Computer program documentation - SYSTID, system time-domain simulation program
SYSTID computer program for system time-domain simulation program in FORTRAN 5 for Univac 1108 computer
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
SYSTID computer program for system time-domain simulation program in FORTRAN 5 for Univac 1108 computer
Description of the basic principles of radar measurements of cryogenic liquid levels in storage vessels by time-domain reflectometry. The probe consists of a right circular coaxial transmission line positioned vertically in the storage vessel and having holes drilled in the outer conductor to permit penetration of the liquid into the annular gap. RF pulses transmitted through the probe are reflected at liquid/gas interface and returned for sampling at the input. The measured delay of the return pulse is displayed as the level of liquid in the vessel.
Applicability of nonlinear time domain analysis to problem of modeling human operator /pilot/
Transient analysis for uniform RC structures using impulse excitations in open and short circuit configurations
Human controllers nonlinear time domain mathematical model for analyzing compensatory tracking task data
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A technique is presented for the design of frequency-sampling and transversal digital filters from specified unit-impulse responses. The multiplier coefficients for the digital filter are specified by the use of a linear-programming algorithm. Examples include the design of digital filters to generate intersymbol-free pulses for data transmission over ideal bandlimited channels and to equalize data transmission channels that have known unit-impulse responses.
The problem considered is the design of a feedback system containing a linear, time invariant, minimum phase plant, whose parameters are known only within given bounds, such that the time response of the system remains within specified limits. A quasi-optimal design, for given design constraints, is one which minimizes the effect of white sensor noise on the input to the plant. An investigation was conducted on the use of the non linear device known as the Clegg integrator in the design of such a system. The describing function of the Clegg integrator has the same magnitude characteristic, apart from a scale factor, as the linear integrator, but has 52 deg less phase-lag, at all frequencies, than the linear integrator; thus, when used in a feedback system, it provides a larger stability margin than the linear integrator. This property allows the nonlinear feedback system to be designed so that the sensor noise is attenuated more than in the linear design.
Time-domain and frequency domain statistics for random step-wise sampled data systems
Automated modeling and structure optimization of linear dynamic systems and circuits, using hybrid computer techniques and time-domain test data
Some problems associated with the design of model-reference adaptive control systems are considered and solutions to these problems are advanced. The stability of the adapted system is a primary consideration in the development of both the time-domain and the frequency-domain design techniques. Consequentially, the use of Liapunov's direct method forms an integral part of the derivation of the design procedures. The application of sensitivity coefficients to the design of model-reference adaptive control systems is considered. An application of the design techniques is also presented.
There is given a minimum-phase plant transfer function, with prescribed bounds on its parameter values. The plant is imbedded in a two-degree-of freedom feedback system, which is to be designed such that the system time response to a deterministic input lies within specified boundaries. Subject to the above, the design should be such as to minimize the effect of sensor noise at the input to the plant. This report presents a design procedure for this purpose, based on frequency response concepts. The time-domain tolerances are translated into equivalent frequency response tolerances. The latter lead to bounds on the loop transmission function in the form of continuous curves on the Nichols chart. The properties of the loop transmission function which satisfy these bounds with minimum effect of sensor noise, are derived.
Concepts and techniques for identifying and simulating both the steady state and dynamic characteristics of electrical loads for use during integrated system test and evaluation are discussed. The investigations showed that it is feasible to design and develop interrogation and simulation equipment to perform the desired functions. During the evaluation, actual spacecraft loads were interrogated by stimulating the loads with their normal input voltage and measuring the resultant voltage and current time histories. Elements of the circuits were optimized by an iterative process of selecting element values and comparing the time-domain response of the model with those obtained from the real equipment during interrogation.
Two independent models simulate dynamic and steady-state responses of electrical and electronic equipment under power load. One is resistance/capacitance/inductance network, and the other is variable resistance analog device. Resistance, inductance, and/or capacitance are selected by iterative process; time-domain response is compared with that of real equipment to select optimal values.
A new mean-square-error automatic equalizer for synchronous data transmission is developed. It utilizes Rosen's gradient-projection method to optimize parameters in the discrete frequency domain. The algorithm converges (in the mean) for any channel even in the presence of noise. It is shown that for the channels considered, convergence is faster (in a bounded sense) than for comparable time-domain equalizers.
The purpose of this paper is to summarize results for linear multivariable systems that are analogous to those single input single output systems which are 'type l', i.e., that contain l integrators. Both frequency domain and time-domain properties are given. Appropriate conditions that guarantee zero steady state error in tracking vector polynomial inputs are presented.
Methods are presented for representing unsteady aerodynamic loadings, valid for arbitrary motion, for the two-dimensional typical section with a trailing-edge control surface in incompressible flow and a three-dimensional lifting surface with leading- or trailing-edge control surfaces in subsonic compressible flow. Loads for the two-dimensional incompressible case are obtained via analytic continuation of the Theodorsen function into the complex plane, with guidance from a time-domain approximation of the Wagner indicial function. For the three-dimensional case, it is proposed that oscillatory generalized aerodynamic forces be approximated by Pade fractions, thereby permitting an obvious continuation into the complex plane. A theoretical justification for this procedure is briefly outlined, and some practical aspects of its implementation are discussed.