Surface accuracy measurement sensor test on a 50-meter antenna surface model

The Surface Accuracy Measurement Sensor (SAMS) is a telescope with a focal plane photo electric detector that senses the lateral position of light source targets in its field of view. After extensive laboratory testing the engineering breadboard sensor system was installed and tested on a 30 degree segment of a 50-meter diameter, mesh surface, antenna model. Test results correlated well with the laboratory tests and indicated accuracies of approximately 0.59 arc seconds at 21 meters range. Test results are presented and recommendations given for sensor improvements.

Spiers, R. B.

Test-Bed Aircraft Scanner

Test-bed aircraft multispectral scanner (TBAMS) is line-scanning multispectral imaging system with eight visible/near-infrared channels and one thermal-infrared channel. Key design features of TBAMS are its large size and modular subsystem mounted on horizontal baseplate. This unique layout allows easy access to and replacement of subsystems and their subcomponents. System designed around existing inexpensive parts, sacrifices compactness for ease of modification.

Jobson, D. J.

Radiometric performance of the test-bed aircraft multispectral scanner /TBAMS/ system

Laboratory and flight radiometric performance testing of an experimental multispectral scanner system is described. High sensitivity performance is confirmed by test results using noise equivalent spectral radiance as the primary figure of merit. A performance comparison between the test-bed aircraft multispectral scanner (TBAMS) and the Bendix modular multispectral scanner (M2S) is presented. Methods for achieving high sensitivity operation are discussed as well as some of the practical implications of such operation for flight remote sensing experiments.

Jobson, D. J.

Analytical models and system topologies for remote multispectral data acquisition and classification

Simple analytical models are presented of the radiometric and statistical processes that are involved in multispectral data acquisition and classification. Also presented are basic system topologies which combine remote sensing with data classification. These models and topologies offer a preliminary but systematic step towards the use of computer simulations to analyze remote multispectral data acquisition and classification systems.

Huck, F. O.

Quasi-microscope concept for planetary missions - Stereo

The quasi-microscope has been used for stereo pictures using a small aperture placed at the right and left over the entrance aperture. A 16-degree stereo view angle yields an enhanced stereo effect. When viewed upward through a transparent support, all grains come into focus. The technique may be used for determining mineral constituents on the basis of cleavage and fracture patterns, grain details, and surface slopes used in estimating single-particle albedo and the illumination of scattering profiles.

Burcher, E. E.

Device for measuring the contour of a surface

Light from a source is imaged by a lens onto a surface so that the energy from the source is concentrated into a spot. As the spot across the surface is scanned, the surface moves relative to the point of perfect focus. When the surface moves away from perfect focus the spot increases in size, while the total energy in the spot remains virtually constant. The lens then reimages the light reflected by the surface onto two detectors through two different sized apertures. The light energy going to the two detectors is separated by a beam splitter. This second path of the light energy through the lens further defocuses the spot, but as a result of the different sizes of the apertures in each light detector path, the amount of defocus for each is different. The ratio of the outputs of the two detectors which are indicative of the contour of the surface is obtained by a divider.

Burcher, E. E.

Transmitting and reflecting diffuser

An ultraviolet grade fused silica substrate is coated with vaporized fused silica. The coating thickness is controlled, one thickness causing ultraviolet light to diffuse and another thickness causing ultraviolet light to reflect a near Lambertian pattern.

Keafer, L. S., Jr.

An optical profilometer for spatial characterization of three-dimensional surfaces

The design concept and system operation of an optical profilometer are discussed, and a preliminary evaluation of a breadboard system is presented to demonstrate the feasibility of the optical profilometer technique. Measurement results are presented for several test surfaces; and to illustrate a typical application, results are shown for a cleft palate cast used by dental surgeons. Finally, recommendations are made for future development of the optical profilometer technique for specific engineering or scientific applications.

Kelly, W. L., IV

Quasi-microscope concept for planetary missions

Viking lander cameras have returned stereo and multispectral views of the Martian surface with a resolution that approaches 2 mm/lp in the near field. A two-orders-of-magnitude increase in resolution could be obtained for collected surface samples by augmenting these cameras with auxiliary optics that would neither impose special camera design requirements nor limit the cameras field of view of the terrain. Quasi-microscope images would provide valuable data on the physical and chemical characteristics of planetary regoliths.

Huck, F. O.

Performance evaluation of a quasi-microscope for planetary landers

Spatial resolutions achieved with cameras on lunar and planetary landers have been limited to about 1 mm, whereas microscopes of the type proposed for such landers could have obtained resolutions of about 1 um but were never accepted because of their complexity and weight. The quasi-microscope evaluated in this paper could provide intermediate resolutions of about 10 um with relatively simple optics that would augment a camera, such as the Viking lander camera, without imposing special design requirements on the camera of limiting its field of view of the terrain. Images of natural particulate samples taken in black and white and in color show that grain size, shape, and texture are made visible for unconsolidated materials in a 50- to 500-um size range. Such information may provide broad outlines of planetary surface mineralogy and allow inferences to be made of grain origin and evolution. The mineralogical descriptions of single grains would be aided by the reflectance spectra that could, for example, be estimated from the six-channel multispectral data of the Viking lander camera.

Burcher, E. E.

Optical profilometer

Device, consisting of optical scanning subsystem, two light detectors with associated amolifiers, analog divider, and adjustable nonlinear function generator, directly determines surface area, absolute depth, and point-to-point distance of three-dimensional object without physical contact with surface under observation.

Burcher, E. E.

Prediction of Viking lander camera image quality

Formulations are presented that permit prediction of image quality as a function of camera performance, surface radiance properties, and lighting and viewing geometry. Predictions made for a wide range of surface radiance properties reveal that image quality depends strongly on proper camera dynamic range command and on favorable lighting and viewing geometry. Proper camera dynamic range commands depend mostly on the surface albedo that will be encountered. Favorable lighting and viewing geometries depend mostly on lander orientation with respect to the diurnal sun path over the landing site, and tend to be independent of surface albedo and illumination scattering function. Side lighting with low sun elevation angles (10 to 30 deg) is generally favorable for imaging spatial details and slopes, whereas high sun elevation angles are favorable for measuring spectral reflectances.

Huck, F. O.

Reflectance characteristics of the Viking lander camera reference test charts

Reference test charts provide radiometric, colorimetric, and spatial resolution references for the Viking lander cameras on Mars. Reflectance measurements of these references are described, including the absolute bidirectional reflectance of the radiometric references and the relative spectral reflectance of both radiometric and colorimetric references. Results show that the bidirection reflectance of the radiometric references is Lambertian to within + or - 7% for incidence angles between 20 deg and 60 deg, and that their spectral reflectance is constant with wavelength to within + or - 5% over the spectral range of the cameras. Estimated accuracy of the measurements is + or - 0.05 in relative spectral reflectance.

Wall, S. D.

Radiometric performance of the Viking Mars lander cameras

The Viking lander cameras feature an array of 12 silicon photodiodes for electronic focus selection and multispectral imaging. Comparisons of absolute radiometric calibrations of the four cameras selected for the mission to Mars with performance predictions based on their design data revealed minor discrepancies. These discrepancies were caused primarily by the method used to calibrate the photosensor array and apparently also from light reflections internal to the array. The sensitivity and dynamic range of all camera channels are found to be sufficient for high quality pictures, providing that the commandable gains and offsets can be optimized for the scene radiance; otherwise, the quantization noise may be too high or the dynamic range too low for an adequate characterization of the scene.

Huck, F. O.

Spectrometer integrated with a facsimile camera

This invention integrates a spectrometer capability with the basic imagery function of facsimile cameras without significantly increasing mechanical or optical complexity, or interfering with the imaging function. The invention consists of a group of photodetectors arranged in a linear array in the focal plane of the facsimile camera with a separate narrow band interference filter centered over each photodetector. The interference filter photodetector array is on a line in the focal plane of the facsimile camera along the direction of image motion due to the rotation of the facsimile camera's vertical mirror. As the image of the picture element of interest travels down the interference filter photodetector array, the photodetector outputs are synchronously selected and sampled to provide spectral information on the single picture element.

Burcher, E. E.

Automatic focus control for facsimile cameras

An electronic circuit for controlling the focus of facsimile cameras is described. The circuit consists of balanced a.c. amplifiers, two square law function generators, and a differential amplifier and power drive. The invention includes a method for maintaining the imaging sensor at the expected location of the focal plane as the facsimile camera scans a scene or terrain. A block diagram of the electronic circuitry is provided.

Sinclair, A. R.

Viewgraph preparation made easier

Rolls of color-reversal film permit exposure of over 200 viewgraphs on one film loading. Time is saved in film development as roll film lends itself readily to automatic processing.

Broskie, H. W.

An investigation of the facsimile camera response to object motion

A general analytical model of the facsimile camera response to object motion is derived as an initial step toward characterizing the resulting image degradation. This model expresses the spatial convolution of a time-varying object radiance distribution and camera point-spread function for each picture element in the image. Time variations and these two functions during each convolution account for blurring of small image detail, and variations between, as well as during, successive convolutions account for geometric image distortions. If the object moves beyond the angular extent of several picture elements while it is being imaged, then geometric distortion tends to dominate blurring as the primary cause of image degradation. The extent of distortion depends not only on object size and velocity but also on the direction of object motion, and is therefore difficult to classify in a general sense.

Huck, F. O.