Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Surface voltage gradient role in high voltage solar array-plasma interaction: Center Director's discretionary fund

A large amount of experimental and analytical effort has been directed toward understanding the plasma sheath growth and discharge phenomena which lead to high voltage solar array-space plasma interactions. An important question which has not been addressed is how the surface voltage gradient on such an array may affect these interactions. The results of this study indicate that under certain conditions, the voltage gradient should be taken into account when evaluating the effect on a solar array operating in a plasma environment.

Carruth, M. R., Jr.↗

Insulator edge voltage gradient effects in spacecraft charging phenomena

Insulating surfaces on geosynchronous satellites have been charged by geomagnetic substorms to a point where discharges occur. The electromagnetic pulses from these discharges couple into satellite electronic systems disrupting operations. Laboratory tests conducted on insulator charging have indicated that discharges appear to be initiated at insulator edges where voltage gradients can exist. An experimental investigation has been conducted to measure edge voltage gradients on silvered Teflon samples as they are charged by monoenergetic electron beams. It has been found that the surface voltage at insulator edges can be approximated by an exponential expression based on an electron current density balance. Using this expression at known breakdown conditions results in a discharge voltage gradient down the insulator edge to ground of about 150,000 V/cm.

Stevens, N. J.↗

Insulator edge voltage gradient effects in spacecraft charging phenomena

Insulating surfaces on geosynchronous satellites were charged by geomagnetic substorms to a point where discharges occur. The electromagnetic pulses from these discharges couple into satellite electronic systems disrupting operations are examined. Laboratory tests conducted on insulator charging have indicated that discharges appear to be initiated at insulator edges where voltage gradients can exist. An experimental investigation was conducted to measure edge voltage gradients on silvered Teflon samples as they are charged by monoenergetic electron beams. It was found that the surface voltage at insulator edges can be approximated by an exponential expression based on an electron current density balance.

Stevens, N. J.↗

Voltage gradients in solar array cavities as possible breakdown sites in spacecraft-charging-induced discharges

A possible explanation for environmentally-induced discharges on geosynchronous satellites exists in the electric fields formed in the cavities between solar cells - the small gaps formed by the cover slides, solar cells, metallic interconnects and insulating substrate. When exposed to a substorm environment, the cover slides become less negatively charged than the spacecraft ground. If the resultant electric field becomes large enough, then the interconnect could emit electrons (probably by field emission) which could be accelerated to space by the positive voltage on the covers. An experimental study was conducted using a small solar array segment in which the interconnect potential was controlled by a power supply while the cover slides were irradiated by monoenergetic electrons. It was found that discharges could be triggered when the interconnect potential became at least 500 volts negative with respect to the cover slides. Analytical modeling of satellites exposed to substorm environments indicates that such gradients are possible. Therefore, it appears that this trigger mechanism for discharges is possible.

Stevens, N. J.↗

Voltage gradients in solar array cavities as possible breakdown sites in spacecraft-charging-induced discharges

A possible explanation for environmentally-induced discharges on geosynchronous satellites exists in the electric fields formed in the cavities between solar cells - the small gaps formed by the cover slides, solar cells, metallic interconnects and insulating substrate. When exposed to a substorm environment, the cover slides become less negatively charged than the spacecraft ground. Hence, it is possible for metallic surfaces (usually silver mesh) to be at a negative potential in a cavity that has a 'positive' surface above it. If the resultant electric field becomes large enough, then the interconnect could emit electrons (probably by field emission) which could be accelerated to space by the positive voltage on the covers. An experimental study was connected using a small solar array segment in which the interconnect potential was controlled by a power supply while the cover slides were irridated by monoenergetic electrons. It was found that discharges could be triggered when the interconnect potential became at least 500 volts negative with respect to the cover slides. Analytical modeling of satellites exposed to substorm environments indicates that such gradients are possible. Therefore, it appears that this trigger mechanism for discharges is possible. Details of the experiment and modeling study are presented.

Stevens, N. J.↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

The dc arc characteristics in subsonic orifice nozzle flow

The cold air flow field for a 1/27 cm orifice nozzle was determined for subsonic flow velocities. In addition, d.c. arc voltage, current, and diameter measurements were made for a range of velocities and arc gaps. Average voltage gradients increased rapidly as an arc extinguishing velocity was approached. Measured values of current and diameter were used as an input for relaxation solution of an energy balance equation to compute radial temperature profiles. Calculated arc voltage gradients compare favorably with measured average voltage gradients.

Nagamatsu, H. T.↗

Application of engineering codes to the assessment of spacecraft charging induced hazards

One of the major hurdles to developing a better understanding of the environmentally induced interactions in spacecraft systems (spacecraft charging) is the lack of simple tools to analyze the behavior of the spacecraft in a sub-storm environment. The available tool, NASA Charging Analyzer Program (NASCAP), is expensive to use and treats only half of the problem - surface effects only. In response to this need, we have developed, under our IRAD Program, a set of engineering tools that operate on personal computers and addresses both the surface and bulk charging aspects of the interactions. These engineering codes utilize circuit analysis techniques and model simplifications to allow rapid computations. The codes were compared to both NASCAP predictions and to bulk charging data with excellent agreement for both phenomena. The models used in our engineering codes are shown, and in the engineering codes, the models are defined in terms of plates or triangles in an unconfined space. The predictions are based upon current balances to each plate. The code has routines to allow interactions between the plates to simulate 'barrier' effects. The agreement for the predicted differential surface voltages for the model is given. In conducting the comparison of engineering codes to NASCAP predictions, it was found that some inconsistencies existed in the NASCAP code that are not obvious to the user. The use of the grid imposes constraints that voltage gradients exist between the grid points. This allows the existence of voltage gradients in conductors and influences surface resistivity predictions. These points are discussed along with the predictions for treating these inconsistencies properly. The model predictions for a variable intensity substorm is also presented.

Stevens, N. J.↗

Plasma electron collection through biased slits in a dielectric

A large number of experimental and analytical efforts have been directed toward understanding the plasma sheath growth and discharge phenomena which lead to high-voltage solar array/space plasma interactions. An important question which has not been addressed is how the voltage gradient in the plasma sheath near the surface of such an array may affect these interactions. The purpose of the experimental study described in this paper is to examine the merging of the sheaths around biased slits in a dielectric and how this affects the collection of electrons through these slits. The data, which are obtained by emissive probes and direct measurement of the current collected through the slits, indicate that when the sheaths merge the current collection by the slits is significantly altered with the most positive slit collecting more electrons than it otherwise would. Therefore, the effect of a voltage gradient in the sheath around a solar array should be considered when evaluating solar array performance.

Carruth, M. R., Jr.↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Quasi-steady plasma acceleration.

A coaxial plasma accelerator driven by protracted pulses of current in the range of 10,000 to 100,000 A and synchronized mass flows from 1.0 to 36 g/sec argon attains, after some tens of microseconds, a stable magnetoplasmadynamic acceleration mode. This 'quasi-steady' discharge form is characterized by constant terminal voltage and current, a diffuse, fixed current distribution within the discharge, and a steady plasma efflux at velocities of approximately 20 km/sec. Measured potential distributions reveal that the bulk of the arc voltage gradient, exclusive of the electrode falls, occurs within two diameters of the cathode, and is normal to it. The anode fall voltage varies inversely with local current density, implying substantially lower anode losses at higher power arc operation. Spectroscopic, potential, and velocity measurements indicate the existence of a characteristic mass flow rate for a given current, below which arc operation becomes erratic.

Jahn, R. G.↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyancy-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chambers are used, distortion of the injected sample stream due to electrohydrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field have not been considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyance-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chamber are used, distortion of the injected sample stream due to electrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field were not considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

AMPPED LDRD: Advanced Models of the Physics & Phenomena of Electrical Discharge.

This Laboratory Directed Research and Development (LDRD) project aimed at addressing an unmet need for physics-based models that enable prediction of electrical breakdown in the presence of high voltage gradients and real-world environments. This project focused on understanding coupled plasma-surface feedback phenomena critical to electrical discharge processes and design of breakdown voltages, breakdown times, and breakdown paths. New secondary electron emission and coupled plasma-surface measurement methods and models were developed. Highly reproducible discharge experiments were developed to provide current-voltage data as a function of time, and methods were developed to condition electrodes for predictable discharge. To assess plasma-surface feedback mechanisms, new surface physics capabilities, including measurement systems for local and global photoemission yield and ion-induced secondary electron emission yield were developed. Discharge models were developed to incorporate these yields for predicting discharge behavior to understand influence of surface physics on discharge current and time evolution, and methods to accelerate these simulations were demonstrated. A key finding was that the initiation process of a non-vacuum discharge appears highly dependent on photoemission at the cathode. Advanced diagnostics were developed, including spatial electrical field imaging, spectroscopy of plasmas, and high-speed imaging of discharge event s in metal and dielectric environments. These diagnostics and improved electrical models are a step toward enabling quantitative design margins, assurance of safety architectures, and implementation of novel materials and technologies for wide ranging energy and electronics applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Environmentally induced discharges on satellites

A discharge process whose trigger conditions are a negative exposed metallic surface surrounded by a less negative dielectric, and a large voltage gradient at a dielectric/metal interface is proposed. Analysis of SCATHA data for a discharge substantiates the postulation. Surface discharges cause a small transient charge transfer to space which results in voltage transients. A method of computing these transients, based on the charge lost through the capacitance to space and a fraction of charge stored in the dielectric at the discharge source was developed. It gives an estimate of the discharge transients at the discharge site, which is used as input for coupling code analysis of structure/system response. The transient computations were applied to a three-axis stabilized, geosynchronous satellite for both sunlight and eclipse charging. The energy of the transient pulses are about 1 mJ for sunlight discharge and 8 mJ for eclipse. Changing of selected coatings on the satellite would relieve the stress.

Stevens, N. J.↗

Testing of typical spacecraft materials in a simulated substorm environment

An investigation to determine spacecraft materials characteristics under charging conditions was conducted at the Lewis Research Center substorm simulation facility. The test specimens were spacecraft paints, silvered Teflon, thermal blankets and solar array segments. The samples, ranging in size from 300 to 1,000 sq cm were exposed to monoenergetic electron energies from 2 to 20 keV at a current density of 1 nA sq cm. The samples generally behaved as capacitors with strong voltage gradients at their edges. The charging characteristics of the silvered Teflon, Kapton, and solar cell covers were controlled by the secondary emission characteristics. Insulators that did not discharge were the spacecraft paints and the quartz fiber cloth thermal blanket sample. All other samples did experience discharges when the surface voltage reached -8 to -16 kV. The discharges were photographed. The breakdown voltage for each sample was determined and the average energy lost in the discharge was computed.

Stephens, N. J.↗

Testing of typical spacecraft materials in a simulated substorm environment

The test specimens were spacecraft paints, silvered Teflon, thermal blankets, and solar array segments. The samples, ranging in size from 300 to 1000 sq cm were exposed to monoenergetic electron energies from 2 to 20 keV at a current density of 1 NA/sq cm. The samples generally behaved as capacitors with strong voltage gradient at their edges. The charging characteristics of the silvered Teflon, Kapton, and solar cell covers were controlled by the secondary emission characteristics. Insulators that did not discharge were the spacecraft paints and the quartz fiber cloth thermal blanket sample. All other samples did experience discharges when the surface voltage reached -8 to -16kV. The discharges were photographed. The breakdown voltage for each sample was determined and the average energy lost in the discharge was computed.

Stevens, N. J.↗