Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray beams & optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental investigations of elastohydrodynamic lubrication

Various experimental studies of elastohydrodynamic lubrication have been reviewed. The various types of machines used in these investigations, such as the disc, two and four ball, crossed-cylinders, and crossed-axes rolling disc machine, are described. The measurement of the most important parameters, such as film shape, film thickness, pressure, temperature, and traction, is considered. Determination of the film thickness is generally the most important of these effects since it dictates the extent to which the asperities on opposing surfaces can come into contact and thus has a direct bearing on wear and fatigue failure of the contacting surfaces. Several different techniques for measuring film thickness have been described, including electrical resistance, capacitance, X-ray, optical interferometry, laser beam diffraction, strain gage, and spring dynamometer methods. An attempt has been made to describe the basic concepts and limitations of each of these techniques. These various methods have been used by individual researchers, but there is no universally acceptable technique for measuring elastohydrodynamic film thickness. Capacitance methods have provided most of the reliable data for nominal line or rectangular conjunctions, but optical interferometry has proved to be the most effective procedure for elliptical contacts. Optical interferometry has the great advantage that it reveals not only the film thickness, but also details of the film shape over the complete area of the conjunction.

Hamrock, B. J.↗

Development study of the X-ray scattering properties of a group of optically polished flat samples

A group of twelve optically polished flat samples were used to study the scattering of X-rays. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering measurements were made at 8.34A and 0.92 deg angle of incidence. The results for ten of the samples are comparable, the two exceptions being the fire polished samples.

Froechtenigt, J. F.↗

X-ray scattering study

A soft X-ray glancing incidence telescope mirror and a group of twelve optical flat samples were used to study the scattering of X-rays. The mirror was made of Kanigen coated beryllium and the images produced were severely limited by scattering of X-rays. The best resolution attained was about fifteen arc seconds. The telescope efficiency was found to be 0.0006. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering then decreased with increasing angle of incidence until a critical angle was passed. At larger angles the scattering increased again. The samples all scattered more at 44 A than at 8 A. Metal samples were found to have about the same scattering at 44 A but greater scattering at 8 A than glass samples.

Wriston, R. S.↗

Summary of the workshop on active galaxies and quasars

The paper reports highlights of discussions carried out at the Tenth Texas Symposium on Relativistic Astrophysics concerning BL Lacertae objects and quasars and their relationship to active galactic nuclei. The discussions considered X-ray, optical and radio observations of active galaxies and quasars showing features which may be interpreted as jets or beams, and X-ray and VLBI observations of core-jet structures exhibiting apparent supraluminal expansion. Attention was also given to the properties of the energy source in the center of the active galaxies and quasars, the nature of quasar emission line regions, the production of the continuum in quasars and active galactic nuclei, and evidence for the association of quasars and BL Lac objects with galaxies.

Weistrop, D.↗

The room-temperature dissociation of the compound Au3Si

Three gold-18.6 at.% silicon specimens which were solidified by quenching from above the liquidus temperature have been reexamined after being stored at room temperature for about 8 years. It was found that the 'metastable' compound Au3Si formed on quenching had begun to dissociate by a surface nucleated, solid-state reaction. The reaction front had advanced about 0.2 mm from the surface, leaving a rim of dissociation products. These dissociation products were studied using optical and scanning electron microscopy, electron beam microprobe analysis and an X-ray micro-diffraction technique. It was concluded that the reaction produces elemental gold and silicon, as at higher reaction temperatures, but that the scale of dispersion is so extremely fine that the resulting microstructure cannot be resolved by scanning electron microscopy.

Bhattacharya, D.↗

The use of artificial electron beams as probes of the distant magnetosphere

Experiments are reported in which electron beams were injected into the magnetosphere (with up to 40 kev energy and at current up to 0.8 A) to diagnose the plasma processes at great distance by measurements made in the ionosphere. In some of the experiments, the conjugate region atmosphere was used to detect the electron beam; in others, conjugate echoes were detected near the injection region. The echoes were found to respond to changes in the convection fields and to reflect auroral zone activity. Theoretical and experimental echo patterns are discussed. Evidence for beam pitch angle scattering and altered mirror heights is presented. The use of the atmospheric response to electron beams in the loss cone as a detector has been achieved using optical, X-ray, and radar techniques.

Winckler, J. R.↗

Fabrication of X-ray telescopes for sounding rocket flights

Two X-ray telescopes and two detector systems were fabricated, and one of the telescopes (15 in. diameter, Wolter type I telescope) was flown on two sounding rocket flights. The telescopes were fabricated using the diamond point technique which provided the accurate figure of the mirrors to about a focal plane blur of 0.5 arc minutes. The 15 in. telescope mirrors were polished using standard polishing techniques to remove tooling marks from the diamond turning, then chemically polished to bring the X-ray reflectivity up to nearly the theoretical values. The optical image formed by the 15 in. telescope was found to produce a blur of about 40 arc seconds for a parallel beam of incoming laser light. The first flight of the telescope produced an X-ray image of Capella which indicated that the X-ray image was blurred to the extent of about 2 arc minutes. This additional image degradation was due to a slight error in focusing the X-ray image onto the detector.

Source record↗

Polar 5 - An electron accelerator experiment within an aurora. I - Instrumentation and geophysical conditions

A mother-daughter rocket was launched over two auroral structures, which included a 10 keV electron accelerator and a series of diagnostic instruments for monitoring optical and wave effects generated through beam-atmospheric interactions and production of secondary electrons. The instrumentation, the ground and rocket background measurements obtained, and some of the beam effects on various geophysical parameters are presented. Attention is given to the rocket geometry, capacitance probe, particle counters, photometers, and the bremsstrahlung X-ray detector. Observations on the plasma environment, auroral particle precipitation, d.c. electric field, optical emissions, and auroral background HF and VLF emissions are also discussed.

Maehlum, B. N.↗

Optics and lasers

Report describes twenty-seven optical concepts developed for holographic viewing, spectral transmission, and film camera technology. Articles include developments in laser-Doppler systems, laser beam deflection controls, X-ray photography, and camera components.

Source record↗

Studies of BL Lacertae objects with the Einstein X-ray observatory - The absolute volume density

It is estimated that the local volume density of BL Lac objects which emit greater than 10 to the 44th ergs/s in the 0.5-4.5 keV band is about 10 to the -7th/cu Mpc. This is based on identifications of bright X-ray sources, and the fact that Einstein X-ray observations detect BL Lac objects over a wide, continuous range of flux up to the thresholds of the all-sky X-ray surveys. Since this density is of the same order of magnitude as the local density of Seyfert galaxies, or local density of optically selected quasars, emitting X-rays at the same luminosity, we argue that the difference between these particular astronomical classifications is not solely due to the orientation of a relativistic beam.

Schwartz, D. A.↗

Laboratory degradation of Kapton in a low energy oxygen ion beam

An atomic oxygen ion beam, accelerated from a tunable microwave resonant cavity, was used at Lewis Research Center to bombard samples of the widely used polyimide Kapton. The Kapton experienced degradation and mass loss at high rates, which may be comparable to those found in Space Shuttle operations if the activation energy supplied by the beam enabled surface reactions with the ambient oxygen. The simulation reproduced the directionality (ram-wake dependence) of the degradiation, the change in optical properties of the degraded materials, and the structure seen in scanning electron micrographs of samples returned on the Shuttle Trails with a substituted argon ion beam produced no rapid degradation. Energy Dispersive X-ray Analysis (EDAX) showed significant surface composition changes in all bombarded samples. Mass loss rates and surface composition changes are discussed in terms of the possible oxidation chemistry of the interaction. Finally, the question of how the harmful degradation of materials in low earth orbit can be minimized is addressed.

Ferguson, D. C.↗

High resolution X-ray optics for astronomical and laboratory sources

In recent years X-ray telescopes have been used successfully for high resolution observations of astronomical objects, in particular the solar corona. At the present time X-ray microscopes are being developed for diagnostics of laser and electron beam induced fusion plasmas. This paper describes both types of imaging systems using as examples the AS&E X-ray telescope on Skylab and a 10X microscope being built for Los Alamos Scientific Laboratories. The designs, manufacturing tolerances, fabrication, testing, and performance are discussed. Steps for further development in both imaging areas are identified.

Silk, J. K.↗

Generation of a parallel X-ray beam and its use for testing collimators

A technique is described, by which a glass strip may be bent to match any curve of large radius of curvature, to a high degree of accuracy, so that it may be used as a glancing incidence X-ray or extreme ultraviolet optical element. The desired match is obtained by applying the optimum combination of end couples and by varying the cross-sectional moment of inertia along the length of the strip. A particular case, that of a parabola for use as a laboratory X-ray collimator, is considered in detail. The analysis predicts that a collimation of one or two arc seconds should be obtainable in practice, with simple and inexpensive apparatus. A prototype collimator to be used for the testing of space payloads using geometric (McGrath) collimators is described and laboratory results presented.

Underwood, J. H.↗

Reduction of the one-dimensional X-ray scattering data on mirror flats at NASA/Marshall Space Flight Center

Data on the scattering of X-rays from various mirror flats obtained from different vendors. The scattering data discussed in this section is obtained by a one dimensional proportional counter at X-ray energies of 8.06, 6.4 and 2.99 keV. X-rays are generated at one end of a 312.4m long tube which is under vacuum. This long tube provides a parallel beam of X-rays which is then collimated by a slit and allowed to scatter from a pair of mirror flats at small grazing angles of incidence. The slit and mirrors assembly is placed 182.4 meters from the other end of the tube where the proportional counter detector is located. The detector is sitting on an optical table which is pivoted so that it can rotate to intercept X-rays at a range of spatial locations. The optical table pivot is located 2.78 meters in front of the detector, and has an operational angular range of 350 arc minutes. Measured from the position of the mirror, this total angular range of the data is (350) (2.78/182.4) = 5.33 arcminutes.

Williams, A. C.↗

Focusing crystal polarimeter designed for X-ray polarimetry - Construction and performance

A method for the construction of a graphite crystal polarimeter designed for measuring linear polarization of X-ray continuum sources is described. The dependence of reflected intensity upon the polarization direction of the incident beam at Bragg angles of 45 deg is used to measure the polarization. The particular instrument described was designed for a satellite X-ray polarimeter. By using a focusing parabolic surface instead of a nonfocusing flat crystal, the signal-to-background ratio is improved by a factor of 30 as compared to a flat crystal polarimeter of the same effective area. The focusing properties of the reflector were tested both optically and with X-rays. The performance of the instrument as a polarimeter was tested with a continuum X-ray source of small polarization, which was independently measured by a single flat crystal polarimeter. The agreement between the two measurements is excellent, indicating that the instrument can measure polarizations as low as 0.3%.

Toraskar, J. R.↗

DKDP /potassium dideuterium phosphate/ light valves

The use of potassium dideuterium phosphate (DKDP) light valves for optical data processing is discussed. The operating principles and structure of optically and electron beam addressed DKDPs are compared, and specifications for both devices given. Optically addressed DKDPs are capable of higher resolution and contrast, but both systems represent viable real time spatial light modulators adaptable to optical processing. Examples of real time data processing performed by the DKDPs include: image addition and subtraction; reduction of noise introduced by scattered light in recording media; reconstruction of computer generated and acoustic holograms; reconstruction of synthetic aperture radar data; retrieval of three-dimensional information in X-ray diagnoses; radar signal processing and display; and optical pattern recognition and correlation of images, which has applications for missile guidance systems.

Casasent, D.↗

X-ray reflectometer for optical efficiency and scatter measurements

An instrument has been developed to determine the reflection efficiency and scatter characteristics of optical samples at X-ray wavelengths from 1.5 to 113 A. The reflectometer operates in an oil-free vacuum chamber and measures the reflection efficiency and scatter characteristics as a function of the angle of incidence. The reflection efficiency is given for 8.34-A radiation incident on a fused silica sample finished to a flatness of one-tenth of a wavelength. The experimental reflection efficiency is compared with the theoretical data. The scatter curves are given for the direct X-ray beam and for the beam reflected from the fused silica sample at an angle of incidence of 50 arcmin. The full-width-at-half-maximum (FWHM) resolution of the instrument is approximately 13 arcsec, as determined by a least-squares smoothing of the experimental data.

Reynolds, J. M.↗

Inversion of the resonance line of Sr/+/ produced by optically pumping Sr atoms

A description is presented of an experiment which demonstrates the selective production of excited-state ions by an optical absorption from neutrals. An inversion on the resonance line of Sr(+) was produced by laser excitation of a two-electron transition, followed by ionization of one of the excited electrons by the same laser. A pulsed, mode-locked laser operating at 2680 A was used to excite atoms from the Sr ground level. The same laser then ionized the excited atoms. The 2680-A pump beam was generated by frequency doubling the output of a synchronously pumped mode-locked dye laser in a KDP crystal. It is pointed out that the reported results are significant for the construction of vacuum-ultraviolet and X-ray lasers. Many of the proposed methods for making such lasers depend on the selective production of excited-state ions.

Green, W. R.↗