Search NASA⌕ Search

Engineering topics

Smith, Sean

Publications and source records attributed to Smith, Sean.

At least 19 records

Multiplex detection and identification of viral, bacterial, and protozoan pathogens in human blood and plasma using an expanded high-density resequencing microarray platform

Introduction: Nucleic acid tests for blood donor screening have improved the safety of the blood supply; however, increasing numbers of emerging pathogen tests are burdensome. Multiplex testing platforms are a potential solution. Methods: The Blood Borne Pathogen Resequencing Microarray Expanded (BBP-RMAv.2) can perform multiplex detection and identification of 80 viruses, bacteria and parasites. This study evaluated pathogen detection in human blood or plasma. Samples spiked with selected pathogens, each with one of 6 viruses, 2 bacteria and 5 protozoans were tested on this platform. The nucleic acids were extracted, amplified using multiplexed sets of primers, and hybridized to a microarray. The reported sequences were aligned to a database to identify the pathogen. To directly compare the microarray to an emerging molecular approach, the amplified nucleic acids were also submitted to nanopore next generation sequencing (NGS). Results: The BBP-RMAv.2 detected viral pathogens at a concentration as low as 100 copies/ml and a range of concentrations from 1,000 to 100,000 copies/ml for all the spiked pathogens. Coded specimens were identified correctly demonstrating the effectiveness of the platform. The nanopore sequencing correctly identified most samples and the results of the two platforms were compared. Discussion: These results indicated that the BBP-RMAv.2 could be employed for multiplex detection with potential for use in blood safety or disease diagnosis. The NGS was nearly as effective at identifying pathogens in blood and performed better than BBP-RMAv.2 at identifying pathogen-negative samples.

59 BASIC BIOLOGICAL SCIENCES↗

ToyProblem-EthyleneOx

This is a toy problem intended as an example on which to test V/UQ tools for multi-physics problems (coupled sub-models). It has grown from the solution to a graduate-school homework problem that has been posted on open-source (https://github.com/PhilipSmith-Canada/EthyleneOxideHomeWork).

Smith, Sean↗

Synthesis and Mechanical Properties of sub 5‐μm PolyUiO‐66 Thin Films on Gold Surfaces

Abstract Metal‐organic framework (MOF) thin films currently lack the mechanical stability needed for electronic device applications. Polymer‐based metal‐organic frameworks (polyMOFs) have been suggested to provide mechanical advantages over MOFs, however, the mechanical properties of polyMOFs have not yet been characterized. In this work, we developed a method to synthesize continuous sub‐5 μm polyUiO‐66(Zr) films on Au substrates, which allowed us to undertake initial mechanical property investigations. Comparisons between polyUiO‐66 and UiO‐66 thin films determined polyUiO‐66 thin films exhibit a lower modulus but similar hardness to UiO‐66 thin films. The initial mechanical characterization indicates that further development is needed to leverage the mechanical property advantages of polyMOFs over MOFs. Additionally, the demonstration in this work of a continuous surface‐supported polyUiO‐66 thin film enables utilization of this emerging class of polyMOF materials in sensors and devices applications.

Frederick, Esther↗

Achieving robust somatic mutation detection with deep learning models derived from reference data sets of a cancer sample

Accurate detection of somatic mutations is challenging but critical in understanding cancer formation, progression, and treatment. We recently proposed NeuSomatic, the first deep convolutional neural network-based somatic mutation detection approach, and demonstrated performance advantages on in silico data. In this study, we use the first comprehensive and well-characterized somatic reference data sets from the SEQC2 consortium to investigate best practices for using a deep learning framework in cancer mutation detection. Using the high-confidence somatic mutations established for a cancer cell line by the consortium, we identify the best strategy for building robust models on multiple data sets derived from samples representing real scenarios, for example, a model trained on a combination of real and spike-in mutations had the highest average performance. The strategy identified in our study achieved high robustness across multiple sequencing technologies for fresh and FFPE DNA input, varying tumor/normal purities, and different coverages, with significant superiority over conventional detection approaches in general, as well as in challenging situations such as low coverage, low variant allele frequency, DNA damage, and difficult genomic regions.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Infrared Detectors: expanding performance limits using ultrafast electron microscopy

This project aimed to identify the performance-limiting mechanisms in mid- to far infrared (IR) sensors by probing photogenerated free carrier dynamics in model detector materials using scanning ultrafast electron microscopy (SUEM). SUEM is a recently developed method based on using ultrafast electron pulses in combination with optical excitations in a pump- probe configuration to examine charge dynamics with high spatial and temporal resolution and without the need for microfabrication. Five material systems were examined using SUEM in this project: polycrystalline lead zirconium titanate (a pyroelectric), polycrystalline vanadium dioxide (a bolometric material), GaAs (near IR), InAs (mid IR), and Si/SiO 2 system as a prototypical system for interface charge dynamics. The report provides detailed results for the Si/SiO 2 and the lead zirconium titanate systems.

36 MATERIALS SCIENCE↗

Direct insights into the role of epoxy groups on cobalt sites for acidic H 2 O 2 production

Hydrogen peroxide produced by electrochemical oxygen reduction reaction provides a potentially cost effective and energy efficient alternative to the industrial anthraquinone process. In this study, we demonstrate that by modulating the oxygen functional groups near the atomically dispersed cobalt sites with proper electrochemical/chemical treatments, a highly active and selective oxygen reduction process for hydrogen peroxide production can be obtained in acidic electrolyte, showing a negligible amount of onset overpotential and nearly 100% selectivity within a wide range of applied potentials. Combined spectroscopic results reveal that the exceptionally enhanced performance of hydrogen peroxide generation originates from the presence of epoxy groups near the Co–N 4 centers, which has resulted in the modification of the electronic structure of the cobalt atoms. Computational modeling demonstrates these electronically modified cobalt atoms will enhance the hydrogen peroxide productivity during oxygen reduction reaction in acid, providing insights into the design of electroactive materials for effective peroxide production.<

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interface Defect Engineering for Improved Graphene-Oxide-Semiconductor Junction Photodetectors

The deeply depleted graphene-oxide-semiconductor (D 2 GOS) junction detector provides an effective architecture for photodetection, enabling direct readout of photogenerated charge. Because of an inherent gain mechanism proportional to graphene’s high mobility (μ), this detector architecture exhibits large responsivities and signal-to-noise ratios (SNR). The ultimate sensitivity of the D2GOS junction detector may be limited, however, because of the generation of dark charge originating from interface states at the semiconductor/dielectric junction. Here, we examine the performance limitations caused by dark charge and demonstrate its mitigation via the creation of low interface defect junctions enabled by surface passivation. The resulting devices exhibit responsivities exceeding 10 000 A/W—a value which is 10× greater than that of analogous devices without the passivating thermal oxide. Finally, with cooling of the detector, the responsivity further increases to over 25 000 A/W, underscoring the impact of surface generation on performance and thus the necessity of minimizing interfacial defects for this class of photodetector.

2D detector↗