Search NASA⌕ Search

Engineering topics

Parsons-Davis, Tashi

Publications and source records attributed to Parsons-Davis, Tashi.

At least 19 records

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of NBL PO plutonium isotopic standards CRM 136A, CRM 137A, and CRM 138A

Lawrence Livermore National Laboratory (LLNL) produced approximately 1 mg units of purified Pu from the parent New Brunswick Laboratory (NBL) certified reference materials (CRM) 137, 136 and 138 isotopic standards for the NBL Program Office (NBL PO) as detailed in the revised project plan. As stated in the plan, three representative units of each material were dispensed at the same time to be characterized at LLNL and provide informational values for the quantity of Pu and progeny nuclides in each unit. NBL PO intends to collect and evaluate isotopic measurement data from multiple laboratories and certify these materials as new isotopic standards C137A, C136A, and C138A, respectively. Soon after production eleven units of each analytical standard were shipped to other analytical laboratories for the certification effort, and 121, 119, and 119 units of C137A, C136A and C138A, respectively were shipped to Mickey Finch at Y12 NBL distribution center in November 2024 (30-gallon drum, TID 003777 PRL 7000005043). Residual purified Pu from the effort is being stored indefinitely in B332 at LLNL. Detailed methods can be found in the production plan, and this report describes and documents aspects of the production effort that are not in or were modified from the original production plan.

and nuclear chemistry↗

Electrophoretic deposition for improved trace element homogeneity in silica reference materials

Spatially-resolved analysis requires homogeneous reference materials (RMs) to make reliable quantitative measurements. Here we previously developed an electrophoretic deposition (EPD) method for fabrication of glassy microanalytical RMs with superior platinum-group element homogeneity **[1], and now include further dopants. For 39 trace elements, we analyzed dopant homogeneity in sintered silica (SiO 2 ) samples consolidated either mechanically by die-pressing (DP) or by EPD. A set of EPD and DP samples was made from each of two nanoparticle feedstocks produced by variations of the Stöber process **[2]. Spatially-resolved dopant distribution was characterized in all samples by laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS). In both sample sets, homogeneity of most trace elements was substantially improved by EPD relative to their DP counterpart.

36 MATERIALS SCIENCE↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modular, disposable 3D printed microfluidic membrane system for separation and purification

The present disclosure relates to a membrane extraction apparatus for extracting a component from a first liquid. The apparatus may incorporate a housing comprised of first and second mating housing halves, with each housing half having an open faced channel formed therein such that the channels at least partially overlay one another when the two housing halves are secured together. A membrane filter is disposed between the two housing halves to overlay the open faced channels. The membrane filter extracts the component from the first liquid and transfers the component into the second liquid as the first and second liquids flow through the first and second housing halves.

Servis, Anna G.↗

Laser Driven Hydrothermal Processing (LDHP) for Rapid Dissolution of Glassy Nuclear Debris

Discovered in 2009 on the SLAB laser system at LLNL, Laser-Driven Hydrothermal Processing (LDHP) both spalls and transiently dissolves a wetted surface (e.g., rock, concrete, paint) when that surface is struck by a laser beam pulse under specific conditions. Previous projects have explored the application of LDHP to expediting sample dissolution for post-detonation nuclear forensics. Early results were very promising, indicating that this method could decrease material dissolution time by a factor of 10 or more. However, the large and complicated lasers previously used are impractical for this application. Under the R^3 venture we aimed to benchmark the LDHP capabilities of turn-key commercial off-the-shelf (COTS) lasers, and to establish how this process could be integrated into an analytical workflow for nuclear forensic analysis. We demonstrated that geological rock standards could be quickly processed into fine powder by LDHP followed by complete acid digestion in 15 minutes, without elemental fractionation that would skew analytical results. We determined that the COTS laser can be used for LDHP that could potentially reduce dissolution time for solid nuclear debris samples in post detonation nuclear forensics. One downside to this approach, however, is that the laser interactions are different with every material, so extensive method validation would be required for all likely material compositions. The LDHP processing rates of several materials were tested and determined to be favorable in the beginning with significant slowdown due to particulate scattering. This could be mitigated either by stopping and centrifuging the sample at specific intervals, or through design of a continuous solvent flow through mechanism.

36 MATERIALS SCIENCE↗

New NBL Pu Isotopic Standards C137A and C136A as Working Reference Materials for Radiochronometry in Nuclear Forensics

Lawrence Livermore National Laboratory (LLNL) and the NBL Program Office (NBL PO) are collaborating on production of purified sub-units of the former NBS 936, 937 and 938 plutonium isotopic reference materials, which will be certified for plutonium isotopic composition and sold as certified reference materials (CRMs) C136A, C137A, and C138A, respectively. These reference materials are used throughout the United States and international community as standards for isotopic measurement method calibration and quality control and were first produced over 50 years ago. To reduce quantities of in-grown daughter products and potentially enable their use as Pu radiochronometry reference materials, the materials undergo a two-stage anion exchange purification to significantly reduce the quantities of U, Am, and Np in the source material. The purified Pu is aliquoted into ~1 mg units in the nitrate form, which will facilitate easier shipping and use compared to the 0.25 g parent units. The production process has been completed for the high- and medium- burnup isotopic standards C137A and C136A and will soon be performed for the weapons-grade Pu standard C138A. This report describes the measurement of trace actinide progeny of the Pu isotopes ( 234 U, 235 U, 236U, 241 Am and 237 Np) in purified C137A and 136A isotopic standards to provide informational values and assess the possibility of their use as working reference materials for radiochronometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid-phase isotope harvesting of 88 Zr from a radioactive ion beam facility

During routine operation of the Facility for Rare Isotope Beams (FRIB), radionuclides will accumulate in both the aqueous beam dump and along the beamline in the process of beam purification. These byproduct radionuclides, many of which are far from stability, can be collected and purified for use in other scientific applications in a process called isotope harvesting. In this work, the viability of 88 Zr harvesting from solid components was investigated at the National Superconducting Cyclotron Laboratory. A secondary 88 Zr beam was stopped in a series of collectors comprised of Al, Cu, W, and Au foils. Here, this work details irradiation of the collector foils and the subsequent radiochemical processing to isolate the deposited 88 Zr (and its daughter 88 Y) from them. Total average recovery from the Al, Cu, and Au collector foils was (91.3 ± 8.9) % for 88 Zr and (95.0 ± 5.8) % for 88 Y, respectively, which is over three times higher recovery than in a previous aqueous-phase harvesting experiment. The utility of solid-phase isotope harvesting to access elements such as Zr that readily hydrolyze in near-neutral pH aqueous conditions has been demonstrated for application to harvesting from solid components at FRIB.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Forensics

Nuclear forensics is a key part of the nuclear security strategy for the United States and the international community. The NACS Division is central to the leadership role that LLNL has had in nuclear forensics over the past 25 years. Our current nuclear forensic program includes conducting R&D on provenance and attribution signatures, collaborating with international partners, training the next generation of nuclear forensic experts, developing test materials for verification and validation exercises, and providing expert advice to national and international policy makers. Key to our success in these areas has been the strong and continuing involvement in nuclear forensic casework obtained through law enforcement and intelligence channels as well as our outstanding analytical capabilities. NACS must continue to conduct forward-thinking R&D in nuclear forensics that supports operational programs and addresses intelligence gaps. To maintain leadership in nuclear forensics, we must attract, develop, and retain the best talent. The NNSA has a central leadership role in developing educational initiatives for nuclear forensics. In concert with the Glenn T. Seaborg Institute, the NACS Division will continue to participate in all nuclear forensic educational initiatives (undergraduate, graduate, postdoctoral) and incorporate LLNL’s D&I vision into its student and postdoc recruitment efforts. We will continue to build formal relationships with key academic partners and institutions with active and emerging nuclear forensic research interests. We will also strengthen relationships with NNSA DNN and SSAA funded university consortia (e.g. NSSC, ACE, CNEC, CVT, ETI, MTV), helping them conduct research of interest and relevance to nuclear forensics, while at the same time evaluating and recruiting promising talent from these programs.

07 ISOTOPE AND RADIATION SOURCES↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Transport Modeling of Kinetically Limited Microscale Extraction Systems: Droplet and Supported Liquid Membrane Separations

Microfluidic droplet extraction devices can be used to efficiently measure solute phase transfer kinetics in liquid–liquid extraction systems. In this work, a droplet extraction apparatus was constructed using off-the-shelf and custom 3D printed parts for less than 110 USD. The interfacial kinetics of the transfer of Pu(IV) between an aqueous nitric acid phase and a 5 v/v% tridodecylamine (TDA) in toluene phase were characterized by determining the extent of Pu(IV) transfer between phases at different flow rates. Forward interfacial rate constants calculated from this data using an analytical model are 5.6 × 10 –3 mm s –1 under extraction (aqueous-to-organic solute transfer) conditions and 3.3 × 10 –3 mm s –1 under stripping (organic-to-aqueous solute transfer) conditions. The analytical model is valid when the rate of solute transfer across the interface between the two liquid phases has pseudo-first-order reversible reaction kinetics and is slow relative to the rate of solute transport to the interface. The change in the outlet concentration with residence time determined using the analytical model was compared with the results of a numerical model accounting for advection/diffusion to the interface in addition to kinetically limited interfacial solute transfer. These calculations revealed that for systems with forward interfacial rate constants greater than approximately 10 –2 mm s –1 , the analytical model must be supplemented with a numerical transport model accounting for an additional advection/diffusion mass transfer resistance. This threshold corresponds to a Damköhler number of one. The measured interfacial kinetic rate constants for Pu(IV)/TDA were used in a supported liquid membrane (SLM) numerical model, which showed that the Pu(IV) phase transfer kinetics are fast enough for use in a practical separation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

3D Printed Microfluidic Supported Liquid Membrane Module for Radionuclide Separations

Microfluidic supported liquid membrane extraction is a promising technique for microliter-scale radionuclide separations because it requires very small reagent volumes and combines extraction and stripping in a single unit operation. Flat sheet supported liquid membrane (FS-SLM) modules with 100, 200, 300, and 400 μm deep channels were fabricated at a cost of less than 5 USD in material using a commercially available resin three-dimensional (3D) printer. The performance of these modules was characterized by quantifying uranium transport across a 15 v/v% tributyl phosphate (TBP) liquid membrane at flow rates between 5 and 60 μL min –1 and developing a two-dimensional (2D) numerical transport model for the system. The extent of uranium extraction was found to increase with increasing residence time and decreasing channel depth, with quantitative extraction occurring at the slowest flow rates and shallowest channel depths. The numerical model agreed well with the experimental extraction results. Time-dependent calculations showed that the modules reach steady state in fewer than 9 min and that there is a considerable buildup of uranium in the membrane during that time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Uncovering Uranium Isotopic Heterogeneity of Fuel Pellets from the Fifth Collaborative Materials Exercise of the Nuclear Forensics International Technical Working Group

In 2017, the Nuclear Forensics International Technical Working Group (ITWG) organized their fifth 37 Collaborative Materials Exercise (CMX-5). The exercise samples were two uranium dioxide fuel pellets 38 manufactured from the same starting materials by different processes to have similar bulk isotopic 39 composition, but different spatial uranium isotopic distributions. Sets of identical materials were sent to 40 all participating laboratories, who then utilized their existing nuclear forensic capabilities to 41 independently analyse fuel pellets and identify similarities and differences of the materials’ 42 characteristics. The analytical methods used to probe the fuel pellets included ex situ, such as sectioning 43 or breaking up the pellets and analyzing dissolved pieces using inductively coupled plasma mass 44 spectrometry (ICP-MS), analyzing particles collected from intact or fragmented pellets by secondary ion 45 mass spectrometry (SIMS), as well as in situ methods, such as laser ablation coupled with ICP-MS, 46 autoradiography and nanoSIMS. In this paper we present the results of these independent analyses and 47 compare the capabilities of those nuclear forensic analytical methods to uncover details of the isotopic 48 heterogeneity of uranium fuel pellets.

Nuclear Forensic Analysis of Uranium Fuel Pellets,↗

NBL Pu CRM (Phase 1 Progress Report)

Several 100 μg aliquots of NBL CRM 137 Pu sulfate tetrahydrate were prepared in 20 mL glass vials at some time in the past and are expected to have similar chemical composition and similar concentrations of contaminants as the bulk 250 mg CRM 137 Pu sulfate tetrahydrate units. Thus, these units were characterized and used to test Pu purification chemistry to be employed on the larger unit. For preliminary characterization, the residue of bottle 6 was dissolved in 4 M HNO3/0.01 M HF and transferred quantitatively to a pre-weighed 30 mL Savillex Teflon vial with a total solution mass of approximately 18 g. A gravimetric aliquot was removed from this solution for characterization and the remaining solution was dried down and reconstituted in 8 M HNO 3 to test the anion exchange purification column.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Intercomparison of the Radio-Chronometric Ages of Plutonium-Certified Reference Materials with Distinct Isotopic Compositions

In this article, an intercomparison of the radio-chronometric ages of four distinct plutonium-certified reference materials varying in chemical form, isotopic composition, and period of production are presented. The cross-comparison of the different 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages obtained at four independent analytical facilities covering a range of laboratory environments from bulk sample processing to clean facilities dedicated to nuclear forensic investigation of environmental samples enables a true assessment of the state-of-practice in “age dating capabilities” for nuclear materials. The analytical techniques evaluated used modern mass spectrometer instrumentation including thermal ionization mass spectrometers and inductively coupled plasma mass spectrometers for isotopic abundance measurements. Both multicollector and single collector instruments were utilized to generate the data presented here. Consensus values established in this study make it possible to use these isotopic standards as quality control standards for radio-chronometry applications. Results highlight the need for plutonium isotopic standards that are certified for 234 U/ 238 Pu, 235 U/ 239 Pu, 236 U/ 240 Pu, and 241 Am/ 241 Pu model purification ages as well as other multigenerational radio-chronometers such as 237 Np/ 241 Pu. Due to the capabilities of modern analytical instrumentation, analytical laboratories that focus on trace level analyses can obtain model ages with marginally larger uncertainties than laboratories that handle bulk samples. Lastly, when isotope ratio measurement techniques like thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry with comparable precision are utilized, model purification ages with similar uncertainties are obtained.

36 MATERIALS SCIENCE↗

A case study in plutonium radiochronometry using multiple isotope systems

In this work, radiochronometry analyses of two Pu metals were performed using the 237 Np– 241 Am– 241 Pu, 234 U– 238 Pu, 235 U– 239 Pu, and 236 U–240Pu decay series. For one sample, all radiochronometers yield concordant model dates in 1959–1960, suggesting that the aqueous processing method used to purify Pu effectively removed U, Am and Np decay products from the bulk Pu. The second sample yields discordant model dates that are also older than the known production date in 1982. The excess U, Am and Np present in the sample imply that the sample was purified during at least two different episodes, using a combination of aqueous methods and molten salt extraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗