic structures of complex nanomaterials have been determined using atomic electron tomography (AET). However, neither of these methods can determine the three-dimensional atomic structure of heterogeneous nanomaterials containing light elements. Here, we perform ptychographic electron tomography from 34.5 million diffraction patterns to reconstruct an atomic resolution tilt series of a double wall-carbon nanotube (DW-CNT) encapsulating a complex ZrTe sandwich structure. Class averaging the resulting tilt series images and subpixel localization of the atomic peaks reveals a Zr 11 Te 50 structure containing a previously unobserved ZrTe 2 phase in the core. The experimental realization of atomic resolution ptychographic electron tomography will allow for the structural determination of a wide range of beam-sensitive nanomaterials containing light elements.

36 MATERIALS SCIENCE↗

Machining-inducted residual strain and ductile-brittle transition in sapphire revealed by X-ray nanoprobe diffraction microscopy

Hard X-ray nanoprobe diffraction microscopy is employed to investigate machining-induced residual lattice strain in single-crystal sapphire following ultra-precision orthogonal plunge cutting. In this study, tilt-series and single-angle acquisition strategies are systematically compared to evaluate their capability for resolving lattice variations associated with the machining process. An analytical framework is developed to enable the efficient and reliable extraction of strains, which serve as strain-based indicators of changes in the dominant deformation mechanism. The measured high-dimensional strain exhibits spatial heterogeneity and systematic evolution along the cutting path, consistent with deformation-regime changes from ductile response to crack-prone behavior.

Liang, Rui↗

Correlative montage parallel array cryo-tomography for in situ structural cell biology

Abstract Imaging large fields of view while preserving high-resolution structural information remains a challenge in low-dose cryo-electron tomography. Here we present robust tools for montage parallel array cryo-tomography (MPACT) tailored for vitrified specimens. The combination of correlative cryo-fluorescence microscopy, focused-ion-beam milling, substrate micropatterning, and MPACT supports studies that contextually define the three-dimensional architecture of cells. To further extend the flexibility of MPACT, tilt series may be processed in their entirety or as individual tiles suitable for sub-tomogram averaging, enabling efficient data processing and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Deep learning of structural morphology imaged by scanning X-ray diffraction microscopy

Scanning X-ray nanodiffraction microscopy is a powerful technique for spatially resolving nanoscale structural morphologies by diffraction contrast. One of the critical challenges in experimental nanodiffraction data analysis is posed by the convergence angle of nanoscale focusing optics which creates simultaneous dependency of the far-field scattering data on three independent components of the local strain tensor-corresponding to dilation and two potential rigid body rotations of the unit cell. All three components are in principle resolvable through a spatially mapped sample tilt series; however, traditional data analysis is computationally expensive and prone to artifacts. In this study, we implement NanobeamNN, a convolutional neural network specifically tailored to the analysis of scanning probe X-ray microscopy data. NanobeamNN learns lattice strain and rotation angles from simulated diffraction of a focused X-ray nanobeam by an epitaxial thin film and can directly make reasonable predictions on experimental data without the need for additional fine-tuning. We demonstrate that this approach represents a significant advancement in computational speed over conventional methods, as well as a potential improvement in accuracy over the current standard.

Luo, Aileen [Cornell Univ., Ithaca, NY (United Sta↗

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE↗

In-situ heating-and-electron tomography for materials research: from 3D ( In-situ 2D) to 4D ( In-situ 3D)

In-situ observation has expanded the application of transmission electron microscopy (TEM) and has made a significant contribution to materials research and development for energy, biomedical, quantum, etc. Recent technological developments related to in-situ TEM have empowered the incorporation of three-dimensional observation, which was previously considered incompatible. In this review article, we take up heating as the most commonly used external stimulus for in-situ TEM observation and overview recent in-situ TEM studies. Then, we focus on the electron tomography (ET) and in-situ heating combined observation by introducing the authors’ recent research as an example. Assuming that in-situ heating observation is expanded from two dimensions to three dimensions using a conventional TEM apparatus and a commercially available in-situ heating specimen holder, the following in-situ heating-and-ET observation procedure is proposed: (i) use a rapid heating-and-cooling function of a micro-electro-mechanical system holder; (ii) heat and cool the specimen intermittently and (iii) acquire a tilt-series dataset when the specimen heating is stopped. This procedure is not too technically challenging and can have a wide range of applications. Essential technical points for a successful 4D (space and time) observation will be discussed through reviewing the authors’ example application.

36 MATERIALS SCIENCE↗

Towards Autonomous Experiments by Connecting High Performance Microscopy with High Performance Computing

The digitization of controls, data, and analysis in microscopy is bringing the idea of autonomous microscopes closer to reality than ever before. Automated transmission electron microscopy (TEM) is already fairly routine for some experiments the only require simple repetitive tasks such as imaging biological macromolecules for single particle cryoEM [1], tilt series for electron tomography [2], and movies for crystallography [3]. The vast majority of TEM experiments are conducted completely by human operators who choose the regions of interest, optimize experimental parameters, and make decisions about data quality visually during an experiment. The field is still a long way from having completely autonomous TEMs that can adapt to sample difficulties and tune experimental parameters based on data quality and desired experimental outcomes. Part of the issue is the lack of capability for feeding information learned from on-line, live data analysis back into the on-going experiment [4]. Furthermore, this presentation will discuss current capabilities for large scale data reduction and analysis using high performance computing (i.e. supercomputing) and progress towards developing a true feed-back loop that places data analysis and theory in the experimental loop.

97 MATHEMATICS AND COMPUTING↗

Multislice Electron Tomography Using Four-Dimensional Scanning Transmission Electron Microscopy

Electron tomography offers useful three-dimensional (3D) structural information, which cannot be observed by two-dimensional imaging. By combining annular dark-field scanning transmission electron microscopy (ADF STEM) with aberration correction, the resolution of electron tomography has reached atomic resolution. However, tomography based on ADF STEM inherently suffers from several issues, including a high electron-dose requirement, poor contrast for light elements, and artifacts from image-contrast nonlinearity. Here, we develop an alternative method called multislice electron tomography (MSET) based on four-dimensional STEM tilt series. In this study, our simulations show that multislice-based 3D reconstruction can effectively reduce undesirable reconstruction artifacts from the nonlinear contrast, allowing precise determination of atomic structures with improved sensitivity for low-Z elements, at considerably low electron-dose conditions. We expect that the MSET method can be applied to a wide variety of materials, including radiation-sensitive samples and materials containing light elements whose 3D atomic structures have never been fully elucidated due to electron-dose limitations or nonlinear imaging contrast.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Reproducible Validation of Algorithms for Estimating Array Tilt and Azimuth from Photovoltaic Power Time Series

In this research, we assess the viability of four different, publicly available algorithms for estimating the azimuth and tilt parameters of solar photovoltaic systems using only the associated AC power time series data and site latitude-longitude coordinates. In this work, we curated a benchmarking data set of 44 fixed-tilt systems, comprising 275 measured AC power inverter data streams, with known azimuth and tilt parameters. Additionally, we isolated test cases in the data set with real- world issues, including shading and clipping, to determine how algorithm performance varies based on the presence of these phenomena. Using this data set for benchmarking, we evaluated the estimated vs. actual system characteristics for each algorithm, as well as the associated algorithm execution time using a standardized benchmarking process. The two highest performing algorithms were the Solar Data Tools and the PVWatts 5- based methods, which both achieved a median absolute error of approximately 5 and 1 degrees for azimuth and tilt, respectively. During run time analysis, the SDT method was approximately 5 times faster than the PVWatts 5-based method, with the median execution time for a stream varying between 6 and 8 seconds vs. a median run time of 31 seconds for the PVWatts 5-based method.

azimuth↗

A Reproducible Validation of Algorithms for Estimating Array Tilt and Azimuth from Photovoltaic Power Time Series

In this research, we assess the viability of four different, publicly available algorithms for estimating the azimuth and tilt parameters of solar photovoltaic systems using only the associated AC power time series data and site latitude-longitude coordinates. In this work, we curated a benchmarking data set of 44 fixed-tilt systems, comprising 275 measured AC power inverter data streams, with known azimuth and tilt parameters. Additionally, we isolated test cases in the data set with real-world issues, including shading and clipping, to determine how algorithm performance varies based on the presence of these phenomena. Using this data set for benchmarking, we evaluated the estimated vs. actual system characteristics for each algorithm, as well as the associated algorithm execution time using a standardized benchmarking process. The two highest performing algorithms were the Solar Data Tools and the PVWatts 5-based methods, which both achieved a median absolute error of approximately 5 and 1 degrees for azimuth and tilt, respectively. During run time analysis, the SDT method was approximately 5 times faster than the PVWatts 5-based method, with the median execution time for a stream varying between 6 and 8 seconds vs. a median run time of 31 seconds for the PVWatts 5-based method.

algorithm validation↗

Updated sustainability status of cadmium telluride thin‐film photovoltaic systems and projections

This paper provides a comprehensive assessment of the up-to-date life-cycle sustainability status of cadmium-telluride based photovoltaic (PV) systems. Current production modules (Series 6 and Series 7) are analyzed in terms of their energy performance and environmental footprint and compared with the older series 4 module production and current single-crystalline Silicon (sc-Si) module production. For fixed-tilt systems with Series 6 modules operating under average US irradiation of 1800 kWh/m 2 /year, the global warming potential (GWP) is reduced from 16 g CO 2eq /kWh in Series 4 systems to 10 CO 2 eq /kWh in Series 6 systems. For operation in US-SW irradiation of 2300 kWh/m 2 /year, the GWP is reduced from 11 to 8 CO 2eq /kWh and for 1-axis tracking systems operating in Phoenix, Arizona, with point-of array irradiation of 3051 kWh/m 2 /year the GWP is reduced to 6.5 CO 2eq /kWh. Similar reductions have happened in all environmental indicators. Energy payback times (EPBT) of currently installed systems range from 0.6 years for fixed–tilt ground–mounted installations at average US irradiation at latitude tilt installations to 0.3 years for one-axis trackers at high US-SW irradiation, considering average fossil-fuel dominated electricity grids with fuel to electricity conversion efficiency of 0.3. The resulting energy return on energy investment (EROI) also depends on the conversion efficiency of the electricity grid and on the operation life expectance. For a 30-year operational life and grid conversion efficiency of 0.3, EROI ranges from 50 (at US average irradiation) to 70 for US-SW irradiation. The EROI declines with increased grid conversion efficiency; for CdTe PV operating in south California with grid conversion efficiency of 49%, the EROI is about 50 and is projected to fall to 30 when the state's 2030 target of 80% renewable energy penetration materializes. Material alternatives that show a potential of further reductions in degradation rates and materials for enhanced encapsulation that would enable longer operation lives have also been investigated. A degradation rate of 0.3%/year, which has been verified by accelerated testing, is assumed in 30-year scenarios; this is projected to be reduced to 0.2%/year in the near-term and potentially to 0.1%/year in the longer term. With such low degradation rates and enhanced edge-sealing, modules can last 40- to 50-years. Consequently, all impact indicators will be proportionally reduced while EROI will increase. This detailed LCA was conducted according to ISO standards and IEA PVPS Task 12 guidelines. Furthermore, the study revealed that the choices of system models, methods and temporal system boundaries can significantly impact the results and points out to the need to include assumptions regarding these choices in the “transparency in reporting” requirements listed in the IEA PVPS Task 12 Guidelines.

14 SOLAR ENERGY↗

Structure of Layers Formed by [2-(3,6-Disubstituted-9 H -carbazol-9-yl)ethyl]phosphonic Acids on Metal Oxides

[2-(9 H -Carbazol-9-yl)ethyl]phosphonic acid (2PACz) and its derivatives are being used extensively as hole-transport layers in organic and perovskite solar cells due to their ability to modify electrode work function, surface wettability, and in some cases, to improve active-layer adhesion, while minimizing interfacial energy losses. The orientation and coverage of surface modifiers significantly impact these functional properties; however, the detailed structure and packing in these overlayers are challenging to investigate, leading to a lack of understanding of how this structure and packing influence performance and limiting the ability to rationally design molecular modifiers. Here, we investigate monolayers of 2-(9 H -carbazol-9-yl)ethyl phosphonic acid derivatives (from here on referred to as X-2PACz) on indium tin oxide (ITO) and alpha phase aluminum oxide (α-Al 2 O 3 ) using a combination of X-ray photoelectron spectroscopy (XPS), near-edge X-ray absorption fine structure (NEXAFS) spectroscopy, and X-ray reflectivity (XRR). By correlating elemental ratios, molecular orientation, and electron density profiles, we directly quantify surface coverage, layer thickness, and molecular tilt across a series of chemically related monolayers. We find that 2PACz and the X-2PACz derivatives form dense monolayers on α-Al 2 O 3 and ITO, with similar surface coverages on either substrate that are inversely proportional to molecular steric bulk. These surface coverage results indicate that X-2PACz is sterically limited in its monolayer surface packing density, as opposed to site limited. Despite surface packing density differences between molecules, the NEXAFS data show a constant average molecular orientation of 61° to 65° between the plane of the carbazole and the substrate for all the molecules on both substrates. These results increase our general understanding of 2PACz derivatives as they become increasingly useful in high performance solar cells.

NEXAFS↗

Grain boundary segregation and chemical ordering in CoCrFeMnNi multi-principal element alloy

Owing to their far-from-dilute compositions, multi-principal element alloys (MPEAs) can exhibit unique combinations of engineering properties. As nearly all MPEAs are polycrystalline aggregates, it is necessary to understand the interactions of various elemental species with grain boundaries (GBs). This is of particular importance in extreme environments, such as radiation and elevated temperatures, where such interactions have implications on the properties of MPEAs. Herein, we employ atomistic simulations to generate a series of [001] asymmetric tilt GBs in a model CoCrFeMnNi MPEA and quantify solute interactions and segregation to these boundaries. We employ the Warren-Cowley order parameters to investigate the interplay between GB segregation and chemical short-range order (SRO). At temperatures above 800 K, simulation results reveal the segregation of Cr and Mn to CoCrFeMnNi GBs and show weak dependence of boundary solute excess on GB geometry, at least for the boundaries explored in this work. At temperatures in the range of 673–800 K, formation of domains rich in Cr is observed at GBs in agreement with experimental observations. Quantitative analysis shows that solute excess of various alloying elements decreases rapidly with the increase in temperature in the range of 1000–1200 K. Furthermore, we show that GB regions exhibit SRO characteristics that are distinct from the bulk crystals, leading to spatial variations in SRO. In broad terms, our study highlights the need to account for GB interactions with alloying elements when designing advanced MPEAs with novel chemistries.

Wang, Yitao [Lehigh University, Bethlehem, PA (Uni↗

Slant, Fan, and Narrow: The Response of Stellar Streams to a Tilting Galactic Disk

Stellar streams are sensitive tracers of the gravitational potential, which is typically assumed to be static in the inner Galaxy. However, massive mergers like Gaia-Sausage-Enceladus can impart torques on the stellar disk of the Milky Way that result in the disk tilting at rates of up to 10°–20° Gyr –1 . Here, we demonstrate the effects of disk tilting on the morphology and kinematics of stellar streams. Through a series of numerical experiments, we find that streams with nearby apocenters (r apo ≲ 20 kpc) are sensitive to disk tilting, with the primary effect being changes to the stream's on-sky track and width. Interestingly, disk tilting can produce both more diffuse streams and more narrow streams, depending on the orbital inclination of the progenitor and the direction in which the disk is tilting. Our model of Pal 5's tidal tails for a tilting rate of 15° Gyr –1 is in excellent agreement with the observed stream's track and width, and reproduces the extreme narrowing of the trailing tail. We also find that failure to account for a tilting disk can bias constraints on shape parameters of the Milky Way's local dark matter distribution at the level of 5%–10%, with the direction of the bias changing for different streams. Disk tilting could therefore explain discrepancies in the Milky Way's dark matter halo shape inferred using different streams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A study of Cell Cracks Formation During Freight Shipping : Monitoring Shock and Temperature in Real-Time & Assessing Damages With Pre and Post-Transit Characterizations of PV Modules

The solar photovoltaic (PV) industry often experiences module damage during transportation. PV modules stacked horizontally and strapped on wooden pallets may develop failures impacting their efficiency (glass shattering, cracks, frame indentation, etc.), especially when modules are not packed by professionals. The appearance of failures during the shipment from one laboratory to another can be detrimental to research studies. In this study, we tested a reusable plastic pallet designed to ship modules vertically. Five technologies of commercial PV modules were shipped together from Arizona to Florida including: glass/glass bifacial modules (framed and frameless), glass/transparent backsheet bifacial modules and glass/white backsheet modules (framed). Each module technology has a different physical size. Some modules had pre-existing cell-cracks allowing for the study of cell-crack formation and propagation during shipment. Dark current-voltage (I-V), light I-V and electroluminescence characterization were performed before and after shipment. A datalogger was used to monitor shocks and ambient temperature throughout the shipment and identify when the modules were more susceptible to damage. The modules were tilted upon receipt and the pallet were damaged but with no shattered modules. Time series shock data provided by the datalogger were used to determine potential responsible events. Our results reveal a few new post-transportation cracks for some modules. Modules parameters before and after shipment are also compared regarding the module constructions and their position in the pallet.

14 SOLAR ENERGY↗