Search NASA⌕ Search

Engineering topics

Reynolds, J. M.

Publications and source records attributed to Reynolds, J. M..

On a High-Mirror Stellarator Reactor Exploratory Concept With Neutrons Concentrated on Centrifuge Liquids

In the framework of fusion energy research based on magnetic confinement, stellarators allow numerous degrees of freedom for the design of the magnetic trap and plasma shape. Taking advantage of these features, some plasma shapes might benefit several of the many integrated elements involved in commercial fusion reactors, like, e.g., decreasing the number, mass and complexity of replaced activated in-vessel components (IVC) (i.e., by using liquids), extraction of large power, tritium generation, and remote maintenance. Certainly, free-surface liquid materials were proposed for tokamaks and field-reversed configuration (FRC) to try to improve some of such elements, i.e., in advanced power extraction (APEX) studies. Some reactor-relevant quasi-isodynamic (QI) magnetic configurations exhibit a relatively straight sector of plasma and high magnetic mirror. The combination of those elements and possibilities in a single stellarator reactor concept might have some advantages, in spite of the uncertainties due to the current low technological readiness level (TRL). The proposed and studied reactor concept is based on a vacuum vessel having short curved sectors and longer wide cylindrical sectors, which encloses a high-mirror low-vertical-excursion magnetic configuration, and swirling liquids or rotating cylinders, which centrifuge molten Li salts located at the low field region. Thus, the molten salts (if possible covered by a thin layer of liquid lithium) would be located on the internal perimeter of the cylinder, to act as particle exhaust (except for helium), neutron power extractor, and tritium breeder. The high-mirror feature tries to concentrate the neutron power at the cylindrical sectors, which might avoid using breeding materials at the curved sectors. The different elements of the concept are exploratorily studied and defined, and the difficulties assessed.

centrifuge↗

Results of protective coating studies for the Hubble Space Telescope solar array

An account is given of the methods, results, and interpretive conclusions obtained by a series of comprehensive performance verification/qualification tests conducted on candidate coatings for the Hubble Space Telescope's (HST) solar array. These coatings are intended to minimize the effects of orbital atomic oxygen impingement on exposed materials. Attention was given to atomic oxygen exposure, UV exposure, thermal cycling, and electron and proton exposure. The V-10 and CVI-1140-1 candidate coatings were demonstrated to be adequately resistant to a five-year HST mission's environmental exposure.

Linton, Roger C.↗

Integrated development facility for the calibration of low-energy charged particle flight instrumentation

The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

Biddle, A. P.↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Apollo telescope mount: A partial listing of scientific publications and presentations, supplement 3

Compilations of bibliographies from the principal investigator groups of the Skylab solar observatory facility that gathered data from May 28, 1973, to February 8, 1974 are presented. The analysis of these data is presently under way. The publications listed are divided into the following categories: (1) journal publications; (2) journal publications submitted; (3) other publications; (4) presentations-national and international meetings; and (5) other presentations.

Reynolds, J. M.↗

X-ray reflectometer for optical efficiency and scatter measurements

An instrument has been developed to determine the reflection efficiency and scatter characteristics of optical samples at X-ray wavelengths from 1.5 to 113 A. The reflectometer operates in an oil-free vacuum chamber and measures the reflection efficiency and scatter characteristics as a function of the angle of incidence. The reflection efficiency is given for 8.34-A radiation incident on a fused silica sample finished to a flatness of one-tenth of a wavelength. The experimental reflection efficiency is compared with the theoretical data. The scatter curves are given for the direct X-ray beam and for the beam reflected from the fused silica sample at an angle of incidence of 50 arcmin. The full-width-at-half-maximum (FWHM) resolution of the instrument is approximately 13 arcsec, as determined by a least-squares smoothing of the experimental data.

Reynolds, J. M.↗

The theoretical reflectance of X-rays from optical surfaces

The theoretical reflectance of X-rays from various materials and evaporated films is presented. A computer program was written that computes the reflected intensity as a function of the angle of the incident radiation. The quantities necessary to generate the efficiency and their effect on the data are demonstrated. Five materials were chosen for evaluation: (1) fused silica, (2) chromium, (3) beryllium, (4) gold, and (5) a thin layer contaminant. Fused silica is a versatile and common material; chromium has high reflection efficiency at X-ray wavelengths and is in the middle of the atomic number range; beryllium contains a single atomic shell and has a low range atomic number; gold contains multiple atomic shells and has a high atomic number; the contaminant is treated as a thin film in the calculations and results are given as a function of thickness for selected wavelengths. The theoretical results are compared to experimental data at lambda = 8.34 A.

Neergaard, J. R.↗

X-ray reflection and scatter measurements on selected optical samples

The results from an experimental program to determine the reflection efficiency and scatter parameters of selected optical samples are presented. The measurements were made using 8.34A X-rays at various angles of incidence. Selected samples were contaminated after being measured and then remeasured to determine the effects of contamination. The instrumentation involved in taking the data, including the X-ray reflectometer and data processing equipment, is discussed in detail. The condition of the optical surfaces, the total reflection measurements, the scatter measurements, and the analysis are discussed.

Fields, S. A.↗

X-ray reflection efficiency of nickel-coated quartz optical flats

The reflection efficiency of quartz optical flats vacuum coated with 1000-A nickel was evaluated. Of the three vacuum coated samples tested, two had been contaminated during the firing of the Lunar Module Reaction Control System in the vacuum chamber. Measurements were made for 1.54-, 1.79-, and 2.29-A incident radiation. The reflection efficiency of the contaminated samples was reduced by as much as 50 percent for some angles of incidence.

Reynolds, J. M.↗