Criticality of Low-Energy Protons in Single-Event Effects Testing of Highly-Scaled Technologies

We report low-energy proton and low-energy alpha particle single-event effects (SEE) data on a 32 nm silicon-on-insulator (SOI) complementary metal oxide semiconductor (CMOS) latches and static random access memory (SRAM) that demonstrates the criticality of using low-energy protons for SEE testing of highly-scaled technologies. Low-energy protons produced a significantly higher fraction of multi-bit upsets relative to single-bit upsets when compared to similar alpha particle data. This difference highlights the importance of performing hardness assurance testing with protons that include energy distribution components below 2 megaelectron-volt. The importance of low-energy protons to system-level single-event performance is based on the technology under investigation as well as the target radiation environment.

random access memory↗

Impact of Spacecraft Shielding on Direct Ionization Soft Error Rates for Sub-130 nm Technologies

We use ray tracing software to model various levels of spacecraft shielding complexity and energy deposition pulse height analysis to study how it affects the direct ionization soft error rate of microelectronic components in space. The analysis incorporates the galactic cosmic ray background, trapped proton, and solar heavy ion environments as well as the October 1989 and July 2000 solar particle events.

Pellish, Jonathan A.↗

Impact of Spacecraft Shielding on Direct Ionization Soft Error Rates for sub-130 nm Technologies

We use ray tracing software to model various levels of spacecraft shielding complexity and energy deposition pulse height analysis to study how it affects the direct ionization soft error rate of microelectronic components in space. The analysis incorporates the galactic cosmic ray background, trapped proton, and solar heavy ion environments as well as the October 1989 and July 2000 solar particle events.

Pellish, Jonathan A.↗

Heavy Ion Testing at the Galactic Cosmic Ray Energy Peak

A 1 GeV/u 5 6Fe ion beam allows for true 90deg tilt irradiations of various microelectronic c-0mponents and reveals relevant upset trends at the GCR Hux energy peak. Three SRAMs and an SRAM-based FPGA evaluated at the NASA Space Radiation Effects Laboratory demonstrate that a 90deg tilt irradiation yields a unique device response. These tilt angle effects need t-0 be screened for, and if found, pursued with radiation transport simulations to quantify their impact on event rate calculations.

Pellish, Jonathan A.↗

Heavy Ion Microbeam and Broadbeam Transients in SiGe HBTs

SiGe HBT heavy ion current transients are measured using microbeam and both high- and low-energy broadbeam sources. These new data provide detailed insight into the effects of ion range, LET, and strike location.

Pellish, Jonathan A.↗

Low-Energy Proton Testing Methodology

Use of low-energy protons and high-energy light ions is becoming necessary to investigate current-generation SEU thresholds. Systematic errors can dominate measurements made with low-energy protons. Range and energy straggling contribute to systematic error. Low-energy proton testing is not a step-and-repeat process. Low-energy protons and high-energy light ions can be used to measure SEU cross section of single sensitive features; important for simulation.

Pellish, Jonathan A.↗

Heavy Ion Current Transients in SiGe HBTs

Time-resolved ion beam induced charge reveals heavy ion response of IBM 5AM SiGe HBT: a) Position correlation[ b) Unique response for different bias schemes; c) Similarities to TPA pulsed-laser data. Heavy ion broad-beam transients provide more realistic device response: a) Feedback using microbeam data; b) Overcome issues of LET and ion range with microbeam. Both micro- and broad-beam data sets yield valuable input for TCAD simulations. Uncover detailed mechanisms for SiGe HBTs and other devices fabricated on lightly-doped substrates.

Pellish, Jonathan A.↗

Heavy Ion Microbeam- and Broadbeam-Induced Transients in SiGe HBTs

SiGe HBT heavy ion-induced current transients are measured using Sandia National Laboratories microbeam and high- and low-energy broadbeam sources at the Grand Accelerateur National d'Ions Lourds and the University of Jyvaskyla. The data were captured using a custom broadband IC package and real-time digital phosphor oscilloscopes with at least 16 GHz of analog bandwidth. These data provide detailed insight into the effects of ion strike location, range, and LET.

Pellish, Jonathan A.↗

Phillips SA8016BW 2.5 GHz Synthesizer SEE Testing

This viewgraph presentation reviews the Single Event Effects (SEE) testing of the Phillips SA8016BW 2.5 GHz Synthesizer that was chose by the GLAST Program for Frequency Generation. Included in this are diagrams of the phased-locked loop (PLL), the synthesizer, and heater.

Carts, Marty↗

Measurement and Simulation of the Variation in Proton-Induced Energy Deposition in Large Silicon Diode Arrays

The proton induced charge deposition in a well characterized silicon P-i-N focal plane array is analyzed with Monte Carlo based simulations. These simulations include all physical processes, together with pile up, to accurately describe the experimental data. Simulation results reveal important high energy events not easily detected through experiment due to low statistics. The effects of each physical mechanism on the device response is shown for a single proton energy as well as a full proton space flux.

Howe, Christina L.↗

Lateral Diffusion Length Changes in HgCdTe Detectors in a Proton Environment

This paper presents a study of the performance degradation in a proton environment of very long wavelength infrared (VLWIR) HgCdTe detectors. The energy dependence of the Non-Ionizing Energy Loss (NIEL) in HgCdTe provides a framework for estimating the responsivity degradation in VLWIR HgCdTe due to on orbit exposure from protons. Banded detector arrays that have different detector designs were irradiated at proton energies of 7, 12, and 63 MeV. These banded detector arrays allo~vedin sight into how the fundamental detector parameters degraded in a proton environment at the three different proton energies. Measured data demonstrated that the detector responsivity degradation at 7 MeV is 5 times larger than the degradation at 63 MeV. The comparison of the responsivity degradation at the different proton energies suggests that the atomic Columbic interaction of the protons with the HgCdTe detector is likely the primary mechanism responsible for the degradation in responsivity at proton energies below 30 MeV.

Hubbs, John E.↗

Recent Results on SEU Hardening of SiGe HBT Logic Circuits

A viewgraph presentation on SEU tolerant SiGe HBT technology is shown. The topics include: 1) Introduction; 2) TID and SEU in SiGe Technology; 3) RHBD Techniques; 4) Experiment; 5) Heavy-Ion Data and Analysis; and 6) Summary.