Search NASASearch

Engineering topics

Content, David

Publications and source records attributed to Content, David.

29 records · Page 2

The Constellation-X Spectroscopy X-Ray Telescope

The status of technology development for the Constellation-X Spectroscopy X-ray Telescope (SXT) mirror is presented. The SXT mirror combines a large (1.6 m) aperture with modest (12 arc sec half power diameter) angular resolution and low mass (750 kg). The overall collecting area, larger than 9,600 square cm at 0.25 keV, requires high throughput, and thus nesting of a substantial number of thin reflectors. A phased development program is underway to develop reflectors, mounting and alignment approaches, and metrology techniques for components and the mirror has a whole. The latest results in all these areas are summarized, along with an overview of results of optical testing of reflector performance.

Petre, Robert

Optical Metrology for the Segmented Optics on the Constellation-X Spectroscopy X-Ray Telescope

We present the metrology requirements and metrology implementation necessary to prove out the reflector technology for the Constellation X(C-X) spectroscopy X-ray telescope (SXT). This segmented, 1.6m diameter highly nested Wolter-1 telescope presents many metrology and alignment challenges. In particular, these mirrors have a stringent imaging error budget as compared to their intrinsic stiffness; This is required for Constellation-X to have sufficient effective area with the weight requirement. This has implications for the metrology that can be used. A variety of contract and noncontact optical profiling and interferometric methods are combined to test the formed glass substrates before replication and the replicated reflector segments.The reflectors are tested both stand-alone and in-situ in an alignment tower.Some of these methods have not been used on prior X-ray telescopes and some are feasible only because of the segmented approach used on the SXT. Methods discussed include high precision coordinate measurement machines using very low force or optical probe axial interferometric profiling azimuthal circularity profiling and use of advanced null optics such as conical computer generated hologram (CGHs).

Content, David

Development of Mirror Segments for the Constellation-X Observatory

As NASA's next major X-ray observatory, Constellation-X will have a photon collection area of 30,000 sq cm at 1 keV, which, after folding other instrumental responses, translates into an effective area of 15,000 sq cm. The observatory consists of four identical satellites each of which carries a spectroscopic X-ray telescope mirror assembly (SXT) that is 1.6 m in diameter and has a focal length of 10 m and a collection area of 7,500 sq cm at 1 keV and an angular resolution of 15 sec. HPD (half-power diameter) at the system level. Each mirror assembly consists of a large number of mirror segments precisely assembled together. Our development of the mirror segments is divided into two steps. The first one is to develop the basic approach and fabricate segments within the constraints of existing infrastructure to meet the angular resolution requirement, but not mirror segment size requirement. We have all but successfully completed this part of the development. We are now on the verge of going into the second step, that is to fabricate mirror segments of larger sizes to reduce the number of segments that have to be aligned and integrated. In this paper, we report on the requirements and the development status of the mirror segments. These assembly and other requirements of the SXT are reported elsewhere.

Zhang, W.

Automated Figuring and Polishing of Replication Mandrels for X-Ray Telescopes

In support of the Constellation X mission the Optics Branch at Goddard Space Flight Center is developing technology for precision figuring and polishing of mandrels used to produce replicated mirrors that will be used in X-Ray telescopes. Employing a specially built machine controlled in 2 axes by a computer, we are doing automated polishing/figuring of 15 cm long, 20 cm diameter cylindrical, conical and Wolter mandrels. A battery of tests allow us to fully characterize all important aspects of the mandrels, including surface figure and finish, mid-frequency errors, diameters and cone angle. Parts are currently being produced with surface roughnesses at the .5nm RMS level, and half-power diameter slope error less than 2 arcseconds.

Krebs, Carolyn

X-Ray Testing Constellation-X Optics at MSFC's 100-m Facility

In addition to the 530-m-long X-Ray Calibration Facility (XRCF), NASA's Marshall Space Flight Center (MSFC) operates a 104-m-long (source-to-detector) X-ray-test facility. Originally developed and still occasionally used for stray-light testing of visible-fight optical systems, the so-called "Stray-Light Facility" now serves primarily as a convenient and inexpensive facility for performance evaluation and calibration of X-ray optics and detectors. The facility can accommodate X-ray optics up to about 1-m diameter and 12-m focal length. Currently available electron-impact sources at the facility span the approximate energy range 0.2 to 100 keV, thus supporting testing of soft- and hard-X-ray optics and detectors. Available MSFC detectors are a front-illuminated CCD (charge-coupled device) and a scanning CZT (cadmium--zinc--telluride) detector, with low-energy cut-offs of about 0.8 and 3 keV, respectively. In order to test developmental optics for the Constellation-X Project, led by NASA's Goddard Space Flight Center (GSFC), MSFC undertook several enhancements to the facility. Foremost among these was development and fabrication of a five-degree-of-freedom (5-DoF) optics mount and control system, which translates and tilts the user-provided mirror assembly suspended from its interface plate. Initial Constellation-X tests characterize the performance of the Optical Alignment Pathfinder Two (OAP2) for the large Spectroscopy X-ray Telescope (SXT) and of demonstration mirror assemblies for the Hard X-ray Telescope (HXT). With the Centroid Detector Assembly (CDA), used for precision alignment of the Chandra (nee AXAF) mirrors, the Constellation-X SXT Team optically aligned the individual mirrors of the OAPZ at GSFC. The team then developed set-up and alignment procedures, including transfer of the alignment from the optical alignment facility at GSFC to the X-ray test facility at MSFC, using a reference flat and fiducials. The OAPZ incorporates additional ancillary features --- fixed aperture mask and movable sub-aperture mask --- to facilitate X-ray characterization of the optics. Although the OAPZ was designed to- have low sensitivity to temperature offsets and gradients, analyses showed the necessity of active temperature control for the X-ray performance testing. Thus, the Smithsonian Astrophysical Observatory (SAO) implemented a thermal control and monitoring system, designed to hold the OAP2 close to its assembly.

O'Dell, Stephen

Constellation-X Cylinder Figuring and Polishing Studies

In support of Goddard's Constellation-X mandrel manufacturing effort a series of fabrication experiments are being performed to determine a best approach. Currently, polishing immediately after diamond turning, produces a RMS surface roughness of 0.31 nm, on a nickel plated aluminum mandrel. Studies currently under way will incorporate an abrasive figuring step followed by a polishing operation. The current diamond turning, figuring and polishing procedures will be described and the results presented.

Waluschka, Eugene

Metrology and Alignment of Light Weight Grazing Incidence X-Ray Mirrors

Metrology and alignment of light weight X-ray optics have been a challenge for two reasons: (1) that the intrinsic mirror quality and distortions caused by handling can not be easily separated, and (2) the diffraction limits of the visible light become a severe problem at the order of one arc-minute. Traditional methods of using a normal incident pencil or small parallel beam which monitors a tiny fraction of the mirror in question at a given time can not adequately monitor those distortions. We are developing a normal incidence setup that monitors a large fraction, if not the whole, of the mirror at any given time. It will allow us to align thin X-ray mirrors to-an accuracy of a few arc seconds or to a limit dominated by the mirror intrinsic quality.

Zhang, William

Diffraction Grating Efficiency Calculations Based on Real Groove Profiles

The program we are attempting to bring about combines 3 difficult features, in order to demonstrate accuracy of efficiency predictions: (1) Accurate groove metrology methods on surface relief gratings; (2) Rigorous and usable electromagnetic efficiency calculation codes; (3) Accurate efficiency measurements in polarized light The benefit would be an increase in yield for high-performance gratings. Many such applications suffer long lead time or serious performance loss when new gratings are made which do not meet requirements or expectations.

Content, David

Deformed ellipsoidal gratings for far-ultraviolet spectrographs - Analytic optimization

Analytic formulas are developed for the semiaxes and for the deformation coefficients of a deformed ellipsoidal grating that minimize aberrations over a given spectral range. These include the Rowland circle mount and quasi-Rowland circle mounts, as required for systems that combine spectra from multiple gratings on a common detector. It is also shown that the necessary condition for a holographic grating to give a better performance over a conventional grating is the use of a convergent beam and a divergent beam for the recording. Examples applicable to the Far-Ultraviolet Spectroscopic Explorer are given. The light-path function for a deformed ellipsoidal holographic grating is also presented.

Content, David

Aberration-corrected aspheric grating designs for the Lyman/Far-Ultraviolet Spectroscopic Explorer high-resolution spectrograph - A comparison

Two approaches to reducing the optical aberrations of concave diffraction gratings have been studied to obtain candidate grating designs for the Lyman/Far-Ultraviolet Spectroscopic Explorer mission. The first approach involves shaping the grating substrate while using straight and equally spaced grooves. The second approach involves using a gating substrate with a relatively simple figure and holographically controlling the groove curvature and spacing. Specific designs derived from both approaches are analyzed and compared.

Trout, Catherine

Aberration corrected aspheric grating for far ultraviolet spectrographs - Conventional approach

Two approaches to reducing optical aberrations of concave grating spectrographs have been used, holographically controlling the groove curvature and spacing and reshaping the optical substrate while ruling the grooves conventionally. The latter approach, slightly deforming an ellipsoidal grating blank, can lead to diffraction-limited performance at a single FUV wavelength. When such a grating is used in a slitted Rowland circle spectrograph, the result is an extremely efficient spectrograph with spectral resolving power of about 30,000 and low astigmatism. Optical fabrication technology has advanced to the point where these exotic surface gratings are becoming practical.

Content, David