Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

AMPPED LDRD: Advanced Models of the Physics & Phenomena of Electrical Discharge.

This Laboratory Directed Research and Development (LDRD) project aimed at addressing an unmet need for physics-based models that enable prediction of electrical breakdown in the presence of high voltage gradients and real-world environments. This project focused on understanding coupled plasma-surface feedback phenomena critical to electrical discharge processes and design of breakdown voltages, breakdown times, and breakdown paths. New secondary electron emission and coupled plasma-surface measurement methods and models were developed. Highly reproducible discharge experiments were developed to provide current-voltage data as a function of time, and methods were developed to condition electrodes for predictable discharge. To assess plasma-surface feedback mechanisms, new surface physics capabilities, including measurement systems for local and global photoemission yield and ion-induced secondary electron emission yield were developed. Discharge models were developed to incorporate these yields for predicting discharge behavior to understand influence of surface physics on discharge current and time evolution, and methods to accelerate these simulations were demonstrated. A key finding was that the initiation process of a non-vacuum discharge appears highly dependent on photoemission at the cathode. Advanced diagnostics were developed, including spatial electrical field imaging, spectroscopy of plasmas, and high-speed imaging of discharge event s in metal and dielectric environments. These diagnostics and improved electrical models are a step toward enabling quantitative design margins, assurance of safety architectures, and implementation of novel materials and technologies for wide ranging energy and electronics applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancing the cooling performance of thermocouples: a power-constrained topology optimization procedure

Abstract Heat pumping through thermoelectric devices has many advantages over traditional cooling. However, their current efficiency is a limiting factor in their implementation. In this paper, we approach the non-convex topology optimization of thermoelectrical elements for cooling applications through the method of moving asymptotes (MMA) to improve their cooling capabilities per watt usage. The optimization problem is defined for a given power budget, aiming for the minimum temperature with a known heat pumping need. The introduction of power as a constraint justifies the introduction of the voltage gradient across the thermocouple as a design variable to maintain the thermoelectrical device in its optimum power-to-heat extraction ratio. To better understand the convergence of this non-convex problem, we present a two-variable analytical thermoelectric optimization model. This example provides information on how to select the penalty parameters used to scale the three material coefficients involved in the problem to obtain lower objective values and better convergence using MMA. The analytical model shows the non-convexity of the problem and provides the recommendation to use penalization coefficients of the form $$p_k=p_{\sigma }>p_{\alpha }=1$$ p k = p σ > p α = 1 for the thermal conductivity, electrical conductivity, and Seebeck coefficients. We tested these penalization coefficients through optimizations of a model based on the 1MC10-031 commercial thermoelectric-cooler (TEC) using the finite element method (FEM). These penalization coefficients provided local minima without the need for volume constraints. With this procedure, we found designs that provided temperatures close to 10 degrees lower using 60% less semiconductor material volume compared to the initial design.

Gutiérrez, G. Reales↗

Logic operations with active topological defects

Logic operations performed by semiconductor-based transistors are the basis of modern computing. There is considerable interest in creating autonomous materials systems endowed with the capability to make decisions. In this work, we introduce the concept of using topological defects in active matter to perform logic operations. When an extensile active stress in a nematic liquid crystal is turned on, +1/2 defects can self-propel, in analogy to electron transport under a voltage gradient. By relying on hydrodynamic simulations of active nematics, we demonstrate that patterns of activity, when combined with surfaces imparting certain orientations, can be used to control the formation and transport of +1/2 defects. We further show that asymmetric high- and low-activity patterns can be used to create effective defect gates, tunnels, and amplifiers. The proposed active systems offer the potential to perform computations and transmit information in active soft materials, including actin-, tubulin-, and cell-based systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cummins R-SOFC System Development

The overall purpose of this project was to reduce the Reversible-Solid Oxide Fuel Cell (R-SOFC) system cost by developing two technologies, an improved cell design and the incorporation of an ejector in the fuel recycle loop instead of a blower. A Simulink model of the baseline SOFC system was developed and calibrated with experimental test data. The R-SOFC system model was built by integrating GT Suite developed models of the steam generation components into the baseline Simulink SOFC system model. The ability to run the stack in SOEC operating mode was also added to the model. The system model was used to explore the ability of the R-SOFC system to meet operational constraints on Steam/Carbon ratio and H2 concentration on the fuel side electrode. A CFD ejector model was developed and used to explore a range of ejector design parameters, leading to the final ejector design that was prototyped for testing. A prototype steam ejector was first tested in a laboratory environment using room temperature air. The steam ejector was subsequently tested using the full hot recycle loop with all relevant heat exchangers and steam generation components. The test conditions utilized temperatures, pressures, and flow rates expected in an R-SOFC application. Throughout the experimental testing work, ejector performance test data was used to improve and then validate the CFD ejector model. A CFD cell model was developed and used to optimize thermal gradients, voltage, and cost of a new cell substrate design. A CFD comparison of co-flow and cross-flow cell designs informed the decision to use a co-flow design for the new cell substrate. Multiple rounds of CFD simulation were used to improve the cell design to minimize the variation in air and fuel distribution across cell channels and to minimize the variation in air and fuel distribution across different cells in the stack. A few prototypes of the new cell substrate design were produced and validated in a laboratory environment by thermally spraying and verifying that they met established manufacturing specifications. The cell manufacturing process was adjusted in order to bring these metrics within acceptable tolerances. Cummins’ internal calculations show that the new cell design reduces cost ~50% compared to the baseline cell, while the ejector + superheater/boiler concept reduces cost of the recycle loop by ~40%. The impact of these cost reductions on the cost of producing H2 will depend on the specific system where they are applied. Therefore, a Techno-Economic Analysis was completed using system cost as a variable, and showing how the NREL Current and Future system costs translate into H2 production cost.

Henrichsen, Lars↗

Product ion distributions using H 3 O + proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS): mechanisms, transmission effects, and instrument-to-instrument variability

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) using hydronium ion (H3O+) ionization is widely used for the measurement of volatile organic compounds (VOCs) both indoors and outdoors. H3O+ ionization, as well as the associated chemistry in an ion–molecule reactor, is known to generate product ion distributions (PIDs) that include other product ions besides the proton-transfer product. We present a method, using gas-chromatography pre-separation, for quantifying PIDs from PTR-MS measurements of nearly 100 VOCs of different functional types including alcohols, ketones, aldehydes, acids, aromatics, organohalides, and alkenes. We characterize instrument configuration effects on PIDs and find that reactor reduced electric field strength (E/N), ion optic voltage gradients, and quadrupole settings have the strongest impact on measured PIDs. Through an interlaboratory comparison of PIDs measured from calibration cylinders, we characterized the variability of PID production from the same model of PTR-MS across seven participating laboratories. Product ion variability was generally smaller (e.g., < 20 %) for ions with larger contributions to the PIDs (e.g., > 0.30) but less predictable for product ions formed through O2+ and NO+ reactions. We present a publicly available library of H3O+ PTR-MS PIDs that will be updated periodically with user-provided data for the continued investigation into instrument-to-instrument variability of PIDs.

Link, Michael F. (ORCID:0000000218412455)↗

Origin of transverse voltages generated by thermal gradients and electric fields in ferrimagnetic-insulator/heavy-metal bilayers

We compare thermal-gradient-driven transverse voltages in ferrimagnetic-insulator/heavy-metal bilayers (Tm 3 Fe 5 O 12 /W and Tm 3 Fe 5 O 12 /Pt) to corresponding electrically driven transverse resistances at and above room temperature. We find for Tm 3 Fe 5 O 12 /W that the thermal and electrical effects can be explained by a common spin-current detection mechanism, the physics underlying spin Hall magnetoresistance (SMR). However, for Tm 3 Fe 5 O 12 /Pt the ratio of the electrically driven transverse voltages (planar Hall signal/anomalous Hall signal) is much larger than the ratio of corresponding thermal-gradient signals, a result which is very different from expectations for a SMR-based mechanism alone. Here, we ascribe this difference to a proximity-induced magnetic layer at the Tm 3 Fe 5 O 12 /Pt interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards advanced polarized electron sources

Polarized electrons play an important role in high-energy and nuclear physics, and their properties have also been exploited in ultrafast electron microscopy. Currently, gallium arsenide crystals illuminated by circular polarized infrared laser light are commonly used for generating polarized electrons. However, the achievable accelerating voltage and the gradient of these electrostatic sources limit the beam quality and quantity. A solution could be to combine gallium arsenide photocathodes with radio-frequency electron guns, which are capable of accelerating beams with significantly higher gradients and voltage. Here we report the successful operation of a gallium arsenide photocathode in a superconducting radio-frequency gun. Our findings are relevant for future sources of polarized electrons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Specificity and tunability of efflux pumps: A new role for the proton gradient?

Efflux pumps that transport antibacterial drugs out of bacterial cells have broad specificity, commonly leading to broad spectrum resistance and limiting treatment strategies for infections. It remains unclear how efflux pumps can maintain this broad spectrum specificity to diverse drug molecules while limiting the efflux of other cytoplasmic content. We have investigated the origins of this broad specificity using theoretical models informed by the experimentally determined structural and kinetic properties of efflux pumps. We developed a set of mathematical models describing operation of efflux pumps as a discrete cyclic stochastic process across a network of states characterizing pump conformations and the presence/absence of bound ligands and protons. These include a minimal three-state model that lends itself to clear analytic calculations as well as a five-state model that relaxes some of the simpler model’s most strict assumptions. We found that the pump specificity is determined not solely by the drug affinity to the pump–as is commonly assumed–but it is also directly affected by the periplasmic pH and the transmembrane potential. Therefore, changes to the proton concentration gradient and voltage drop across the membrane can influence how effective the pump is at extruding a particular drug molecule. Furthermore, we found that while both the proton concentration gradient across the membrane and the transmembrane potential contribute to the thermodynamic force driving the pump, their effects on the efflux enter not strictly in a combined proton motive force. Rather, they have two distinguishable effects on the overall throughput. These results highlight the unexpected effects of thermodynamic driving forces out of equilibrium and illustrate how efflux pump structure and function are conducive to the emergence of multidrug resistance.

59 BASIC BIOLOGICAL SCIENCES↗

Low-cost gradient amplifiers for small MRI systems

Here, we describe low-cost gradient amplifiers for small MRI systems, such as those based on small/medium permanent magnets. The requirements for MRI gradient amplifiers are quite similar to those of modestly priced audio stereo power amplifiers. Such amplifiers for sound service can be modified to be DC coupled, extending their response down to zero frequency, as needed for MRI gradient service. We describe such modifications to one unit (Samson Servo 600) and mention a commercially available modification of another. The 600 is capable of an output greater than ±8 A and ±60 V, much greater than our needs for a greenhouse MRI. Audio amplifiers can be used this way as controlled voltage (CV) gradient amplifiers, with acceptable performance because the gradient coils typically have short L/R time constants. Superior performance can be had by using a controlled current (CC) “front end”; the circuit of our simple front end is included. The complete 3-axis CC system costs about $1200.

47 OTHER INSTRUMENTATION↗

Stabilizing Ni-rich layered cathode for high-voltage operation through hierarchically heterogeneous doping with concentration gradient

High-nickel LiNi x Mn y Co 1-x-y O 2 (NMC) cathodes have demonstrated superior energy density, yet their stability is compromised under high voltage conditions. To address this, here we propose a strategy of heterogeneous doping with a concentration gradient, specifically through Sr–Zr co-modification. We synthesized Ni-rich NMC particles featuring several micron-sized secondary particles composed of micron-sized primary grains. This design aims to harness the structural robustness of single-crystalline grains and the favorable diffusion kinetics of polycrystalline secondary particles. Systematic characterization using a combination of electrochemical measurements and synchrotron analytics reveals an intriguing pattern of hierarchically heterogeneous Sr–Zr co-doping. It demonstrates a depth-dependent concentration gradient at the secondary particle level and competing dopant segregation over the buried grain boundaries. This unique characteristic creates opportunities for enhancing battery performance, particularly by optimizing precursors and implementing advanced modulation techniques. We also investigate the dissolution and precipitation of the cathode's transition metal cations upon high-voltage cycling. These insights suggest that a tailored compositional variation can be a viable approach to effectively design the next-generation high-Ni NMC cathode materials for high-voltage lithium batteries.

36 MATERIALS SCIENCE↗

Electro-chemo-mechanically Driven Ni Exsolution from (Pr,Ce,Ni)O 2−δ : Controlled Nucleation Density and Enhanced Electrode Kinetics

In situ exsolution of metal nanoparticles is a promising strategy to prepare electrocatalysts with enhanced activity and resistance to agglomeration for efficient chemical transformations and energy conversion. Achieving a high nucleation density of nanoparticles under mild conditions and understanding how to tailor the process is important for performance of these electrodes in electrochemical cells. In this work, we demonstrate facile exsolution of Ni nanoparticles using fluorite-structured (Pr,Ce)O 2−δ as the support oxide, driven by electrochemical potential and aided by the metastability of Ni in the solid solution (elastic driving force). We prepare single-phase oriented thin films of (Pr,Ce,Ni)O 2−δ (NPCO) on (Zr,Y)O 2−δ (YSZ) substrates by pulsed laser deposition. With the aid of a high-throughput electrochemical cell that provides a lateral gradient in Nernst voltage, we apply in situ near-ambient pressure synchrotron X-ray photoelectron spectroscopy and ex situ atomic force microscopy to investigate the impact of electrochemical potential on Ni nucleation density. We find that metallic Ni can be successfully exsolved at 550 °C upon cathodic biasing in 20 mTorr O 2 , and its nucleation density increases with increasing electrochemical driving force/decreasing oxygen chemical potential. We further evaluate the electrochemical performance under highly reducing (fuel electrode) conditions by electrochemical impedance spectroscopy. With the exsolved Ni nanoparticles, the surface exchange coefficient of the NPCO is found to be ∼4× higher than for PCO without exsolution. This work confirms mixed conducting fluorites as beneficial host lattices for facile transition-metal exsolution and suggests the possibility for constructing an all ceria-based electrochemical cell with PCO serving as both the cathode and the anode.

36 MATERIALS SCIENCE↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

Development of an Optical Library for Coevaporated CdSe x Te 1– x

The conversion efficiency of CdTe solar cells may be improved by bandgap engineering, i.e., changing the bandgap value through the addition of Se in the absorber. The Se alloying enables a short-circuit current density improvement, as it leads to a bandgap energy value decrease. Furthermore, it has been associated with increased minority carrier lifetimes, assuring high open-circuit voltage values. An Se gradient profile control can further optimize the solar cell performance. Thus, an optical model baseline of the CdSe x Te 1–x (CST) compound was developed. Spectroscopic ellipsometry measurements were conducted to accurately extract the optical constants of ten CST layers deposited through coevaporation with x varying from 0 to 1. Using the measured dielectric function spectra from the discrete CST layers with varying x, and considering the composition-induced shift in the critical point energies, an energy-shift model was employed to develop the accurate optical library for the CST compound for any x value to provide data for future modeling and optimization. Furthermore, the library accuracy was validated through optical simulations of the quantum efficiency of a graded CST solar cell using the finite-difference time-domain method by replicating the Se profile in the absorber layer measured through secondary ion mass spectrometry.

14 SOLAR ENERGY↗

Preparation of asymmetric porous materials

As asymmetric porous film structure formed by depositing a porous material film on a flexible substrate, and applying an anisotropic stress to the porous media on the flexible substrate, where the anisotropic stress results from a stress such as an applied mechanical force, a thermal gradient, and an applied voltage, to form an asymmetric porous material.

36 MATERIALS SCIENCE↗