Search NASASearch

SEARCH · Search NASA

Results for “water balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Domestically Manufactured Fuel Cells for Heavy Duty Applications

This project, funded by the U.S. Department of Energy under Award DE-EE0009248, advances the domestic development of fuel-cell stack technologies for heavy-duty transportation applications. The work directly supports the Million-Mile Fuel Cell Truck (M2FCT) initiative by improving performance, durability, and manufacturability—key requirements for next-generation hydrogen fuel-cell systems.

08 HYDROGEN

High-voltage water-scarce hydrogel electrolytes enable mechanically safe stretchable Li-ion batteries

Soft Li-ion batteries, based on conventional organic electrolytes, face performance degradation challenges due to moisture penetration and safety concerns due to possible leakage of toxic fluorine compounds and flammable solvents under mechanical damage. We design a water-scarce hydrogel electrolyte with fluorine-free lithium salt to achieve wide electrochemical stability window (up to 3.11 volts) in ambient air without hermetic packaging while balancing high stretchability (1348%), ion conductivity (41 millisiemens per centimeter), and self-healing capabilities for mechanically and chemically safe stretchable Li-ion batteries. Molecular synergy between hydrophilicity and lithiophilicity of zwitterionic polymer backbone is revealed by molecular dynamics simulations. The battery exhibits capacity retention under harsh mechanical stresses—enduring stretching, twisting, folding, and multiple through-punctures by a needle—while self-healing from repeated through cuts by a razor blade. Stable ambient operation for 1 month over 500 charge-discharge cycles (average coulomb efficiency, 95%) is achieved. A prototype self-healing electronic system with embedded soft batteries demonstrates practical application as a durable embodied energy source.

Science & Technology - Other Topics

Battery model for electrical power system energy balance

A model to simulate nickel-cadmium battery performance and response in a spacecraft electrical power system energy balance calculation was developed. The voltage of the battery is given as a function of temperature, operating depth-of-charge (DOD), and battery state-of-charge. Also accounted for is charge inefficiency. A battery is modeled by analysis of the results of a multiparameter battery cycling test at various temperatures and DOD's.

Hafen, D. P.

Battery Cell Balancing System and Method

A battery cell balancing system is operable to utilize a relatively small number of transformers interconnected with a battery having a plurality of battery cells to selectively charge the battery cells. Windings of the transformers are simultaneously driven with a plurality of waveforms whereupon selected battery cells or groups of cells are selected and charged. A transformer drive circuit is operable to selectively vary the waveforms to thereby vary a weighted voltage associated with each of the battery cells.

Davies, Francis J.

Spacecraft thermal balance testing using infrared sources

A thermal balance test (controlled flux intensity) on a simple black dummy spacecraft using IR lamps was performed and evaluated, the latter being aimed specifically at thermal mathematical model (TMM) verification. For reference purposes the model was also subjected to a solar simulation test (SST). The results show that the temperature distributions measured during IR testing for two different model attitudes under steady state conditions are reproducible with a TMM. The TMM test data correlation is not as accurate for IRT as for SST. Using the standard deviation of the temperature difference distribution (analysis minus test) the SST data correlation is better by a factor of 1.8 to 2.5. The lower figure applies to the measured and the higher to the computer-generated IR flux intensity distribution. Techniques of lamp power control are presented. A continuing work program is described which is aimed at quantifying the differences between solar simulation and infrared techniques for a model representing the thermal radiating surfaces of a large communications spacecraft.

G. B. T. Tan

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

Design Trade-Offs in Composite Fuel Cell Membranes: Effects of Reinforcement and Chemical Additives

Perfluorosulfonic acid (PFSA) membranes are critical components in proton exchange membrane fuel cells, where performance depends on balancing ionic conductivity, mechanical durability, and chemical stability. This study characterizes a composite membrane (NC700) featuring PFSA-impregnated expanded polytetrafluoroethylene (ePTFE) reinforcement and cerium-based radical scavengers, benchmarked against unreinforced NR211. Complementary techniques, including electron microscopy, X-ray scattering, infrared spectroscopy, thermogravimetric analysis, and dynamic mechanical analysis, identify the structural and compositional strategies employed in NC700. Water sorption isotherms reveal lower water uptake for NC700 across all conditions, attributed to reinforcement and cerium incorporation. Reinforcement reduces in-plane swelling from 11% to 2.1% at 90% RH, confirming strong swelling anisotropy, while maintaining mechanical properties at elevated temperatures. While the ionic conductivity of NC700 is approximately 10% lower than that of NR211, the reduced thickness yields a 40% decrease in calculated area-specific resistance, suggesting the composite architecture can favorably shift the conductivity-stability trade-off. The composite structure also reduces gas permeability, indicating potential for improved separator function alongside favorable transport properties. Systematic deconvolution of reinforcement and additive contributions shows that conductivity losses from cerium incorporation are largely offset by gains from the lower equivalent-weight polymer, providing quantitative relationships that may guide composite membrane design for fuel cells and other electrochemical applications.

25 ENERGY STORAGE

Petermann Glacier on the Brink: Progress, Challenges and Insights

Petermann Glacier, the largest marine-terminating glacier in northern Greenland based on catchment area and ice discharge, plays a key role in regulating ice discharge from the Greenland Ice Sheet into the Arctic Ocean. With an upstream catchment connected to the ice sheet interior via a deep subglacial canyon, its future stability has major implications for sea level rise. In this review, we synthesize recent advances in understanding Petermann’s dynamics across three critical interfaces: the ice–ocean, ice–atmosphere, and ice–bed boundaries. At the surface, observations show that reanalysis products underestimate air temperatures and melt, while regional climate models diverge significantly in their estimates of surface mass balance, underscoring the need for improved in situ data and models. At the ocean boundary, enhanced basal melting driven by both subglacial runoff and Atlantic water intrusions is identified as the dominant driver of recent mass loss of Petermann Glacier, with continued warming posing a serious threat to the stability of the floating tongue. At the bed, new geophysical synthesis reveals complex geology, likely spatial variability in geothermal heat flux, and the influence of the megacanyon on seasonal hydrology and velocity fluctuations. Petermann’s mass balance has been negative in recent decades without corresponding flow acceleration. However, the glacier has undergone significant calving events, and the current rifting that began in September 2025 highlights its vulnerability. This upcoming calving event underscores the timeliness of this review, as it will put Petermann Glacier’s terminus at its most retreated position since records began in 1923. The anticipated retreat of the ice tongue also reduces buttressing and brings the terminus closer to the grounding zone, and modeling studies suggest that calving within 12 km of the grounding zone could potentially trigger dynamic retreat, accelerating ice discharge, and a doubling of flow speeds. We conclude that improved observations, sustained monitoring of oceanographic and atmospheric properties, and high-resolution modeling are critical to constraining projections of Petermann Glacier’s future and its role in the stability of the Greenland Ice Sheet.

Dominik Fahrner

Seasonal variation of the surface cross-shelf exchange in the northern South China Sea: a Lagrangian perspective

Previous studies on cross-shelf exchange, predominantly adopted an Eulerian perspective, struggled to identify water sources and pathways. Using a high-resolution regional ocean modeling system (ROMS) and Lagrangian particle tracking, this study systematically investigates the seasonal variation and dynamics of surface cross-shelf exchange in the northern South China Sea (NSCS) from a Lagrangian perspective. Based on daily released 30-day drifter trajectories we identify the key pathways, source regions for surface cross-shelf exchange, revealing pronounced seasonal variability. Results show the surface cross-shelf exchange generally following monsoon-driven Ekman transport. However, local dynamics, especially topographic modulation, can outweigh the expected Ekman-driven transport, producing surface exchange patterns opposite to that predicted from the prevailing winds. Topographic effects vary across different scales. In the coastal waters of western Guangdong during winter, despite downwelling-favorable winds, the modulation of alongshore currents by island topography induces an eastward pressure gradient. This gradient, through geostrophic balance, drives offshore flows opposite to wind-driven Ekman onshore transport. Furthermore, the eastern widened shelf exhibits a distinct seasonal variation of cross-shelf exchange, with strong offshore transport (opposite to the direction of Ekman transport) in winter and exceedingly weak exchange in summer. Analysis of the underlying mechanisms reveals that this winter offshore transport is primarily attributed to geostrophic flows driven by surface pressure gradient that is jointly modulated by the Kuroshio intrusion and local widened shelf topography, and enhanced by cumulative submesoscale processes. In summer, a persistent and strong along-isobath jet acts as a dynamic barrier, effectively suppressing the exchange. These findings highlight the important role of topography in regulating surface material transport, and have important implications for predicting the advection and dispersion of plankton or oil spills over the continental shelf influenced by monsoon.

Hao, Dongliang

Material efficiency technologies in the food and beverage industry

The U.S. food and beverage (F&B) sector is a major contributor to manufacturing gross domestic product and supports substantial employment and economic activity, while exerting significant pressures on land and water resources. At the same time, the industry faces growing expectations to balance its resource-intensive operations without compromising cost competitiveness. Material inefficiencies across the F&B value chain, particularly in raw material use and product loss/waste, lead to substantial financial losses and resource depletion. Thus, the F&B sector requires adoption of solutions and measures to avoid food wastage, reduce raw material consumption and valorize waste to high-value added products. This work presents a comprehensive understanding of the various technology solutions available for the F&B sector. The following two research questions are addressed: “What are the mid-to-high Technology Readiness Level technologies or measures to reduce material use and enable waste valorization in the F&B sector? What are the barriers to their commercial deployment? Additionally, what targeted research and development efforts are needed to overcome these barriers and accelerate their scale-up?” The findings are intended to support evidence-based decision-making, guide strategic investment, and help stakeholders strengthen resilience and competitiveness across the F&B sector.

Nain, Preeti [ORNL] (ORCID:0000000258358959)

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling

A stable high-humidity bubbler design to supply steam for solid oxide electrolysis cells

A stable steam supply is required for the operation of solid oxide electrolysis cells. Heated water bubblers are the most common method due to the simplicity and inherent safety of the method, however, several design challenges hinder effective implementation. Here, a stable and validated bubbler design is presented, capable of achieving very high steam concentrations, relatively high flow rates, and continuous operation. A piping and instrumentation diagram and bill of materials are provided to enable easy duplication. Critical design parameters are discussed, including safety considerations and materials requirements, which are applicable to any bubbler design. The practical implementation of bubblers is also presented, including methods to prevent condensation instability and reduce backpressure to achieve a stable steam supply. The 3″ x 6″ (7.6 cm × 15.2 cm) bubbler achieves up to 98% steam balance hydrogen at 200 sccm and up to 1 slpm at 96% steam.

08 - HYDROGEN

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Theory of the thermionic current beyond the traditional space charge limit enabled by trapped ions in the virtual cathode

We show that trapped ions in virtual cathode potential wells can raise the transmitted current of emitted electrons into a plasma much closer to the full emission than is predicted by cathode sheath theories without trapped ions. The transmitted current is controlled by the well barrier voltage, which must adjust to balance the creation of low-energy ions within the well, and their loss. Our model considers the case of a plasma-facing cathode where trapped ions are created passively via charge-exchange collisions and lost passively via thermal leakage over the well. We quantify these rates and estimate the current in terms of system parameters for thermionic emission into a plasma with several cathode geometries. A general prediction is that the current as a function of emitted flux does not saturate at the traditional space charge limit (the onset of a well) but can reach far higher values until the trapped ion balance breaks down, causing instability. The maximum stable current depends on parameters but in principle can be arbitrarily high if active techniques are used to manipulate the trapped ion balance. We conclude that major improvements in plasma technologies with hot cathodes might be achieved by optimizing the current enhancement enabled by trapped ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY